Search NASA⌕ Search

SEARCH · Search NASA

Results for “performance data”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,405 records · Page 78

Training data selection for event classification in a highly variable environment

A problem of interest for nuclear nonproliferation is monitoring activities at nuclear facilities, where proliferation events may only take place a few times and often under variable conditions. Machine learning has revolutionized data analytics by enabling the use of measurable signatures to generate predictive models of facility operations. However, traditional methods for training these models require large, reliable data sets with labeled observations, a challenge for nonproliferation. Highly variable conditions further complicate this as events from training data may have occurred in conditions quite different from the event of interest. Our hypothesis is that when events occur in a highly variable environment, careful training data selection for each test event could outperform the standard approach of using all available training data. We developed a method to optimize training data selection for the given test event and applied it to predicting the power level of the High Flux Isotope Reactor (HFIR) at Oak Ridge National Laboratory. In this study, the reactor startup exhibits variability between occurrences due to natural variability in environmental conditions and operational procedures. Using a combination of analysis techniques, a similitude assessment was performed on data collected from HFIR to isolate clusters that were optimal for training a predictive model. Concepts such as dynamic time warping and Jaccard similarity were used in conjunction with clustering analysis. In order to validate this approach, the model was trained on every combination of unique training events and the predictive performance was compared to the performance using a subset of the training data selected by isolated clusters found through the similitude assessment.

Iyer, A↗

SU-E-T-65: Characterization of a 2D Array for QA and Pretreatment Plan Verification

Purpose: The OCTAVIUS detector729 is a 2D array of 729 air vented cubic plane parallel ion chambers used for pretreatment verification and QA. In this study we investigated dosimetric characteristics of this system for clinical photon beam dosimetry. Methods: Detector performance evaluation included determination of the location of the effective point of measurement (EPM), sensitivity, linearity, and reproducibility of detector response, as well as output factor, dose rate, and source to surface distance (SSD) dependence. Finally, assessment of wedge modulated fields was carried out. All the evaluations were performed five times for low and high photon energies. For reference measurements, a 0.6 cc ionization chamber was used. Data analysis and comparison of the OCTAVIUS detector with reference ion chamber data was performed using the VeriSoft patient plan verification software. Results: The reproducibility and stability of the measurements are excellent, the detector showed same signal with a maximum deviation of less than 0.5% in short and long term. Results of sensitivity test showed same signal with a maximum deviation of approximately 0.1%. As the detector 729 response is linear with dose and dose rate, it can be used for the measurement at regions of high dose gradient effectively. The detector agrees with the ionization chamber measurement to within 1% for SSD range of 75 to 125 cm. Also, its measured wedge modulated profiles matched very well with ion chamber dose profiles acquired in a water tank. Conclusions: As the response of the detector 729 is linear with dose and dose rate, it can be used for the measurements in the areas of dose gradients effectively. Based on the measurements and comparisons performed, this system is a reliable and accurate dosimeter for QA and pretreatment plan verification in radiotherapy.

60 APPLIED LIFE SCIENCES↗

Estimation of Uncertainties of Wall Temperature Accomplished by Model Calibration Technique Using Small to Large Scale Reflooding Test Data

The fidelity of the prediction can be evaluated by performing validation and uncertainty quantification with suitable test data. Nuclear power plant design and operation must accommodate the uncertainties in predicting system performance, where those uncertainties originating due to initial and boundary conditions, numerics, and modeling uncertainties. To improve the prediction of the reactor system performance, these various sources of uncertainties can be refined through model calibration technique. The objective of this work is to refine the model parameters and to estimate the uncertainties on parameters/responses during reflood phase. To accomplish this experiments should be performed, data collected, and the data utilized to complete model calibration for the thermal-hydraulic input parameters. Simulations were performed using Safety and Performance Analysis Code (SPACE) developed by multiple research institutes in South Korea to predict the thermal hydraulic system behaviors of nuclear power plants. Since existing experimental data were obtained from several tests performed at the small scale, scaling considerations must be addressed during the uncertainty quantification process. (authors)

42 ENGINEERING↗

Scalable Performance Measurement and Analysis

Concurrency levels in large-scale, distributed-memory supercomputers are rising exponentially. Modern machines may contain 100,000 or more microprocessor cores, and the largest of these, IBM's Blue Gene/L, contains over 200,000 cores. Future systems are expected to support millions of concurrent tasks. In this dissertation, we focus on efficient techniques for measuring and analyzing the performance of applications running on very large parallel machines. Tuning the performance of large-scale applications can be a subtle and time-consuming task because application developers must measure and interpret data from many independent processes. While the volume of the raw data scales linearly with the number of tasks in the running system, the number of tasks is growing exponentially, and data for even small systems quickly becomes unmanageable. Transporting performance data from so many processes over a network can perturb application performance and make measurements inaccurate, and storing such data would require a prohibitive amount of space. Moreover, even if it were stored, analyzing the data would be extremely time-consuming. In this dissertation, we present novel methods for reducing performance data volume. The first draws on multi-scale wavelet techniques from signal processing to compress systemwide, time-varying load-balance data. The second uses statistical sampling to select a small subset of running processes to generate low-volume traces. A third approach combines sampling and wavelet compression to stratify performance data adaptively at run-time and to reduce further the cost of sampled tracing. We have integrated these approaches into Libra, a toolset for scalable load-balance analysis. We present Libra and show how it can be used to analyze data from large scientific applications scalably.

99 GENERAL AND MISCELLANEOUS↗

A Bayesian Approach for Quantifying Data Scarcity when Modeling Human Behavior via Inverse Reinforcement Learning

Computational models that formalize complex human behaviors enable study and understanding of such behaviors. However, collecting behavior data required to estimate the parameters of such models is often tedious and resource intensive. Thus, estimating dataset size as part of data collection planning (also known as Sample Size Determination) is important to reduce the time and effort of behavior data collection while maintaining an accurate estimate of model parameters. In this paper, we present a sample size determination method based on Uncertainty Quantification (UQ) for a specific Inverse Reinforcement Learning (IRL) model of human behavior, in two cases: 1) pre-hoc experiment design—conducted in the planning stage before any data is collected, to guide the estimation of how many samples to collect; and 2) post-hoc dataset analysis—performed after data is collected, to decide if the existing dataset has sufficient samples and whether more data is needed. Here, we validate our approach in experiments with a realistic model of behaviors of people with Multiple Sclerosis (MS) and illustrate how to pick a reasonable sample size target. Our work enables model designers to perform a deeper, principled investigation of effects of dataset size on IRL.

97 MATHEMATICS AND COMPUTING↗

Advancing the Fork detector for quantitative spent nuclear fuel verification

The Fork detector is widely used by the safeguards inspectorate of the European Atomic Energy Community (EURATOM) and the International Atomic Energy Agency (IAEA) to verify spent nuclear fuel. Fork measurements are routinely performed for safeguards prior to dry storage cask loading. Additionally, spent fuel verification will be required at the facilities where encapsulation is performed for acceptance in the final repositories planned in Sweden and Finland. The use of the Fork detector as a quantitative instrument has not been prevalent due to the complexity of correlating the measured neutron and gamma ray signals with fuel inventories and operator declarations. A spent fuel data analysis module based on the ORIGEN burnup code was recently implemented to provide automated real-time analysis of Fork detector data. This module allows quantitative predictions of expected neutron count rates and gamma units as measured by the Fork detectors using safeguards declarations and available reactor operating data. This study describes field testing of the Fork data analysis module using data acquired from 339 assemblies measured during routine dry cask loading inspection campaigns in Europe. Assemblies include both uranium oxide and mixed-oxide fuel assemblies. More recent measurements of 50 spent fuel assemblies at the Swedish Central Interim Storage Facility for Spent Nuclear Fuel are also analyzed. An evaluation of uncertainties in the Fork measurement data is performed to quantify the ability of the data analysis module to verify operator declarations and to develop quantitative go/no-go criteria for safeguards verification measurements during cask loading or encapsulation operations. The goal of this approach is to provide safeguards inspectors with reliable real-time data analysis tools to rapidly identify discrepancies in operator declarations and to detect potential partial defects in spent fuel assemblies with improved reliability and minimal false positive alarms. Finally, the results are summarized, and sources and magnitudes of uncertainties are identified, and the impact of analysis uncertainties on the ability to confirm operator declarations is quantified.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Dark Energy Survey Year 3 results: Curved-sky weak lensing mass map reconstruction

ABSTRACT We present reconstructed convergence maps, mass maps, from the Dark Energy Survey (DES) third year (Y3) weak gravitational lensing data set. The mass maps are weighted projections of the density field (primarily dark matter) in the foreground of the observed galaxies. We use four reconstruction methods, each is a maximum a posteriori estimate with a different model for the prior probability of the map: Kaiser–Squires, null B-mode prior, Gaussian prior, and a sparsity prior. All methods are implemented on the celestial sphere to accommodate the large sky coverage of the DES Y3 data. We compare the methods using realistic ΛCDM simulations with mock data that are closely matched to the DES Y3 data. We quantify the performance of the methods at the map level and then apply the reconstruction methods to the DES Y3 data, performing tests for systematic error effects. The maps are compared with optical foreground cosmic-web structures and are used to evaluate the lensing signal from cosmic-void profiles. The recovered dark matter map covers the largest sky fraction of any galaxy weak lensing map to date.

79 ASTRONOMY AND ASTROPHYSICS↗

Comparison of GEANT4 very low energy cross section models with experimental data in water

Purpose: The GEANT4 general-purpose Monte Carlo simulation toolkit is able to simulate physical interaction processes of electrons, hydrogen and helium atoms with charge states (H{sup 0}, H{sup +}) and (He{sup 0}, He{sup +}, He{sup 2+}), respectively, in liquid water, the main component of biological systems, down to the electron volt regime and the submicrometer scale, providing GEANT4 users with the so-called ''GEANT4-DNA'' physics models suitable for microdosimetry simulation applications. The corresponding software has been recently re-engineered in order to provide GEANT4 users with a coherent and unique approach to the simulation of electromagnetic interactions within the GEANT4 toolkit framework (since GEANT4 version 9.3 beta). This work presents a quantitative comparison of these physics models with a collection of experimental data in water collected from the literature. Methods: An evaluation of the closeness between the total and differential cross section models available in the GEANT4 toolkit for microdosimetry and experimental reference data is performed using a dedicated statistical toolkit that includes the Kolmogorov-Smirnov statistical test. The authors used experimental data acquired in water vapor as direct measurements in the liquid phase are not yet available in the literature. Comparisons with several recommendations are also presented. Results: The authors have assessed the compatibility of experimental data with GEANT4 microdosimetry models by means of quantitative methods. The results show that microdosimetric measurements in liquid water are necessary to assess quantitatively the validity of the software implementation for the liquid water phase. Nevertheless, a comparison with existing experimental data in water vapor provides a qualitative appreciation of the plausibility of the simulation models. The existing reference data themselves should undergo a critical interpretation and selection, as some of the series exhibit significant deviations from each other. Conclusions: The GEANT4-DNA physics models available in the GEANT4 toolkit have been compared in this article to available experimental data in the water vapor phase as well as to several published recommendations on the mass stopping power. These models represent a first step in the extension of the GEANT4 Monte Carlo toolkit to the simulation of biological effects of ionizing radiation.

61 RADIATION PROTECTION AND DOSIMETRY↗

Aerosol Plume Detection Algorithm Based on Image Segmentation of Scanning Atmospheric Lidar Data

An image-processing algorithm has been developed to identify aerosol plumes in scanning lidar backscatter data. The images in this case consist of lidar data in a polar coordinate system. Each full lidar scan is taken as a fixed image in time, and sequences of such scans are considered functions of time. The data are analyzed in both the original backscatter polar coordinate system and a lagged coordinate system. The lagged coordinate system is a scatterplot of two datasets, such as subregions taken from the same lidar scan (spatial delay), or two sequential scans in time (time delay). The lagged coordinate system processing allows for finding and classifying clusters of data. The classification step is important in determining which clusters are valid aerosol plumes and which are from artifacts such as noise, hard targets, or background fields. These cluster classification techniques have skill since both local and global properties are used. Furthermore, more information is available since both the original data and the lag data are used. Performance statistics are presented for a limited set of data processed by the algorithm, where results from the algorithm were compared to subjective truth data identified by a human.

97 MATHEMATICS AND COMPUTING↗

SU-E-J-143: Short- and Near-Term Effects of Proton Therapy On Cerebral White Matter

Purpose: To assess early effects of proton therapy on the structural integrity of cerebral white matter in relation to the subsequent near-term development of such effects. Methods: Sixteen children (aged 2–19 years) with craniopharyngioma underwent proton therapy of 54 Cobalt Gray Equivalent (CGE) in a prospective therapeutic trial. Diffusion tensor imaging (DTI) was performed at baseline before proton therapy and every 3 months thereafter. Tract-based spatial statics analysis of DTI data was performed to derive the fractional anisotropy (FA) and radial diffusivity (RD) in 26 volumes of interest (VOIs). The dose distributions were spatially normalized to identify VOIs prone to high doses. The longitudinal percentage changes of the FA and RD in these VOIs at 3 and 12 months from the baseline were calculated, and their relationships were evaluated. Results: The average dose was highest to the cerebral peduncle (CP), corticospinal tract (CST) in the pons, pontine crossing tract (PCT), anterior/posterior limbs of the internal capsule (ALIC/PLIC), and genu of the corpus callosum (GCC). It ranged from 33.3 GCE (GCC) to 49.7 GCE (CP). A mild but statistically significant (P<0.05) decline of FA was observed 3 months after proton therapy in all VOIs except the PLIC and ranged from −1.7% (ALIC) to −2.8% (PCT). A significant increase of RD was found in the CP (3.5%) and ALIC (2.1%). The average longitudinal change from the baseline was reduced at 12 months for most VOIs. However, the standard deviation increased, indicating that the temporal pattern varied individually. The follow-up measurements at 3 and 12 months correlated for the CP, CST, PCT, and GCC (P < 0.04). Conclusion: DTI data suggest early (3 months) effects of proton therapy on microstructures in the white matter. The subsequent follow-up indicated individual variation of the changes, which was partly implied by the early effects.

60 APPLIED LIFE SCIENCES↗

Emulation Framework for Distributed Large-Scale Systems Integration

Recent trends in systems engineering include integration of very large-scale systems, which entails significant challenges when they are geographically dispersed. In these scenarios, intelligent integration of distributed large-scale systems requires significant coordination among hardware elements as well as all software components. The approach of integrated systems (both computing platform and experimental equipment) for end-to-end orchestration is called federation. Virtual frameworks can aid in the testing, assessment, and implementation of a functional system of interconnected resources. We present an emulation framework that replicates the software environments of multi-site federations of computing systems and instruments. Our emulation framework allows systems engineers to reduce developmentcost and avoid disruptions to production infrastructure. Our framework was effectively used to develop and test software modules for various tasks including container orchestration and instrument access. For performance assessment, however, the emulated framework is severely limited in providing accurate network and IO measurements at 10 Gbps and higher data rates. The data transfer performance profiles estimated using these emulated measurements are usually inaccurate for high bandwidth and high latency connections, since emulation does not accurately reflect the critical network transport dynamics.We utilize measurements from a physical testbed with hardware network emulators to obtain data transfer profiles that closely match the expected profiles for the emulated federations. We show the effectiveness of our approach by an illustrative example of integrated (federated) multi-site ultra large-scale systems that are connected via high speed wide area networks.

Imam, Neena↗

Multi-level Layout Optimization for Efficient Spatio-temporal Queries on ISABELA-compressed Data

The size and scope of cutting-edge scientific simulations are growing much faster than the I/O subsystems of their runtime environments, not only making I/O the primary bottleneck, but also consuming space that pushes the storage capacities of many computing facilities. These problems are exacerbated by the need to perform data-intensive analytics applications, such as querying the dataset by variable and spatio-temporal constraints, for what current database technologies commonly build query indices of size greater than that of the raw data. To help solve these problems, we present a parallel query-processing engine that can handle both range queries and queries with spatio-temporal constraints, on B-spline compressed data with user-controlled accuracy. Our method adapts to widening gaps between computation and I/O performance by querying on compressed metadata separated into bins by variable values, utilizing Hilbert space-filling curves to optimize for spatial constraints and aggregating data access to improve locality of per-bin stored data, reducing the false positive rate and latency bound I/O operations (such as seek) substantially. We show our method to be efficient with respect to storage, computation, and I/O compared to existing database technologies optimized for query processing on scientific data.

Computer Science↗

ChemML : A machine learning and informatics program package for the analysis, mining, and modeling of chemical and materials data

ChemML is an open machine learning (ML) and informatics program suite that is designed to support and advance the data-driven research paradigm that is currently emerging in the chemical and materials domain. ChemML allows its users to perform various data science tasks and execute ML workflows that are adapted specifically for the chemical and materials context. Key features are automation, general-purpose utility, versatility, and user-friendliness in order to make the application of modern data science a viable and widely accessible proposition in the broader chemistry and materials community. Finally, ChemML is also designed to facilitate methodological innovation, and it is one of the cornerstones of the software ecosystem for data-driven in silico research.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

High-resolution neutron time-of-flight measurements for light water at the Spallation Neutron Source (SNS), Oak Ridge National Laboratory

Series of light water inelastic neutron scattering experiments have been made at the Oak Ridge National Laboratory (ORNL), Spallation Neutron Source (SNS) covering temperatures ranging from 295 K to 600 K and pressures of 1 bar and 150 bar. The temperatures and pressures ranges correspond to that of pressurized light water reactors. The inelastic scattering measurements will help the development of light water thermal scattering kernels, also known as S (α,β) thermal scattering law (TSL), in a consistent fashion given the amount and the quality of the measured data. Light water thermal scattering evaluations available in existing nuclear data libraries have certain limitations and pitfalls. This paper introduces the state of the art of the light water thermal scattering cross-section data not only for room temperature but as well as for reactor operating temperatures, i.e. 550 - 600 K. During the past few years there has been a renewed interest in re-investigating the existing TSL models and utilize the recent experimental data or perform molecular dynamics simulations. It should be pointed out that no single TSL evaluation is based entirely on experimental data and one has to rely on TSL models or a combination of both. New TOF measurement of light water at the SNS, with a detailed description of the experimental setup, measurement conditions, and the associated foreseen results is presented in this paper. The analysis of the experimental data would help in validating the existing approach based on old experimental data or based on molecular dynamic simulations using classical water models, knowledge of which is very important to generate TSL libraries at reactor operating conditions.

Leal, Luiz C.↗

Getting the Most Out of Your Crystals: Data Collection at the New High-Flux, Microfocus MX Beamlines at NSLS-II

Advances in synchrotron technology are changing the landscape of macromolecular crystallography. The two recently opened beamlines at NSLS-II—AMX and FMX—deliver high-flux microfocus beams that open new possibilities for crystallographic data collection. They are equipped with state-of-the-art experimental stations and automation to allow data collection on previously intractable crystals. Optimized data collection strategies allow users to tailor crystal positioning to optimally distribute the X-ray dose over its volume. Vector data collection allows the user to define a linear trajectory along a well diffracting volume of the crystal and perform rotational data collection while moving along the vector. This is particularly well suited to long, thin crystals. We describe vector data collection of three proteins—Akt1, PI3Kα, and CDP-Chase—to demonstrate its application and utility. For smaller crystals, we describe two methods for multicrystal data collection in a single loop, either manually selecting multiple centers (using H108A-PHM as an example), or “raster-collect”, a more automated approach for a larger number of crystals (using CDP-Chase as an example).

59 BASIC BIOLOGICAL SCIENCES↗

Initial Calibration of Large Timing Arrays for the LHC

In preparation for HL-LHC operation a number of new detector systems are being constructed with timing precision on physics objects of <50 picoseconds. These time stamps will reduce the level of pileup induced backgrounds in this LHC phase where the number of interactions per crossing will reach of order 100-200. In the case of CMS, three new systems have initially to be corrected for the usual amplitude walk resulting from the effect of variations in signal size on leading edge timing. In these systems the resulting timing spread (ie walk) ranges from one to four nanoseconds. In the following note we advocate approaching this initial calibration for walk as a calculable correction given early calibration during commissioning -- rather than depending on special collider data to perform the calibration. We derive a simple analytic expression for the walk correction and confirm its effectiveness with lab data.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

A Final Review of the Performance of the CDF Run II Data Acquisition System

The CDF Collider Detector at Fermilab ceased data collection on September 30, 2011 after over twenty-five years of operation. We review the performance of the CDF Run II data acquisition systems over the last ten of these years while recording nearly 10 inverse femtobarns of proton-antiproton collisions with a high degree of efficiency - exceeding 83%. Technology choices in the online control and configuration systems and front-end embedded processing have impacted the efficiency and quality of the data accumulated by CDF, and have had to perform over a large range of instantaneous luminosity values and trigger rates. We identify significant sources of problems and successes. In particular, we present our experience computing and acquiring data in a radiation environment, and attempt to correlate system technical faults with radiation dose rate and technology choices.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗