Search NASA⌕ Search

SEARCH · Search NASA

Results for “process data”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,405 records · Page 78

Observation of Cosmic-Ray Anisotropy in the Southern Hemisphere with 12 yr of Data Collected by the IceCube Neutrino Observatory

We analyzed the 7.92 × 10 11 cosmic-ray-induced muon events collected by the IceCube Neutrino Observatory from 2011 May 13, when the fully constructed experiment started to take data, to 2023 May 12. This data set provides an up-to-date cosmic-ray arrival direction distribution in the Southern Hemisphere with unprecedented statistical accuracy covering more than a full period length of a solar cycle. Improvements in Monte Carlo event simulation and better handling of year-to-year differences in data processing significantly reduce systematic uncertainties below the level of statistical fluctuations compared to the previously published results. We confirm the observation of a change in the angular structure of the cosmic-ray anisotropy between 10 TeV and 1 PeV, more specifically in the 100–300 TeV energy range. For the first time, we analyzed the angular power spectrum at different energies. The observed variations of the power spectra with energy suggest relatively reduced large-scale features at high energy compared to those of medium and small scales. The large volume of data enhances the statistical significance at higher energies, up to the PeV scale, and smaller angular scales, down to approximately 6° compared to previous findings.

79 ASTRONOMY AND ASTROPHYSICS↗

Data and scripts from: “Denoising autoencoder for reconstructing sensor observation data and predicting evapotranspiration: noisy and missing values repair and uncertainty quantification”

This data package includes data and scripts from the manuscript “Denoising autoencoder for reconstructing sensor observation data and predicting evapotranspiration: noisy and missing values repair and uncertainty quantification”.The study addressed common challenges faced in environmental sensing and modeling, including uncertain input data, missing sensor observations, and high-dimensional datasets with interrelated but redundant variables. Point-scaled meteorological and soil sensor observations were perturbed with noises and missing values, and denoising autoencoder (DAE) neural networks were developed to reconstruct the perturbed data and further predict evapotranspiration. This study concluded that (1) the reconstruction quality of each variable depends on its cross-correlation and alignment to the underlying data structure, (2) uncertainties from the models were overall stronger than those from the data corruption, and (3) there was a tradeoff between reducing bias and reducing variance when evaluating the uncertainty of the machine learning models.This package includes:(1) Four ipython scripts (.ipynb): “DAE_train.ipynb” trains and evaluates DAE neural networks, “DAE_predict.ipynb” makes predictions from the trained DAE models, “ET_train.ipynb” trains and evaluates ET prediction neural networks, and “ET_predict.ipynb” makes predictions from trained ET models.(2) One python file (.py): “methods.py” includes all user-defined functions and python codes used in the ipython scripts.(3) A “sub_models” folder that includes five trained DAE neural networks (in pytorch format, .pt), which could be used to ingest input data before being fed to the downstream ET models in ‘ET_train.ipynb” or ‘ET_predict.ipynb’.(4) Two data files (.csv). Daily meteorological, vegetation, and soil data is in “df_data.csv”, where “df_meta.csv” contains the location and time information of “df_data.csv”. Each row (index) in “df_meta.csv” corresponds to each row in “df_data.csv”. These data files are formatted to follow the data structure requirements and be directly used in the ipython scripts, and they have been shuffled chronologically to train machine learning models. The meteorological and soil data was collected using point sensors between 2019-2023 at(4.a) Three shrub-dominated field sites in East River, Colorado (named “ph1”, “ph2” and “sg5” in “df_meta.csv”, where “ph1” and “ph2” were located at PumpHouse Hillslopes, and “sg5” was at Snodgrass Mountain meadow) and(4.b) One outdoor, mesoscale, and herbaceous-dominated experiment in Berkeley, California (named “tb” in “df_meta.csv”, short for Smartsoils Testbed at Lawrence Berkeley National Lab).- See "df_data_dd.csv" and "df_meta_dd.csv" for variable descriptions and the Methods section for additional data processing steps. See "flmd.csv" and "README.txt" for brief file descriptions.- All ipython scripts and python files are written in and require PYTHON language software.

54 ENVIRONMENTAL SCIENCES↗

Thermophysical and gas-dynamic characteristics of laser-induced gasplasma flows under femtosecond laser ablation of titanium in vacuum

We report the results of experimental investigation of thermophysical and gas-dynamic characteristics of the gas-plasma flows induced by ultrashort (45 – 60 fs) laser pulse irradiation (the radiation wavelength λ = 400, 800 nm) of a titanium target in vacuum (∼5 × 10{sup -4} mbar). The use of combined interferometric technique and complex experimental data processing allowed us to estimate the momentum coupling coefficient (C{sub m} ∼ 10{sup -4} N W{sup -1}), the efficiency of laser energy conversion to the kinetic energy of the gas-plasma flow (65% – 85%), the spatiotemporal distributions of the particle density (n{sub e} = 10{sup 18} – 10{sup 20} cm{sup -3}) and velocity ((v)=4 – 9 km s{sup -1}), the static (10{sup 6} – 10{sup 8} Pa) and total (10{sup 7} – 10{sup 11} Pa) pressure and temperature (T=7 – 50 kK) in the flow. Our data are compared with published data obtained by other methods. (interaction of laser radiation with matter. laser plasma)

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Scalable subsurface inverse modeling of huge data sets with an application to tracer concentration breakthrough data from magnetic resonance imaging

When characterizing subsurface properties is crucial for reliable and cost-effective groundwater supply management and contaminant remediation. With recent advances in sensor technology, large volumes of hydro-geophysical and geochemical data can be obtained to achieve high-resolution images of subsurface properties. However, characterization with such a large amount of information requires prohibitive computational costs associated with “big data” processing and numerous large-scale numerical simulations. To tackle such difficulties, the Principal Component Geostatistical Approach (PCGA) has been proposed as a “Jacobian-free” inversion method that requires much smaller forward simulation runs for each iteration than the number of unknown parameters and measurements needed in the traditional inversion methods. PCGA can be conveniently linked to any multi-physics simulation software with independent parallel executions. In our paper, we extend PCGA to handle a large number of measurements (e.g. 106 or more) by constructing a fast preconditioner whose computational cost scales linearly with the data size. For illustration, we characterize the heterogeneous hydraulic conductivity (K) distribution in a laboratory-scale 3-D sand box using about 6 million transient tracer concentration measurements obtained using magnetic resonance imaging. Since each individual observation has little information on the K distribution, the data was compressed by the zero-th temporal moment of breakthrough curves, which is equivalent to the mean travel time under the experimental setting. Moreover, only about 2,000 forward simulations in total were required to obtain the best estimate with corresponding estimation uncertainty, and the estimated K field captured key patterns of the original packing design, showing the efficiency and effectiveness of the proposed method. This article is protected by copyright. All rights reserved.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Community-Driven Methods for Open and Reproducible Software Tools for Analyzing Datasets from Atom Probe Microscopy

Atom probe tomography, and related methods, probe the three-dimensional architecture of a material. The software tools that microscopists use, and how these tools are connected into workflows, makes a substantial contribution to the accuracy and precision of such a material characterization experiment. Typically, we adapt methods from other communities like mathematics, data science, computational geometry, artificial intelligence, or scientific computing. We also realize that improving on research data management is a challenge when it comes to align with the FAIR data stewardship principles. Faced with this global challenge, we are convinced that collaborating is useful. Here, we report the results and challenges with an inter-laboratory call for developing test cases for several types of atom probe software tools. The results support why defining detailed recipes of software workflows and sharing these recipes is necessary and rewarding: Open source tools and (meta)data exchange can help to make our day-to-day data processing tasks become more efficient, the training of new users and knowledge transfer become easier, and assist us with automated quantification of uncertainties to gain access to substantiated results.

36 MATERIALS SCIENCE↗

Method and apparatus for two-layer copy-on-write

A system, apparatus and method are provided in which a range of virtual memory addresses and a copy of that range are mapped to the same first system address range in a data processing system until an address in the virtual memory address range, or its copy, is written to. The common system address range includes a number of divisions. Responsive to a write request to an address in a division of the common address range, a second system address range is generated. The second system address range is mapped to the same physical addresses as the first system address range, except that the division containing the address to be written to and its corresponding division in the second system address range are mapped to different physical addresses. First layer mapping data may be stored in a range table buffer and updated when the second system address range is generated.

97 MATHEMATICS AND COMPUTING↗

Generation of the Thermal Scattering Law of Uranium Dioxide with Ab Initio Lattice Dynamics to Capture Crystal Binding Effects on Neutron Interactions

Scattering of thermal neutrons and Doppler broadening of epithermal neutron resonances in uranium and its compounds may be sensitive to crystal binding. The thermal scattering law (TSL) for uranium dioxide, which captures crystal binding effects, has been reevaluated for ENDF/B-VIII.0. Phonon spectra were generated using ab initio lattice dynamics for the paramagnetic phase and validated against experiment. Improved agreement with the Debye-Waller coefficient as a function of temperature is found relative to the spectrum used for the ENDF/B-VII.1 evaluation. The TSL was generated using the phonon expansion method within the NJOY nuclear data processing package and was found to be in reasonable agreement with inelastic neutron scattering measurements. The present evaluation predicts a reduction in the inelastic scattering cross section relative to ENDF/B-VII.1 and a total scattering cross section consistent with neutron transmission experiments

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Particle velocity measurement within a free-falling particle curtain using microscopic shadow velocimetry

We report an optical method for particle velocity measurement that is suitable for the measurement of particle velocities within dense particle-laden flows with high spatial resolution. The technique is based on particle shadow velocimetry with the use of a long-distance microscopic lens for images collection. The narrow depth of field of the lens allows particles within the focal plane to have much higher pattern intensities than those outside it on the collected images. Data processing was then employed to remove particles from outside the focal plane based on the gradient of the signal and a threshold. Following this, particle velocity was calculated from two successive images in the usual way. The technique was successfully demonstrated in a free-falling particle curtain with volume fractions in the four-way coupling regime of near-spherical micro-particles falling under gravity. The method was successfully employed to measure the transverse velocity profile through the curtain, which is the first time that such a measurement has been performed. Other highly-fidelity experimental data, which is also well suited to model development and validation, include the particle mass flow rate, curtain thickness and opacity.

Han, Shipu (ORCID:0000000278545882)↗

Large Scale Tracking Algorithms

Low signal-to-noise data processing algorithms for improved detection, tracking, discrimination and situational threat assessment are a key research challenge. As sensor technologies progress, the number of pixels will increase significantly. This will result in increased resolution, which could improve object discrimination, but unfortunately, will also result in a significant increase in the number of potential targets to track. Many tracking techniques, like multi-hypothesis trackers, suffer from a combinatorial explosion as the number of potential targets increase. As the resolution increases, the phenomenology applied towards detection algorithms also changes. For low resolution sensors, "blob" tracking is the norm. For higher resolution data, additional information may be employed in the detection and classification steps. The most challenging scenarios are those where the targets cannot be fully resolved, yet must be tracked and distinguished for neighboring closely spaced objects. Tracking vehicles in an urban environment is an example of such a challenging scenario. This report evaluates several potential tracking algorithms for large-scale tracking in an urban environment.

45 MILITARY TECHNOLOGY, WEAPONRY, AND NATIONAL DEF↗

Large scale tracking algorithms

Low signal-to-noise data processing algorithms for improved detection, tracking, discrimination and situational threat assessment are a key research challenge. As sensor technologies progress, the number of pixels will increase signi cantly. This will result in increased resolution, which could improve object discrimination, but unfortunately, will also result in a significant increase in the number of potential targets to track. Many tracking techniques, like multi-hypothesis trackers, suffer from a combinatorial explosion as the number of potential targets increase. As the resolution increases, the phenomenology applied towards detection algorithms also changes. For low resolution sensors, "blob" tracking is the norm. For higher resolution data, additional information may be employed in the detection and classfication steps. The most challenging scenarios are those where the targets cannot be fully resolved, yet must be tracked and distinguished for neighboring closely spaced objects. Tracking vehicles in an urban environment is an example of such a challenging scenario. This report evaluates several potential tracking algorithms for large-scale tracking in an urban environment.

97 MATHEMATICS AND COMPUTING↗

Robust framework and software implementation for fast speciation mapping

One of the greatest benefits of synchrotron radiation is the ability to perform chemical speciation analysis through X-ray absorption spectroscopies (XAS). XAS imaging of large sample areas can be performed with either full-field or raster-scanning modalities. A common practice to reduce acquisition time while decreasing dose and/or increasing spatial resolution is to compare X-ray fluorescence images collected at a few diagnostic energies. In this work, several authors have used different multivariate data processing strategies to establish speciation maps. Furthermore, the theoretical aspects and assumptions that are often made in the analysis of these datasets are focused on. A robust framework is developed to perform speciation mapping in large bulk samples at high spatial resolution by comparison with known references. Two fully operational software implementations are provided: a user-friendly implementation within the MicroAnalysis Toolkit software, and a dedicated script developed under the R environment. The procedure is exemplified through the study of a cross section of a typical fossil specimen. Additionally, the algorithm provides accurate speciation and concentration mapping while decreasing the data collection time by typically two or three orders of magnitude compared with the collection of whole spectra at each pixel. Whereas acquisition of spectral datacubes on large areas leads to very high irradiation times and doses, which can considerably lengthen experiments and generate significant alteration of radiation-sensitive materials, this sparse excitation energy procedure brings the total irradiation dose greatly below radiation damage thresholds identified in previous studies. This approach is particularly adapted to the chemical study of heterogeneous radiation-sensitive samples encountered in environmental, material, and life sciences.

47 OTHER INSTRUMENTATION↗

Application and Certification of Comparative Vacuum Monitoring Sensors for Structural Health Monitoring of 737 Wing Box Fittings

Multi-site fatigue damage, hidden cracks in hard-to-reach locations, disbonded joints, erosion, impact, and corrosion are among the major flaws encountered in today's extensive fleet of aging aircraft and space vehicles. The use of in-situ sensors for real-time health monitoring of aircraft structures are a viable option to overcome inspection impediments stemming from accessibility limitations, complex geometries, and the location and depth of hidden damage. Reliable, structural health monitoring systems can automatically process data, assess structural condition, and signal the need for human intervention. Prevention of unexpected flaw growth and structural failure can be improved if on-board health monitoring systems are used to continuously assess structural integrity. Such systems are able to detect incipient damage before catastrophic failures occurs. Condition-based maintenance practices could be substituted for the current time-based maintenance approach. Other advantages of on-board distributed sensor systems are that they can eliminate costly, and potentially damaging, disassembly, improve sensitivity by producing optimum placement of sensors and decrease maintenance costs by eliminating more time- consuming manual inspections. This report presents a Sandia Labs-aviation industry effort to move SHM into routine use for aircraft maintenance. This program addressed formal SHM technology validation and certification issues so that the full spectrum of concerns, including design, deployment, performance and certification were appropriately considered. The Airworthiness Assurance NDI Validation Center (AANC) at Sandia Labs, in conjunction with Boeing, Delta Air Lines, Structural Monitoring Systems Ltd., Anodyne Electronics Manufacturing Corp. and the Federal Aviation Administration (FAA) carried out a certification program to formally introduce Comparative Vacuum Monitoring (CVM) as a structural health monitoring solution to a specific aircraft wing box application. Validation tasks were designed to address the SHM equipment, the health monitoring task, the resolution required, the sensor interrogation procedures, the conditions under which the monitoring will occur, the potential inspector population, adoption of CVM into an airline maintenance program and the document revisions necessary to allow for routine use of CVM as an alternate means of performing periodic structural inspects. To carry out the validation process, knowledge of aircraft maintenance practices was coupled with an unbiased, independent evaluation. Sandia Labs designed, implemented, and analyzed the results from a focused and statistically-relevant experimental effort to quantify the reliability of the CVM system applied to the Boeing 737 Wing Box fitting application. All factors that affect SHM sensitivity were included in this program: flaw size, shape, orientation and location relative to the sensors, as well as operational and environmental variables. Statistical methods were applied to performance data to derive Probability of Detection (POD) values for CVM sensors in a manner that agrees with current nondestructive inspection (NDI) validation requirements and also is acceptable to both the aviation industry and regulatory bodies. This report presents the use of several different statistical methods, some of them adapted from NDI performance assessments and some proposed to address the unique nature of damage detection via SHM systems, and discusses how they can converge to produce a confident quantification of SHM performance An important element in developing SHM validation processes is a clear understanding of the regulatory measures needed to adopt SHM solutions along with the knowledge of the structural and maintenance characteristics that may impact the operational performance of an SHM system. This report describes the major elements of an SHM validation approach and differentiates the SHM elements from those found in NDI validation. The activities conducted in this program demonstrated the feasibility of routine SHM usage in general and CVM in particular for the application selected. They also helped establish an optimum OEM-airline-regulator process and determined how to safely adopt SHM solutions. This formal SHM validation will allow aircraft manufacturers and airlines to confidently make informed decisions about the proper utilization of CVM technology. It will also streamline the regulatory actions and formal certification measures needed to assure the safe application of SHM solutions.

42 ENGINEERING↗

WE-AB-BRB-09: Real Time In Vivo Scintillating Fiber Array Detector for Medical LINACS

Purpose: An in vivo transmission scintillation fiber detector was developed to monitor patient treatment in real time for the enhancement of patient safety and treatment accuracy. The detector system is capable of monitoring each pulse from a medical LINAC during treatment to determine the dose delivered as treatment progresses. Methods: The detector system consists of 60 parallel scintillating fibers coupled to fast data processing optoelectronics that can monitor the beam fluence in real time. Each 2.5mm{sup 2} square fiber is aligned with an MLC leaf pair and is long enough to capture a 40cm field. The fibers are embedded within a water equivalent polymer substrate that is secured in the LINAC accessory tray. The fibers are coupled to high speed photosensors and front end amplifiers that filter noise and pass each pulse to a high speed analog-to-digital converter. The system components are capable of detecting pulse repetition times shorter than what is delivered by a medical LINAC to ensure true real time data acquisition. Results: The system was able to capture and record the signal from each linac pulse and display the information in real time with no pulse pile up. It was found that the fiber array attenuates 2.65% of the beam which can easily be compensated for in treatment planning. The fibers responded linearly with dose, are independent of clinical beam energies, and are independent of dose rate. Calibration of the system was performed as a function of beam energy, beam size, dose rate, and monitor units to optimize beam fluence error detection. Conclusion: The detector system presented provides true real time in vivo beam monitoring to enhance patient safety and treatment delivery accuracy. Furthermore, the detector can be used for current patient specific QA.

60 APPLIED LIFE SCIENCES↗

Validation for 233U-Fueled Systems in KENO V.a in SCALE 6.2

Validation of the KENO V.a Monte Carlo code has been performed in recent years using benchmark experiments contained in the International Criticality Safety Benchmark Evaluation Project (ICSBEP) Handbook. The models used in these recent validation efforts have been drawn from the Verified, Archived Library of Inputs and Data (VALID). Models must be generated and reviewed by qualified individuals to be added to the VALID library, which leads to high confidence in the models and reduces the probability that apparent validation issues are a result of modeling errors. The contents of the VALID library are somewhat limited because of the effort involved in generating and reviewing models, so no 233U-fueled experiments are included in VALID. A large number of models of 233U experiments have been modeled in the past in support of the criticality safety of 233U in storage at Oak Ridge National Laboratory (ORNL). In June 2016, two midshipmen from the United States Naval Academy were assigned to ORNL, and they reviewed and updated these models for execution in SCALE 6.2. The validation of 233U is of interest because some discrepancies in SCALE results were identified by a beta tester at the Nuclear Energy Agency modeling these systems. These discrepancies were related to a data thinning procedure in the continuous-energy nuclear data process, and had been resolved prior to the release of SCALE 6.2

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

High energy x-ray phase contrast CT using glancing-angle grating interferometers

Purpose: The authors present initial progress toward a clinically compatible x-ray phase contrast CT system, using glancing-angle x-ray grating interferometry to provide high contrast soft tissue images at estimated by computer simulation dose levels comparable to conventional absorption based CT. Methods: DPC-CT scans of a joint phantom and of soft tissues were performed in order to answer several important questions from a clinical setup point of view. A comparison between high and low fringe visibility systems is presented. The standard phase stepping method was compared with sliding window interlaced scanning. Using estimated dose values obtained with a Monte-Carlo code the authors studied the dependence of the phase image contrast on exposure time and dose. Results: Using a glancing angle interferometer at high x-ray energy (∼45 keV mean value) in combination with a conventional x-ray tube the authors achieved fringe visibility values of nearly 50%, never reported before. High fringe visibility is shown to be an indispensable parameter for a potential clinical scanner. Sliding window interlaced scanning proved to have higher SNRs and CNRs in a region of interest and to also be a crucial part of a low dose CT system. DPC-CT images of a soft tissue phantom at exposures in the range typical for absorption based CT of musculoskeletal extremities were obtained. Assuming a human knee as the CT target, good soft tissue phase contrast could be obtained at an estimated absorbed dose level around 8 mGy, similar to conventional CT. Conclusions: DPC-CT with glancing-angle interferometers provides improved soft tissue contrast over absorption CT even at clinically compatible dose levels (estimated by a Monte-Carlo computer simulation). Further steps in image processing, data reconstruction, and spectral matching could make the technique fully clinically compatible. Nevertheless, due to its increased scan time and complexity the technique should be thought of not as replacing, but as complimentary to conventional CT, to be used in specific applications.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

ARM FY2024 Radar Plan

The U.S. Department of Energy (DOE) Atmospheric Radiation Measurement (ARM) user facility’s radar capability aims to provide high-quality radar observations to the scientific community, advancing the understanding of clouds and precipitation processes and ultimately improving climate models. ARM operates radars across a spectrum of frequencies with diverse scanning capacities (Table 1) to meet these scientific goals. The maintenance, operations, and management of these distributed radars at sites in various climate regimes require a substantial staffing commitment. However, the existing staffing resources are constrained, making it impractical to sustain the consistent high-quality operations that are expected by the ARM user community. In response, ARM needs to develop priorities for the radar team each year. This report lays out the forthcoming priorities for Financial Year 2024 (FY24), aiming to establish a structure for the ongoing management of radar operations and data processing.

54 ENVIRONMENTAL SCIENCES↗

A resource of lipidomics and metabolomics data from individuals with undiagnosed diseases

Every year individuals experience symptoms that remain undiagnosed by healthcare providers. In the United States, these rare diseases are defined as a condition that affects fewer than 200,000 individuals. However, there are an estimated 7000 rare diseases, and there are an estimated 25–30 million Americans in total (7.6–9.2% of the population as of 2018) affected by such disorders. The NIH Common Fund Undiagnosed Diseases Network (UDN) seeks to provide diagnoses for individuals with undiagnosed disease. Mass spectrometry-based metabolomics and lipidomics analyses could advance the collective understanding of individual symptoms and advance diagnoses for individuals with heretofore undiagnosed disease. Here, we report the mass spectrometry-based metabolomics and lipidomics analyses of blood plasma, urine, and cerebrospinal fluid from 148 patients within the UDN and their families, as well as from a reference population of over 100 individuals with no known metabolic diseases. The raw and processed data are available to the research community so that they might be useful in the diagnoses of current or future patients suffering from undiagnosed disorders.

60 APPLIED LIFE SCIENCES↗

Deep Optical Switching on Subpicosecond Timescales in an Amorphous Ge Metamaterial

Active nanostructured optical components show promise as potential building blocks for novel light-based computing and data processing architectures. However, nanoscale all-optical switches that have low activation powers and high-contrast ultrafast switching have been elusive so far. Here, pump–probe measurements performed on amorphous-Ge-based micro-resonator metasurfaces that exhibit strong resonant modes in the mid-infrared are reported. Relative change is observed in transmittance of ΔT/T ≈ 1 with picosecond (down to τ ≈ 0.5 ps) free carrier relaxation rates, obtained with very low pump fluences of 50 μJ cm –2 . In this work, these observations are attributed to efficient free carrier promotion, affecting light transmittance via high quality-factor optical resonances, followed by an increased electron–phonon scattering of free carriers due to the amorphous crystal structure of Ge. Full-wave simulations based on a permittivity model that describes free-carrier damping through crystal structure disorder find excellent agreement with the experimental data. These findings offer an efficient and robust platform for all-optical switching at the nanoscale.

36 MATERIALS SCIENCE↗