Search NASA⌕ Search

SEARCH · Search NASA

Results for “simulation types and techniques”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,405 records · Page 78

Automatic Fault Characterization via Abnormality-Enhanced Classification

Enterprise and high-performance computing systems are growing extremely large and complex, employing hundreds to hundreds of thousands of processors and software/hardware stacks built by many people across many organizations. As the growing scale of these machines increases the frequency of faults, system complexity makes these faults difficult to detect and to diagnose. Current system management techniques, which focus primarily on efficient data access and query mechanisms, require system administrators to examine the behavior of various system services manually. Growing system complexity is making this manual process unmanageable: administrators require more effective management tools that can detect faults and help to identify their root causes. System administrators need timely notification when a fault is manifested that includes the type of fault, the time period in which it occurred and the processor on which it originated. Statistical modeling approaches can accurately characterize system behavior. However, the complex effects of system faults make these tools difficult to apply effectively. This paper investigates the application of classification and clustering algorithms to fault detection and characterization. We show experimentally that naively applying these methods achieves poor accuracy. Further, we design novel techniques that combine classification algorithms with information on the abnormality of application behavior to improve detection and characterization accuracy. Our experiments demonstrate that these techniques can detect and characterize faults with 65% accuracy, compared to just 5% accuracy for naive approaches.

97 MATHEMATICS AND COMPUTING↗

On the formulation of species reaction rates in the context of multi-species CFD codes using complex chemistry tabulation techniques

In the standard implementation of tabulated combustion models of the FPI or FGM type, the mean species mass fractions are read from look-up tables as functions of a progress variable, mixture fraction and their variances. In multi-species CFD codes however, the mean thermodynamic properties are deduced from the local mean species mass fractions. The unclosed mean source terms appearing in the latter's transport equations must then be given by the chemistry look-up tables. Two possible formulations for this mean source terms are discussed and compared in the present paper. In the reaction rate (RR) formulation, all mean reaction rates are directly read from a look-up table. In the mass fraction (MF) formulation, only the reaction rate for the progress variable is stored, and mean species source terms are constructed to relax the mean mass fractions towards the value stored in the look-up table. After a detailed description of in particular the MF formulation, simple a priori tests of auto-igniting reactors without convection and diffusion are used to illustrate and discuss the differences between the two formulations. Both formulations are then applied to a RANS simulation of the Cabra et al. burner in the context of a PCM-FPI and of an ADF-PCM model. The reported findings confirm the conclusions from the simple tests, highlighting the definitive advantages of the MF formulation. It ensures an accurate reproduction of auto-ignition delays, species evolutions and equilibriums, at the condition that the relaxation parameter is of the order of a characteristic chemical time. Finally, it is shown that the relaxation's effect is only a second order correction. (author)

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Continuous Fluorescence Depletion Anisotropy Measurement of Protein Rotation

Protein rotation in viscous environments can be measured by fluorescence depletion anisotropy (FDA) which combines long lifetimes of chromophore triplet states with the sensitivity of fluorescence excitation and detection. FDA achieves sensitivity well beyond that attainable by the more common technique of time-resolved phosphorescence anisotropy (TPA). We have now combined benefits of both time-domain and frequency-domain FDA into a single continuous technique (CFDA). Intensity and polarization of a single laser beam are modulated continuously according to a complex, repeating waveform. Fluorescence signals excited from triplet-forming fluorescent probes are digitized over recurring waveform periods by a high-speed signal averager. CFDA experiments typically involve substantial ground state depletion. Thus signals, unlike those of TPA, are not linear in the exciting light intensity and simple data analysis based on such linearity is not appropriate. An exact solution of the coupled diffusion and triplet production/decay equation describing CFDA within individual data points has been combined with simulated annealing optimization to extract triplet and anisotropy decay kinetics from experimental data. Related calculations compare possible excitation waveforms with respect to rotational information provided per fluorescence photon. We present CFDA results for the model system of eosin conjugates of carbonic anhydrase, BSA and immunoglobulin G in 90% glycerol at various temperatures and initial cellular results on eosin-IgE bound to 2H3 cell Type I Fcε receptors. We explore how CFDA reflects rotational parameters of heterogeneous systems and discuss challenges of extending this method to single cell microscopic measurements.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Magnetoacoustic waves propagating along a dense slab and Harris current sheet and their wavelet spectra

Currently, there is a common endeavor to detect magnetoacoustic waves in solar flares. This paper contributes to this topic using an approach of numerical simulations. We studied a spatial and temporal evolution of impulsively generated fast and slow magnetoacoustic waves propagating along the dense slab and Harris current sheet using two-dimensional magnetohydrodynamic numerical models. Wave signals computed in numerical models were used for computations of the temporal and spatial wavelet spectra for their possible comparison with those obtained from observations. It is shown that these wavelet spectra allow us to estimate basic parameters of waveguides and perturbations. It was found that the wavelet spectra of waves in the dense slab and current sheet differ in additional wavelet components that appear in association with the main tadpole structure. These additional components are new details in the wavelet spectrum of the signal. While in the dense slab this additional component is always delayed after the tadpole head, in the current sheet this component always precedes the tadpole head. It could help distinguish a type of the waveguide in observed data. We present a technique based on wavelets that separates wave structures according to their spatial scales. This technique shows not only how to separate the magnetoacoustic waves and waveguide structure in observed data, where the waveguide structure is not known, but also how propagating magnetoacoustic waves would appear in observations with limited spatial resolutions. The possibilities detecting these waves in observed data are mentioned.

79 ASTRONOMY AND ASTROPHYSICS↗

Monte Carlo computed machine-specific correction factors for reference dosimetry of TomoTherapy static beam for several ion chambers

Purpose: To determine k{sub Q{sub m{sub s{sub r,Q{sub o}{sup f{sub m}{sub s}{sub r},f{sub o}}}}}} correction factors for machine-specific reference (msr) conditions by Monte Carlo (MC) simulations for reference dosimetry of TomoTherapy static beams for ion chambers Exradin A1SL, A12; PTW 30006, 31010 Semiflex, 31014 PinPoint, 31018 microLion; NE 2571. Methods: For the calibration of TomoTherapy units, reference conditions specified in current codes of practice like IAEA/TRS-398 and AAPM/TG-51 cannot be realized. To cope with this issue, Alfonso et al. [Med. Phys. 35, 5179-5186 (2008)] described a new formalism introducing msr factors k{sub Q{sub m{sub s{sub r,Q{sub o}{sup f{sub m}{sub s}{sub r},f{sub o}}}}}} for reference dosimetry, applicable to static TomoTherapy beams. In this study, those factors were computed directly using MC simulations for Q{sub 0} corresponding to a simplified {sup 60}Co beam in TRS-398 reference conditions (at 10 cm depth). The msr conditions were a 10 Multiplication-Sign 5 cm{sup 2} TomoTherapy beam, source-surface distance of 85 cm and 10 cm depth. The chambers were modeled according to technical drawings using the egs++ package and the MC simulations were run with the egs{sub c}hamber user code. Phase-space files used as the source input were produced using PENELOPE after simulation of a simplified {sup 60}Co beam and the TomoTherapy treatment head modeled according to technical drawings. Correlated sampling, intermediate phase-space storage, and photon cross-section enhancement variance reduction techniques were used. The simulations were stopped when the combined standard uncertainty was below 0.2%. Results: Computed k{sub Q{sub m{sub s{sub r,Q{sub o}{sup f{sub m}{sub s}{sub r},f{sub o}}}}}} values were all close to one, in a range from 0.991 for the PinPoint chamber to 1.000 for the Exradin A12 with a statistical uncertainty below 0.2%. Considering a beam quality Q defined as the TPR{sub 20,10} for a 6 MV Elekta photon beam (0.661), the additional correction k{sub Q{sub m{sub s{sub r{sub ,Q}{sup f{sub m}{sub s}{sub r}{sub ,}f{sub r}{sub e}{sub f}}}}}} to k{sub Q,Q{sub o}} defined in Alfonso et al. [Med. Phys. 35, 5179-5186 (2008)] formalism was in a range from 0.997 to 1.004.Conclusion: The MC computed factors in this study are in agreement with measured factors for chamber types already studied in literature. This work provides msr correction factors for additional chambers used in reference dosimetry. All of them were close to one (within 1%).

61 RADIATION PROTECTION AND DOSIMETRY↗

A vector-based failure detection and isolation algorithm for a dual fail-operational redundant strapdown inertial measurement unit

A vector-based failure detection and isolation technique for a skewed array of two degree-of-freedom inertial sensors is developed. Failure detection is based on comparison of parity equations with a threshold, and isolation is based on comparison of logic variables which are keyed to pass/fail results of the parity test. A multi-level approach to failure detection is used to ensure adequate coverage for the flight control, display, and navigation avionics functions. Sensor error models are introduced to expose the susceptibility of the parity equations to sensor errors and physical separation effects. The algorithm is evaluated in a simulation of a commercial transport operating in a range of light to severe turbulence environments. A bias-jump failure level of 0.2 deg/hr was detected and isolated properly in the light and moderate turbulence environments, but not detected in the extreme turbulence environment. An accelerometer bias-jump failure level of 1.5 milli-g was detected over all turbulence environments. For both types of inertial sensor, hard-over, and null type failures were detected in all environments without incident. The algorithm functioned without false alarm or isolation over all turbulence environments for the runs tested.

Morrell, Frederick R.↗

Chromosome Aberrations in Human Epithelial Cells Exposed Los Alamos High-Energy Secondary Neutrons: M-BAND Analysis

High-energy secondary neutrons, produced by the interaction of galactic cosmic rays (GCR) with the atmosphere, spacecraft structure and planetary surfaces, contribute a significant fraction to the dose equivalent radiation measurement in crew members and passengers of commercial aviation travel as well as astronauts in space missions. The Los Alamos Nuclear Science Center (LANSCE) neutron facility's 30L beam line (4FP30L-A/ICE House) is known to generate neutrons that simulate the secondary neutron spectrum of the Earth's atmosphere at high altitude. The neutron spectrum is also similar to that measured onboard spacecrafts like the MIR and the International Space Station (ISS). To evaluate the biological damage, we exposed human epithelial cells in vitro to the LANSCE neutron beams with an entrance dose rate of 2.5 cGy/hr, and studied the induction of chromosome aberrations that were identified with multicolor-banding in situ hybridization (mBAND) technique. With this technique, individually painted chromosomal bands on one chromosome allowed the identification of inter-chromosomal aberrations (translocation to unpainted chromosomes) and intra-chromosomal aberrations (inversions and deletions within a single painted chromosome). Compared to our previous results with gamma-rays and 600 MeV/nucleon Fe ions of high dose rate at NSRL (NASA Space Radiation Laboratory at Brookhaven National Laboratory), the neutron data from the LANSCE experiments showed significantly higher frequency of chromosome aberrations. However, detailed analysis of the inversion type revealed that all of the three radiation types in the study induced a low incidence of simple inversions. Most of the inversions in gamma-ray irradiated samples were accompanied by other types of intrachromosomal aberrations but few inversions were accompanied by interchromosomal aberrations. In contrast, neutrons and Fe ions induced a significant fraction of inversions that involved complex rearrangements of both inter- and intrachromosome exchanges. The distribution of damage sites on chromosome 3 was also compared for different radiation types. The breakpoints were randomly localized on chromosome 3 with neutrons and Fe ions exposure, whereas non-random distribution with clustering breakpoints was observed with gamma-rays exposure. The specific fingerprint of neutron radiations on chromosomal aberrations will be discussed.

Hada, M.↗

'In vivo' Dose Measurements in High-Dose-Rate Brachytherapy Treatments for Cervical Cancer: A Project Proposal

The aim of this thesis project is to compare doses calculated from the treatment planning system using computed tomography images, with those measured 'in vivo' by using thermoluminescent dosimeters placed at different regions of the rectum and bladder of a patient during high-dose-rate intracavitary brachytherapy treatment of uterine cervical carcinoma. The experimental dosimeters characterisation and calibration have concluded and the protocol to carry out the 'in vivo' measurements has been established. In this work, the calibration curves of two types of thermoluminescent dosimeters (rods and chips) are presented, and the proposed protocol to measure the 'in vivo' dose is fully described.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Lipophilic ternary complexes in liquid-liquid extraction of trivalent lanthanides

The formation of ternary complexes between lanthanide ions [Nd(III) or Eu(III)], octyl(phenyl)-N,N-diisobutyl-carbamoylmethylphosphine oxide (CMPO), and bis-(2-ethylhexyl)phosphoric acid (HDEHP) was probed by liquid-liquid extraction and spectroscopic techniques. Equilibrium modeling of data for the extraction of Nd(III) or Eu(III) from lactic acid media into n-dodecane solutions of CMPO and HDEHP indicates the predominant extracted species are of the type [Ln(AHA){sub 2}(A)] and [Ln(CMPO)(AHA){sub 2}(A)], where Ln = Nd or Eu and A represents the DEHP{sup -} anion. FTIR (for both Eu and Nd) and visible spectrophotometry (in the case of Nd) indicate the formation of the [Ln(CMPO)(A){sup 3}] complexes when CMPO is added to n-dodecane solutions of the LnA{sub 3} compounds. Both techniques indicate a stronger propensity of CMPO to complex Nd(III) versus Eu(III).

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

N-dimensional non uniform rational B-splines for metamodeling

Non Uniform Rational B-splines (NURBs) have unique properties that make them attractive for engineering metamodeling applications. NURBs are known to accurately model many different continuous curve and surface topologies in 1-and 2-variate spaces. However, engineering metamodels of the design space often require hypervariate representations of multidimensional outputs. In essence, design space metamodels are hyperdimensional constructs with a dimensionality determined by their input and output variables. To use NURBs as the basis for a metamodel in a hyperdimensional space, traditional geometric fitting techniques must be adapted to hypervariate and hyperdimensional spaces composed of both continuous and discontinuous variable types. In this paper, we describe the necessary adaptations for the development of a NURBs-based metamodel called a Hyperdimensional Performance Model or HyPerModel. HyPerModels are capable of accurately and reliably modeling nonlinear hyperdimensional objects defined by both continuous and discontinuous variables of a wide variety of topologies, such as those that define typical engineering design spaces. We demonstrate this ability by successfully generating accurate HyPerModels of 10 trial functions laying the foundation for future work with N-dimensional NURBs in design space applications.

99 GENERAL AND MISCELLANEOUS↗

Endwall heat transfer in the junction region of a circular cylinder normal to a flat plate at 30 and 60 degrees from stagnation point of the cylinder

The objective of this experimental study was to investigate the influence of horseshoe vortex on the heat transfer on a flat plate near the base of a protruding cylinder. The partial shock reflection technique was used to produce the flow Mach number of 0.14 which simulated the mean inlet flow Mach number for the first stage vanes of the turbine after combustor. Fast response thin-film platinum heat gages were used to measure the heat transfer flux for radial distances of 0.75, 0.875, 1.0, 1.125 cylinder diameter. For a low Reynolds number of 20,000, r/D = 0.75, and angular location from the stagnation point = 60 deg, the maximum increase in the heat transfer rate with the cylinder was observed to be approximately 460 percent greater than without the cylinder. On the other hand, the increase in the heat flux for a high Reynolds number of 300,000 was approximately 70 percent greater. For the heat gages located along 30 deg and 60 deg angular locations from the stagnation point, the strong effect of the horseshoe vortex was observed in the junction region. The increase in the heat transfer rate depended on the type of boundary layer and on the boundary layer thickness ahead of the cylinder.

Nagamatsu, H. T.↗

SU-D-BRE-01: A Realistic Breathing Phantom of the Thorax for Testing New Motion Mitigation Techniques with Scanning Proton Therapy

Purpose: A prototype breathing phantom (named LuCa) has been developed which simulates the anatomy and motion of a patient thorax.In this work, we describe the results of the first commissioning tests with LuCa. Methods: The phantom provides a close representation of the human thorax. The lungs,contained within a tissue-equivalent ribcage and skin,are made from a polymer foam,which is inflated and deflated using a custommade ventilator. A tumor is simulated using a wooden ball with cutplanes for placing GafChromic films. The ventilator,controlled with Labview software,simulates a full range of breathing motion types.Commissioning tests were performed to assess its performance using imaging (CT and radiographic) and film dosimetry as follows:i)maximum Tumor excursion at acceptable pressure ranges, ii)tumor Motion repeatability between breathing periods,iii)reproducibility between measurement days,iv)tumor-to-surface motion correlation and v)reproducibility of film positioning in phantom. Results: The phantom can generate repeatable motion patterns with sin{sup 4},sin,breath-hold (tumor amplitude repeatability <0.5mm over 10min),aswell as patient-specific motion types. Maximum excursions of the tumor are 20mm and 14mm for the large and small tumor inserts respectively. Amplitude reproducibility (Coefficient of Variation) averaged at 16% for the workable pressure range over 2 months. Good correlation between tumor and surface motion was found with R{sup 2}=0.92. Reproducibility of film positioning within the thorax was within 0.9mm, and maximum 3° error from the coronal plane. Film measurements revealed that the film repositioning error yields relative errors in the mean dose over the planned target volume (PTV) of up to 2.5% and 4.5% for films at the center and on the edge of the PTV respectively. Conclusion: Commissioning tests have shown that the LuCa phantom can produce tumor motion with excellent repeatability. However,a poorer performance in reproducibility of tumor amplitude for a given peak pressure week-to-week. Film set-up reproducibility is adequate for detection of dosimetric errors resulting from motion of >3%. This work is funded by Swiss National Fund Grants 320030-127569 and 320030-1493942-1.

60 APPLIED LIFE SCIENCES↗

Generation of thermofield double states and critical ground states with a quantum computer

Significance Our experiment prepares two types of nontrivial quantum states on a trapped ion quantum computer: the thermofield double state of the transverse-field Ising model at arbitrary temperature and the quantum critical state of the zero-temperature model. We use techniques motivated by the quantum approximate optimization algorithm, and we implement a hybrid quantum–classical optimization loop to prepare the quantum critical state. Our results pave the way for exploring strongly correlated models at finite temperature and teleportation protocols inspired by black hole physics.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Formation and Reconnection of Electron Scale Current Layers in the Turbulent Outflows of a Primary Reconnection Site

We simulate with 3D particle in cell, the spontaneous formation of turbulent outflows in an initially laminar 3D reconnecting current layer. We observe the formation of many secondary current layers and reconnection sites in the outflow. The approach we follow is to study each individual feature within the turbulent outflow. To identify all clusters of current in the outflow we use a clustering technique widely used in unsupervised machine learning: density-based spatial clustering of applications with noise. Once the clusters are identified we measure their size and compute reconnection indicators to establish which are undergoing reconnection. With this analysis we establish that the size of the current clusters reaches all the way from its initial system scale down to subelectron skin depth scale. We observe that the smaller current clusters are more prone to reconnecting and to releasing energy. We then find the process of reconnection of the smaller current cluster to be of the recently observed electron-only type that leaves the ions essentially unaffected.

79 ASTRONOMY AND ASTROPHYSICS↗

Navier-Stokes simulation of the supersonic combustion flowfield in a ram accelerator

A computational study of the ram accelerator, a ramjet-in-tube device for accelerating projectiles to ultrahigh velocities, is presented. The analysis is performed using a fully implicit TVD scheme that efficiently solves the Reynolds-averaged Navier-Stokes equations and the species continuity equations associated with a finite rate combustion model. Previous analyses of this concept were based on inviscid assumptions. The present results indicate that viscous effects are of primary importance; in all the cases studied, shock-induced combustion always started in the boundary layer. The effects of Mach number, mixture composition, pressure, and turbulence are investigated for various configurations. Two types of combustion processes, one stable and the other unstable, were observed depending on the inflow conditions. In the unstable case, a detonation wave is formed, which propagates upstream and unstarts the ram accelerator. In the stable case, a solution that converges to steady-state is obtained, in which the combustion wave remains stationary with respect to the ram accelerator projectile. The possibility of stabilizing the detonation wave by means of a backward facing step is also investigated. In addition to these studies, two numerical techniques were tested. These two techniques are vector extrapolation to accelerate convergence, and a diagonal formulation that eliminates the expense of inverting large block matrices that arise in chemically reacting flows.

Yungster, Shaye↗

An improved phase shift reconstruction algorithm of fringe scanning technique for X-ray microscopy

The X-ray phase imaging method has been applied to observe soft biological tissues, and it is possible to image the soft tissues by using the benefit of the so-called “Talbot effect” by an X-ray grating. One type of the X-ray phase imaging method was reported by combining an X-ray imaging microscope equipped by a Fresnel zone plate with a phase grating. Using the fringe scanning technique, a high-precision phase shift image could be obtained by displacing the grating step by step and measuring dozens of sample images. The number of the images was selected to reduce the error caused by the non-sinusoidal component of the Talbot self-image at the imaging plane. A larger number suppressed the error more but increased radiation exposure and required higher mechanical stability of equipment. In this paper, we analyze the approximation error of fringe scanning technique for the X-ray microscopy which uses just one grating and proposes an improved algorithm. We compute the approximation error by iteration and substitute that into the process of reconstruction of phase shift. This procedure will suppress the error even with few sample images. The results of simulation experiments show that the precision of phase shift image reconstructed by the proposed algorithm with 4 sample images is almost the same as that reconstructed by the conventional algorithm with 40 sample images. We also have succeeded in the experiment with real data.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Plasmonic Force Propulsion Revolutionizes Nano/Picosatellite Capability

This project investigated a new type of small spacecraft propulsion for attitude control, specifically proximity and precision pointing control. Plasmonic force propulsion uses solar light focused on deep-subwavelength nanostructures to excite strong optical forces that accelerate and expel nanoparticle propellant. The goal of the project was to assess the feasibility of plasmonic force propulsion for nano/pico-satellite applications by evaluating key mission parameters for a nano/pico-satellite using plasmonic force propulsion in a NASA-relevant mission context. We achieved this goal and objective by evaluating plasmonic force propulsion within a NASA mission that required attitude control and precision pointing of a small satellite. We numerically simulated plasmonic force fields with asymmetric/gradient geometry and relevant solar light constraints, predicted nanoparticle velocity, mass flow rate, and resulting propulsion performance (thrust, specific impulse), and evaluated spacecraft position control resolution and pointing precision. Additionally we compared the precision pointing capabilities of plasmonic propulsion, as well as the mass, volume, and power requirements, with other state-of-the-art control techniques, such as reaction wheels and colloid/electrospray electric propulsion. The results are very exciting. Plasmonic force propulsion can significantly enhance the state-of-the-art in small spacecraft position and attitude control by 1-2 orders of magnitude. This is most succinctly shown in the figure below, which compares proximity and attitude control of plasmonic force propulsion (PFP) with other state-of-the-art thruster systems (μCAT, VAT, electrospray). Additionally this figure also shows the proximity and attitude control required for different existing (James Webb Space Telescope, Hubble) and future (LISA and Stellar Imager) NASA missions. While some of these NASA missions are not small spacecraft missions, the requirements serve to illustrate the fact that more precise proximity and attitude control will be required for future NASA science missions. Stellar imager is a proposed NASA missions that requires an extremely high pointing precision of 0.1 milliarcseconds (2.7x10(exp -7) deg.) for an ultraviolet telescope that has over 200× the resolution of the Hubble Space Telescope, is able to take images showing details on the surfaces of other stars, consists of 20-30 small "mirror sats" flying in formation to produce a giant mirror, and requires each mirror-sat to be placed with nanometer precision and control its attitude with milliarcsecond precision.

Rovey, Joshua L.↗

USING THE LEVENBERG-MARQUARDT METHOD FOR SOLUTIONS OF INVERSE TRANSPORT PROBLEMS IN ONE- AND TWO-DIMENSIONAL GEOMETRIES

Determining the components of a radioactive source/shield system using the system's radiation signature, a type of inverse transport problem, is one of great importance in homeland security, material safeguards, and waste management. Here, the Levenberg-Marquardt (or simply 'Marquardt') method, a standard gradient-based optimization technique, is applied to the inverse transport problems of interface location identification, shield material identification, source composition identification, and material mass density identification (both separately and combined) in multilayered radioactive source/shield systems. One-dimensional spherical problems using leakage measurements of neutron-induced gamma-ray lines and two-dimensional cylindrical problems using flux measurements of uncollided passive gamma-ray lines are considered. Gradients are calculated using an adjoint-based differentiation technique that is more efficient than difference formulas. The Marquardt method is iterative and directly estimates unknown interface locations, source isotope weight fractions, and material mass densities, while the unknown shield material is identified by estimating its macroscopic gamma-ray cross sections. Numerical test cases illustrate the utility of the Marquardt method using both simulated data that are perfectly consistent with the optimization process and realistic data simulated by Monte Carlo.

98 NUCLEAR DISARMAMENT, SAFEGUARDS, AND PHYSICAL P↗