Search NASA⌕ Search

SEARCH · Search NASA

Results for “Cold”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,423 records · Page 79

Power coupled to the slow wave resonance cone in cold plasma

We consider the power coupled to the plasma from a cylindrical source emitting resonance cones, propagative slow waves which exist in low density magnetized plasmas when the signs of the Stix parameters S and P differ. In this work, we calculate this power for the first time for any collisionality, and show that it remains finite in the cold collisionless limit, even as the radiofrequency electric field itself, and the associated power absorption density, is singular. We give the main parameter dependencies of the coupled power.

Tierens, Wouter [ORNL] (ORCID:0000000269798140)↗

Production of a slit skimmer for use in cold supersonic molecular beams

Cold molecular beams generated by skimming pulsed supersonic gas expansions normally employ conical skimmers. The use of slit shaped skimmers instead of conical skimmers can afford significant signal enhancements. At this time, however, slit shaped skimmers are not available commercially. We describe a straightforward method for producing functional slit skimmers.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Long-pulse arc-discharge plasma source with cold cathode for diagnostic neutral beam injector

Long-pulse cold cathode arc-discharge plasma generators have been successfully used as high-quality hydrogen ion sources for plasma diagnostic neutral beams. One of the main advantages of this type of plasma source is a high proton fraction (80%-90%). However, the lifetime of the plasma source is limited due to intensive electrode's erosion, especially at the cathode region. An optimized design of the cathode and the nearest electrodes is found which reduces the erosion and allows us to increase the pulse length. The plasma source produces the extracted ion current up to 3 A at a low angular divergence, and at the pulse duration up to 2 s.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Equation of State and Pairing Gaps in Cold Atoms and Low-Density Neutron Matter

Cold Atom experiments provide a direct experimental test of the properties of neutron matter at extremely low densities, as is expected to be found in the crusts of neutron stars. These systems are very unusual in that the pairing gap is of the order of the Fermi energy, rather than the very small fraction typical for superfluids or superconductors. We compare the equation of state and the pairing gaps in these systems.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Cold r-Process in Supernovae

The r-process in a low temperature environment is explored, in which the neutron emission by photodisintegration does not play a role. A semi-analytic neutrino-driven wind model is utilized for this purpose. The temperature in a supersonically expanding outflow can quickly drop to a few 10{sup 8} K, where the (n,{gamma})-({gamma},n) equilibrium is never achieved during the heavy r-nuclei synthesis. In addition, the neutron capture competes with the {beta}-decay owing to the low matter density. Despite such non-standard physical conditions, a solar-like r-process abundance curve can be reproduced. The cold r-process predicts, however, the low lead production compared to that expected in the traditional r-process conditions, which can be a possible explanation for the low lead abundances found in a couple of r-process-rich Galactic halo stars.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Cold microplasma plume produced by a compact and flexible generator at atmospheric pressure

In this letter, we report a cold microplasma generator at atmospheric pressure excited at 1 kHz in a pin to hole-electrode configuration by using soft materials partly. A nitrogen plasma plume with a length of more than 5 cm can be produced at low electrical power of 0.7 W without high feed gas pressure. The generator exhibits a compact structure with flexible property, which is suitable for treating thermally sensitive materials and biomedical materials, especially for delicate objects in an irregular confined space. Optical emission spectroscopy is used to spatially identify excited species in plasma plume.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

A simple cold Ar plasma jet generated with a floating electrode at atmospheric pressure

An experimental study is presented of a cold atmospheric Ar plasma jet with distinct advantages of low-working voltage and high plasma stability. To effectively improve the performance of the jet, a pair of pin electrodes with one floating in the air is applied. Variation in the applied voltage and/or the Ar gas flow causes the transition of the jet plasma from ignition, through stable plume to an unstable stage. The characteristics of the jet discharge are also studied by means of the electrical and spectroscopic diagnosis.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Stochastic optimization of a cold atom experiment using a genetic algorithm

We employ an evolutionary algorithm to automatically optimize different stages of a cold atom experiment without human intervention. This approach closes the loop between computer based experimental control systems and automatic real time analysis and can be applied to a wide range of experimental situations. The genetic algorithm quickly and reliably converges to the most performing parameter set independent of the starting population. Especially in many-dimensional or connected parameter spaces, the automatic optimization outperforms a manual search.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Stability of Non-Neutral Plasma Cylinder Consisting of Magnetized Cold Electrons and of Small Density Fraction of Ions Born at Rest: Non-Local Analysis

The non-local stability problem of the plasma cylinder, filled with 'cold' magnetized rigidly rotating electrons, and a small density fraction of ions, is solved. The ions are supposed to be born at rest by ionization of background gas. The study is based on the kinetic description of ions. The equilibrium distribution function, taking into account the peculiarity of ions birth, is used. The radial electric field is caused by space charge of non-neutral plasma. The dispersion equation for plasma eigen frequencies is obtained analytically. It is valid within the total admissible range of values of electric and magnetic fields. Normalized eigen frequencies {omega}'/{omega}{sub i} are calculated for the basic azimuth mode m = 1({omega}' {omega}-m{omega}{sub i}{sup +}, {omega}{sub +} = (-{omega}{sub ci}+{omega}{sub i})/2, {omega}{sub i} ({omega}{sub ci}{sup 2}-4eE{sub r}/m{sub i}r){sup 1/2} is called the 'modified' ion cyclotron (MIC) frequency), for the density fraction of ions of atomic nitrogen f N{sub i}/n{sub e} = 0,01 and are presented in graphic form versus parameter 2{omega}{sub pe}{sup 2}/{omega}{sub ce}{sup 2}. The spectra of oscillations {omega}'/{omega}{sub i} consist of the family of electron Trivel-piece--Gould (TG) modes and of the families of MIC modes. The frequencies of MIC modes are located in a small vicinity of harmonics of the MIC frequency {omega}{sub i} above and below the harmonic. The TG modes in non-neutral plasma fall in the region of MIC frequencies {omega}{sub i} and interact strongly with MIC modes. The slow TG modes become unstable near the crossings with non-negative harmonics of MIC frequencies. The instabilities have a resonant character. The lowest radial TG mode has a maximum growth rate at crossing with a zero harmonic of {omega}{sub i} ((Im {omega}'/{omega}{sub i}){sub max}{approx_equal}0,074). The growth rates of MIC modes are much lower ((Im {omega}'/{omega}{sub i}){sub max} < or approx. 0,002). Their instability has a threshold character. The instabilities of TG and MIC modes take place mainly at the values of parameter 2{omega}{sub pe}{sup 2}/{omega}{sub ce}{sup 2}, corresponding to strong radial electric fields ({omega}{sub ci}{sup 2}<<|eE{sub r}/m{sub i}r|), in which the ions are unmagnetized. The oscillations of small amplitude are seen on some frequency dependencies of MIC modes. They are similar to oscillations on dispersion curves of electron waves in metals and are caused by the similarity between the ion equilibrium distribution function and the degenerate Fermi--Dirac one. The results obtained give the solution to the stability problem discussed by R.H. Levy, J.D. Daugherty and O. Buneman [Phys. Fl. 12, 2616-2629 (1969)] for a special case of plasma bounding directly with metal casing and possessing the volumetric eigen modes only.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Cold-target recoil-ion momentum spectroscopy for diagnostics of high harmonics of the extreme-ultraviolet free-electron laser light source at SPring-8

We have developed a cold-target recoil-ion momentum spectroscopy apparatus dedicated to the experiments using the extreme-ultraviolet light pulses at the free-electron laser facility, SPring-8 Compact SASE Source test accelerator, in Japan and used it to measure spatial distributions of fundamental, second, and third harmonics at the end station.

43 PARTICLE ACCELERATORS↗

Effect of energetic electrons on near-wall sheath voltage in the cathode region of a cold cathode direct current discharge

It is experimentally demonstrated that energetic electrons originating from the cathode or produced in volumetric processes in the cathode region of a cold cathode direct current discharge can create a large potential drop in the near-wall sheath. This voltage drop may be much greater than kT{sub e}/e (where k is the Boltzmann constant, T{sub e} is the electron temperature, and e is the electron charge). Due to the large near-wall sheath voltage, slow and moderately energetic electrons cannot reach the wall and move toward the anode. Application of additional potentials to the wall can change the amount of energetic electrons reaching the wall. This effect can be used for regulation of the near-cathode plasma and near-wall sheath properties and thus may be useful in technical applications.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Communications: Development and characterization of a source of rotationally cold, enriched para-H{sub 3}{sup +}

In an effort to develop a source of H{sub 3}{sup +} that is almost entirely in a single quantum state (J=K=1), we have successfully generated a plasma that is enriched to {approx}83% in para-H{sub 3}{sup +} at a rotational temperature of 80 K. This enrichment is a result of the nuclear spin selection rules at work in hydrogenic plasmas, which dictate that only para-H{sub 3}{sup +} will form from para-H{sub 2}, and that para-H{sub 3}{sup +} can be converted to ortho-H{sub 3}{sup +} by subsequent reaction with H{sub 2}. This is the first experimental study in which the H{sub 2} and H{sub 3}{sup +} nuclear spin selection rules have been observed at cold temperatures. The ions were produced from a pulsed solenoid valve source, cooled by supersonic expansion, and interrogated via continuous-wave cavity ringdown spectroscopy.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Effect of high Xe-concentration in a plasma display panel with a SrCaO cold cathode

We present here measurements of high Xe-contents plasma display panel (PDP) with SrCaO cold cathode. Luminous efficacy ({eta}) shows a two-step increase with Xe-concentration in Ne/Xe gas mixture: {eta} drastically increases up to Xe-concentration of 30% (Xe: 30%), and then attains 5 lm/W at the highest Xe-concentration of Xe: 100%. The high performance PDP with Xe: 100% can be operated at low applied voltage between 230 and 377 V due to the high secondary electron emission from the SrCaO cathode. Emission measurements clearly show the change in discharge characteristics at Xe: 30%, where the discharge changes from a Ne/Xe mixture discharge to an almost pure Xe discharge, and the vacuum ultraviolet (VUV) radiation from the combination of resonance and excimer radiations to only excimer radiation. Theoretical analysis solving Boltzmann equation for electron demonstrates that increasing Xe-concentration enhances the collision frequency for electron impact excitation directly from ground state to lower levels concerned with the VUV radiation, resulting in a drastic increase in luminous efficacy up to Xe: 30%. Also, one-dimensional fluid simulation of a Ne/Xe dielectric barrier discharge clearly shows that a combination of high secondary electron emission cathode and high Xe-concentration is quite effective for high VUV radiation efficiency because it induces a drastic increase in electron-heating efficiency.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Strangeness in the Nucleon, Cold Dark Matter in the Universe, and Neutrino Scattering off Liquid Argon

The strangeness content of the nucleon and the contribution of strange quarks to various nucleon quantum numbers, besides being of fundamental interest, also affects calculations of cross sections of processes that are important in searches for new physics. Here we focus on direct searches for cold dark matter, in the scenario in which the lightest supersymmetric neutral particle dominates the CDM density in the universe and point out that interpretation of searches, as well as the choice of optimal materials for future experiments, are hobbled by uncertainties in the contribution of strange quarks to the nucleon spin. We show how a future low-energy neutrino experiment using a liquid-Ar TPC can make important contributions in determining this quantity with much better precision and reduced theoretical uncertainties.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

A new tandem mass spectrometer for photofragment spectroscopy of cold, gas-phase molecular ions

We present here the design of a new tandem mass spectrometer that combines an electrospray ion source with a cryogenically cooled ion trap for spectroscopic studies of cold, gas-phase ions. The ability to generate large ions in the gas phase without fragmentation, cool them to {approx}10 K in an ion trap, and perform photofragment spectroscopy opens up new possibilities for spectroscopic characterization of large biomolecular ions. The incorporation of an ion funnel, together with a number of small enhancements, significantly improves the sensitivity, signal stability, and ease of use compared with the previous instrument built in our laboratory.

43 PARTICLE ACCELERATORS↗