Calibration of combined bending-torsion fatigue reliability data reduction
The combined bending-torsion fatigue reliability research machines are described. Three such machines are presently in operation. The calibration of these machines is presented in depth. Fatigue data generated with these machines for SAE 4340 steel grooved specimens subjected to reversed bending and steady torque loading are given. The data reduction procedure is presented. Finally, some comments are made about notch sensitivity and stress concentration as applied to combined fatigue.