Search NASA⌕ Search

SEARCH · Search NASA

Results for “Constructal method”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,423 records · Page 79

Supersymmetric factorization yields exact solutions to the molecular Stark-effect problem for stretched states

By invoking supersymmetry, we found a condition under which the Stark-effect problem for a polar and polarizable molecule subject to nonresonant electric fields becomes exactly solvable for the |J-tilde=m,m> family of stretched states. The analytic expressions for the wave function and eigenenergy and other expectation values allow one to readily reverse-engineer the problem of finding the values of the interaction parameters required for creating quantum states with preordained characteristics. The method also allows the construction of families of isospectral potentials, realizable with combined fields.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Stability of the particle-hole Pfaffian state and the 5 2 -fractional quantum Hall effect

Here we present a method for the exact construction of the fully particle-hole symmetric Pfaffian (PH-Pfaffian) ground state and its charged excitations on a sphere. We adopt the Moore-Read state, but with a nonholomorphic pairing component as in previous studies, and project it to the lowest Landau level. We study the energetics as well as other properties of these states and find that in a pure system interacting with the Coulomb forces the PH-Pfaffian cannot compete with either the Moore-Read state or its particle-hole conjugate, the anti-Pfaffian state, as an explanation for the 5/2 effect.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Quantum Hall wave functions on the torus

We present explicit expressions for a large set of hierarchy wave functions on the torus. Included are the Laughlin states, the states in the positive Jain series, and recently observed states at, e.g., {nu}=4/11. The techniques we use constitute a nontrivial extension of the conformal field theory methods developed earlier to construct the corresponding wave functions in disk geometry.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Diabatic paths through the scission point in nuclear fission

An outstanding problem in the theory of nuclear fission is to understand the Hamiltonian dynamics at the scission point. In this work the fissioning nucleus is modeled in self-consistent mean-field theory as a set of generator coordinate method (GCM) configurations passing through the scission point. In contrast to previous methods, the configurations are constructed in the Hartree-Fock approximation with axially symmetric mean fields and using the K -partition numbers as additional constraints. The goal of this work is to find paths through the scission point where the overlaps between neighboring configurations are large. A measure of distance along the path is proposed that is insensitive to the division of the path into short segments. For most of the tested K partitions two shape degrees of freedom are adequate to define smooth paths. However, some of the configurations and candidate paths have sticking points where there are substantial changes in the many-body wave function, especially if quasiparticle excitations are present. The excitation energy deposited in fission fragments arising from thermal excitations in the pre-scission configurations is determined by tracking orbital occupation numbers along the scission paths. This allows us to assess the validity of the well-known scission-point statistical model, in which the scission process is assumed to be fully equilibrated up to the separated fission fragments. The nucleus 236 U is taken as a representative example in the calculations.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Oscillating p-branes

Coset methods are used to construct the action describing the dynamics associated with the spontaneous breaking of the Poincare symmetries of D dimensional space-time due to the embedding of a p-brane with codimension N=D-p-1. The resulting world volume action is an ISO(1,p+N) invariant generalization of the Nambu-Goto action in d=p+1 dimensional space-time. Analogous results are obtained for an anti-de Sitter (AdS) p-brane with codimension N embedded in D dimensional AdS space, yielding an SO(2,p+N) invariant version of the Nambu-Goto action in d=p+1 dimensional space-time. Attention is focused on a supersymmetric extension of the D=6 Minkowski space case with an embedded p=3 brane; a particular realization of which is provided by a non-BPS vortex. Here both the Nambu-Goto-Akulov-Volkov action and its dual tensor form are presented.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Eighth-order vacuum-polarization function formed by two light-by-light-scattering diagrams and its contribution to the tenth-order electron g-2

We have evaluated the contribution to the anomalous magnetic moment of the electron from six tenth-order Feynman diagrams which contain eighth-order vacuum-polarization function formed by two light-by-light-scattering diagrams connected by three photons. The integrals are constructed by two different methods. In the first method the subtractive counter terms are used to deal with ultraviolet (UV) singularities together with the requirement of gauge invariance. In the second method, the Ward-Takahashi identity is applied to the light-by-light-scattering amplitudes to eliminate UV singularities. Numerical evaluation confirms that the two methods are consistent with each other within their numerical uncertainties. Combining the two results statistically and adding small contribution from the muons and/or tau leptons, we obtain 0.000 399 9 (18) ({alpha}/{pi}){sup 5}. We also evaluated the contribution to the muon g-2 from the same set of diagrams and found -1.263 44 (14) ({alpha}/{pi}){sup 5}.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Dyonic giant magnons in CP{sup 3}: Strings and curves at finite J

This paper studies giant magnons in AdS{sub 4}xCP{sup 3} using both the string sigma model and the algebraic curve. We complete the dictionary of solutions by finding the dyonic generalization of the CP{sup 1} string solution, which matches the 'small' giant magnon in the algebraic curve, and by pointing out that the solution recently constructed by the dressing method is the 'big' giant magnon. We then use the curve to compute finite-J corrections to all cases, which for the nondyonic cases always match the Arutyunov-Frolov-Zamaklar result. For the dyonic RP{sup 3} magnon we recover the S{sup 5} answer, but for the small and big giant magnons we obtain new corrections.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Kadanoff-Baym equations with non-Gaussian initial conditions: The equilibrium limit

The nonequilibrium dynamics of quantum fields is an initial-value problem, which can be described by Kadanoff-Baym equations. Typically, and, in particular, when numerical solutions are demanded, these Kadanoff-Baym equations are restricted to Gaussian initial states. However, physical initial states are non-Gaussian correlated initial states. In particular, renormalizability requires the initial state to feature n-point correlations that asymptotically agree with the vacuum correlations at short distances. In order to identify physical nonequilibrium initial states, it is therefore a precondition to describe the vacuum correlations of the interacting theory within the nonequilibrium framework. In this paper, Kadanoff-Baym equations for non-Gaussian correlated initial states describing vacuum and thermal equilibrium are derived from the 2PI effective action. A diagrammatic method for the explicit construction of vacuum and thermal initial correlations from the 2PI effective action is provided. We present numerical solutions of Kadanoff-Baym equations for a real scalar {phi}{sup 4} quantum field theory, which take the thermal initial four-point correlation as the leading non-Gaussian correction into account. We find that this minimal non-Gaussian initial condition yields an approximation to the complete equilibrium initial state that is quantitatively and qualitatively significantly improved as compared to Gaussian initial states.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Quantum interactions between nonperturbative vacuum fields

We develop an approach to investigate the nonperturbative dynamics of quantum field theories, in which specific vacuum field fluctuations are treated as the low-energy dynamical degrees of freedom, while all other vacuum field configurations are explicitly integrated out from the path integral. We show how to compute the effective interaction between the vacuum field degrees of freedom both perturbatively (using stochastic perturbation theory) and fully nonperturbatively (using lattice field theory simulations). The present approach holds to all orders in the couplings and does not rely on the semiclassical approximation.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Reliable semiclassical computations in QCD

We revisit the question of whether or not one can perform reliable semiclassical QCD computations at zero temperature. We study correlation functions with no perturbative contributions, and organize the problem by means of the operator product expansion, establishing a precise criterion for the validity of a semiclassical calculation. For N{sub f}>N, a systematic computation is possible; for N{sub f}<N, it is not. N{sub f}=N is a borderline case. In our analysis, we see explicitly the exponential suppression of instanton effects at large N. As an application, we describe a test of QCD lattice gauge theory computations in the chiral limit.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Spectral representations of neutron-star equations of state

Methods are developed for constructing spectral representations of cold (barotropic) neutron-star equations of state. These representations are faithful in the sense that every physical equation of state has a representation of this type and conversely every such representation satisfies the minimal thermodynamic stability criteria required of any physical equation of state. These spectral representations are also efficient, in the sense that only a few spectral coefficients are generally required to represent neutron-star equations of state quiet accurately. This accuracy and efficiency is illustrated by constructing spectral fits to a large collection of 'realistic' neutron-star equations of state.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Convolutional Dictionary Regularizers for Tomographic Inversion

There has been a growing interest in the use of data-driven regularizers to solve inverse problems associated with computational imaging systems. The convolutional sparse representation model has recently gained attention, driven by the development of fast algorithms for solving the dictionary learning and sparse coding problems for sufficiently large images and data sets. Nevertheless, this model has seen very limited application to tomographic reconstruction problems. In this paper, we present a model-based tomographic reconstruction algorithm using a learnt convolutional dictionary as a regularizer. The key contribution is the use of a data-dependent weighting scheme for the l 1 regularization to construct an effective denoising method that is integrated into the inversion using the Plug-and-Play reconstruction framework. Using simulated data sets we demonstrate that our approach can improve performance over traditional regularizers based on a Markov random field model and a patch-based sparse representation model for sparse and limited-view tomographic data sets.

Singanallur Vaidyanathan, Venkatakrishnan↗

A modern concept of Lagrangian hydrodynamics

Here, we offer a modern interpretation of Lagrangian hydrodynamics as employed in Lagrangian simulations of compressible fluid flow. Our main result is to show that artificial viscosity, traditionally viewed as a numerical artifice to control unphysical oscillations in flows with shocks, actually represents a physical process and is necessary to derive accurate simulations in any compressible flow. We begin by reviewing the origins of two numerical devices, artificial viscosity and finite-volume methods. We proceed to construct a mathematical (PDE) model that incorporates those numerics and in which a new length scale, the observer, arises representing the discretization. Associated with that length scale, there are new inviscid fluxes that are the artificial viscosity as first formulated by Richtmyer and an artificial heat flux postulated by Noh but typically not included in Lagrangian codes. We discuss the connection of our results to bivelocity hydrodynamics. We conclude with some speculation as to the direction of future developments in multidimensional Lagrangian codes as computers get faster and have larger memories.

97 MATHEMATICS AND COMPUTING↗

Technical Note: Potential errors in optical density measurements due to scanning side in EBT and EBT2 Gafchromic film dosimetry

Purpose: The purpose of this study is to determine the effect on the measured optical density of scanning on either side of a Gafchromic EBT and EBT2 film using an Epson (Epson Canada Ltd., Toronto, Ontario) 10000XL flat bed scanner. Methods: Calibration curves were constructed using EBT2 film scanned in landscape orientation in both reflection and transmission mode on an Epson 10000XL scanner. Calibration curves were also constructed using EBT film. Potential errors due to an optical density difference from scanning the film on either side (''face up'' or ''face down'') were simulated. Results: Scanning the film face up or face down on the scanner bed while keeping the film angular orientation constant affects the measured optical density when scanning in reflection mode. In contrast, no statistically significant effect was seen when scanning in transmission mode. This effect can significantly affect relative and absolute dose measurements. As an application example, the authors demonstrate potential errors of 17.8% by inverting the film scanning side on the gamma index for 3%--3 mm criteria on a head and neck intensity modulated radiotherapy plan, and errors in absolute dose measurements ranging from 10% to 35% between 2 and 5 Gy. Conclusions: Process consistency is the key to obtaining accurate and precise results in Gafchromic film dosimetry. When scanning in reflection mode, care must be taken to place the film consistently on the same side on the scanner bed.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

TU-F-17A-03: A 4D Lung Phantom for Coupled Registration/Segmentation Evaluation

Purpose: Coupling the processes of segmentation and registration (regmentation) is a recent development that allows improved efficiency and accuracy for both steps and may improve the clinical feasibility of online adaptive radiotherapy. Presented is a multimodality animal tissue model designed specifically to provide a ground truth to simultaneously evaluate segmentation and registration errors during respiratory motion. Methods: Tumor surrogates were constructed from vacuum sealed hydrated natural sea sponges with catheters used for the injection of PET radiotracer. These contained two compartments allowing for two concentrations of radiotracer mimicking both tumor and background signals. The lungs were inflated to different volumes using an air pump and flow valve and scanned using PET/CT and MRI. Anatomical landmarks were used to evaluate the registration accuracy using an automated bifurcation tracking pipeline for reproducibility. The bifurcation tracking accuracy was assessed using virtual deformations of 2.6 cm, 5.2 cm and 7.8 cm of a CT scan of a corresponding human thorax. Bifurcations were detected in the deformed dataset and compared to known deformation coordinates for 76 points. Results: The bifurcation tracking accuracy was found to have a mean error of −0.94, 0.79 and −0.57 voxels in the left-right, anterior-posterior and inferior-superior axes using a 1×1×5 mm3 resolution after the CT volume was deformed 7.8 cm. The tumor surrogates provided a segmentation ground truth after being registered to the phantom image. Conclusion: A swine lung model in conjunction with vacuum sealed sponges and a bifurcation tracking algorithm is presented that is MRI, PET and CT compatible and anatomically and kinetically realistic. Corresponding software for tracking anatomical landmarks within the phantom shows sub-voxel accuracy. Vacuum sealed sponges provide realistic tumor surrogate with a known boundary. A ground truth with minimal uncertainty is thus realized that can be used for comparing the performance of registration and segmentation algorithms.

60 APPLIED LIFE SCIENCES↗

SU-E-T-431: Feasiblity of Using CT Scout Images for 2D LDR Brachytherpay Planning

Purpose: i) To show the feasibility of using CT scout images for 2D low-dose rate brachytherapy planning with BrachyVision (version 10.4); ii) to show their advantages and disadvantages over DRRs. Methods: A phantom was constructed to house a Fletcher-Suite applicator. The phantom is made of Styrofoam with metal BBs positioned at well-defined separations. These markers are used to assess the image distortion in the scout images. Unlike DRRs, scout images are distorted only in the direction normal to the couch direction; therefore, they needed to be scaled unidirectionally prior to importing into BrachyVision. In addition to confirming the scaling is performed correctly by measuring distances between well-positioned BB, we also compare a LDR plan using scout images to a 3D CT-based plan. Results: There is no distortion of the image along the couch direction due to the collimation of the CT scanner. The distortion in the transverse plane can be corrected by multiplying by the ratio of distances between source-to-isocenter and source-to-detector. The results show the distance separations between BBs as measured in scout images and by a caliber are within a few millimeters. Dosimetrically, the difference between the dose rates to points A and B based on scout images and on 3D CT are less than a few percents. The accuracy can be improved by correcting for the distortion on the transverse plane. Conclusion: It is possible to use CT scout images for 2D planning in BrachyVision. This is an advantage because scout images have no metal artifacts often present in CT images or DRRs. Another advantage is the lack of distortion in the couch direction. One major disadvantage is that the image distortion due to beam divergence can be large. This is due to the inherent short distance between source-to-isocenter and source-to-detector on a CT scanner.

60 APPLIED LIFE SCIENCES↗

SU-F-J-73: Simple Approach for Quantification of Metal Artifact Reduction Capabalities of Dual-Energy CT

Purpose: To present a simple method for quantification of dual-energy CT metal artifact reduction capabilities Methods: A phantom was constructed from solid water and a steel cylinder. Solid water is commonly used for radiotherapy QA, while steel cylinders are readily available in hardware stores. The phantom was scanned on Siemens Somatom 64-slice dual-energy CT system. Three CTs were acquired at energies of 80kV (low), 120kV (nominal), and 140kV (high). The low and high energy acquisitions were used to generate dual-energy (DE) monoenergetic image sets, which also utilized metal artifact reduction algorithm (Maris). Several monoenergetic DE image sets, ranging from 70keV to 190keV were generated. The size of the metal artifact was measured by two different approaches. The first approach measured the distance from the center of the steel cylinder to a location with nominal (undisturbed by metal) HU value for the 120kV, DE 70keV, and DE 190keV image sets. In the second approach, the distance from the center of the cylinder to the edge of the air pocket for the above mentioned three image sets was measured. Results: The DE 190keV synthetic image set demonstrated the largest reduction of the metal artifacts. The size of the artifact was more than three times the actual size of the milled hole in the solid water in the DE 190keV, as compared to more than 7.5 times larger as estimated from the 120kV uncorrected image Conclusion: A simple phantom for quantification of dual-energy CT metal artifact reduction capabilities was presented. This inexpensive phantom can be easily built from components available in every radiation oncology department. It allows quick assessment and quantification of the properties of different metal artifact reduction algorithms, available on modern dual-energy CT scanners.

60 APPLIED LIFE SCIENCES↗

SU-F-T-441: Dose Calculation Accuracy in CT Images Reconstructed with Artifact Reduction Algorithm

Purpose: Accuracy of radiotherapy dose calculation in patients with surgical implants is complicated by two factors. First is the accuracy of CT number, second is the dose calculation accuracy. We compared measured dose with dose calculated on CT images reconstructed with FBP and an artifact reduction algorithm (OMAR, Philips) for a phantom with high density inserts. Dose calculation were done with Varian AAA and AcurosXB. Methods: A phantom was constructed with solid water in which 2 titanium or stainless steel rods could be inserted. The phantom was scanned with the Philips Brillance Big Bore CT. Image reconstruction was done with FBP and OMAR. Two 6 MV single field photon plans were constructed for each phantom. Radiochromic films were placed at different locations to measure the dose deposited. One plan has normal incidence on the titanium/steel rods. In the second plan, the beam is at almost glancing incidence on the metal rods. Measurements were then compared with dose calculated with AAA and AcurosXB. Results: The use of OMAR images slightly improved the dose calculation accuracy. The agreement between measured and calculated dose was best with AXB and image reconstructed with OMAR. Dose calculated on titanium phantom has better agreement with measurement. Large discrepancies were seen at points directly above and below the high density inserts. Both AAA and AXB underestimated the dose directly above the metal surface, while overestimated the dose below the metal surface. Doses measured downstream of metal were all within 3% of calculated values. Conclusion: When doing treatment planning for patients with metal implants, care must be taken to acquire correct CT images to improve dose calculation accuracy. Moreover, great discrepancies in measured and calculated dose were observed at metal/tissue interface. Care must be taken in estimating the dose in critical structures that come into contact with metals.

60 APPLIED LIFE SCIENCES↗