Accelerating Large-Format Metal Additive Manufacturing: How Controls R&D is Driving Speed, Scale, and Efficiency

This article highlights work at Oak Ridge National Laboratory’s Manufacturing Demonstration Facility to develop closed-loop, feedback control for laser-wire based Directed Energy Deposition, a form of metal Big Area Additive Manufacturing (m-BAAM), a process being developed in partnership with GKN Aerospace specifically for the production of Ti-6Al-4V pre-forms for aerospace components. A large-scale structural demonstrator component is presented as a case-study in which not just control, but the entire 3D printing workflow for m-BAAM is discussed in detail, including design principles for large-format metal AM, toolpath generation, parameter development, process control, and system operation, as well as post-print net-shape geometric analysis and finish machining. In terms of control, a multi-sensor approach has been utilized to measure both layer height and melt pool size, and multiple modes of closed-loop control have been developed to manipulate process parameters (laser power, print speed, deposition rate) to control these variables. Layer height control and melt pool size control have yielded excellent local (intralayer) and global (component-level) geometry control, and the impact of melt pool size control in particular on thermal gradients and material properties is the subject of continuing research. Further, these modes of control have allowed the process to advance to higher deposition rates (exceeding 7.5 lb/hr), larger parts (1-meter scale), shorter build times, and higher overall efficiency. The control modes are examined individually, highlighting their development, demonstration, and lessons learned, and it is shown how they operate concurrently to enable the printing of a large-scale, near net shape Ti-6Al-4V component.

Gibson, Brian↗

Synthesis Study on Transitions in Signal Infrastructure and Control Algorithms for Connected and Automated Transportation

Documenting existing state of practice is an initial step in developing future control infrastructure to be co-deployed for heterogeneous mix of connected and automated vehicles with human drivers while leveraging benefits to safety, congestion, and energy. With advances in information technology and extensive deployment of connected and automated vehicle technology anticipated over the coming decades, cities globally are making efforts to plan and prepare for these transitions. CAVs not only offer opportunities to improve transportation systems through enhanced safety and efficient operations of vehicles. There are also significant needs in terms of exploring how best to leverage vehicle-to-vehicle (V2V) technology, vehicle-to-infrastructure (V2I) technology and vehicle-to-everything (V2X) technology. Both Connected Vehicle (CV) and Connected and Automated Vehicle (CAV) paradigms feature bi-directional connectivity and share similar applications in terms of signal control algorithm and infrastructure implementation. The discussion in our synthesis study assumes the CAV/CV context where connectivity exists with or without automated vehicles. Our synthesis study explores the current state of signal control algorithms and infrastructure, reports the completed and newly proposed CV/CAV deployment studies regarding signal control schemes, reviews the deployment costs for CAV/AV signal infrastructure, and concludes with a discussion on the opportunities such as detector free signal control schemes and dynamic performance management for intersections, and challenges such as dependency on market adaptation and the need to build a fault-tolerant signal system deployment in a CAV/CV environment. The study will serve as an initial critical assessment of existing signal control infrastructure (devices, control instruments, and firmware) and control schemes (actuated, adaptive, and coordinated-green wave). Also, the report will help to identify the future needs for the signal infrastructure to act as the nervous system for urban transportation networks, providing not only signaling, but also observability, surveillance, and measurement capacity. The discussion of the opportunities space includes network optimization and control theory perspectives, and the current states of observability for key system parameters (what can be detected, how frequently can it be reported) as well as controllability of dynamic parameters (this includes adjusting not only the signal phase and timing, but also the ability to alter vehicle trajectories through information or direct control). The perspective of observability and controllability of the dynamic systems provides an appropriate lens to discuss future directions as CAV/CV become more prevalent in the future.

33 ADVANCED PROPULSION SYSTEMS↗

Modular Controllable Transformers (MCT)

Large Power Transformers (LPTs) are at the heart of the electricity infrastructure and are critical pieces in today’s grid. Aging assets, long turn-around times, transportation delays and dependence on foreign manufacturing for these components have created conditions for points of failure across the system. Moreover, there is no available dynamic control on these passive sections of the grid. For all the automation embedded on the low voltage side of the low voltage side of the system there is absolutely no flexibility on the high voltage side. Changes in power flow patterns are brought about by altering dispatch patterns for generators which requires a coordinated effort and is often time consuming. Traditional FACTS based approaches such as UPFC or HVDC light involve massive modifications to the existing infrastructure. Recent instances of physical attacks on LPTs and the slow recovery process associated with fixing or replacing these damaged units has created an increased awareness for this issue. LPT designs are highly customized owing to specific field requirements. Long lead times coupled with transportation delays make procuring and installing LPTs a lengthy process. In an attempt to minimize the recovery time following an LPT failure, transformer manufacturers have developed mobile transformer units. These units typically consist of either a single-phase or three-phase transformer mounted on a truck and characterized by compact form factors. By reducing the assembly time and transport time these units offer a fast and temporary solution to LPT failures. Several efforts led by DOE, Edison Electric Company (EEI) and North American Electric Reliability Corporation (NERC) have led to the RecX program. RecX transformers consist of single phase transformers transported on specialized assemblies to enable fast restoration and minimal installation time. NERC and EEI have instituted transformer sharing programs like Spare Equipment Database (SED) as well as Spare Transformer Equipment Database (STEP) which encourage utilities to maintain and share a fleet of LPTs. Mobile transformers are typically limited to less than 100 MVA to enable transportation on a trailer. Also, the efficiency of mobile transformer units and RecX transformers is lower since they are temporary solutions. The ideal replacement solution would be one that could utilize a set of standardized transformers while incorporating flexibility to influence metrics like power flow, apparent impedance and voltage profiles. In view of these issues the team at Georgia Tech proposed a concept called Modular Controllable Transformers (MCTs). This project was commissioned as a part of DOE’s Transformer Resiliency and Advance Component (TRAC) program. The approach consists of splitting one large unit rated upwards of 100 MVA with smaller modular, standardized units. Each of these smaller units are augmented with a converter to add power flow, voltage and impedance control. Splitting the power level into multiple units has two important implications. By making smaller units, the transportation times can be reduced drastically. Moreover, even though these units have very specific impedance and other parameters, the augmented converters can make it emulate the unit being replaced. Thus, faster replacement times and added controls are achieved making this an extremely resilient approach. In the event of one modular units failure, the other two controllable units can operate in the most resilient fashion keeping the net system overloads to a minimum. Moreover, for the same probability of failure only a fraction of the system capacity is lost. The converter is augmented on to the tertiary winding of the transformer making it retrofittable in the field without massive modifications to the system. The material proposed in this report highlights design considerations to minimize recovery time as well as results displaying overall improvement in resiliency. The cost analysis of this approach shows significant savings compared to UPFC and HVDC lite based approaches. Extensive analysis was conducted on numerous aspects of this project over the course of this project. Simulation studies were conducted to prove the 5MVA converter design. Challenging BIL constraints and transient issues were addressed over the course of this project. Simulations on EMTP platform presented in consequent sections were used to finely tune the control for the same. A final design for a back-to-back 5MVA neutral-point-clamped (NPC) converter was completed in this project. Furthermore, switching components like high power IGBTs from IXYS Westcode Press-Pack series and ABB Stackpack series were identified for this application. These devices exhibit a blocking voltage of 6.5 kV and a nominal collector current of 900 A. Potential housing options as well as existing commercial option were identified for this converter design. A 56 MVA modular transformer unit was designed with Delta Star Inc. with consultation and inputs from all project members. The transformer cooling systems were chosen to be Oil Natural Air Forced (ONAF) to optimize ease of transport. A full Product Requirement Document (PRD) for the converter and the transformer was generated. The team also investigated key aspects of resiliency and how to quantify the same. A metric was developed to analyze resiliency and numerous simulation cases were presented. Increased (N-1) resiliency and outage resistance was showcased through simulation on the Texas Large scale power system. Dynamic control capabilities were also showcased on numerous system level simulations. An IEEE 30 bus system was used to show the ability of the MCT approach to reduce line congestion. Power flow control; a part of the MCTs abilities, showcased a 29% reduction in transformer loading on the same system. Full control over tie line flows was demonstrated on a modified IEEE 13 bus system. Dynamic LTC capabilities were shown through simulation and were compared to traditional LTCs. Furthermore, the ability of the MCTs to alter apparent transformer impedance was simulated to promote standardization of modular transformer units while retaining the ability to emulate a varied range of impedance characteristics. Thus granular control over power flow, voltages, impedances and was presented. Regulatory analysis conducted by Oak Ridge National Laboratory (ORNL) further bolstered the efficacy of the MCT approach and verified the added resiliency achieved due to this approach. As a conclusion, it was proved that the resilience improvement obtained from using the MCT approach is justified by just one failure in a 30-year period. This means that the benefits obtained from using the MCT approach far outweigh the cost of setting this approach up. As a part of the future efforts, the team is proposing building a (12.47-24) kV/400 kVA scaled down unit to control 5MVA of power flows. Emphasis would be laid on using commercial components to speed up the build of these units. Further the actual transport of the modular transformer unit would be a part of this operation and would provide insight into transportation issues. The approach shows much promise and adds key dynamic control on passive sub transmission and transmission sectors.

24 POWER TRANSMISSION AND DISTRIBUTION↗

The NSLS-II Control Network Design

The required positioning tolerances are an essential part of the survey and alignment design. The following tables show the requirement of storage ring. Table 1 provides the required global tolerances, while Table 2 outlines the relative tolerances for the NSLS-II girder-to-girder positioning. These tolerances dictate the instruments and methods necessary to obtain the positioning goals. The global tolerance is a little bit relaxed, but the ± 0.10 mm positioning requirement of adjacent girders is rather strict if the larger dimension and probable foundation settlement is considered. control network. Therefore, whether the goals can be obtained is mainly dependent on the performance of control network. The shape of control network defines the global alignment accuracy, while the relative position relationships of monuments determine the relative positioning accuracy between girders. When deciding the strategy of survey and alignment techniques, the instrumentation and approach of light sources have been built and are still in construction are investigated. State-of-the art equipment and methods will be employed. NSLS-II covers an area of about one-eighth of a square kilometer with a radius of ~126 m and a circumference of ~792 m. Depending on the size of the system to be constructed, primary and secondary control networks are required to achieve these tolerances. Primary control network will provide global control for different tunnels, and it should possess a relative point accuracy of better than ± 3 mm for all the storage ring monuments. Secondary control network will direct the alignment of girders in tunnel with the ability to ensure the final ± 0.10 mm positioning accuracy. The experiences from accomplished light source indicate that: for a dimension like NSLS2, primary control network can obtain a point accuracy of better than ± 1 mm easily, while secondary control network can obtain a relative point accuracy of ± 0.08 mm. With this expectation, the tolerance can be achieved for both the global and relative situation. Take the relative positioning requirement as an example, with 2 control network error of ± 0.08 mm, instrument tie-in error of ± 0.04 mm, and residual error of ± 0.04 mm, according to error propagation formula, the final alignment error should be better than ± 0.1 mm. Correspondingly, if a better control network accuracy can be achieved, the requirement for the residuals can be looser. The further alignment accuracy improvement will be realized by a smoothing process to assure the better position relationship between adjacent girders. The following simulation will perform error analysis to evaluate the estimated accuracy of NSLS II control network.

36 MATERIALS SCIENCE↗

Design of a Linear-Quadratic-Gaussian Controller for a Single-Cavity Rigid-Bunch RF-System

Linear quadratic Gaussian (LQG) controllers have the potential to reduce rf-system noise in synchrotron storage rings below what is ordinarily achieved with conventional proportional-integral (PI) controllers. But realizing this possibility requires careful design of the controller to match the characteristics of the machine (which is simplified by top-off operation) and is computationally demanding. This study develops computational methods for the construction of LQG controllers for discrete-time models of single-cavity rf systems coupled to rigid-bunch beams, and driven by rf amplifier noise. Matlab’s control-systems toolbox (CST) is the primary computational tool, particularly for the steady-state Kalman estimator, the LQR feedback, and the LQG controller. Of the rf signals available to the controller, a subset is chosen that results in a stable, effective, and economical controller. This floating-point LQG controller is then analyzed to establish resolutions of state variables, ADCs, DACs, and matrix coefficients that, in a fixed-point controller, provided essentially undiminished performance. A Simulink model computes beam noise in linear and nonlinear rf-system models with floating-point, fixed-point, and proportional-integral controllers. This machinery is applied to NSLS-II, CLS, and NSLS VUV rings showing bandwidth and amplifier noise suppression beyond what a PI controller can do. Required signal resolutions are surprisingly moderate. Testing and tuning with response functions computed by Vlasov simulations are performed. Thoughts are given on the further validation and tuning of the linearized model by machine measurements, DSP implementations, and future work.

36 MATERIALS SCIENCE↗

Supervisory Control System for Multi-Modular Advanced Reactors

The proposed supervisory control system (SCS) may provide considerable benefits to advanced small modular reactors, including reduced plant staffing, optimized maintenance activities, greater plant availability, and higher operating efficiency. The SCS makes risk-informed decisions based on (1) a probabilistic assessment of the likelihood of success given the status of the plant/systems and component health, and (2) a deterministic assessment between plant operating parameters and reactor protection parameters to prevent unnecessary trips and challenges to plant safety system—one measure of SCS success. The probabilistic portion of the decision-making engine of the SCS is based on the control actions associated with an advanced liquid-metal reactor (ALMR) Power Reactor, Innovative, Small Module (PRISM). Within the SCS, the probabilistic assessment provides a ranking of viable control actions; however, certain instructions generated by the probabilistic model only include an abstract notion of action without specifications. For instance, one instruction may be to reduce power without specifying how much reduction is needed. The prognostic/diagnostic models incorporate the health of components into the decision-making process. Once the control options are identified and ranked based on the likelihood of success, the SCS transmits the options to the deterministic portion of the platform. The performance-based system models assess and rank each of the probabilistically identified control actions by taking into account the physical behavior (current and projected) of the system. The performance-based decision making module receives inputs from the probabilistic decision-making module and the ERM module to generate a single solution. Interfaces to these modules are defined later in the section. A utility theory algorithm factors into the decision making by estimating the distance from and approach to a trip setpoint for each control option. If the magnitude of a negative utility value increases rapidly as the system approaches the trip setpoint, that option is not likely to be the preferred option. This can lead to a re-ranking of the control options. The SCS then transmits a control signal(s) to a component or system and informs the operator of actions taken based on the action chosen. The SCS successfully coupled probabilistic and performance-based system models to arrive at optimal control decisions based on the actual status of the plant and components. The automatic, autonomous, and real-time performance requirements for a control system were met by the SCS. The value of coupling probabilistic and performance-based system models was demonstrated by the re-ranking of control options based on the use of a utility algorithm. The use of ERM monitors provides added value to the SCS as demonstrated by the re-ranking of control options based on a components degraded state.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Hierarchical Model-Free Transactive Control of Building Loads to Support Grid Services

Residential buildings consume 4.4 quads of electricity annually, approximately 37% of the total electricity consumption in the United States. This represents a vast resource that can be used for demand management and other ancillary services. This project aims to develop a robust, scalable hierarchical transactional control mechanism incorporating elements of model-free control (MFC) and game theory to harness buildings to provide ancillary services to the grid. This approach is being taken to address the challenges of incorporating traditional transactional control schemes into existing buildings. The challenges include small individual building sizes requiring aggregation of many buildings, unpredictable energy usage that makes model identification difficult, and satisfying the sensitive occupant comfort constraints. In the proposed approach, by separating the control mechanism into two layers above and below the load aggregator, MFC can be used below the aggregator to modulate flexible building loads in response to pricing signals with guaranteed performance. This allows the burden of identifying an accurate model of the system to be shifted to the above-aggregator layer, where fluctuations in individual building usage have less impact on predicted building system behavior. Game theory concepts can then be used to determine pricing curves and control signals among regional aggregators. Managing this control in a game-theoretic approach will allow us to build in financial incentives that increase customer engagement. Additionally, the usage of MFC necessitates less burdensome computational and communication requirements, thus, it is easily deployable on small, embedded devices. In a broader sense, developing a strategy capable of effectively incorporating residential and small commercial buildings will allow greater throughput of existing and emerging grid services in addition to future transactive energy grid management methods. Using MFC within a hierarchical control architecture will allow the shifting of existing forecasting challenges to an aggregate level, where dynamics are slower and more predictable. This will enable a smooth interface between the grid services requests of utilities and the reliable control required by participating buildings. MFC, which supports distributed control architecture, permits a scalable solution that can be deployed to neighborhood-size systems as well as individual buildings. This project focuses on three objectives: (1) developing the mathematical framework, algorithm toolkit, and software toolset of the two-layer transactive control testbed; (2) developing a scalable solution for application over many residential and small-size commercial buildings with sparse distributed communication; and (3) field testing and implementation on hardware of the control strategies developed in the previous two objectives. The research and development activities are focused and designed to be impactful within the relevant 2025 targets timeframe. An open-source control framework for exploiting variability and dispatchability of building loads will be delivered as the outcome of the project. This capability enables greater participation of loads in electricity markets and ancillary services that are both useful for the utility and financially beneficial for building owners.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Improved Moisture Management Technology for Eco-N-Control Fertilizer

Three fertilizer technologies to manage nitrogen (N) release rates in soil dominate the market today: 1) bulk controlled-release technologies, which use the intrinsic solubility properties of a N-organic co-polymer to control N release; 2) barrier-based controlled-release technologies, which use porous polymer or sulfur coatings as a physical barrier to control N release from encapsulated N nutrients; and 3) slow-release technologies, which use enzyme inhibitors to chemically slow down the transformation of N nutrients into ammonia (NH 3 ) or to temporarily reduce populations of bacteria in the soil that are responsible for converting ammonium (NH 4 + ) to highly soluble nitrates. These technologies are expensive and provide only limited control of N-release rates. Also, from another environmental perspective, synthetic polymer coatings do not decompose easily and will accumulate over time with continuous application of fertilizer. For most of the past two decades we have been developing the Eco-N-Control solid-nitride fertilizer technology, a type of bulk controlled-release technology. With Eco-N-Control, solid-nitride compounds weather like a mineral, slowly releasing N at a rate determined by their composition. Testing by an industrial collaborator, however, showed that earlier versions of Eco-N-Control released at 25% of the desired rate when deployed in unsaturated soils. The overall goal of the current project, therefore, was to strengthen our IP position and the potential for licensing of Eco-N-Control solid-nitride fertilizer technology by developing new ways to manage the level of moisture in contact with the fertilizer when applied to soil thereby ensuring the desired N-release rate. We achieved this goal by developing a biodegradable polymer cross-linking approach that substantially improved performance of our patented solid-nitride fertilizer. We found that cross-linking an environmentally friendly and biodegradable polymer with a mixture of solid nitrides, other N-nutrient compounds and other additives offers several advantages: 1) mechanical robustness of fertilizer beads, 2) chemical stability during storage, 3) maintenance of sufficient water content in the vicinity of the nitride, and 4) control of N-release rates. We also updated our N-release testing protocol to more realistically simulate the conditions found in soil. Finally, we filed an invention disclosure record to protect these new aspects of Eco-N-Control technology, which offers a potential way to lower both agricultural and industrial pollution by providing an efficient N-delivery mechanism to plants.

42 ENGINEERING↗

Demonstrating Load-Shaping Capabilities of Cost Minimizing Heat Pump Water Heater Controls with Varying Price Profiles

Increased penetration of photovoltaics and electrification of traditionally gas appliances are exacerbating existing challenges in cost-effectively balancing electricity grid supply and demand. Decarbonization without incurring expensive transmission and distribution system capacity increases requires shifting building loads from peak demand times to peak renewable production times. Grid operators are evaluating new ways of encouraging load shifting, including using time-varying price structures to provide a financial incentive. If devices incorporate price-responsive controls, a price profile could be designed to yield a wide variety of load curves as needed to optimize grid functionality. Heat pump water heaters (HPWHs) are an ideal device for price-responsive controls because the storage tank enables them to optimize the timing of electricity consumption without impacting hot water delivery service. This paper presents work demonstrating how price-responsive controls for HPWHs can provide different load profiles, as needed to stabilize the grid, in response to different price profiles. HPWH manufacturers now include web API and CTA-2045 communication capabilities which enable sending load shaping control signals. Pilot studies and preliminary programs have utilized these capabilities with uniform control strategies to reduce 4-9 PM electricity consumption. However, no studies have developed flexible controls capable of both a) responding to constantly varying price profiles and b) customizing logic to match the needs of each HPWH. Berkeley Lab's CalFlexHub project is pioneering price-driven load flexibility by developing and deploying cost-minimizing controls utilizing setpoint setting signals for fleets of HPWHs in response to varying price profiles. Control development is based on simulations using the Flexible Heat Pump Water Heater Performance Predictor which captures the control decisions of a residential, integrated HPWH manufacturer’s on-board controller. The proposed cost-reducing controls respond to constantly changing price profiles, providing the ability to change the price profile to generate load curves as needed to maintain grid stability. Preliminary simulations studying the load shaping capabilities of price-responsive controls on a fleet of 60 HPWHs have demonstrated an average of a) 135.4% increases in load during low-price periods, b) >36.8% reductions in electricity peak-price period, and c) 6.2% electricity cost savings.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Adaptive Control of a Utility-Scale Wind Turbine Operating in Region 3

Many challenges exist for the efficient and safe operation of wind turbines due to the difficulty in creating accurate models of their dynamic characteristics and the turbulent conditions in which they operate. A promising new area of wind turbine research is the application of adaptive control techniques, which are well suited to problems where the plant model is not well known and the plant operating conditions are unpredictable. In this paper, we design an adaptive collective pitch controller for a high-fidelity simulation of a utility scale, variable-speed horizontal axis wind turbine operating in Region 3. The objective of the adaptive pitch controller is to regulate generator speed and reject step disturbances, which model the uniform wind disturbance across the wind turbine rotor. The control objective is accomplished by collectively pitching the turbine blades. To improve controller performance, we use an extension of the Direct Model Reference Adaptive Control (DMRAC) approach to regulate turbine rotational speed and to accommodate step disturbances. The turbine simulation models the Controls Advanced Research Turbine (CART) of the National Renewable Energy Laboratory in Golden, Colorado. The CART is a utility-scale wind turbine that has a well-developed and extensively verified simulator. The adaptive collective pitch controller for Region 3 was compared in simulations with a baseline classical Proportional Integrator (PI) collective pitch controller. In the simulations, the adaptive pitch controller showed improved generator speed regulation in Region 3 when compared with the baseline PI pitch controller. The adaptive controller demonstrated robustness to modeling errors and changes in system parameters.

17 WIND ENERGY↗

Optimal control system design for IGCC power plants with CO2 capture

Designing an optimal control system for an integrated gasification combined cycle (IGCC) power plant with CO2 capture addresses the challenge of efficiently operating and controlling a coal-fed IGCC plant with the desired extent of CO2 capture in the face of disturbances without violating operational and environmental constraints. The control system design needs to optimize a desired scalar objective function while satisfying all the operational and environmental constraints in the presence of measured and unmeasured disturbances. Various objective functions can be considered for the control system design such as maximization of profit, maximization of the power produced, or minimization of the auxiliary power. The design of such a control system makes the plant suitable to play an active role in the smart grid era as the plant will have the required agility. In addition, other penalty function(s) such as emission penalties for CO2 or other criteria pollutants can be considered in the framework as well as losses associated with any hydrogen or carbon monoxide loses. The proposed control system design is performed in two stages. In the first stage, a top-down analysis is performed to generate a list of controlled, manipulated, and disturbance variables considering a scalar operational objective and other process constraints. In the second stage, a bottom-up approach for simultaneous design of the control structure and the controllers is used. In this paper, the first stage of the two-stage approach is applied to the IGCC’s acid gas removal (AGR) process which removes both H2S and CO2 from the shifted synthesis gas. While these results are still preliminary, they demonstrate the application of the proposed approach for a commercial-scale plant and show some interesting results related to controlled variable selection. Such an approach can be followed not only to design control systems for new power plants, but also to retrofit control systems for existing plants with suitable modifications.

97 MATHEMATICS AND COMPUTING↗

Flexible Reinforcement Learning Framework for Building Control using EnergyPlus-Modelica Energy Models

In recent years, reinforcement learning (RL) methods have been greatly enhanced by leveraging deep learning approaches. RL methods applied to building control have shown potential in many applications due to their ability to complement or replace conventional methods such as model-based or rule-based controls. However, RL-based building control software is likely tailored either to one target building system or to a specific RL method so that significant additional effort would be required to customize the RL-based controller for use in other building systems or with other RL approaches. Also, RL-based building controls usually depend on building energy simulations to train controllers, so emulating building dynamics (i.e., thermal dynamics and control dynamics) and capturing sub-hourly dynamic profiles are crucial to further the development of effective RL-based building control methods. To address these challenges, we present an open source RL-based control software employing a high-fidelity hybrid EnergyPlus-Modelica building energy model which emulates building dynamics at 1-minute resolution. This software consists of decoupled components (environment, building emulator, control agent, and RL algorithm), which allows for quick prototyping and benchmarking of standard RL algorithms in different systems; for example, a single component can be replaced without revising all of the software. To demonstrate this software framework, we conducted a benchmark study using an EnergyPlus-Modelica building energy model for a Chicago office building with an RL-based controller to dynamically control the chilled water temperature setpoint and the air handling unit supply air temperature setpoint on selected floors.

Lee, Joon-Yong↗

Model predictive current profile control in tokamaks by exploiting spatially moving electron cyclotron current drives

The plasma control systems in next-generation tokamaks like ITER will balance competing control objectives to achieve the desired level of performance in advanced scenarios while preventing magnetohydrodynamic instabilities and disruptions. During normal tokamak operation, the points of incidence of the electromagnetic waves generated by the electron cyclotron heating and current drives (EC H&CDs) are usually fixed in space. However, the points of incidence can be modified in real-time by changing the angles of the mirrors that reflect the EC H&CD waves. Altering the points of incidence, in turn, varies the ability of the plasma control system to regulate a plasma property. For instance, changing the EC H&CD wave incidence location may place the power demands necessary to achieve a particular plasma target within saturation limits. Therefore, using the EC H&CD deposition location, which is related to the EC H&CD mirror angle, as a supplementary controllable variable may facilitate access to a given target scenario. However, active scenario-control algorithms have not been designed so far to fully exploit this capability in real time. In this work, a model predictive controller that can handle actuation locations as control inputs is developed. In particular, the controller is designed to regulate both the auxiliary powers and the EC H&CD deposition locations in a pre-defined optimal sense to achieve the control objective of attaining and sustaining a target current profile. Further, the proposed controller is tested for a DIII-D tokamak scenario in nonlinear simulations using the Control Oriented Transport SIMulator (COTSIM).

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Real-time plasma control in a dual-frequency, confined plasma etcher

The physics issues of developing model-based control of plasma etching are presented. A novel methodology for incorporating real-time model-based control of plasma processing systems is developed. The methodology is developed for control of two dependent variables (ion flux and chemical densities) by two independent controls (27 MHz power and O{sub 2} flow). A phenomenological physics model of the nonlinear coupling between the independent controls and the dependent variables of the plasma is presented. By using a design of experiment, the functional dependencies of the response surface are determined. In conjunction with the physical model, the dependencies are used to deconvolve the sensor signals onto the control inputs, allowing compensation of the interaction between control paths. The compensated sensor signals and compensated set-points are then used as inputs to proportional-integral-derivative controllers to adjust radio frequency power and oxygen flow to yield the desired ion flux and chemical density. To illustrate the methodology, model-based real-time control is realized in a commercial semiconductor dielectric etch chamber. The two radio frequency symmetric diode operates with typical commercial fluorocarbon feed-gas mixtures (Ar/O{sub 2}/C{sub 4}F{sub 8}). Key parameters for dielectric etching are known to include ion flux to the surface and surface flux of oxygen containing species. Control is demonstrated using diagnostics of electrode-surface ion current, and chemical densities of O, O{sub 2}, and CO measured by optical emission spectrometry and/or mass spectrometry. Using our model-based real-time control, the set-point tracking accuracy to changes in chemical species density and ion flux is enhanced.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Model predictive control of KSTAR equilibrium parameters enabled by TRANSP

Due to the complex behavior of tokamak plasmas and the importance of optimizing performance while avoiding instabilities and machine limits, plasma control algorithms are becoming increasingly dependent on sophisticated model-based control approaches. It is anticipated that the use of integrated modeling codes in the model-based control design process will reduce the amount of experimental time needed to implement new control algorithms by facilitating development of control-oriented models and enabling higher-fidelity closed-loop simulations. In this work, a reduced model is developed from a series of TRANSP simulations and is used to develop a model predictive control (MPC) algorithm for controlling important equilibrium parameters in KSTAR [1] discharges. The control algorithm uses the KSTAR neutral beam injection system and the target plasma current and plasma boundary as actuators, and optimizes the plasma stored energy, loop voltage, and internal inductance while avoiding constraints that could lead to disruptions. Higher fidelity testing of the control algorithm is performed using a flexible framework for enabling external processes to actively control plasma parameters in TRANSP simulations. Furthermore, closed-loop simulations demonstrate the ability of the control algorithm to respond to disturbances in density and confinement, handle actuator failures, and move the discharge to high non-inductive fraction conditions.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Role of controllability in optimizing quantum dynamics

This paper reveals an important role that controllability plays in the complexity of optimizing quantum control dynamics. We show that the loss of controllability generally leads to multiple locally suboptimal controls when gate fidelity in a quantum control system is maximized, which does not happen if the system is controllable. Such local suboptimal controls may attract an optimization algorithm into a local trap when a global optimal solution is sought, even if the target gate can be perfectly realized. This conclusion results from an analysis of the critical topology of the corresponding quantum control landscape, which refers to the gate fidelity objective as a functional of the control fields. For uncontrollable systems, due to SU(2) and SU(3) dynamical symmetries, the control landscape corresponding to an implementable target gate is proven to possess multiple locally optimal critical points, and its ruggedness can be further increased if the target gate is not realizable. These results imply that the optimization of quantum dynamics can be seriously impeded when operating with local search algorithms under these conditions, and thus full controllability is demanded.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Scaling the robustness of the solutions for quantum controllable problems

The major task in quantum control theory is to find an external field that transforms the system from one state to another or executes a predetermined unitary transformation. We investigate the difficulty of computing the control field as the size of the Hilbert space is increased. In the models studied the controls form a small closed subalgebra of operators. Complete controllability is obtained by the commutators of the controls with the stationary Hamiltonian. We investigate the scaling of the computation effort required to converge a solution for the quantum control task with respect to the size of the Hilbert space. The models studied include the double-well Bose Hubbard model with the SU(2) control subalgebra and the Morse oscillator with the Heisenberg-Weil algebra. We find that for initial and target states that are classified as generalized coherent states (GCSs) of the control subalgebra the control field is easily found independent of the size of the Hilbert space. For such problems, a control field generated for a small system can serve as a pilot for finding the field for larger systems. Attempting to employ pilot fields that generate superpositions of GCSs or cat states failed. No relation was found between control solutions of different Hilbert space sizes. In addition the task of finding such a field scales unfavorably with Hilbert space sizes. We demonstrate the use of symmetry to obtain quantum transitions between states without phase information. Implications to quantum computing are discussed.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

MPC-Based Local Voltage Control Strategy of DGs in Active Distribution Networks

The increasing penetration of distributed generators (DGs) exacerbates the voltage violations in active distribution networks (ADNs). The commonly used centralized voltage control may aggravate the burden of computation and communication. Local voltage control can realize fast response to frequent voltage fluctuations. However, effective local control for DGs still needs to be further investigated. In this paper, a model predictive control (MPC)-based local voltage control strategy of DGs is proposed to cope with voltage violation problems and enhance the adaptation to the DG volatility. DGs are regulated with local Q-V control curves to respond to voltage fluctuations rapidly. Based on the dynamic network partition, a unified control curve for DGs is set in the same area to realize efficient operation. To further improve the performance of voltage control, the parameter tuning of control curves is regularly conducted based on decentralized inter-area coordination with the rolling of the control horizon. Finally, case study is verified on the modified IEEE 33-node distribution system. The proposed local control strategy of DGs can effectively improve the voltage profile and reduce power losses of the whole network without high computation and communication burden.

active distribution network (ADN)↗