Search NASA⌕ Search

SEARCH · Search NASA

Results for “Diffraction pattern”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,423 records · Page 79

Femtosecond X-ray Fourier holography imaging of free-flying nanoparticles

Ultrafast X-ray imaging on individual fragile specimens such as aerosols, metastable particles, superfluid quantum systems and live biospecimens provides high-resolution information that is inaccessible with conventional imaging techniques. Coherent X-ray diffractive imaging, however, suffers from intrinsic loss of phase, and therefore structure recovery is often complicated and not always uniquely defined. Here in this paper, we introduce the method of in-flight holography, where we use nanoclusters as reference X-ray scatterers to encode relative phase information into diffraction patterns of a virus. The resulting hologram contains an unambiguous three-dimensional map of a virus and two nanoclusters with the highest lateral resolution so far achieved via single shot X-ray holography. Our approach unlocks the benefits of holography for ultrafast X-ray imaging of nanoscale, non-periodic systems and paves the way to direct observation of complex electron dynamics down to the attosecond timescale.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

In situ TEM observation of alpha-particle induced annealing of radiation damage in Durango apatite

A major issue in thermochronology and U-Th-Pb dating is the effect of radiation damage, created by α-recoils from α-decay events, on the diffusion of radiogenic elements (e.g., He and Pb) in host mineral. Up until now, thermal events have been considered as the only source of energy for the recovery of radiation-damage. However, irradiation, such as from the α-particle of the α-decay event, can itself induce damage recovery. Quantification of radiation-induced recovery caused by α-particles during α-decay events has not been possible, as the recovery process at the atomic-scale has been difficult to observe. Here we present details of the dynamics of the amorphous-to-crystalline transition process during α-particle irradiations using in situ transmission electron microscopy (TEM) and consecutive ion-irradiations: 1 MeV Kr 2+ (simulating α-recoil damage), followed by 400 keV He+ (simulating α-particle annealing). Upon the He + irradiation, partial recrystallization of the original, fully-amorphous Durango apatite was clearly evident and quantified based on the gradual appearance of new crystalline domains in TEM images and new diffraction maxima in selected area electron diffraction patterns. Thus, α-particle induced annealing occurs and must be considered in models of α-decay event damage and its effect on the diffusion of radiogenic elements in geochronology and thermochronology.

58 GEOSCIENCES↗

Real-time coherent diffraction inversion using deep generative networks

Abstract Phase retrieval, or the process of recovering phase information in reciprocal space to reconstruct images from measured intensity alone, is the underlying basis to a variety of imaging applications including coherent diffraction imaging (CDI). Typical phase retrieval algorithms are iterative in nature, and hence, are time-consuming and computationally expensive, making real-time imaging a challenge. Furthermore, iterative phase retrieval algorithms struggle to converge to the correct solution especially in the presence of strong phase structures. In this work, we demonstrate the training and testing of CDI NN, a pair of deep deconvolutional networks trained to predict structure and phase in real space of a 2D object from its corresponding far-field diffraction intensities alone. Once trained, CDI NN can invert a diffraction pattern to an image within a few milliseconds of compute time on a standard desktop machine, opening the door to real-time imaging.

97 MATHEMATICS AND COMPUTING↗

Impact and mitigation of angular uncertainties in Bragg coherent x-ray diffraction imaging

Bragg coherent diffraction imaging (BCDI) is a powerful technique to explore the local strain state and morphology of microscale crystals. The method can potentially reach nanometer-scale spatial resolution thanks to the advances in synchrotron design that dramatically increase coherent flux. However, there are experimental bottlenecks that may limit the image reconstruction quality from future high signal-to-noise ratio measurements. In this work we show that angular uncertainty of the sample orientation with respect to a fixed incoming beam is one example of such a factor, and we present a method to mitigate the resulting artifacts. On the basis of an alternative formulation of the forward problem, we design a phase retrieval algorithm which enables the simultaneous reconstruction of the object and determination of the exact angular position corresponding to each diffraction pattern in the data set. We have tested the algorithm performance on simulated data for different degrees of angular uncertainty and signal-to-noise ratio.

36 MATERIALS SCIENCE↗

Multi-beam X-ray ptychography for high-throughput coherent diffraction imaging

X-ray ptychography is a rapidly developing coherent diffraction imaging technique that provides nanoscale resolution on extended field-of-view. However, the requirement of coherence and the scanning mechanism limit the throughput of ptychographic imaging. Herein, we propose X-ray ptychography using multiple illuminations instead of single illumination in conventional ptychography. Multiple locations of the sample are simultaneously imaged by spatially separated X-ray beams, therefore, the obtained field-of-view in one scan can be enlarged by a factor equal to the number of illuminations. We have demonstrated this technique experimentally using two X-ray beams focused by a house-made Fresnel zone plate array. Two areas of the object and corresponding double illuminations were successfully reconstructed from diffraction patterns acquired in one scan, with image quality similar with those obtained by conventional single-beam ptychography in sequence. Multi-beam ptychography approach increases the imaging speed, providing an efficient way for high-resolution imaging of large extended specimens.

47 OTHER INSTRUMENTATION↗

Toward fully automated UED operation using two-stage machine learning model

To demonstrate the feasibility of automating UED operation and diagnosing the machine performance in real time, a two-stage machine learning (ML) model based on self-consistent start-to-end simulations has been implemented. This model will not only provide the machine parameters with adequate precision, toward the full automation of the UED instrument, but also make real-time electron beam information available as single-shot nondestructive diagnostics. Furthermore, based on a deep understanding of the root connection between the electron beam properties and the features of Bragg-diffraction patterns, we have applied the hidden symmetry as model constraints, successfully improving the accuracy of energy spread prediction by a factor of five and making the beam divergence prediction two times faster. The capability enabled by the global optimization via ML provides us with better opportunities for discoveries using near-parallel, bright, and ultrafast electron beams for single-shot imaging. It also enables directly visualizing the dynamics of defects and nanostructured materials, which is impossible using present electron-beam technologies.

36 MATERIALS SCIENCE↗

Helium-electrospray improves sample delivery in X-ray single-particle imaging experiments

Abstract Imaging the structure and observing the dynamics of isolated proteins using single-particle X-ray diffractive imaging (SPI) is one of the potential applications of X-ray free-electron lasers (XFELs). Currently, SPI experiments on isolated proteins are limited by three factors: low signal strength, limited data and high background from gas scattering. The last two factors are largely due to the shortcomings of the aerosol sample delivery methods in use. Here we present our modified electrospray ionization (ESI) source, which we dubbed helium-ESI (He-ESI). With it, we increased particle delivery into the interaction region by a factor of 10, for 26 nm-sized biological particles, and decreased the gas load in the interaction chamber corresponding to an 80% reduction in gas scattering when compared to the original ESI. These improvements have the potential to significantly increase the quality and quantity of SPI diffraction patterns in future experiments using He-ESI, resulting in higher-resolution structures.

Science & Technology - Other Topics↗

Release dynamics of nanodiamonds created by laser-driven shock-compression of polyethylene terephthalate

Laser-driven dynamic compression experiments of plastic materials have found surprisingly fast formation of nanodiamonds (ND) via X-ray probing. This mechanism is relevant for planetary models, but could also open efficient synthesis routes for tailored NDs. We investigate the release mechanics of compressed NDs by molecular dynamics simulation of the isotropic expansion of finite size diamond from different P-T states. Analysing the structural integrity along different release paths via molecular dynamic simulations, we found substantial disintegration rates upon shock release, increasing with the on-Hugnoiot shock temperature. We also find that recrystallization can occur after the expansion and hence during the release, depending on subsequent cooling mechanisms. Our study suggests higher ND recovery rates from off-Hugoniot states, e.g., via double-shocks, due to faster cooling. Laser-driven shock compression experiments of polyethylene terephthalate (PET) samples with in situ X-ray probing at the simulated conditions found diamond signal that persists up to 11 ns after breakout. In the diffraction pattern, we observed peak shifts, which we attribute to thermal expansion of the NDs and thus a total release of pressure, which indicates the stability of the released NDs.

36 MATERIALS SCIENCE↗

Impact of gas background on XFEL single-particle imaging

Abstract Single-particle imaging (SPI) using X-ray free-electron Lasers (XFELs) offers the potential to determine protein structures at high spatial and temporal resolutions without the need for crystallization or vitrification. However, the technique faces challenges due to weak diffraction signals from single proteins and significant background scattering from gases used for sample delivery. A recent observation of a diffraction pattern from an isolated GroEL protein complex Ekeberg T et al. (Light Sci Appl 13:15, 2024.https://doi.org/10.1038/274s41377-023-01352-7) had similar numbers of signal and background photons. Ongoing efforts aim to reduce the background created by sample delivery, with one approach replacing most of the used gas with helium Yenupuri T et al. (Sci Rep 14:4401, 2024.https://doi.org/10.1038/s41598-024-54605-9). In this study, we investigate the effects of a reduced background on the resolution limits for SPI of isolated proteins under different experiment conditions. As a test case, we used GroEL, and we used experimentally derived parameters for our simulations. We observe that background significantly impacts the achievable resolution, particularly when the signal strength is comparable to the background. This is best exemplified at 6.0 keV, where a background reduction by a factor of 10 leads to a resolution improvement from 1.9 to 1.2 nm, for a dataset of$$10^4$$patterns.

Science & Technology - Other Topics↗

Megahertz single-particle imaging at the European XFEL

The emergence of high repetition-rate X-ray free-electron lasers (XFELs) powered by superconducting accelerator technology enables the measurement of significantly more experimental data per day than was previously possible. The European XFEL is expected to provide 27,000 pulses per second, over two orders of magnitude more than any other XFEL. The increased pulse rate is a key enabling factor for single-particle X-ray diffractive imaging, which relies on averaging the weak diffraction signal from single biological particles. Taking full advantage of this new capability requires that all experimental steps, from sample preparation and delivery to the acquisition of diffraction patterns, are compatible with the increased pulse repetition rate. Here, we show that single-particle imaging can be performed using X-ray pulses at megahertz repetition rates. The results obtained pave the way towards exploiting high repetition-rate X-ray free-electron lasers for single-particle imaging at their full repetition rate.

36 MATERIALS SCIENCE↗

The superconducting diode effect in Josephson junctions fabricated from a structurally chiral superconductor

The superconducting diode effect occurs in superconducting materials in which both time-reversal and inversion symmetry are broken. The recently observed chirality-induced spin selectivity effect demonstrates that chiral materials break both symmetries. Thus, a Josephson junction interface with the left-handed structure on one side of the junction and the right-handed structure on the other should exhibit a diode effect. Here, we report the electrical transport properties of right-handed/left-handed and right-handed/right-handed devices fabricated from single crystals of the structurally chiral superconductor Mo 3 Al 2 C. Fraunhofer-like magnetic diffraction patterns confirm the presence of the Josephson effect in all but one of our devices. A magnetic-field-induced superconducting diode effect is demonstrated in the right-handed/left-handed devices by a statistically significant difference in I c + and ∣ I c −∣, with a maximum asymmetry of 5%. The intrinsic superconducting diode effect is not observed in the right-handed/right-handed devices. We provide an explanation for the presence of the superconducting diode effect in the right-handed/left-handed devices.

superconducting devices↗

Challenges and opportunities in attosecond and XFEL science

In 2009, the world’s first hard X-FEL brought a ten-billion-fold gain in X-ray peak brightness. This fuelled the avidly pursued, but still elusive, dream of single-shot imaging of non-crystalline samples with near-atomic resolution. The overarching concept of ‘diffract-before-destroy’ imaging is that a powerful burst of ultrafast X-rays can produce a coherent diffraction pattern of a nanoscale object — before the object explodes due to Coulomb repulsion caused by a massively parallel ionization of the atoms in the sample. A collection of snapshots of identical objects in random orientations then provide information from which a 3D structure can be retrieved.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Detection of thin film phase transformations at high-pressure and high-temperature in a diamond anvil cell

Abstract Quantifying how grain size and/or deviatoric stress impact (Mg,Fe) 2 SiO 4 phase stability is critical for advancing our understanding of subduction processes and deep-focus earthquakes. Here, we demonstrate that well-resolved X-ray diffraction patterns can be obtained on nano-grained thin films within laser-heated diamond anvil cells (DACs) at hydrostatic pressures up to 24 GPa and temperatures up to 2300 K. Combined with well-established literature processes for tuning thin film grain size, biaxial stress, and substrate identity, these results suggest that DAC-loaded thin films can be useful for determining how grain size, deviatoric stress, and/or the coexistence of other phases influence high-pressure phase stability. As such, this novel DAC-loaded thin film approach may find use in a variety of earth science, planetary science, solid-state physics, and materials science applications.

Environmental Sciences & Ecology↗

Ptychography at all wavelengths

Ptychography is a computational imaging technique that operates across multiple wavelength regimes, from electron (picometres) to X-ray (~0.1 nm), extreme ultraviolet (~10 nm) and visible light (micrometres). By reconstructing both amplitude and phase from diffraction patterns, ptychography enables high-resolution, quantitative imaging without conventional limitations imposed by lens-based optics. Ptychography has enabled advances across a range of scales: achieving deep-sub-angstrom resolution with electron microscopy, becoming an indispensable tool at X-ray synchrotron facilities worldwide and overcoming the trade-offs between resolution and field-of-view in optical imaging. This Primer provides a unified treatment of ptychography across these wavelength regimes. First, we discuss theoretical foundations, reconstruction algorithms, experimental considerations and wavelength-specific challenges. We then give examples of raw and processed data from various configurations and wavelengths. Next, we highlight key applications of ptychography in life sciences, materials science and industry. We also discuss data standards, open-source software implementations and best practices for ensuring reproducibility across different wavelength regimes. Finally, we consider limitations and future opportunities for ptychography. Together with accompanying datasets and code implementations, this Primer aims to serve newcomers and experienced practitioners in the field, facilitating broader adoption of ptychography across different disciplines.

47 OTHER INSTRUMENTATION↗

Se-SAD serial femtosecond crystallography datasets from selenobiotinyl-streptavidin

We provide a detailed description of selenobiotinyl-streptavidin (Se-B SA) co-crystal datasets recorded using the Coherent X-ray Imaging (CXI) instrument at the Linac Coherent Light Source (LCLS) for selenium single-wavelength anomalous diffraction (Se-SAD) structure determination. Se-B SA was chosen as the model system for its high affinity between biotin and streptavidin where the sulfur atom in the biotin molecule (C 10 H 16 N 2 O 3 S) is substituted with selenium. The dataset was collected at three different transmissions (100, 50, and 10%) using a serial sample chamber setup which allows for two sample chambers, a front chamber and a back chamber, to operate simultaneously. Diffraction patterns from Se-B SA were recorded to a resolution of 1.9 Å. The dataset is publicly available through the Coherent X-ray Imaging Data Bank (CXIDB) and also on LCLS compute nodes as a resource for research and algorithm development.

36 MATERIALS SCIENCE↗

Flexible and High Performance Supercapacitors Based on NiCo2O4for Wide Temperature Range Applications

Binder free nanostructured NiCo 2 O 4 were grown using a facile hydrothermal technique. X-ray diffraction patterns confirmed the phase purity of NiCo 2 O 4 . The surface morphology and microstructure of the NiCo 2 O 4 analyzed by scanning electron microscopy (SEM) showed flower-like morphology composed of needle-like structures. The potential application of binder free NiCo 2 O 4 as an electrode for supercapacitor devices was investigated using electrochemical methods. The cyclic voltammograms of NiCo2O4 electrode using alkaline aqueous electrolytes showed the presence of redox peaks suggesting pseudocapacitance behavior. Quasi-solid state supercapacitor device fabricated by sandwiching two NiCo 2 O 4 electrodes and separating them by ion transporting layer. The performance of the device was tested using cyclic voltammetry, galvanostatic charge-discharge and electrochemical impedance spectroscopy. The device showed excellent flexibility and cyclic stability. The temperature dependent charge storage capacity was measured for their variable temperature applications. Specific capacitance of the device was enhanced by ~150% on raising the temperature from 20 to 60°C. Hence, the results suggest that NiCo 2 O 4 grown under these conditions could be a suitable material for high performance supercapacitor devices that can be operated at variable temperatures.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Formation of nanotwin networks during high-temperature crystallization of amorphous germanium

Germanium is an extremely important material used for numerous functional applications in many fields of nanotechnology. In this paper, we study the crystallization of amorphous Ge using atomistic simulations of critical nano-metric nuclei at high temperatures. We find that crystallization occurs by the recurrent transfer of atoms via a diffusive process from the amorphous phase into suitably-oriented crystalline layers. We accompany our simulations with a comprehensive thermodynamic and kinetic analysis of the growth process, which explains the energy balance and the interfacial growth velocities governing grain growth. For the <111> crystallographic orientation, we find a degenerate atomic rearrangement process, with two zero-energy modes corresponding to a perfect crystalline structure and the formation of a Σ3 twin boundary. Continued growth in this direction results in the development a twin network, in contrast with all other growth orientations, where the crystal grows defect-free. This particular mechanism of crystallization from amorphous phases is also observed during solid-phase epitaxial growth of <111> semiconductor crystals, where growth is restrained to one dimension. Lastly, we calculate the equivalent X-ray diffraction pattern of the obtained nanotwin networks, providing grounds for experimental validation.

36 MATERIALS SCIENCE↗