Search NASA⌕ Search

SEARCH · Search NASA

Results for “ELECTROMAGNETIC INSTRUMENT”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,423 records · Page 79

Forward Di-Hadron Correlations in d+Au Collisions in PHENIX

Suppression in nuclear modification factors have been observed in past measurements at RHIC at {radical}(s{sub NN}) = 200 GeV in deuteron-gold collisions. Gluon saturation has been proposed as one among many explanations for this effect. Due to the gluon densities at low Bjoerken-x in the Lorentz-contracted gold nuclei, saturation effects are expected to be enhanced in the forward direction of the deuteron. Two new electromagnetic calorimeters have been incorporated into the PHENIX experiment covering pseudo-rapidities of 3.1<{eta}<3.7(3.9). We have used these calorimeters to study forward di-hadron correlations, probing parton momentum fractions down to x{sub Bj}{approx_equal}10{sup -3} in the gold nuclei. This analysis is based on the 2008 d+Au data with an integrated luminosity of 80 nb{sup -1}.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Multiphoton signal in supersymmetry comprising nonpointing photon(s) at the LHC

We study a distinct supersymmetric signal of multiphotons in association with jets and missing transverse energy. At least one of these photons has the origin in displaced vertex, and thus it is delayed and nonpointing. We consider a supersymmetric scenario in which the gravitino is the lightest supersymmetric particle (LSP) (with a mass {approx}1 keV) and the lightest neutralino is the next-to-lightest supersymmetric particle (NLSP). The NLSP decays dominantly into a photon and a gravitino within the detector with a decay length ranging from c{tau}{sub {tilde {chi}}} {approx}50-100 cm. In addition, we assume that the second-lightest neutralino and the lightest neutralino are nearly degenerate and this leads to a prompt radiative decay of the next-to-lightest neutralino into a photon and a lightest neutralino with a large branching ratio. Such degenerate neutralinos can be realized in various representations of the SU(5), SO(10) and E(6) GUT group. The nonpointing photons can be reconstructed at the electromagnetic calorimeter of the ATLAS detector, which have been designed with good timing and directional resolution. We find that with a center-of-mass energy E{sub cm}=14 TeV at an integrated luminosity of 100 fb{sup -1} one may see evidence of hundreds of triphoton events at the LHC, in addition to several thousands diphoton events. We also predict the event rates even at the early phase of LHC run.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Targeted coherent search for gravitational waves from compact binary coalescences

We introduce a method for conducting a targeted, coherent search for compact binary coalescences. The search is tailored to be used as a follow-up to electromagnetic transients such as gamma-ray bursts. We derive the coherent search statistic for Gaussian detector noise and discuss the benefits of a coherent, multidetector search over coincidence methods. To mitigate the effects of nonstationary data, we introduce a number of signal consistency tests, including the null signal-to-noise ratio, amplitude consistency, and several {chi}{sup 2} tests. We demonstrate the search performance on Gaussian noise and on data from LIGO's fourth science run and verify that the signal consistency tests are capable of removing the majority of noise transients, giving the search an efficiency comparable to that achieved in Gaussian noise.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

On sampling fractions and electron shower shapes

We study the usage of various definitions of sampling fractions in understanding electron shower shapes in a sampling multilayer electromagnetic calorimeter. We show that the sampling fractions obtained by the conventional definition (I) of (average observed energy in layer)/(average deposited energy in layer) will not give the best energy resolution for the calorimeter. The reason for this is shown to be the presence of layer by layer correlations in an electromagnetic shower. The best resolution is obtained by minimizing the deviation from the total input energy using a least squares algorithm. The 'sampling fractions' obtained by this method (II) are shown to give the best resolution for overall energy. We further show that the method (II) sampling fractions are obtained by summing the columns of a non-local {lambda} tensor that incorporates the correlations. We establish that the sampling fractions (II) cannot be used to predict the layer by layer energies and that one needs to employ the full {lambda} tensor for this purpose. This effect is again a result of the correlations.

43 PARTICLE ACCELERATORS↗

Detectors in Extreme Conditions

Free Electron Lasers opened a new window on imaging the motion of atoms and molecules. At SLAC, FEL experiments are performed at LCLS using 120Hz pulses with 10 12 - 10 13 photons in 10 femtoseconds (billions of times brighter than the most powerful synchrotrons). This extreme detection environment raises unique challenges, from obvious to surprising. Radiation damage is a constant threat due to accidental exposure to insufficiently attenuated beam, focused beam and formation of ice crystals reflecting the beam onto the detector. Often high power optical lasers are also used (e.g., 25TW), increasing the risk of damage or impeding data acquisition through electromagnetic pulses (EMP). The sample can contaminate the detector surface or even produce shrapnel damage. Some experiments require ultra high vacuum (UHV) with strict design, surface contamination and cooling requirements - also for detectors. The setup is often changed between or during experiments with short turnaround times, risking mechanical and ESD damage, requiring work planning, training of operators and sometimes continuous participation of the LCLS Detector Group in the experiments. The detectors used most often at LCLS are CSPAD cameras for hard x-rays and pnCCDs for soft x-rays.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Mitigated FPGA design of multi-gigabit transceivers for application in high radiation environments of High Energy Physics experiments

SRAM-ba8ed Field Programmable Gate Array (FPGA) logic devices arc very attractive in applications where high data throughput is needed, such as the latest generation of High Energy Physics (HEP) experiments. FPGAs have been rarely used in such experiments because of their sensitivity to radiation. The present paper proposes a mitigation approach applied to commercial FPGA devices to meet the reliability requirements for the front-end electronics of the Liquid Argon (LAr) electromagnetic calorimeter of the ATLAS experiment, located at CERN. Particular attention will be devoted to define a proper mitigation scheme of the multi-gigabit transceivers embedded in the FPGA, which is a critical part of the LAr data acquisition chain. A demonstrator board is being developed to validate the proposed methodology. :!\litigation techniques such as Triple Modular Redundancy (T:t\IR) and scrubbing will be used to increase the robustness of the design and to maximize the fault tolerance from Single-Event Upsets (SEUs).

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Quality Control of Pavements and Tarmacs Using ({sup 137}Cs){gamma} Compton Scattering

The {gamma} Compton scattering over a volume of concrete has been studied in order to design an instrument for density measurements. It will be used for the quality control in road construction, where large surfaces must be monitored. The experimental results and Monte Carlo simulations of the {gamma} Compton scattering over homogeneous and inhomogeneous volumes of concrete are shown. MC simulations have been useful to optimize the values of several parameters to improve the experimental set up and to estimate the extension of the explored volume.

42 ENGINEERING↗

Achieving Vibration Stability of the NSLS-II Hard X-ray Nanoprobe Beamline

The hard x-ray nanoprobe (HXN) beamline of the National Synchrotron Light Source II (NSLS-II) requires high levels of stability in order to achieve the desired instrument resolution. To ensure that the design of the endstation helps meet the stringent criteria and that natural and cultural vibration is mitigated both passively and actively, a comprehensive study complimentary to the design process has been undertaken. Vibration sources that have the potential to disrupt sensitive experiments such as wind, traffic, and NSLS II operating systems have been studied using state-of-the-art simulations and an array of field data. Further, final stage vibration isolation principles have been explored.

07 ISOTOPE AND RADIATION SOURCES↗

Alternative modeling methods for plasma-based Rf ion sources

Rf-driven ion sources for accelerators and many industrial applications benefit from detailed numerical modeling and simulation of plasma characteristics. For instance, modeling of the Spallation Neutron Source (SNS) internal antenna H{sup −} source has indicated that a large plasma velocity is induced near bends in the antenna where structural failures are often observed. This could lead to improved designs and ion source performance based on simulation and modeling. However, there are significant separations of time and spatial scales inherent to Rf-driven plasma ion sources, which makes it difficult to model ion sources with explicit, kinetic Particle-In-Cell (PIC) simulation codes. In particular, if both electron and ion motions are to be explicitly modeled, then the simulation time step must be very small, and total simulation times must be large enough to capture the evolution of the plasma ions, as well as extending over many Rf periods. Additional physics processes such as plasma chemistry and surface effects such as secondary electron emission increase the computational requirements in such a way that even fully parallel explicit PIC models cannot be used. One alternative method is to develop fluid-based codes coupled with electromagnetics in order to model ion sources. Time-domain fluid models can simulate plasma evolution, plasma chemistry, and surface physics models with reasonable computational resources by not explicitly resolving electron motions, which thereby leads to an increase in the time step. This is achieved by solving fluid motions coupled with electromagnetics using reduced-physics models, such as single-temperature magnetohydrodynamics (MHD), extended, gas dynamic, and Hall MHD, and two-fluid MHD models. We show recent results on modeling the internal antenna H{sup −} ion source for the SNS at Oak Ridge National Laboratory using the fluid plasma modeling code USim. We compare demonstrate plasma temperature equilibration in two-temperature MHD models for the SNS source and present simulation results demonstrating plasma evolution over many Rf periods for different plasma temperatures. We perform the calculations in parallel, on unstructured meshes, using finite-volume solvers in order to obtain results in reasonable time.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Tracing the redshift evolution of Hubble parameter with gravitational-wave standard sirens

Proposed space-based gravitational-wave detectors such as BBO and DECIGO can detect {approx}10{sup 6} neutron star (NS) binaries and determine the luminosity distance to the binaries with high precision. Combining the luminosity distance and electromagnetically derived redshift, one would be able to probe cosmological expansion out to high redshift. In this paper, we show that the Hubble parameter as a function of redshift can be directly measured with monopole and dipole components of the luminosity distance on the sky. As a result, the measurement accuracies of the Hubble parameter in each redshift bin up to z=1 are 3-14%, 1.5-8%, and 0.8-4% for the observation time 1 yr, 3 yr, and 10 yr, respectively.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Electromagnetic and Hadron Calorimeters in the MIPP Experiment

The purpose of the MIPP experiment is to study the inclusive production of photons, pions, kaons, and nucleons in π, K, and p interactions on various targets using beams from the Main Injector at Fermilab. The function of the calorimeters is to measure the production of forward-going neutrons and photons. The electromagnetic calorimeter consists of 10 lead plates interspersed with proportional chambers. It was followed by the hadron calorimeter with 64 steel plates interspersed with scintillator. The data presented were collected with a variety of targets and beam momenta from 5 GeV/c to 120 GeV/c. The energy calibration of both calorimeters with electrons, pions, kaons, and protons is discussed. The resolution for electrons was found to be 0.27/sqrt(E), and for hadrons the resolution was 0.554/sqrt(E) with a constant term of 2.6%. The performance of the calorimeters was tested on a neutron sample.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

The CLAS12 forward electromagnetic calorimeter

The CLAS12 Forward Detector includes six independent lead-scintillator electromagnetic sampling calorimeters to provide the primary electron trigger and extend the CLAS12 detection capability to photons and neutrons. Each calorimeter package consists of two modules, the legacy Electromagnetic Calorimeter (EC) previously used in the CLAS detector, and a new pre-shower calorimeter (PCAL) located in front of the EC to extend the total detector radiation length, in order to fully absorb the electromagnetic showers induced by electrons with energies up to 12 GeV. Both calorimeters use a novel triangular hodoscope geometry with stereo readout. The PCAL uses an upgraded design to provide the high spatial resolution necessary for reconstructing π 0 and η decays, and neutrons with high efficiency. Here, this paper treats the design, construction, and calibration of the PCAL and the preliminary combined performance of both detectors.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Studies of Cherenkov photon production in PbF 2 crystals using proton beams at Fermilab

Future lepton colliders such as the FCC-ee, CEPC, ILC, or a muon collider will collect large data samples that allow precision physics studies with unprecedented accuracy, especially when the data is collected by innovative state-of-the-art detectors. An electromagnetic calorimeter based on scintillating crystals, designed to separately record Cherenkov and scintillation light, can achieve precision measurements of electrons and photons without sacrificing jet energy resolution, given adequate light collection efficiency and separation. This paper presents initial measurements from a program aimed at developing such a calorimeter system for future colliders. Finally, we focus on using PbF 2 crystals to enhance the understanding of Cherenkov light collection, marking the first step in this endeavor.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

MPRAD: A Monte Carlo and ray-tracing code for the proton radiography in high-energy-density plasma experiments

Proton radiography is used in various high-energy-density (HED) plasma experiments. In this paper, we describe a Monte Carlo and raytracing simulation tool called multimegaelectronvolt proton radiography (MPRAD) that can be used for modeling the deflection of proton beams in arbitrary three dimensional electromagnetic fields as well as the diffusion of the proton beams by Coulomb scattering and stopping power. Specifically, the Coulomb scattering and stopping power models in cold matter and fully ionized plasma are combined using interpolation. We discuss the application of MPRAD in a few setups relevant to HED plasma experiments where the plasma density can play a role in diffusing the proton beams and affecting the prediction and interpretation of the proton images. It is shown how the diffusion due to plasma density can affect the resolution and dynamical range of the proton radiography.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Sagnac fourier spectrometer (SAFOS)

A technique and device to determine the spectrum of electromagnetic radiation in a certain range of wavelengths comprising: splitting said radiation into more than one beam; let these beams counter-propagate in a Sagnac-type ring interferometer; and imprinting a wavelength-dependent angular tilt onto the wavefront of each beam by at least one dispersive element which preferably is a transmission grating or grism; and re-combining the multiple beams on a detector that exhibits spatial resolution and can therefore resolve the fringes formed by interference; and perform the mathematical operations to determine the spectrum of said radiation from the obtained interferogram, wherein the dispersive element is mounted on a stage providing linear and/or rotational movement.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Diagnostic Systems in the Muon $g-2$ experiment at Fermilab

The muon anomalous magnetic moment, $a_\mu=\frac{g-2}{2}$, is a low-energy observable which can be both measured and computed to high precision, making it a sensitive test of the Standard Model and a probe for new physics. This anomaly was measured with a precision of $0.20$~parts per million (ppm) by the Fermilab's Muon g-2 (E989) experiment. The final goal of the E989 experiment is to reach a precision of $0.14$~ppm. The experiment is based on the measurement of the muon spin anomalous precession frequency, $\omega_a$, based on the arrival time distribution of high-energy decay positrons observed by 24 electromagnetic calorimeters, placed around the inner circumference of a $14$~m diameter storage ring, and on the precise knowledge of the storage ring magnetic field and of the beam time and space distribution. Achieving this level of precision requires strict control over systematics, which is ensured through several diagnostic devices. At the accelerator level, these devices monitor the quality of the injected beam (e.g., verifying that it has the correct momentum), while at the detector level, they track both the magnetic field and the gain of the calorimeters. In this work the devices and techniques used by the E989 experiment will be presented.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Electromagnetic Transient Modeling of Data Centers

This report serves as a user manual for the accompanying EMT model library developed by the National Laboratory of the Rockies (NLR) for various equipment in large data centers. The EMT model library enables detailed modeling of large data center loads for conducting grid stability studies. The EMT model library for data centers include detailed models of a 5.5 kW power supply unit (PSU), a 2.5 uninterruptible power supply (UPS), a 260 MW gas turbine-generator, a 500 kW motor load, and a 33 kW IT rack. These components represent all major equipment in data centers that need to be modeled for performing grid stability studies for data centers.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Demagnetization using a determined estimated magnetic state

A method for demagnetizing comprising positioning a core within the electromagnetic field generated by a first winding until the generated first electrical current is not substantially increasing, thereby determining a saturation current. A second voltage, having the opposite polarity, is then applied across the first winding until the generated second electrical current is approximately equal to the magnitude of the determined saturation current. The maximum magnetic flux within the core is then determined using the voltage across said first winding and the second current. A third voltage, having the opposite polarity, is then applied across the first winding until the core has a magnetic flux equal to approximately half of the determined maximum magnetic flux within the core.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗