Search NASA⌕ Search

SEARCH · Search NASA

Results for “Grid Load”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,423 records · Page 79

Preliminary Computational Analysis of the (HIRENASD) Configuration in Preparation for the Aeroelastic Prediction Workshop

This paper presents preliminary computational aeroelastic analysis results generated in preparation for the first Aeroelastic Prediction Workshop (AePW). These results were produced using FUN3D software developed at NASA Langley and are compared against the experimental data generated during the HIgh REynolds Number Aero- Structural Dynamics (HIRENASD) Project. The HIRENASD wind-tunnel model was tested in the European Transonic Windtunnel in 2006 by Aachen University0s Department of Mechanics with funding from the German Research Foundation. The computational effort discussed here was performed (1) to obtain a preliminary assessment of the ability of the FUN3D code to accurately compute physical quantities experimentally measured on the HIRENASD model and (2) to translate the lessons learned from the FUN3D analysis of HIRENASD into a set of initial guidelines for the first AePW, which includes test cases for the HIRENASD model and its experimental data set. This paper compares the computational and experimental results obtained at Mach 0.8 for a Reynolds number of 7 million based on chord, corresponding to the HIRENASD test conditions No. 132 and No. 159. Aerodynamic loads and static aeroelastic displacements are compared at two levels of the grid resolution. Harmonic perturbation numerical results are compared with the experimental data using the magnitude and phase relationship between pressure coefficients and displacement. A dynamic aeroelastic numerical calculation is presented at one wind-tunnel condition in the form of the time history of the generalized displacements. Additional FUN3D validation results are also presented for the AGARD 445.6 wing data set. This wing was tested in the Transonic Dynamics Tunnel and is commonly used in the preliminary benchmarking of computational aeroelastic software.

Chwalowski, Pawel↗

Challenges Associated with In-Situ Calibration of Load Cells in Force Limited Vibration Testing

The difference in mounting configuration between flight and test can significantly impact the effectiveness of the test in environmental vibration testing. Many tests are performed with large electrodynamic shakers, which utilize interfaces that seek to replicate a fixed base, such as slip tables and head expanders. This fixed base configuration is rarely seen in flight configurations; rather a more realistic configuration would include a flexible mounting structure with its own compliance and dynamics. This causes significant over and under tests in various frequency bands depending on the differences between the test article and fixture dynamics. The traditional way of avoiding these high loads is to limit the acceleration responses at multiple locations on the test article. However, the effectiveness of this approach is highly dependent upon the validity of the test article’s analytical in order to derive accurate acceleration response limit specifications. Also this technique requires limiting the acceleration responses at many locations throughout the test article, which may not be implementable due to such things as access and cleanliness issues An improved environmental vibration testing technique known as force limiting incorporates measurements of the forces between the test article and shaker system interface and limiting them to a specification that more accurately replicates the interface impedance of the structure the test article will be mounted to in flight. In effect this transforms the high mechanical impedance at the test article to shaker interface to more closely match the mechanical impedance of the flight interface, which avoids producing the unrealistically high interface loads. Typically force gauges or load cells are used to measure these interface forces. However, utilizing load cells can present a multitude of challenges depending upon such things as their installation method, geometric layout, and test fixture setup. Regardless, it is extremely important to perform an in-situ calibration of the load cells prior to vibration testing at any significant levels. This paper will discuss the challenges associated with utilizing load cells during the NASA Evolutionary Xenon Thruster – Commercial (NEXT-C) gridded ion thruster proto-flight vibration test performed at the NASA Glenn Research Center’s Structural Dynamics Laboratory.

Kenneth J Pederson↗

Challenges Associated with In-Situ Calibration of Load Cells in Force Limited Vibration Testing

The difference in mounting configuration between flight and test can significantly impact the effectiveness of the test in environmental vibration testing. Many tests are performed with large electrodynamic shakers, which utilize interfaces that seek to replicate a fixed base, such as slip tables and head expanders. This fixed base configuration is rarely seen in flight configurations; rather a more realistic configuration would include a flexible mounting structure with its own compliance and dynamics. This causes significant over and under tests in various frequency bands depending on the differences between the test article and fixture dynamics. The traditional way of avoiding these high loads is to limit the acceleration responses at multiple locations on the test article. However, the effectiveness of this approach is highly dependent upon the validity of the test article’s analytical in order to derive accurate acceleration response limit specifications. Also this technique requires limiting the acceleration responses at many locations throughout the test article, which may not be implementable due to such things as access and cleanliness issues An improved environmental vibration testing technique known as force limiting incorporates measurements of the forces between the test article and shaker system interface and limiting them to a specification that more accurately replicates the interface impedance of the structure the test article will be mounted to in flight. In effect this transforms the high mechanical impedance at the test article to shaker interface to more closely match the mechanical impedance of the flight interface, which avoids producing the unrealistically high interface loads. Typically force gauges or load cells are used to measure these interface forces. However, utilizing load cells can present a multitude of challenges depending upon such things as their installation method, geometric layout, and test fixture setup. Regardless, it is extremely important to perform an in-situ calibration of the load cells prior to vibration testing at any significant levels. This paper will discuss the challenges associated with utilizing load cells during the NASA Evolutionary Xenon Thruster – Commercial (NEXT-C) gridded ion thruster proto-flight vibration test performed at the NASA Glenn Research Center’s Structural Dynamics Laboratory.

K. J. Pederson↗

High Penetration PV: How High Can We Go?

Brochure highlighting NREL's partnership with SolarCity and Hawaiian Electric (HECO) to increase the penetration of solar photovoltaics on the electricity grid. To better understand the potential impact of transient overvoltages due to load rejection, NREL collaborated with SolarCity and HECO to run a series of tests measuring the magnitude and duration of load rejection overvoltage events and demonstrating the ability of advanced PV inverters to mitigate their impacts.

14 SOLAR ENERGY↗

Market-based Co-optimization of Energy and Ancillary Services with Distributed Energy Resource Flexibilities

Energy storage systems and flexible loads have attracted significant interests due to their capabilities to provide various grid services. In this paper, the flexibilities are optimally allocated among multiple distributed energy resource aggregators with energy storage systems and flexible buildings by the utility coordinator through market-based co-optimization. An iterative market clearing algorithm is developed to determine the optimal energy and ancillary service prices, with consideration of both local dynamics and network constraints. Simulation results demonstrate the effectiveness of the proposed algorithm and the benefits of co-optimizing the energy and ancillary service markets.

Ma, Ke↗

Exploring the Potential of Factory Installed Solar + Storage for Homebuilding

In recent years, an increasing number of grid disruptions due to intense weather events, natural disasters, and high peak loads resulted in increased interest in energy-resilient homes. Solar + storage (S+S) as an energy resiliency solution can provide continuity, onsite generation, and backup power during critical events. This project explored factory-installed solar plus storage (FISS) to overcome first cost and installation barriers and bring this resiliency solution to scale for single-family affordable and market-rate homebuyers. Guided by the principles of Lean manufacturing, the team explored how factories building high-performance zero energy modular homes can incorporate S+S into their existing construction system while improving quality and productivity and reducing the costs of the resilient energy system.

ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATION,↗

Novel PCM-based fin and tube heat exchanger system for building heating and cooling applications

In the United States, the building sector accounts for 40% of all energy use, and buildings are responsible for more than two-thirds of electricity consumption. Buildings remain the major driver of energy-related carbon emissions, and such emissions are projected to increase in the years ahead because of urbanization and population growth. To accomplish the low carbon energy goal in the building sector, phase change material (PCM)–based thermal energy storage (TES) is increasingly being adopted because it offers several advantages, such as reducing building peak load and energy consumption, enabling large scale deployment of renewables, and improving grid stability. The integration of TES with thermally anisotropic building envelopes (TABEs) is a promising solution because, TABE can redirect natural thermal energy from a building using hydronic loops to TES, and the stored energy can be used later for heating and cooling applications. In this study, we experimentally investigate the thermal performance of a novel fin-tube heat exchanger TES system designed for potential integration with a TABE. An experimental rig for a 5-gal PCM fin-tube heat exchanger system with water as the heat transfer medium is described which records temperatures at the heated and cooled boundaries of the system. Experimental observations provide insight into the role a TES system can play in offsetting a building’s heating and cooling demand and also offer a means to characterize the performance of PCMs for building applications. The scale and study presented in this work will help in the design of future thermal storage systems optimized for storage capacity while also accounting for overall system costs for building applications.

Tamraparni, Achutha↗

Optimum aggregation of geographically distributed flexible resources in strategic smart-grid/microgrid locations

This paper determines optimum aggregation areas for a given distribution network considering spatial distribution of loads and costs of aggregation. An elitist genetic algorithm combined with a hierarchical clustering and a Thevenin network reduction is implemented to compute strategic locations and aggregate demand within each area. The aggregation reduces large distribution networks having thousands of nodes to an equivalent network with few aggregated loads, thereby significantly reducing the computational burden. Furthermore, it not only helps distribution system operators in making faster operational decisions by understanding during which time of the day will be in need of flexibility, from which specific area, and in which amount, but also enables the flexibilities stemming from small distributed resources to be traded in various power/energy markets. A combination of central and local aggregation scheme where a central aggregator enables market participation, while local aggregators materialize the accepted bids, is implemented to realize this concept. The effectiveness of the proposed method is evaluated by comparing network performances with and without aggregation. Finally, for a given network configuration, steady-state performance of aggregated network is significantly accurate (≈ ±1.5% error) compared to very high errors associated with forecast of individual consumer demand.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Solar Power and the Electric Grid, Energy Analysis (Fact Sheet)

In today's electricity generation system, different resources make different contributions to the electricity grid. This fact sheet illustrates the roles of distributed and centralized renewable energy technologies, particularly solar power, and how they will contribute to the future electricity system. The advantages of a diversified mix of power generation systems are highlighted.

14 SOLAR ENERGY↗

Grid Forming Fast Frequency Response for PMSG-Based Wind Turbines

Electric power systems are undergoing a rapid transition from fuel-based generation using synchronous generators to renewable generation interfaced by power electronics. In this context, a key challenge is using renewable generation with limited controllability to contribute to power system stability. In this work, we investigate grid-forming control of permanent magnet synchronous generator (PMSG) wind turbines. The proposed control and curtailment strategy supports the entire spectrum of standard functions of grid-following (e.g. maximum power point tracking (MPPT) and grid-forming control (e.g., primary frequency control) without explicit mode switching. A detailed case study is used to compare the performance of the proposed control at operating points corresponding to MPPT and frequency control with standard grid-forming and grid-following controls. Further, the results demonstrate that (i) the proposed energy balancing grid forming control is self-synchronizing in MPPT mode, (ii) the (limited) energy storage and controllability of wind turbines can be adequately utilized to provide grid support, and (ii) the proposed control exhibits good performance under variable wind speeds and does not result in a significant increase of wind turbine fatigue loads.

17 WIND ENERGY↗

Techno-Economic Assessment of Data Center Load Demand Powered by Small Modular Reactors and Distributed Energy Resources

The rapid increase in data center energy demand, driven by AI and large-scale data processing, poses significant challenges to global energy infrastructure. Data centers require substantial and reliable energy for continuous operations and high-performance computing. Current electrical grids face issues such as transmission bottlenecks and aging infrastructure, making it difficult to meet these demands. Integrating inverter-based-resources (IBRs) like solar and wind presents both opportunities and challenges due to their intermittent nature. Small Modular Reactors (SMRs) offer a promising solution with their enhanced safety, modularity, reliability, and scalability, providing consistent base load power ideal for data center operations. This study presents a comprehensive techno-economic assessment of powering data center load demand using a combination of SMRs and IBRs with grid-connected and islanded mode. This study utilized Idaho National Laboratory’s (INL) HPC data center hourly load profiles and Xendee microgrid optimization platform to conduct the analysis. In this configuration, SMRs serves as the primary base load power source, consistently providing a steady supply of electricity necessary to meet the minimum load demand of the data center with support from the IBRs. Key performance indicators such as Levelized Cost of Electricity (LCOE), Net Present Value (NPV) has been calculated to assess the economic feasibility. The findings from this research will underscore the strategic benefits of integrating SMR plant with DERs – particularly for critical infrastructure load such as data centers.

14 - SOLAR ENERGY↗

A Preliminary Study of Building a Transmission Overlay for Regional US Power Grid

Many European countries have taken steps toward a Supergrid in order to transmit large amount of intermittent and remote renewable energy over long distance to load centers. In the US, as the expected increase in renewable generation and electricity demand, similar problem arises. A potential solution is to upgrade the transmission system at a higher voltage by constructing a new overlay grid. This paper will first address basic requirements for such an overlay grid. Potential transmission technologies will also be discussed. A multi-terminal VSC HVDC model is developed in DSATools to implement the overlay grid and a test case on a regional NPCC system will be simulated. Another test system of entire US power grid, with three different interconnections tied together using back-to-back HVDC, is also introduced in this paper. Building an overlay system on top of this test case is ongoing, and will be discussed in future work.

Lei, Yin↗

Integration of optimal operational dispatch and controller determined dynamics for microgrid survivability

We present that the reliability and resilience of the electrical power grids are essential to industry, economy and society. Microgrids that are able to island from the bulk electrical grid are one technology that may vastly improve electrical power service to customer loads. To achieve these improvements, an islanded microgrid should be able to operate through the loss of one of its generators without shedding electrical load. The loss of one generator will typically result in significant additional loads, including transient overloads, being placed on the remaining generators. There is also the possibility of additional generator tripping during these processes (i.e. cascading failures), which would likely result in the collapse of the microgrid. The novelty of our work consists in incorporating dynamic models of generator controllers into a microgrid optimal dispatch formulation with the ultimate goal to avoid operational failures and ensure the “survivability” of all-inverter microgrids to generator loss and transient overloads. The integration of generator and controller dynamics into the optimal dispatch formulation significantly increases the computational complexity. As we develop algorithms to restore speed of the optimization, our method can be readily implemented into a new operational strategy capable of an unprecedented level of reliability against generator contingencies. In addition, we quantitatively illustrate the effect of the survivability constraints on the microgrid operating costs and how the related trade-off between capital and operating costs should be taken into account at the design stage. Finally, the methods developed here also apply to the dispatch of off-grid microgrids.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Variability of Photovoltaic Power in the State of Gujarat Using High Resolution Solar Data

India has ambitious goals for high utilization of variable renewable power from wind and solar, and deployment has been proceeding at a rapid pace. The western state of Gujarat currently has the largest amount of solar generation of any Indian state, with over 855 Megawatts direct current (MWDC). Combined with over 3,240 MW of wind, variable generation renewables comprise nearly 18% of the electric-generating capacity in the state. A new historic 10-kilometer (km) gridded solar radiation data set capturing hourly insolation values for 2002-2011 is available for India. We apply an established method for downscaling hourly irradiance data to one-minute irradiance data at potential PV power production locations for one year, 2006. The objective of this report is to characterize the intra-hour variability of existing and planned photovoltaic solar power generation in the state of Gujarat (a total of 1.9 gigawatts direct current (GWDC)), and of five possible expansion scenarios of solar generation that reflect a range of geographic diversity (each scenario totals 500-1,000 MW of additional solar capacity). The report statistically analyzes one year's worth of power variability data, applied to both the baseline and expansion scenarios, to evaluate diurnal and seasonal power fluctuations, different timescales of variability (e.g., from one to 15 minutes), the magnitude of variability (both total megawatts and relative to installed solar capacity), and the extent to which the variability can be anticipated in advance. The paper also examines how Gujarat Energy Transmission Corporation (GETCO) and the Gujarat State Load Dispatch Centre (SLDC) could make use of the solar variability profiles in grid operations and planning.

14 SOLAR ENERGY↗

Variability of Power from Large-Scale Solar Photovoltaic Scenarios in the State of Gujarat (Presentation)

India has ambitious goals for high utilization of variable renewable power from wind and solar, and deployment has been proceeding at a rapid pace. The western state of Gujarat currently has the largest amount of solar generation of any Indian state, with over 855 Megawatts direct current (MWDC). Combined with over 3,240 MW of wind, variable generation renewables comprise nearly 18% of the electric-generating capacity in the state. A new historic 10-kilometer (km) gridded solar radiation data set capturing hourly insolation values for 2002-2011 is available for India. We apply an established method for downscaling hourly irradiance data to one-minute irradiance data at potential PV power production locations for one year, 2006. The objective of this report is to characterize the intra-hour variability of existing and planned photovoltaic solar power generation in the state of Gujarat (a total of 1.9 gigawatts direct current (GWDC)), and of five possible expansion scenarios of solar generation that reflect a range of geographic diversity (each scenario totals 500-1,000 MW of additional solar capacity). The report statistically analyzes one year's worth of power variability data, applied to both the baseline and expansion scenarios, to evaluate diurnal and seasonal power fluctuations, different timescales of variability (e.g., from one to 15 minutes), the magnitude of variability (both total megawatts and relative to installed solar capacity), and the extent to which the variability can be anticipated in advance. The paper also examines how Gujarat Energy Transmission Corporation (GETCO) and the Gujarat State Load Dispatch Centre (SLDC) could make use of the solar variability profiles in grid operations and planning.

14 SOLAR ENERGY↗

Variability of Power from Large-Scale Solar Photovoltaic Scenarios in the State of Gujarat: Preprint

India has ambitious goals for high utilization of variable renewable power from wind and solar, and deployment has been proceeding at a rapid pace. The western state of Gujarat currently has the largest amount of solar generation of any Indian state, with over 855 Megawatts direct current (MWDC). Combined with over 3,240 MW of wind, variable generation renewables comprise nearly 18% of the electric-generating capacity in the state. A new historic 10-kilometer (km) gridded solar radiation data set capturing hourly insolation values for 2002-2011 is available for India. We apply an established method for downscaling hourly irradiance data to one-minute irradiance data at potential PV power production locations for one year, 2006. The objective of this report is to characterize the intra-hour variability of existing and planned photovoltaic solar power generation in the state of Gujarat (a total of 1.9 gigawatts direct current (GWDC)), and of five possible expansion scenarios of solar generation that reflect a range of geographic diversity (each scenario totals 500-1,000 MW of additional solar capacity). The report statistically analyzes one year's worth of power variability data, applied to both the baseline and expansion scenarios, to evaluate diurnal and seasonal power fluctuations, different timescales of variability (e.g., from one to 15 minutes), the magnitude of variability (both total megawatts and relative to installed solar capacity), and the extent to which the variability can be anticipated in advance. The paper also examines how Gujarat Energy Transmission Corporation (GETCO) and the Gujarat State Load Dispatch Centre (SLDC) could make use of the solar variability profiles in grid operations and planning.

14 SOLAR ENERGY↗

Heavy snow loads in Finnish forests respond regionally asymmetrically to projected climate change

This study examined the impacts of projected climate change on heavy snow loads on Finnish forests, where snow-induced forest damage occurs frequently. For snow-load calculations, we used daily data from five global climate models under representative concentration pathway (RCP) scenarios RCP4.5 and RCP8.5, statistically downscaled onto a high-resolution grid using a quantile-mapping method. Our results suggest that projected climate warming results in regionally asymmetric response on heavy snow loads in Finnish forests. In eastern and northern Finland, the annual maximum snow loads on tree crowns were projected to increase during the present century, as opposed to southern and western parts of the country. The change was rather similar both for heavy rime loads and wet snow loads, as well as for frozen snow loads. Only the heaviest dry snow loads were projected to decrease over almost the whole of Finland. Our results are aligned with previous snowfall projections, typically indicating increasing heavy snowfalls over the areas with mean temperature below -8 °C. In spite of some uncertainties related to our results, we conclude that the risk for snow-induced forest damage is likely to increase in the future in the eastern and northern parts of Finland, i.e. in the areas experiencing the coldest winters in the country. In conclusion, the increase is partly due to the increase in wet snow hazards but also due to more favourable conditions for rime accumulation in a future climate that is more humid but still cold enough.

54 ENVIRONMENTAL SCIENCES↗

The National Opportunity for Interoperability and its Benefits for a Reliable, Robust, and Future Grid Realized Through Buildings

Today, increasing numbers of intermittent generation sources (e.g., wind and photovoltaic) and new mobile intermittent loads (e.g., electric vehicles) can significantly affect traditional utility business practices and operations. At the same time, a growing number of technologies and devices, from appliances to lighting systems, are being deployed at consumer premises that have more sophisticated controls and information that remain underused for anything beyond basic building equipment operations. The intersection of these two drivers is an untapped opportunity and underused resource that, if appropriately configured and realized in open standards, can provide significant energy efficiency and commensurate savings on utility bills, enhanced and lower cost reliability to utilities, and national economic benefits in the creation of new markets, sectors, and businesses being fueled by the seamless coordination of energy and information through device and technology interoperability. Or, as the Quadrennial Energy Review puts it, “A plethora of both consumer-level and grid-level devices are either in the market, under development, or at the conceptual stage. When tied together through the information technology that is increasingly being deployed on electric utilities’ distribution grids, they can be an important enabling part of the emerging grid of the future. However, what is missing is the ability for all of these devices to coordinate and communicate their operations with the grid, and among themselves, in a common language — an open standard.” In this paper, we define interoperability as the ability to exchange actionable information between two or more systems within a home or building, or across and within organizational boundaries. Interoperability relies on the shared meaning of the exchanged information, with agreed-upon expectations and consequences, for the response to the information exchange.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗