Search NASA⌕ Search

SEARCH · Search NASA

Results for “INDUCTION SYSTEM”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,423 records · Page 79

Induction and Concurrent Taxanes Enhance Both the Pulmonary Metabolic Radiation Response and the Radiation Pneumonitis Response in Patients With Esophagus Cancer

Purpose: The primary aim of this study was to assess pulmonary radiation toxicity quantitatively in patients who received thoracic radiotherapy combined with induction and/or concurrent chemotherapy with or without taxanes for esophageal cancer. Methods and Materials: The study subjects were 139 patients treated at the University of Texas M.D. Anderson Cancer Center for esophageal cancer and who had undergone [{sup 18}F]-fluorodeoxyglucose positron emission tomography/computed tomography between November 1, 2003 and December 15, 2007 for disease restaging after chemoradiotherapy. The patients were grouped into those who had not received taxanes (Group 1), those who had received induction or concurrent taxanes (Group 2), and those who had received both induction and concurrent taxanes (Group 3). Clinical pulmonary toxicity was scored using the National Cancer Institute Common Terminology Criteria for Adverse Events, version 3. Linear regression was applied to the fluorodeoxyglucose uptake vs. radiation dose to determine the pulmonary metabolic radiation response (PMRR) for each case. The clinical toxicity scores and PMRR among the groups were evaluated for significance differences. Results: The crude rate of pneumonitis symptoms was 46%, 62%, and 74% for Group 1, 2, and 3, respectively. The analysis of variance test of log(PMRR) by treatment was significant (p = .0046). Group 3 had a 61% greater PMRR compared with Group 1 (p = .002). Group 2 had a 38% greater PMRR compared with Group 1 (p = .015). Finally, Group 3 had a 17% greater PMRR compared with Group 2 (p = .31). A PMRR enhancement ratio of 1.60 (95% confidence interval, 1.19-2.14) was observed for Group 3 vs. Group 1. Conclusion: Patients given induction and concurrent taxane chemotherapy had a significantly greater PMRR and clinical pneumonitis symptoms compared with the patients whose chemotherapy regimen did not include taxanes.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Improved efficiency and precise temperature control of low-frequency induction-heating pure iron vapor source on ECR ion source

Multiply charged ions to be used prospectively are produced from solid pure material in an electron cyclotron resonance ion source (ECRIS). Recently a pure iron source is also required for the production of caged iron ions in the fullerene in order to control cells in vivo in bio-nano science and technology. We adopt directly heating iron rod by induction heating (IH) because it has non-contact with insulated materials which are impurity gas sources. We choose molybdenum wire for the IH coils because it doesn't need water cooling. To improve power efficiency and temperature control, we propose to the new circuit without previously using the serial and parallel dummy coils (SPD) for matching and safety. We made the circuit consisted of inductively coupled coils which are thin-flat and helix shape, and which insulates the IH power source from the evaporator. This coupling coils circuit, i.e. insulated induction heating coil transformer (IHCT), can be move mechanically. The secondary current can be adjusted precisely and continuously. Heating efficiency by using the IHCT is much higher than those of previous experiments by using the SPD, because leakage flux is decreased and matching is improved simultaneously. We are able to adjust the temperature in heating the vapor source around melting point. And then the vapor pressure can be controlled precisely by using the IHCT. We can control {+-}10K around 1500 Degree-Sign C by this method, and also recognize to controlling iron vapor flux experimentally in the extreme low pressures. Now we come into next stage of developing induction heating vapor source for materials with furthermore high temperature melting points above 2000K with the IHCT, and then apply it in our ECRIS.

74 ATOMIC AND MOLECULAR PHYSICS↗

Supramolecular Double-Helix Formation by Diastereoisomeric Conformations of Configurationally Enantiomeric Macrocycles

Solid-state superstructures, resulting from assemblies programmed by homochirality, are attracting considerable attention. In addition, artificial double-helical architectures are being investigated, especially in relation to the ways in which homochiral small molecules can be induced to yield helical forms as a result of chiral induction. In this work, we report the highly specific self-assembly upon crystallization of a double-helical superstructure from an enantiopure macrocyclic dimer which adopts two diastereoisomeric conformations in a molar ratio of 1.5:1 in dimethyl sulfoxide. These two conformational diastereoisomers self-organize—and self-sort—in the crystalline phase in equimolar proportions to form two single-handed helices which are complementary to each other, giving rise to the assembly of a double helix that is stabilized by intermolecular [C–H···O] and π–π stacking interactions. The observed self-sorting phenomenon occurs on going from a mixed-solvent system containing two equilibrating conformational diastereoisomers, presumably present in unequal molar proportions, into the solid state. The diastereoisomeric conformations are captured upon crystallization in a 1:1 molar ratio in the double-helical superstructure, whose handedness is dictated by the choice of the enantiomeric macrocyclic dimer. The interconversion of the two conformational diastereoisomers derived from each configurationally enantiomeric macrocycle was investigated in CD 3 SOCD 3 solution by variable-temperature 1 H NMR spectroscopy (VT NMR) and circular dichroism (VT CD). The merging of the resonances for the protons corresponding to the two diastereoisomers at a range of coalescence temperatures in the VT NMR spectra and occurrence of the isosbestic points in the VT CD spectra indicate that the two diastereoisomers are interconverting slowly in solution on the 1 H NMR time scale but rapidly on the laboratory time scale. To the best of our knowledge, the self-assembly of such solid-state superstructures from two conformational diastereoisomers of a homochiral macrocycle is a rare, if not unique, occurrence.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

TU-H-BRA-05: A System Design for Integration of An Interior MRI and a Linear Accelerator

Purpose: MRI is a highly desirable modality to guide radiation therapy but it is difficult to combine a conventional MRI scanner directly with a linear accelerator (linac). An interior MRI (iMRI) concept has been proposed to acquire MRI images within a small field of view only covering targets and immediate surrounding tissues. The objective of this project is to design an interior MRI system to work with a linac using a magnet to provide a field around 0.2T in a cube of 20cm per side, and perform image reconstruction with a slightly inhomogeneous static magnetic fields. Methods: All the results are simulated using a commercially available software package, FARADY. In our design, a ring structure holds the iMRI system and also imbeds a linac treatment head. The ring is synchronized to the linac gantry rotation. Half of the ring is made of steel and becomes a magnetic flux return path (yoke) so that a strong magnetic field will be limited inside the iron circuit and fringe fields will be very weak. In order to increase the static magnetic field homogeneity, special steel magnet boots or tips were simulated. Three curved boots were designed based on two-dimensional curves: arc, parabola and hyperbola. Results: Different boot surfaces modify magnetic field distributions differently. With the same pair of neodymium-iron-boron (NdFeB) magnets, the magnetic induction at the centers are 0.217T, 0.201T, 0.204T, and 0.212T for flat, arc, parabola and hyperbola boots, respectively. The hyperbola boots lead to the most homogeneous results, the static magnetic field deviations are within 0.5% in a cube of 20cm, and can be further improved using shimming techniques. Conclusion: This study supports the concept of an iMRI design. Successful development of iMRI will provide crucial information for tumor delineation in radiation therapy.

43 PARTICLE ACCELERATORS↗

Multi-Collector Inductively Coupled Plasma Mass Spectrometer – Operational Performance Report

The INL made an assessment of the commercially available inductively coupled plasma mass spectrometers (ICPMS) for actinide analysis; emphasizing low detection limits for plutonium. INL scientists subsequently determined if plutonium was present on a swipe, at a 10 million atom decision level. This report describes the evaluation of ICPMS instruments and the operational testing of a new process for the dissolution, separation and analysis via ICPMS of swipes for plutonium and uranium. The swipe dissolution, plutonium and uranium isolation, separation and purification are wet chemistry methods following established procedures. The ICPMS is a commercially available multi-collector magnetic sector mass spectrometer that utilizes five ion counting detectors operating simultaneously. The instrument includes a sample introduction system allowing for sample volumes of < 1 mL to be reproducibly injected into the instrument with minimal waste of the sample solution, while maximizing the useable signal. The performance of the instrument was measured using SRM 996 ( 244 Pu spike) at concentrations of 12 parts per quadrillion (ppq, fg/mL) and with SRM 4350B Columbia River Sediment samples spiked onto swipes at the 10 million atom level. The measured limit of detection (LOD, defined as 3s) for 239 Pu is 310,000 atoms based upon the instrument blank data. The limit of quantification (LOQ defined as 10 s) for 239 Pu is 105,000 atoms. The measured limit of detection for 239 Pu from the SRM 4350B spiked onto a swipe was 2.7 million atoms with the limit of quantification being 9.0 million atoms.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Prospecting for Critical Minerals and Rare Earth Elements from Marcellus Shale in the Western Portion of the Appalachian Basin with Non-Destructive Core Characterization

Identification of sources for domestic critical minerals and rare earth elements (CM/REE) has been deemed essential for the energy transition by the United States Department of Energy (DOE). The U.S. DOE’s National Energy Technology Laboratory’s (NETL) Geomaterials Characterization Laboratory has performed non-destructive core characterizations on energy-relevant rock cores for the past decade. During this time, NETL has published over 36 technical reports and made the associated data publicly available. Much of this work focuses on unconventional shale gas, subsurface carbon storage systems, and carbon-ore. These efforts provide cm-scale petrophysical and elemental data, photographic documentation, detailed core descriptions, and computed tomography (CT) data for each well. This provides a first phase prospecting resource for CM/REE resources and can provide a map for pin-pointing intervals and lithologies for further development. Using historical core characterization data from 12 Marcellus wells from the western portion of the Appalachian Basin, this study builds an improved understanding of the chemostratigraphy of the basin. X-ray fluorescence (XRF) and CT images were used to determine lithologic intervals and potential ore bodies for further analysis, including benchtop digestion and inductively coupled plasma mass spectrometry (ICP-MS) to better understand the CM/REE enrichments.

Paronish, Thomas J.↗

PVA and PEG functionalised LSMO nanoparticles for magnetic fluid hyperthermia application

La{sub 0.7}Sr{sub 0.3}MnO{sub 3} magnetic nanoparticles are synthesized by a solution combustion method and functionalised with polyvinyl alcohol and polyethylene glycol. The induction heating characteristics of coated magnetic nanoparticles (42 °C) were observed at a reasonably low concentration (5 mg/mL). Remarkably, coated magnetic nanoparticles exhibited a promisingly high specific absorption rate with varying magnetic field and constant frequency. The surface analysis is carried out by X-ray photoelectron spectroscopy. A reduction in the agglomeration of the particles was observed when the magnetic nanoparticles were functionalised with polyvinyl alcohol or polyethylene glycol and can be confirmed by transmission electron microscopy and dynamic light scattering studies. Vibrating sample magnetometer measurements indicate superparamagnetic behaviour at room temperature before and after coating. Colloidal stability revealed a considerably higher zeta potential value for coated system. In vitro cytotoxicity test of the magnetic nanoparticles indicates that coated nanoparticles have no significant effect on cell viability within the tested concentrations (1–5 mg mL{sup -1}) as compared to uncoated La{sub 0.7}Sr{sub 0.3}MnO{sub 3}. All these findings explore the potentiality of La{sub 0.7}Sr{sub 0.3}MnO{sub 3} nanoparticles for magnetic fluid hyperthermia. - Highlights: • Surface functionalization of LSMO nanoparticles — first time with PVA • Surface functionalization of LSMO nanoparticles — first time with PEG • BSA protein — first time used as dispersion medium for stability of LSMO nanoparticles • The heating ability observed at low concentration • Improved efficiency of magnetic fluid hyperthermia treatment with surfactants.

77 NANOSCIENCE AND NANOTECHNOLOGY↗

Posttranslational ruling of xanthine oxidase activity in bovine milk by its substrates

The aims of this study were to test the hypothesis that the substrates of xanthine oxidase (XO), xanthine and hypoxanthine, are consumed while the milk is stored in the gland between milkings, and to explore how XO activity responds to bacteria commonly associated with subclinical infections in the mammary gland. Freshly secreted milk was obtained following complete evacuation of the gland and induction of milk ejection with oxytocin. In bacteria-free fresh milk xanthine and hypoxanthine were converted to uric acid within 30 min (T{sub 1/2} {approx} 10 min), which in turn provides electrons for formation of hydrogen peroxide and endows the alveolar lumen with passive protection against invading bacteria. On the other hand, the longer residence time of milk in the cistern compartment was not associated with oxidative stress as a result of XO idleness caused by exhaustion of its physiological fuels. The specific response of XO to bacteria species and the resulting bacteria-dependent nitrosative stress further demonstrates that it is part of the gland immune system.

60 APPLIED LIFE SCIENCES↗

In Situ Methods for Monitoring Silver Nanoparticle Sulfidation in Simulated Waters

To probe the transformation pathways of metallic nanomaterials, measurement tools capable of detecting and characterizing the broad distribution of products with limited perturbation are required. Here, we demonstrate the detection of transformation products resulting from 40 kDa PVP-coated silver nanoparticles (AgNPs) reacted in aerated, sulfide-containing water and EPA moderately hard reconstituted water standard. Using single particle inductively coupled plasma mass spectrometry, silver mass preservation in primary AgNP populations during sulfidation was observed under all reaction conditions examined. Disparate sensitivities of Ag + and AgNPs to different media were observed, limiting confidence in the measured dissolved fraction. Examination with hyphenated asymmetric flow field-flow fractionation (A4F) methods supported similar mass preservation. Using flow-cell FTIR measurements, we provide direct evidence for the preservation of PVP-coatings in the presence of Na 2 S and fulvic acid, which we attributed to the observed, unprecedented Ag preservation. Using A4F and X-ray scattering, sub 10 nm AgNP populations, which have gone nearly unstudied in environmental systems, were detected and characterized in all the pristine and transformed product distributions examined. Lastly, by distinguishing Ag + from individual AgNPs, quantification of each population becomes tractable, which is a critical measurement need for toxicity testing and predicting NP fate in engineered and natural systems.

54 ENVIRONMENTAL SCIENCES↗

Feedback control design for non-inductively sustained scenarios in NSTX-U using TRANSP

This paper examines a method for real-time control of non-inductively sustained scenarios in NSTX-U by using TRANSP, a time-dependent integrated modeling code for prediction and interpretive analysis of tokamak experimental data, as a simulator. The actuators considered for control in this work are the six neutral beam sources and the plasma boundary shape. To understand the response of the plasma current, stored energy, and central safety factor to these actuators and to enable systematic design of control algorithms, simulations were run in which the actuators were modulated and a linearized dynamic response model was generated. A multi-variable model-based control scheme that accounts for the coupling and slow dynamics of the system while mitigating the effect of actuator limitations was designed and simulated. Simulations show that modest changes in the outer gap and heating power can improve the response time of the system, reject perturbations, and track target values of the controlled values.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

A fully ro-vibrationally resolved corona model for the molecular hydrogen Fulcher-𝛼 system

A ro-vibrationally resolved corona model for the molecular hydrogen Fulcher-𝛼 transition based on the Yacora solver is introduced. The model couples 1365 ro-vibrational levels of the 𝑋 1 ⁢𝛴$^+_𝑔$, 𝑑 3⁢ 𝛱 𝑢 and 𝑎 3 ⁢𝛴$^+_𝑔$ states via electron impact excitation from the ground state into the 𝑑 3⁢ 𝛱 𝑢 state and subsequent spontaneous emission into the 𝑎 3 ⁢𝛴$+_𝑔$ state. For the process of electron impact excitation a set of 45260 fully ro-vibrationally resolved cross sections calculated with the molecular convergent close-coupling (MCCC) method in the adiabatic-nuclei formulation is applied. The MCCC cross sections are compared with results of a scaling method used in other works, demonstrating the need for dedicated ro-vibrationally resolved cross sections. By post-processing the model output, entire Fulcher spectra can be simulated. These spectra are benchmarked with measurements from an inductively coupled plasma discharge at a pressure between 1.1–10 Pa and a RF power of 700 W. The model results agree very well with the experiment both in relative shape and in absolute value. A non-ro-vibrationally resolved, purely electronically resolved collisional radiative model for molecular hydrogen (including further states and reaction channels) is applied to investigate the validity of the corona approximation for the benchmark plasmas and the relevance of possible process extensions of the corona model. Furthermore, the influence of collisional quenching, autoionization and predissociation is discussed.

74 ATOMIC AND MOLECULAR PHYSICS↗

Appropriateness and Readiness of Cold Crucible Vitrification of Calcine Solids at the Idaho Site and H-Canyon Effluent at the Savannah River Site

This report summarizes the results from an assessment of the technology readiness and deployment of cold crucible induction melter (CCIM) technology to vitrify high level waste (HLW) calcine solids at the Idaho Site and H-Canyon liquid effluent at the Savannah River Site (SRS). The assessment was requested by the Department of Energy’s Office of Environmental Management (DOE-EM), but is not a DOE 413-3-4a assessment for technology deployment. A joint Savannah River National Laboratory (SRNL) and Fluor Idaho Cleanup Project (ICP) team with subject matter experts evaluated the existent literature and experience both within the DOE as well as relevant external experience. The technology assessment focused on the site-specific technology readiness and appropriateness based on a number of system factors including feasibility and appropriateness of the technology for the specific site application, the potential extent of the regulatory and design challenges, and evaluation of the ability to deploy within the treatment needs of each site. This initial assessment provides information to support DOE-EM in making a go/no-go decision to carry out additional work on the technology maturation for critical decisions and planning.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Theory, modeling and simulation of superconducting qubits

We analyze the dynamics of a qubit-resonator system coupled with a thermal bath and external electromagnetic fields. Using the evolution equations for the set of Heisenberg operators that describe the whole system, we derive an expression for the resonator field, that includes the resonator-drive, the resonator-bath, and resonator-qubit interactions. The renormalization of the resonator frequency, caused by the qubit-resonator interaction, is accounted for. Using the solutions for the resonator field, we derive the equation that describes the qubit dynamics. The dependence of the qubit evolution during the measurement time on the fidelity of a single-shot measurement is studied. The relation between the fidelity and measurement time is shown explicitly. We proposed a novel adiabatic method for the phase qubit measurement. The method utilizes a low-frequency, quasi-classical resonator inductively coupled to the qubit. The resonator modulates the qubit energy, and the back reaction of the qubit causes a shift in the phase of the resonator. The resonator phase shift can be used to determine the qubit state. We have simulated this measurement taking into the account the energy levels outside the phase qubit manifold. We have shown that, for qubit frequencies in the range of 8-12GHZ, a resonator frequency of 500 MHz and a measurement time of 100 ns, the phase difference between the two qubit states is greater than 0.2 rad. This phase difference exceeds the measurement uncertainty, and can be detected using a classical phase-meter. A fidelity of 0.9999 can be achieved for a relaxation time of 0.5 ms. We also model and simulate a microstrip-SQUID amplifier of frequency about 500 MHz, which could be used to amplify the resonator oscillations in the phase qubit adiabatic measurement. The voltage gain and the amplifier noise temperature are calculated. We simulate the preparation of a generalized Bell state and compute the relaxation times required for achieving high fidelities. We consider two capacitively coupled phase qubits similar to that used in the experimental work of R. Bialczak et al. (Nature Physics, 6, 409, 2010). The Bell state was created using a NOT gate and a universal entangling gate. We solved the equation of motion for the density matrix with the Bloch relaxation times, T{sub 1} and T{sub 2}. For every qubit we took into consideration all the states in the shallow well including the states outside the qubit manifold. Also we took into consideration unwanted interaction between the qubits during the application of the NOT gate. The NOT gate was implemented using a Gaussian pulse assuming the frequency difference between the two qubits is 200 MHz. An entangling gate was implemented reducing this frequency difference to zero. We have found the optimal parameters for the Gaussian pulse and the optimal duration for the entangling gate. We have shown that the maximum fidelity of 0.99 can be achieved for the minimum relaxation time, T{sub 1} = 1.2 {micro}s, if T{sub 2} = 2T{sub 1}. By slightly increasing the required value of T{sub 1}, one can sharply reduce the required value for T{sub 2}.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Polarimetry-Interferometry Diagnostic for Magnetic Field and Magnetic Fluctuation Measurements in High-Performance and Long-Pulse Tokamaks (Final Report)

In this grant, we executed a multi-year plan to develop an advanced Faraday-effect polarimeter-interferometer system to address both fluctuation and equilibrium diagnostic needs by providing a measurement of the plasma internal magnetic field fluctuations (including non-axisymmetric 3-D perturbations) and plasma vertical position. This diagnostic included both fast time response and low phase noise so that both the temporal dynamics of equilibrium quantities as well as high-frequency electromagnetic fluctuations could be measured simultaneously, adding new and unique measurement capabilities for the core of high-temperature plasmas. The combined polarimeter-interferometer diagnostic development was applied primarily to the tokamak magnetic configuration, focusing on high-performance regimes including H-mode, reversed shear advanced tokamak scenarios, and non-inductive current drive.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Total Mercury Analysis Comparison: Deployment of Analytical Method for the Savannah River Site Liquid Waste System

A direct mercury analyzer (DMA; EPA 7473) and Cold Vapor Atomic Absorption Spectroscopy (CVAAS; EPA 245.2) have been used to analyze samples high in methylmercury and other forms of mercury with oxidation states of Hg o (elemental), Hg 1+ (mercurous), and/or Hg 2+ (mercuric) to determine analytical data equivalency for total mercury. The DMA instrument has been determined to be the preferred method based on both simulated and radioactive sample testing due to analytical results and ease of use in a radiological hood. SRNL made a number of modifications to the DMA instrument and analysis method to limit the amount of time personnel are required to work in a radiological environment. Equivalency is based on comparative statistical evaluation of the results from: spike solutions/simulants, Tank 50 samples, Mixed Analyte Performance Evaluation Program (MAPEP) samples, and Modular Caustic-Side Solvent Extraction Unit (MCU) solvent samples. SRNL performed a cross-comparison of results using CVAAS, DMA, and Inductively Coupled Plasma Mass Spectrometer (ICP-MS), as well as independent analysis from an offsite laboratory (using cold vapor sample processing with atomic fluorescence detection, EPA 1631). All data were within the combined uncertainty (2σ ± 20%) of the CVAAS and DMA methods

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Mercury CEM Calibration

Mercury continuous emissions monitoring systems (CEMS) are being implemented in over 800 coal-fired power plant stacks. The power industry desires to conduct at least a full year of monitoring before the formal monitoring and reporting requirement begins on January 1, 2009. It is important for the industry to have available reliable, turnkey equipment from CEM vendors. Western Research Institute (WRI) is working closely with the Electric Power Research Institute (EPRI), the National Institute of Standards and Technology (NIST), and the Environmental Protection Agency (EPA) to facilitate the development of the experimental criteria for a NIST traceability protocol for dynamic elemental mercury vapor generators. The generators are used to calibrate mercury CEMs at power plant sites. The Clean Air Mercury Rule (CAMR) which was published in the Federal Register on May 18, 2005 requires that calibration be performed with NIST-traceable standards (Federal Register 2007). Traceability procedures will be defined by EPA. An initial draft traceability protocol was issued by EPA in May 2007 for comment. In August 2007, EPA issued an interim traceability protocol for elemental mercury generators (EPA 2007). The protocol is based on the actual analysis of the output of each calibration unit at several concentration levels ranging initially from about 2-40 {micro}g/m{sup 3} elemental mercury, and in the future down to 0.2 {micro}g/m{sup 3}, and this analysis will be directly traceable to analyses by NIST. The document is divided into two separate sections. The first deals with the qualification of generators by the vendors for use in mercury CEM calibration. The second describes the procedure that the vendors must use to certify the generator models that meet the qualification specifications. The NIST traceable certification is performance based, traceable to analysis using isotope dilution inductively coupled plasma/mass spectrometry performed by NIST in Gaithersburg, MD. The outputs of mercury generators are compared to one another using a nesting procedure which allows direct comparison of one generator with another and eliminates analyzer variability effects. The qualification portion of the EPA interim traceability protocol requires the vendors to define generator performance as affected by variables such as pressure, temperature, line voltage, and shipping. WRI is focusing efforts to determine actual generator performance related to the variables defined in the qualification portion of the interim protocol. The protocol will then be further revised by EPA based on what can actually be achieved with the generators. Another focus of the study is to evaluate approaches for field verification of generator performance. Upcoming work includes evaluation of oxidized mercury calibration generators, for which a separate protocol will be prepared by EPA. In addition, the variability of the spectrometers/analyzers under various environmental conditions needs to be defined and understood better. A main objective of the current work is to provide data on the performance and capabilities of elemental mercury generator/calibration systems for the development of realistic NIST traceability protocols for mercury vapor standards for continuous emission CEM calibration. This work is providing a direct contribution to the enablement of continuous emissions monitoring at coal-fired power plants in conformance with the CAMR. EPA Specification 12 states that mercury CEMs must be calibrated with NIST-traceable standards (Federal Register 2005). The initial draft of an elemental mercury generator traceability protocol was circulated by EPA in May 2007 for comment, and an interim protocol was issued in August 2007 (EPA 2007). Initially it was assumed that the calibration and implementation of mercury CEMs would be relatively simple, and implementation would follow the implementation of the Clean Air Interstate Rule (CAIR) SO{sub 2} and NO{sub x} monitoring, and sulfur emissions cap and trade. However, mercury has proven to be significantly more difficult to accurately determine than was originally thought. The purpose of the current phase of this project is to evaluate issues related to the use of dynamic elemental mercury calibrators that are based on mercury vapor headspace above elemental mercury at a particular temperature.

01 COAL, LIGNITE, AND PEAT↗

Distinct notch signaling expression patterns between nucleoside and nucleotide analogues treatment for hepatitis B virus infection

Highlights: • Notch signaling inhibited by nucleoside analogues treatment under HBV infection. • Upregulation of Notch signaling after nucleotide analogues administration. • Reduction of Foxp3 expression by both nucleotide and nucleoside analogues treatment. • Activation of phosphorylated mTORC2–Akt cascade after nucleotide analogue treatment. Nucleos(t)ide analogues therapies are currently approved for the treatment of chronic hepatitis B virus (HBV) infection, which effectively suppress HBV replication and correlate with the anti-HBV-specific immune response. Notch signaling serves pleiotropic roles in the immune system that also contribute to virus-specific immunity. In this study, we assessed Notch signal-related gene expression after administrating nucleoside or nucleotide analogues to HBV-replicating cells and clinical liver tissues. We found distinct Notch signaling expression patterns under nucleos(t)ide analogues therapies, with high expression for nucleotide analogues (adefovir pivoxil or tenofovir disoproxil fumarate) and low expression for nucleoside analogues (lamivudine or entecavir) in the presence of HBV infection. Furthermore, activation of mammalian target of rapamycin (mTOR)-Akt (Ser473) phosphorylation was also observed after nucleotide analogue treatment. In conclusion, nucleoside and nucleotide analogues displayed different patterns of Notch signaling activity under HBV infection, and the induction of mTORC2-Akt (Ser473) phosphorylation may contribute to nucleotide analogues-mediated Notch signaling activation.

60 APPLIED LIFE SCIENCES↗