Search NASA⌕ Search

SEARCH · Search NASA

Results for “IRRADIATION DEVICES”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,423 records · Page 79

CALMOS: Innovative device for the measurement of nuclear heating in material testing reactors

An R and D program has been carried out since 2002 in order to improve gamma heating measurements in the 70 MWth OSIRIS Material Testing Reactor operated by CEA's Nuclear Energy Div. at the Saclay research center. Throughout this program an innovative calorimetric probe associated to a specific handling system has been designed in order to make measurements both along the fissile height and on the upper part of the core, where nuclear heating rates still remain high. Two mock-ups of the probe were manufactured and tested in 2005 and 2009 in ex-core area of OSIRIS reactor for the process validation, while a displacement system has been especially designed to move the probe axially. A final probe has been designed thanks to modeling results and to preliminary measurements obtained with mock-ups irradiated to a heating level of 2W/g, This paper gives an overview of the development, describes the calorimetric probe, and expected advantages such as the possibility to use complementary methods to get the nuclear heating measurement. Results obtained with mock-ups irradiated in ex-core area of the reactor are presented and discussed. (authors)

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Toward optimizing patient-specific IMRT QA techniques in the accurate detection of dosimetrically acceptable and unacceptable patient plans

Purpose: The authors investigated the performance of several patient-specific intensity-modulated radiation therapy (IMRT) quality assurance (QA) dosimeters in terms of their ability to correctly identify dosimetrically acceptable and unacceptable IMRT patient plans, as determined by an in-house-designed multiple ion chamber phantom used as the gold standard. A further goal was to examine optimal threshold criteria that were consistent and based on the same criteria among the various dosimeters. Methods: The authors used receiver operating characteristic (ROC) curves to determine the sensitivity and specificity of (1) a 2D diode array undergoing anterior irradiation with field-by-field evaluation, (2) a 2D diode array undergoing anterior irradiation with composite evaluation, (3) a 2D diode array using planned irradiation angles with composite evaluation, (4) a helical diode array, (5) radiographic film, and (6) an ion chamber. This was done with a variety of evaluation criteria for a set of 15 dosimetrically unacceptable and 9 acceptable clinical IMRT patient plans, where acceptability was defined on the basis of multiple ion chamber measurements using independent ion chambers and a phantom. The area under the curve (AUC) on the ROC curves was used to compare dosimeter performance across all thresholds. Optimal threshold values were obtained from the ROC curves while incorporating considerations for cost and prevalence of unacceptable plans. Results: Using common clinical acceptance thresholds, most devices performed very poorly in terms of identifying unacceptable plans. Grouping the detector performance based on AUC showed two significantly different groups. The ion chamber, radiographic film, helical diode array, and anterior-delivered composite 2D diode array were in the better-performing group, whereas the anterior-delivered field-by-field and planned gantry angle delivery using the 2D diode array performed less well. Additionally, based on the AUCs, there was no significant difference in the performance of any device between gamma criteria of 2%/2 mm, 3%/3 mm, and 5%/3 mm. Finally, optimal cutoffs (e.g., percent of pixels passing gamma) were determined for each device and while clinical practice commonly uses a threshold of 90% of pixels passing for most cases, these results showed variability in the optimal cutoff among devices. Conclusions: IMRT QA devices have differences in their ability to accurately detect dosimetrically acceptable and unacceptable plans. Field-by-field analysis with a MapCheck device and use of the MapCheck with a MapPhan phantom while delivering at planned rotational gantry angles resulted in a significantly poorer ability to accurately sort acceptable and unacceptable plans compared with the other techniques examined. Patient-specific IMRT QA techniques in general should be thoroughly evaluated for their ability to correctly differentiate acceptable and unacceptable plans. Additionally, optimal agreement thresholds should be identified and used as common clinical thresholds typically worked very poorly to identify unacceptable plans.

60 APPLIED LIFE SCIENCES↗

WE-AB-303-04: A Tissue Model of Cherenkov Emission From the Skin Surface During Megavoltage X-Ray Radiotherapy

Purpose: To develop a tissue model of Cherenkov radiation emitted from the skin surface during external beam radiotherapy. Imaging Cherenkov radiation emitted from human skin allows visualization of the beam position and potentially surface dose estimates, and our goal is to characterize the optical properties of these emissions. Methods: We developed a Monte Carlo model of Cherenkov radiation generated in a semi-infinite tissue slab by megavoltage x-ray beams with optical transmission properties determined by a two-layered skin model. We separate the skin into a dermal and an epidermal layer in our model, where distinct molecular absorbers modify the Cherenkov intensity spectrum in each layer while we approximate the scattering properties with Mie and Rayleigh scattering from the highly structured molecular organization found in human skin. Results: We report on the estimated distributions of the Cherenkov wavelength spectrum, emission angles, and surface distribution for the modeled irradiated skin surface. The expected intensity distribution of Cherenkov radiation emitted from skin shows a distinct intensity peak around 475 nm, the blue region of the visible spectrum, between a pair of optical absorption bands in hemoglobin and a broad plateau beginning near 600 nm and extending to at least 700 nm where melanin and hemoglobin absorption are both low. We also find that the Cherenkov intensity decreases with increasing angle from the surface normal, the majority being emitted within 20 degrees of the surface normal. Conclusion: Our estimate of the spectral distribution of Cherenkov radiation emitted from skin indicates an advantage to using imaging devices with long wavelength spectral responsivity. We also expect the most efficient imaging to be near the surface normal where the intensity is greatest; although for contoured surfaces, the relative intensity across the surface may appear to vary due to decreasing Cherenkov intensity with increased angle from the skin normal. This research was supported in part by a GAANN Fellowship from the Department of Education.

60 APPLIED LIFE SCIENCES↗

A new set-up for in-situ probing of radiation effects in materials and electronic devices

The micro-probe facility installed at the Van de Graff accelerator at CTN/IST permits simultaneous measurements of Rutherford Backscattering Spectrometry (RBS), Particle Induced X-ray Emission (PIXE) and Iono-Luminescence (IL). Here we present a recent up-grade of the measurement chamber allowing improved optical sensitivity in IL measurements and opening the possibility to perform simultaneously electrical measurements. Combinations of all these characterization techniques make this setup a powerful tool to characterize and modify different materials with spatial resolution. In particular, it can be used to study radiation effects in different materials and electronic devices in-situ. IL is a luminescence technique that uses the ion beam as the excitation source. Compared with other luminescence techniques with spatial resolution like Cathodoluminescence, this technique has the advantage to probe deeper regions of the sample, several microns below the surface. The same ion beam used to produce luminescence, can create a high density of defects, in a controllable way and the new set-up allows monitoring optical and electrical properties in realtime. In this work we combine IL with I-V curve measurements to assess the response of Ga{sub 2}O{sub 3} and GaN to proton irradiation. Ga{sub 2}O{sub 3} and GaN are emerging materials for applications in high power electronics and are considered for radiation resistant electronics. We will present a systematic study of the changes in IL and conductivity in Ga{sub 2}O{sub 3} and GaN samples with the energy of the ion beam and with the time of exposure. In particular, it was observed that during the irradiation some luminescence bands related with intrinsic point defects decrease while other new bands appear. Simulations using the SRIM code were used to determine the depth profiles of ionization and displacement events, helping to correlate the optical and electrical response of the materials with certain radiation effects. These studies show the potentialities of measuring simultaneously IL and electrical conductivity and how these two characterization techniques can work as a sensitive tool to detect and quantify radiation effects. (authors)

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Investigation on the structural and nonlinear optical properties of Pt doped TiO{sub 2} nanoparticles

Graphical abstract: The open aperture Z-scan traces of Pt doped TiO{sub 2} nanoparticles at different Pt concentrations were carried out at an irradiation wavelength of 532 nm. It was numerically found that, two photon absorption (TPA) type process gives the best fit to the obtained open aperture Z-scan data. The nonlinear transmission was found to be of third order as it fits to a two-photon absorption. The optical limiting performances of nanoparticles were greatly enhanced with increased volume ratio of Pt. Increasing particle size reduced the limiting threshold and enhanced the optical limiting performance. - Highlights: • Pt doped TiO{sub 2} nanoparticles with different concentrations of Pt have been synthesized by sol–gel method. • The average fluorescence lifetime decreases as the volume fraction of Pt dopant increases. • The effects of Pt content on the optical limiting property were investigated by open aperture Z-scan measurements done at 532 nm using 5 ns laser pulses. • The values of the third-order nonlinearities of nanoparticles are interesting from the application point of view which could be used as a potential candidate for the application of nonlinear optical device. - Abstract: Pt doped TiO{sub 2} nanoparticles with different concentrations of Pt were prepared by sol–gel method. X-ray diffraction (XRD) study reveals that the samples have a homogeneous anatase phase tetragonal system and the lattice parameter analysis indicates that Pt ions substitute into the lattice of TiO{sub 2}. The addition of dopant increases the growth of TiO{sub 2} grains, agglomerates them and shifts the absorption band of TiO{sub 2} from ultraviolet to visible region. The incorporation of Pt in TiO{sub 2} is also confirmed by fluorescence quenching and the fluorescence lifetime decreases as the volume fraction of Pt dopant increases. Open aperture Z-scan measurements done at 532 nm using 7 ns laser pulses show nonlinear absorption which arises from an effective two photon absorption process. The nonlinear optical properties are characterized by using fluence dependent transmittance measurements in order to reveal the optical limiting effects. It is found that the optical limiting performances of nanoparticles were greatly enhanced with increased concentration of Pt.

36 MATERIALS SCIENCE↗

Feedback-Controlled LED Photobioreactor for Photophysiological Studies of Cyanobacteria

A custom photobioreactor (PBR) was designed to enable automatic light adjustments using computerized feedback control. A black anodized aluminum enclosure, constructed to surround the borosilicate reactor vessel, prevents the transmission of ambient light and serves as a mount for arrays of light-emitting diodes (LEDs). The high-output LEDs provide narrow-band light of either 630 or 680 nm for preferential excitation of the cyanobacterial light-harvesting pigments, phycobilin or chlorophyll a, respectively. Custom developed software BioLume provides automatic control of optical properties and a computer feedback loop can automatically adjust the incident irradiance as necessary to maintain a fixed transmitted light through the culture, based on user-determined set points. This feedback control serves to compensate for culture dynamics which have optical effects, (e.g., changing cell density, pigment adaptations) and thus can determine the appropriate light conditions for physiological comparisons or to cultivate light-sensitive strains, without prior analyses. The LED PBR may also be controlled as a turbidostat, using a feedback loop to continuously adjust the rate of media-dilution based on the transmitted light measurements, with a fast and precise response. This cultivation system gains further merit as a high-performance analytical device, using non-invasive tools (e.g., dissolved gas sensors, online mass spectrometry) to automate real-time measurements, thus permitting unsupervised experiments to search for optimal growth conditions, to monitor physiological responses to perturbations, as well as to quantitate photophysiological parameters using an in situ light-saturation response routine.

controlled cultivation↗

Optimizing energy yield of monolithic perovskite/silicon tandem solar cells in real-world Conditions: The impact of luminescent coupling

Efficient light management is key to maximizing power conversion efficiency (PCE) in monolithic perovskite/silicon tandem solar cells. Achieving peak efficiency requires closely matched current generation in all junctions, especially in integrated configurations. However, real-world conditions vary significantly due to factors such as sunlight spectrum, diffuse-to-direct sunlight ratio, angular distribution of light, subcell temperature coefficients, and ground reflection. This study introduces a comprehensive optical and device simulation to optimize perovskite/silicon tandem cells, considering experimental luminescent coupling (LC) efficiency and its dependence on working conditions, alongside variations in radiative recombination, effect of temperature on absorptivity spectra, and cloud cover. Our results show potential energy yield improvements of up to 1.4 % with LC, based on current perovskite radiative recombination records, and up to 4 % with direct bandgap materials. Although radiative recombination's dependence on excitation intensity reduces output power and requires thicker absorbers, LC compensates for these losses. LC also lowers the optimized bandgap for the perovskite top cell from 1.72 eV to 1.64–1.68 eV, or even lower in regions with redshifted irradiance. Additionally, optimization revealed that thinner silicon bottom cells require a higher perovskite top cell bandgap, impacting the balance between fabrication cost and cell stability.

14 SOLAR ENERGY↗

Contactless measurement of the photovoltage in BiVO 4 photoelectrodes

The power output of photoelectrochemical devices for solar energy-to-fuel conversion is determined by the photovoltage of the junction under illumination. In the presence of fast redox couples, the photovoltage can be obtained directly from current–voltage measurements of the device. However, for slow redox couples (H + /H 2 , O 2 /H 2 O) used in solar fuel photoelectrodes, photovoltage measurements are not straightforward, due to the kinetic overpotentials during charge transfer. Here we show that the photovoltage of BiVO 4 electrodes in contact with fast electron donors KI, Na 2 SO 3 or H 2 O 2 or K 4 Fe(CN) 6 can be measured in a contactless way with vibrating Kelvin probe surface photovoltage (SPV) spectroscopy. The photovoltage varies with illumination wavelength and intensity and matches the open circuit potential of the electrodes, obtained separately from electrochemical measurements. Plots of the photovoltage versus irradiance can be used to predict the oxidizing power of each electrode under zero applied bias. Except for K 4 Fe(CN) 6 , which causes shunting in the BiVO 4 electrode, photovoltage values correlate well with the built-in potential of each junction. Furthermore, the ability to obtain photovoltage information through contactless SPV measurements will be useful in the search for solid–liquid junctions with superior energy conversion properties.

14 SOLAR ENERGY↗

Analytic band-to-trap tunneling model including band offset for heterojunction devices

In this paper, we present an analytic band-to-trap tunneling model based on the open boundary scattering approach. The new model has three major advantages: (i) It includes not only the well-known electric field effect, but more importantly, the effect of heterojunction band offset. This feature allows us to simulate both electric field and band offset enhanced carrier recombination near a heterojunction in heterostructures. (ii) Its analytic form enables straightforward implementation into a parallel Technology Computer Aided Design device and circuit simulators. (iii) The developed method can be used for any potentials which can be approximated to a good degree such that the Schrödinger equation with open boundary conditions results in piecewise analytic wave functions. Simulation results of an InGaP/GaAs heterojunction bipolar transistor (HBT) reveal that the proposed model predicts significantly increased base currents, because the tunneling of holes in the base to traps in the emitter is greatly enhanced by the emitter-base band offset. Lastly, this finding, which is not captured by existing band-to-trap tunneling models, is consistent with the experimental observation for an InGaP/GaAs HBT after neutron irradiation.

36 MATERIALS SCIENCE↗

SU-E-T-178: Experimental Study of Acceptable Movement Conditions for SBRT Lung Treatments

Purpose: To experimentally study the acceptable movement conditions for SBRT lung treatments we quantified with film dosimetry the change in dose distributions due to periodic movements of 5 different amplitudes and 4 respiratory gating duty cycles on a SBRT treatment plan. Methods: We planned a SBRT treatment plan for the QUASAR™ (Modus Medical) phantom equipped with the respiratory motion device. We placed a 3 mm water-equivalent sphere simulating a tumour inside the lung-equivalent insert. This sphere is divided in two hemispheres that allow placing films in between. We used radiochromic EBT2™ (Ashland) films. We oriented the lung insert in such a way that sagittal dose distributions could be measured. We applied a sinusoidal movement with 3 s period for 5 different amplitudes of 0(static), 5, 7, 10, 15 and 20 mm without gating. For the 20 mm amplitude we studied the gating technique with 4 duty cycles of 20, 40, 60 and 80% of the respiratory cycle. Each situation was irradiated in a Clinac 2100 linac (Varian) equipped with the RPM™ system. FilmQA Pro™ (Ashland) software together with an Expression 10000XL scanner (EPSON) were used to analyze and compare the measured dose distributions with those planned by the Eclipse™ TPS v. 8.9 (Varian) by means of gamma analysis with 6 criteria: 5%/3mm, 5%/2mm, 5%/1mm, 3%/3mm, 3%/2mm and 2%/2mm (threshold of 10%). Results: Movements with amplitude of less than 7mm do not significantly modified the dosimetry. Gating duty cycles of less than 40% yielded also acceptable results for a 2 cm amplitude movement. Conclusion: To safely perform daily accurate SBRT treatments, movements have to be restricted to 7 mm amplitude (±3.5 mm). Otherwise, a gating strategy should be considered.

60 APPLIED LIFE SCIENCES↗

Large-scale synthesis of Lu{sub 2}O{sub 3}:Ln{sup 3+} (Ln{sup 3+} = Eu{sup 3+}, Tb{sup 3+}, Yb{sup 3+}/Er{sup 3+}, Yb{sup 3+}/Tm{sup 3+}, and Yb{sup 3+}/Ho{sup 3+}) microspheres and their photoluminescence properties

Graphical abstract: In this work, multicolor and monodisperse Lu{sub 2}O{sub 3}:Ln{sup 3+} (Ln{sup 3+} = Eu{sup 3+}, Tb{sup 3+}, Yb{sup 3+}/Er{sup 3+}, Yb{sup 3+}/Tm{sup 3+}, and Yb{sup 3+}/Ho{sup 3+}) microspheres were prepared by a homogeneous precipitation method followed by a subsequent calcination process. Display Omitted Highlights: ► Lu{sub 2}O{sub 3}:Ln{sup 3+} microspheres were prepared by a precipitation followed by a calcination process. ► Lu{sub 2}O{sub 3}:Eu{sup 3+}/Tb{sup 3+} samples exhibit respective red or green emissions. ► Lu{sub 2}O{sub 3}:Yb{sup 3+}/Er{sup 3+}/Tm{sup 3+}/Ho{sup 3+} exhibit emissions of green, blue, yellow-green, respectively. ► These finding may find potential applications in bioanalysis and field emission displays. -- Abstract: In this work, multicolor and monodisperse Lu{sub 2}O{sub 3}:Ln{sup 3+} (Ln{sup 3+} = Eu{sup 3+}, Tb{sup 3+}, Yb{sup 3+}/Er{sup 3+}, Yb{sup 3+}/Tm{sup 3+}, and Yb{sup 3+}/Ho{sup 3+}) microspheres were prepared by a homogeneous precipitation method followed by a subsequent calcination process. X-ray diffraction (XRD), Fourier transformed infrared (FT-IR), thermogravimetric analysis (TGA), scanning electron microscopy (SEM), transmission electron microscopy (TEM), photoluminescence (PL) spectra, and cathodoluminescence (CL) spectra were employed to characterize the samples. Upon ultraviolet and low-voltage electron beams excitation, Lu{sub 2}O{sub 3}:Ln{sup 3+} (Ln{sup 3+} = Eu{sup 3+} and Tb{sup 3+}) samples exhibit respective bright red (Eu{sup 3+}, {sup 5}D{sub 0} → {sup 7}F{sub 2}) and green (Tb{sup 3+}, {sup 5}D{sub 4} → {sup 7}F{sub 5}) down-conversion (DC) emissions. Under 980 nm NIR irradiation, Lu{sub 2}O{sub 3}:Ln{sup 3+} (Ln{sup 3+} = Yb{sup 3+}/Er{sup 3+}, Yb{sup 3+}/Tm{sup 3+}, and Yb{sup 3+}/Ho{sup 3+}) exhibit characteristic up-conversion (UC) emissions of green (Er{sup 3+}, {sup 4}S{sub 3/2}, {sup 2}H{sub 11/2} → {sup 4}I{sub 15/2}), blue (Tm{sup 3+}, {sup 1}G{sub 4} → {sup 3}H{sub 6}) and yellow-green (Ho{sup 3+}, {sup 5}F{sub 4}, {sup 5}S{sub 2} → {sup 5}I{sub 8}), respectively. These finding may find potential applications in bioanalysis, optoelectronic and nanoscale devices, field emission displays, and so on.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Variable magnetic field electron spectrometer to measure hot electrons in the range of 50–460 keV

Resonance absorption (RA) occurs when a p-polarized electromagnetic wave, obliquely incident on an inhomogeneous plasma, tunnels past its turning point and resonantly excites an electron plasma wave (EPW) at the critical density. This phenomenon is important, for instance, in the direct drive approach to inertial fusion energy and is a particular example of a wider phenomenon in plasma physics known as mode conversion, which is crucial for heating magnetic fusion devices, such as tokamaks, via RF heating. Direct measurement of these RA-generated EPW accelerated hot electrons, with energy in the range of a few tens to a few hundreds of keV, is a challenging task due to the relatively low deflecting magnetic fields needed. The solution described here is a magnetic electron spectrometer (MES) with a continually changing magnetic field, lower at the entrance of the MES and gradually increasing toward the end, that enables the measurement of a wide spectral range of electrons with energies between 50 and 460 keV. Electron spectra taken in a LaserNetUS RA experiment were acquired from plasmas generated by irradiating polymer targets with the combination of an ~300 ps pulse followed by a series of ten high intensity 50–200 fs duration laser pulses from the ALEPH laser at Colorado State University. In conclusion, the high intensity beam is designed as spike trains of uneven duration and delay pulses in order to modify the RA phenomenon.

47 OTHER INSTRUMENTATION↗

Formation of conductive copper lines by femtosecond laser irradiation of copper nitride film on plastic substrates

In this paper, we report a simple method to form conductive copper lines by scanning a single-beam femtosecond pulse laser on a plastic substrate covered with copper nitride (Cu{sub 3}N) film. The Cu{sub 3}N films were prepared by DC magnetron sputtering in the presence of an Ar + N{sub 2} atmosphere at 100 °C. The influence of the laser power and scanning speed on the formed copper line width, surface features, and morphology was analyzed by means of optical microscopy, X-ray diffraction, non-contact 3D profilometer, and scanning electron microscopy. The experimental results demonstrate that low laser power and low scanning speed favor the formation of uniform and flat Cu lines. After process optimization, copper lines with a width less than 5 μm were obtained, which provides an attractive application prospect in the field of flexible electronic devices.

36 MATERIALS SCIENCE↗

Optical eye tracking system for real-time noninvasive tumor localization in external beam radiotherapy

Purpose: External beam radiotherapy currently represents an important therapeutic strategy for the treatment of intraocular tumors. Accurate target localization and efficient compensation of involuntary eye movements are crucial to avoid deviations in dose distribution with respect to the treatment plan. This paper describes an eye tracking system (ETS) based on noninvasive infrared video imaging. The system was designed for capturing the tridimensional (3D) ocular motion and provides an on-line estimation of intraocular lesions position based on a priori knowledge coming from volumetric imaging. Methods: Eye tracking is performed by localizing cornea and pupil centers on stereo images captured by two calibrated video cameras, exploiting eye reflections produced by infrared illumination. Additionally, torsional eye movements are detected by template matching in the iris region of eye images. This information allows estimating the 3D position and orientation of the eye by means of an eye local reference system. By combining ETS measurements with volumetric imaging for treatment planning [computed tomography (CT) and magnetic resonance (MR)], one is able to map the position of the lesion to be treated in local eye coordinates, thus enabling real-time tumor referencing during treatment setup and irradiation. Experimental tests on an eye phantom and seven healthy subjects were performed to assess ETS tracking accuracy. Results: Measurements on phantom showed an overall median accuracy within 0.16 mm and 0.40° for translations and rotations, respectively. Torsional movements were affected by 0.28° median uncertainty. On healthy subjects, the gaze direction error ranged between 0.19° and 0.82° at a median working distance of 29 cm. The median processing time of the eye tracking algorithm was 18.60 ms, thus allowing eye monitoring up to 50 Hz. Conclusions: A noninvasive ETS prototype was designed to perform real-time target localization and eye movement monitoring during ocular radiotherapy treatments. The device aims at improving state-of-the-art invasive procedures based on surgical implantation of radiopaque clips and repeated acquisition of X-ray images, with expected positive effects on treatment quality and patient outcome.

60 APPLIED LIFE SCIENCES↗

Wireless and chip-less passive radiation sensors for high dose monitoring

The safety of nuclear infrastructures may involve the monitoring of many parameters in harsh environments (high radiation level, high temperature, high pressure,..). If technological solutions exist for transducers part in such environments, the electronic part used in reader is not appropriate and still a challenging task. Well-known solutions to remove the electronic part from the harsh environment consist of connecting the transducer and the reader by long electrical wires or performing ex situ remote sensing. However wires may practically be difficult to implement while ex situ measurements are not compatible with on line monitoring. Wireless and passive sensors working in harsh environments could be an appropriate solution for the remote sensing of critical parameters. Passive sensors without electronics in the sensing unit are available (e.g., SAW sensors) but they suffer from short reading range (typically lower than 10 meters). In order to overcome this range limitation a new class of electromagnetic transducers was developed in the mid-2000's. The operating principle is based on the modification of the properties of high-frequency (>> 1 GHz) passive electromagnetic devices by the quantity to be measured. Based on this principle a wide range of sensing properties can be addressed and a large number of materials can be chosen. Moreover the use of high frequency allows reducing the size of the sensor elements (antenna, transducer) and enhancing the immunity to multi-path. Several principles of RF transducers have been already validated by LAAS-CNRS (e;g; pressure, temperature, stress) as well as radar-based solution for the wireless long-range sensors interrogation. The sensor dosimeter exploit here the known property of Hydrogen-Pressure Dosimeters (HPD) for which the polymer material dehydrogenates under nuclear irradiation. The transducer principle is described. The irradiation will generate the out-gazing (hydrogen) of the polymer inside a micro-chamber. The resulting overpressure leads to the deflection of a silicon membrane which modifies the resonant frequency of the RF resonator. Tests structures have been designed in order to quantify the HDPE out-gazing inside a micro-cavity by measuring the deflection of a boss silicon membrane with a mechanical profiler. A specific set up using interferometry method has been also developed to evaluate the pressure generated inside the micro-cavity. The procedure consists in applying a pressure that pushes the membrane to recover a flat membrane. This condition is monitored thanks to the extinction of the Newton rings. Irradiations have been performed up to 30 kGy using 6 MeV focused e-beam providing by electron accelerator. Membrane deflection and generated pressure around 0.2 μm/mg{sub HDPE}/kGy and 70 mbar/mg{sub HDPE}/kGy has been obtained for a 70 μm thick membrane. In order to characterize the hermetic sealing of the micro-chamber under hydrogen over-pressure, membrane deflection after irradiation has been recorded during 50 days. The variations of membrane deflection are randomly distributed and generally lower than ±5%, showing a good hermeticity during this period. (authors)

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Comparative analysis of LWR and FBR spent fuels for nuclear forensics evaluation

Some interesting issues are attributed to nuclide compositions of spent fuels from thermal reactors as well as fast reactors such as a potential to reuse as recycled fuel, and a possible capability to be manage as a fuel for destructive devices. In addition, analysis on nuclear forensics which is related to spent fuel compositions becomes one of the interesting topics to evaluate the origin and the composition of spent fuels from the spent fuel foot-prints. Spent fuel compositions of different fuel types give some typical spent fuel foot prints and can be estimated the origin of source of those spent fuel compositions. Some technics or methods have been developing based on some science and technological capability including experimental and modeling or theoretical aspects of analyses. Some foot-print of nuclear forensics will identify the typical information of spent fuel compositions such as enrichment information, burnup or irradiation time, reactor types as well as the cooling time which is related to the age of spent fuels. This paper intends to evaluate the typical spent fuel compositions of light water (LWR) and fast breeder reactors (FBR) from the view point of some foot prints of nuclear forensics. An established depletion code of ORIGEN is adopted to analyze LWR spent fuel (SF) for several burnup constants and decay times. For analyzing some spent fuel compositions of FBR, some coupling codes such as SLAROM code, JOINT and CITATION codes including JFS-3-J-3.2R as nuclear data library have been adopted. Enriched U-235 fuel composition of oxide type is used for fresh fuel of LWR and a mixed oxide fuel (MOX) for FBR fresh fuel. Those MOX fuels of FBR come from the spent fuels of LWR. Some typical spent fuels from both LWR and FBR will be compared to distinguish some typical foot-prints of SF based on nuclear forensic analysis.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Femtosecond laser-induced crystallization of amorphous N-doped Ge{sub 8}Sb{sub 92} films and in situ characterization by coherent phonon spectroscopy

Femtosecond laser-irradiation-induced phase change of amorphous N-doped Ge{sub 8}Sb{sub 92} films is in situ studied by coherent phonon spectroscopy. We have observed that a new coherent optical phonon (COP) mode occurs as laser irradiation fluence reaches certain thresholds, indicating laser-induced phase changes. Additionally, this new phonon mode has also been verified in heat-annealing-crystallized N-doped Ge{sub 8}Sb{sub 92} films, confirming the emergence of laser-irradiation-induced crystallization. By measuring the pump fluence dependence of COP dynamics in laser-crystallized N-doped Ge{sub 8}Sb{sub 92} films, we found that the frequency and lifetime of COP decrease with the increasing of pump fluence, which suggests good crystallinity in laser-crystallized N-doped Ge{sub 8}Sb{sub 92} films. It has also been observed that the crystallization temperature of amorphous N-doped Ge{sub 8}Sb{sub 92} films increases with N-doping content. Our results indicate promising applications of N-doped Ge{sub 8}Sb{sub 92} films in optical phase-change memory devices.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Photoinduced Nonequilibrium Topological States in Strained Black Phosphorus

Black phosphorus (BP), an elemental semiconductor, has attracted tremendous interest because it exhibits a wealth of interesting electronic and optoelectronic properties in equilibrium condition. The nonequilibrium electronic structures of bulk BP under a periodic field of laser remain unexplored, but can lead to intriguing topological optoelectronic properties. Here we show that, under the irradiation of circularly polarized light (CPL), BP exhibits a photon-dressed Floquet-Dirac semimetal state, which can be continuously tuned by changing the direction, intensity, and frequency of the incident laser. The topological phase transition from type-I to type-II Floquet-Dirac fermions manifests a new form of type-III phase, which exists in a wide range of intensities and frequencies of the incident laser. Furthermore, topological surface states exhibit nonequilibrium electron transport in a direction locked by the helicity of CPL. Our findings not only deepen our understanding of fundamental properties of BP in relation to topology but also extend optoelectronic device applications of BP to the nonequilibrium regime.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗