Implications of CT noise and artifacts for quantitative {sup 99m}Tc SPECT/CT imaging

Purpose: This paper evaluates the effects of computed tomography (CT) image noise and artifacts on quantitative single-photon emission computed-tomography (SPECT) imaging, with the aim of establishing an appropriate range of CT acquisition parameters for low-dose protocols with respect to accurate SPECT attenuation correction (AC). Methods: SPECT images of two geometric and one anthropomorphic phantom were reconstructed iteratively using CT scans acquired at a range of dose levels (CTDI{sub vol} = 0.4 to 46 mGy). Resultant SPECT image quality was evaluated by comparing mean signal, background noise, and artifacts to SPECT images reconstructed using the highest dose CT for AC. Noise injection was performed on linear-attenuation (μ) maps to determine the CT noise threshold for accurate AC. Results: High levels of CT noise (σ ∼ 200–400 HU) resulted in low μ-maps noise (σ ∼ 1%–3%). Noise levels greater than ∼10% in 140 keV μ-maps were required to produce visibly perceptible increases of ∼15% in {sup 99m}Tc SPECT images. These noise levels would be achieved at low CT dose levels (CTDI{sub vol} = 4 μGy) that are over 2 orders of magnitude lower than the minimum dose for diagnostic CT scanners. CT noise could also lower (bias) the expected μ values. The relative error in reconstructed SPECT signal trended linearly with the relative shift in μ. SPECT signal was, on average, underestimated in regions corresponding with beam-hardening artifacts in CT images. Any process that has the potential to change the CT number of a region by ∼100 HU (e.g., misregistration between CT images and SPECT images due to motion, the presence of contrast in CT images) could introduce errors in μ{sub 140} {sub keV} on the order of 10%, that in turn, could introduce errors on the order of ∼10% into the reconstructed {sup 99m}Tc SPECT image. Conclusions: The impact of CT noise on SPECT noise was demonstrated to be negligible for clinically achievable CT parameters. Because CT dose levels that affect SPECT quantification is low (CTDI{sub vol} ∼ 4 μGy), the low dose limit for the CT exam as part of SPECT/CT will be guided by CT image quality requirements for anatomical localization and artifact reduction. A CT technique with higher kVp in combination with lower mAs is recommended when low-dose CT images are used for AC to minimize beam-hardening artifacts.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Automatic information extraction from neutron radiography imaging to estimate axial fuel expansion in $\mathrm{EBR-II}$

Approximately 130,000 metal fuel pins were irradiated in the Experimental Breeder Reactor II (EBR-II) during its 30 years of operation to develop and characterize existing and prospective fuels. For many of the metal fuel irradiation experiments, neutron radiography imaging was performed to characterize fuel behavior, like fuel swelling. However, due to the lack of technology or resources, many of the images have not been processed or were processed manually through visual examination. This paper represents first-attempt to develop an image processing algorithm capable of automatically extracting information regarding the degree of fuel swelling from neutron radiography imaging. The algorithm was applied to 120 images of three different metallic fuel pin compositions—U-10Zr, U-8Pu-10Zr, and U-19Pu-10Zr. The algorithm performs operations of image intensity adjustment, image binarization, region finding, and labeling to extract information about fuel swelling. The average growth for U-10Zr was found to be 8.49% with 95% Confidence Interval (CI) [8.33 –8.66%], for U-8Pu-10Zr — 7.50% with 95% CI [7.23 – 7.78%], and for U-19Pu-10Zr — 3.15%, with 95% CI [2.40 – 3.91%]. The results obtained by applying this automatic image processing algorithm are consistent with previously reported studies of the same types of fuels. The automatic image processing algorithm will be expanded to include thousands of available neutron radiography images and different types of fuels to investigate empirical dependencies of fuel swelling, which can be subsequently applied to advanced fuel modeling. Results from this study can later be compared to BISON simulations to further benchmark modeling efforts and develop assessment cases.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

SU-F-P-48: The Quantitative Evaluation and Comparison of Image Distortion and Loss of X-Ray Images Between Anti-Scattered Grid and Moire Compensation Processing in Digital Radiography

Purpose: To quantitatively analyze the influence image processing for Moire elimination has in digital radiography by comparing the image acquired from optimized anti-scattered grid only and the image acquired from software processing paired with misaligned low-frequency grid. Methods: Special phantom, which does not create scattered radiation, was used to acquire non-grid reference images and they were acquired without any grids. A set of images was acquired with optimized grid, aligned to pixel of a detector and other set of images was acquired with misaligned low-frequency grid paired with Moire elimination processing algorithm. X-ray technique used was based on consideration to Bucky factor derived from non-grid reference images. For evaluation, we analyze by comparing pixel intensity of acquired images with grids to that of reference images. Results: When compared to image acquired with optimized grid, images acquired with Moire elimination processing algorithm showed 10 to 50% lower mean contrast value of ROI. Severe distortion of images was found with when the object’s thickness was measured at 7 or less pixels. In this case, contrast value measured from images acquired with Moire elimination processing algorithm was under 30% of that taken from reference image. Conclusion: This study shows the potential risk of Moire compensation images in diagnosis. Images acquired with misaligned low-frequency grid results in Moire noise and Moire compensation processing algorithm used to remove this Moire noise actually caused an image distortion. As a result, fractures and/or calcifications which are presented in few pixels only may not be diagnosed properly. In future work, we plan to evaluate the images acquired without grid but based on 100% image processing and the potential risks it possesses.

60 APPLIED LIFE SCIENCES↗

In Search of Optimum Fresh-Cut Raw Material: Using Computer Vision Systems as a Sensory Screening Tool for Browning-Resistant Romaine Lettuce Accessions

The popularity of ready-to-eat (RTE) salads has prompted novel technology to prolong the shelf life of their ingredients. Fresh-cut romaine lettuce is widely used in RTE salads; however, its tendency to quickly discolor continues to be a challenge for the industry. Selecting the ideal lettuce accessions for use in RTE salads is essential to ensure maximum shelf life, and it is critical to have a practical way to assess and compare the quality of multiple lettuce accessions that are being considered for use in fresh-cut applications. Thus, in this work we aimed to determine whether a computer vision system (CVS) composed of image acquisition, processing, and analysis could be effective to detect visual quality differences among 16 accessions of fresh-cut romaine lettuce during postharvest storage. The CVS involved a post-capturing color correction, effective image segmentation, and calculation of a browning index, which was tested as a predictor of quality and shelf life of fresh-cut romaine lettuce. The results demonstrated that machine vision software can be implemented to replace or supplement the scoring of a trained panel and instrumental quality measurements. Overall visual quality, a key sensory parameter that determines food preferences and consumer behavior, was highly correlated with the browning index, with a Pearson correlation coefficient of −0.85. Other important sensory decision parameters were also strongly or moderately correlated with the browning index, with Pearson correlation coefficients of −0.84 for freshness, 0.79 for off odor, and 0.57 for browning. The ranking of the accessions according to quality acceptability from the sensory evaluation produced a similar pattern to those obtained with the CVS. This study revealed that multiple lettuce accessions can be effectively benchmarked for their performance as fresh-cut sources via a CVS-based method. Future opportunities and challenges in using machine vision image processing to predict consumer preferences for RTE salad greens is also discussed.

Agriculture↗

SU-G-BRA-01: A Real-Time Tumor Localization and Guidance Platform for Radiotherapy Using US and MRI

Purpose: To develop and validate a real-time motion management platform for radiotherapy that directly tracks tumor motion using ultrasound and MRI. This will be a cost-effective and non-invasive real-time platform combining the excellent temporal resolution of ultrasound with the excellent soft-tissue contrast of MRI. Methods: A 4D planar ultrasound acquisition during the treatment that is coupled to a pre-treatment calibration training image set consisting of a simultaneous 4D ultrasound and 4D MRI acquisition. The image sets will be rapidly matched using advanced image and signal processing algorithms, allowing the display of virtual MR images of the tumor/organ motion in real-time from an ultrasound acquisition. Results: The completion of this work will result in several innovations including: a (2D) patch-like, MR and LINAC compatible 4D planar ultrasound transducer that is electronically steerable for hands-free operation to provide real-time virtual MR and ultrasound imaging for motion management during radiation therapy; a multi- modal tumor localization strategy that uses ultrasound and MRI; and fast and accurate image processing algorithms that provide real-time information about the motion and location of tumor or related soft-tissue structures within the patient. Conclusion: If successful, the proposed approach will provide real-time guidance for radiation therapy without degrading image or treatment plan quality. The approach would be equally suitable for image-guided proton beam or heavy ion-beam therapy. This work is partially funded by NIH grant R01CA190298.

60 APPLIED LIFE SCIENCES↗

Automated imaging system for single molecules

There is provided a high throughput automated single molecule image collection and processing system that requires minimal initial user input. The unique features embodied in the present disclosure allow automated collection and initial processing of optical images of single molecules and their assemblies. Correct focus may be automatically maintained while images are collected. Uneven illumination in fluorescence microscopy is accounted for, and an overall robust imaging operation is provided yielding individual images prepared for further processing in external systems. Embodiments described herein are useful in studies of any macromolecules such as DNA, RNA, peptides and proteins. The automated image collection and processing system and method of same may be implemented and deployed over a computer network, and may be ergonomically optimized to facilitate user interaction.

47 OTHER INSTRUMENTATION↗

Full-Depth Coadds of the WISE and First-Year NEOWISE-Reactivation Images

The Near Earth Object Wide-field Infrared Survey Explorer (NEOWISE) Reactivation mission released data from its first full year of observations in 2015. This data set includes ~2.5 million exposures in each of W1 and W2, effectively doubling the amount of WISE imaging available at 3.4 μm and 4.6 μm relative to the AllWISE release. In this paper, we have created the first ever full-sky set of coadds combining all publicly available W1 and W2 exposures from both the AllWISE and NEOWISE-Reactivation (NEOWISER) mission phases. We employ an adaptation of the unWISE image coaddition framework, which preserves the native WISE angular resolution and is optimized for forced photometry. By incorporating two additional scans of the entire sky, we not only improve the W1/W2 depths, but also largely eliminate time-dependent artifacts such as off-axis scattered moonlight. We anticipate that our new coadds will have a broad range of applications, including target selection for upcoming spectroscopic cosmology surveys, identification of distant/massive galaxy clusters, and discovery of high-redshift quasars. In particular, our full-depth AllWISE+NEOWISER coadds will be an important input for the Dark Energy Spectroscopic Instrument selection of luminous red galaxy and quasar targets. Our full-depth W1/W2 coadds are already in use within the DECam Legacy Survey (DECaLS) and Mayall z-band Legacy Survey (MzLS) reduction pipelines. Finally, much more work still remains in order to fully leverage NEOWISER imaging for astrophysical applications beyond the solar system.

79 ASTRONOMY AND ASTROPHYSICS↗

A DARK ENERGY CAMERA SEARCH FOR AN OPTICAL COUNTERPART TO THE FIRST ADVANCED LIGO GRAVITATIONAL WAVE EVENT GW150914

We report the results of a deep search for an optical counterpart to the gravitational wave (GW) event GW150914, the first trigger from the Advanced LIGO GW detectors. We used the Dark Energy Camera (DECam) to image a 102 deg{sup 2} area, corresponding to 38% of the initial trigger high-probability sky region and to 11% of the revised high-probability region. We observed in the i and z bands at 4–5, 7, and 24 days after the trigger. The median 5 σ point-source limiting magnitudes of our search images are i = 22.5 and z = 21.8 mag. We processed the images through a difference-imaging pipeline using templates from pre-existing Dark Energy Survey data and publicly available DECam data. Due to missing template observations and other losses, our effective search area subtends 40 deg{sup 2}, corresponding to a 12% total probability in the initial map and 3% in the final map. In this area, we search for objects that decline significantly between days 4–5 and day 7, and are undetectable by day 24, finding none to typical magnitude limits of i = 21.5, 21.1, 20.1 for object colors ( i − z ) = 1, 0, −1, respectively. Our search demonstrates the feasibility of a dedicated search program with DECam and bodes well for future research in this emerging field.

79 ASTRONOMY AND ASTROPHYSICS↗

SU-E-J-90: MRI-Based Treatment Simulation and Patient Setup for Radiation Therapy of Brain Cancer

Purpose: Traditional radiation therapy of cancer is heavily dependent on CT. CT provides excellent depiction of the bones but lacks good soft tissue contrast, which makes contouring difficult. Often, MRIs are fused with CT to take advantage of its superior soft tissue contrast. Such an approach has drawbacks. It is desirable to perform treatment simulation entirely based on MRI. To achieve MR-based simulation for radiation therapy, bone imaging is an important challenge because of the low MR signal intensity from bone due to its ultra-short T2 and T1, which presents difficulty for both dose calculation and patient setup in terms of digitally reconstructed radiograph (DRR) generation. Current solutions will either require manual bone contouring or multiple MR scans. We present a technique to generate DRR using MRI with an Ultra Short Echo Time (UTE) sequence which is applicable to both OBI and ExacTrac 2D patient setup. Methods: Seven brain cancer patients were scanned at 1.5 Tesla using a radial UTE sequence. The sequence acquires two images at two different echo times. The two images were processed using in-house software. The resultant bone images were subsequently loaded into commercial systems to generate DRRs. Simulation and patient clinical on-board images were used to evaluate 2D patient setup with MRI-DRRs. Results: The majority bones are well visualized in all patients. The fused image of patient CT with the MR bone image demonstrates the accuracy of automatic bone identification using our technique. The generated DRR is of good quality. Accuracy of 2D patient setup by using MRI-DRR is comparable to CT-based 2D patient setup. Conclusion: This study shows the potential of DRR generation with single MR sequence. Further work will be needed on MR sequence development and post-processing procedure to achieve robust MR bone imaging for other human sites in addition to brain.

60 APPLIED LIFE SCIENCES↗

SU-F-R-20: Image Texture Features Correlate with Time to Local Failure in Lung SBRT Patients

Purpose: To explore possible correlation between CT image-based texture and histogram features and time-to-local-failure in early stage non-small cell lung cancer (NSCLC) patients treated with stereotactic body radiotherapy (SBRT).Methods and Materials: From an IRB-approved lung SBRT registry for patients treated between 2009–2013 we selected 48 (20 male, 28 female) patients with local failure. Median patient age was 72.3±10.3 years. Mean time to local failure was 15 ± 7.1 months. Physician-contoured gross tumor volumes (GTV) on the planning CT images were processed and 3D gray-level co-occurrence matrix (GLCM) based texture and histogram features were calculated in Matlab. Data were exported to R and a multiple linear regression model was used to examine the relationship between texture features and time-to-local-failure. Results: Multiple linear regression revealed that entropy (p=0.0233, multiple R2=0.60) from GLCM-based texture analysis and the standard deviation (p=0.0194, multiple R2=0.60) from the histogram-based features were statistically significantly correlated with the time-to-local-failure. Conclusion: Image-based texture analysis can be used to predict certain aspects of treatment outcomes of NSCLC patients treated with SBRT. We found entropy and standard deviation calculated for the GTV on the CT images displayed a statistically significant correlation with and time-to-local-failure in lung SBRT patients.

60 APPLIED LIFE SCIENCES↗

X-ray tomography system to investigate granular materials during mechanical loading

We integrate a small and portable medical x-ray device with mechanical testing equipment to enable in situ, non-invasive measurements of a granular material's response to mechanical loading. We employ an orthopedic C-arm as the x-ray source and detector to image samples mounted in the materials tester. We discuss the design of a custom rotation stage, which allows for sample rotation and tomographic reconstruction under applied compressive stress. We then discuss the calibration of the system for 3D computed tomography, as well as the subsequent image reconstruction process. Using this system to reconstruct packings of 3D-printed particles, we resolve packing features with 0.52 mm resolution in a (60 mm){sup 3} field of view. By analyzing the performance bounds of the system, we demonstrate that the reconstructions exhibit only moderate noise.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Texture analysis of placental MRI: can it aid in the prenatal diagnosis of placenta accreta spectrum?

Purpose: To determine if texture analysis can differentiate placenta accreta spectrum (PAS) from normal placenta on MRI. Methods: We performed retrospective image analysis of 80 patients, comprised of 46 patients with PAS and 34 patients without PAS. Histopathology was used as the reference standard. Sagittal single shot fast spin echo T2-weighted MRI sequences acquired from a single institution were analyzed. Placental heterogeneity was quantified using in-house software on a Matlab platform, including the standard deviation of pixel intensity, coefficient of variation, gray-level co-occurrence matrices (GLCM), histogram-oriented gradients (HOG), and fractal analysis with box sizes from 2 to 512. Two-tailed unpaired Student’s t test was used with statistical significance of p < 0.05. Results: PAS was associated with higher values for standard deviation of pixel intensity and fractal analysis at every box size. Fractal analysis at box sizes 256 (p = 0.011) and 32 (p = 0.021), and standard deviation of pixel intensity (p = 0.023) were the most statistically significant. Fractal values at box size 256 for PAS was 0.13 versus 0.090 for patients without PAS, while standard deviation of pixel intensity was 3.7 for PAS versus 2.5 for patients without PAS. No statistically significant association between PAS and GLCM, coefficient of variation, and HOG was found. Conclusion: Statistically significant differences were found between normal and abnormal groups using standard deviation of pixel intensity and fractal analysis.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Convolutional neural networks for intra-hour solar forecasting based on sky image sequences

Accurate and timely solar forecasts play an increasingly critical role in power systems. Compared to longer forecasting timescales, very short-term solar forecasting has lagged behind in both research and practice. In this paper, we propose deep convolutional neural networks (CNNs) to provide operational intra-hour (10-minute-ahead to 60-minute-ahead) solar forecasts. We develop two CNN structures inspired by a widely-used CNN architecture. The CNNs are tailored to our solar forecasting regression tasks and rely solely on sky image sequences. Case studies based on six years of data (over 150,000 data points) demonstrate that the best CNN model has forecast skill scores of 20%-39% over the naive persistence of cloudiness benchmark, even at these very short timescales. The CNNs also have consistently superior performance when compared to shallow machine learning models with meteorological predictors, where the improvement averages around 7%. The sensitivity analyses show that the sky image length, resolution, and weather conditions have impacts on the deep learning model accuracy. In our intra-hour problem with specific setups, two sky images with a 10-minute 128 x 128 resolution yield the most accurate forecasts. Current limitations, future work, and deployment challenges and solutions are also discussed.

14 SOLAR ENERGY↗

Characteristics of different frequency ranges in scanning electron microscope images

We demonstrate a new approach to characterize the frequency range in general scanning electron microscope (SEM) images. First, pure frequency images are generated from low frequency to high frequency, and then, the magnification of each type of frequency image is implemented. By comparing the edge percentage of the SEM image to the self-generated frequency images, we can define the frequency ranges of the SEM images. Characterization of frequency ranges of SEM images benefits further processing and analysis of those SEM images, such as in noise filtering and contrast enhancement.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

A knock-on deuteron imager for measurements of fuel and hotspot asymmetry in direct-drive inertial confinement fusion implosions (invited)

A knock-on deuteron imager (KoDI) has been implemented to measure the fuel and hotspot asymmetry of cryogenic inertial confinement fusion implosions on OMEGA. Energetic neutrons produced by D–T fusion elastically scatter (“knock on”) deuterons from the fuel layer with a probability that depends on ρR. Deuterons above 10 MeV are produced by near-forward scattering, and imaging them is equivalent to time-integrated neutron imaging of the hotspot. Deuterons below 6 MeV are produced by a combination of side scattering and ranging in the fuel, and encode information about the spatial distribution of the dense fuel. Here, the KoDI instrument consists of a multi-penumbral aperture positioned 10–20 cm from the implosion using a ten-inch manipulator and a detector pack at 350 cm from the implosion to record penumbral images with magnification of up to 35×. Range filters and the intrinsic properties of CR-39 are used to distinguish different charged-particle images by energy along the same line of sight. Image plates fielded behind the CR-39 record a 10 keV x-ray image using the same aperture. A maximum-likelihood reconstruction algorithm has been implemented to infer the source from the projected penumbral images. The effects of scattering and aperture charging on the instrument point-spread function are assessed. Synthetic data are used to validate the reconstruction algorithm and assess an appropriate termination criterion. Significant aperture charging has been observed in the initial experimental dataset, and increases with aperture distance from the implosion, consistent with a simple model of charging by laser-driven EMP.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Neutron imaging of inertial confinement fusion implosions

We review experimental neutron imaging of inertial confinement fusion sources, including the neutron imaging systems that have been used in our measurements at the National Ignition Facility. These systems allow measurements with 10 µm resolution for fusion deuterium–deuterium and deuterium–tritium neutron sources with mean radius up to 400 µm, including measurements of neutrons scattered to lower energy in the remaining cold fuel. These measurements are critical for understanding the fusion burn volume and the three-dimensional effects that can reduce the neutron yields.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Design optimization of MR-compatible rotating anode x-ray tubes for stable operation

Purpose: Hybrid x-ray/MR systems can enhance the diagnosis and treatment of endovascular, cardiac, and neurologic disorders by using the complementary advantages of both modalities for image guidance during interventional procedures. Conventional rotating anode x-ray tubes fail near an MR imaging system, since MR fringe fields create eddy currents in the metal rotor which cause a reduction in the rotation speed of the x-ray tube motor. A new x-ray tube motor prototype has been designed and built to be operated close to a magnet. To ensure the stability and safety of the motor operation, dynamic characteristics must be analyzed to identify possible modes of mechanical failure. In this study a 3D finite element method (FEM) model was developed in order to explore possible modifications, and to optimize the motor design. The FEM provides a valuable tool that permits testing and evaluation using numerical simulation instead of building multiple prototypes.Methods: Two experimental approaches were used to measure resonance characteristics: the first obtained the angular speed curves of the x-ray tube motor employing an angle encoder; the second measured the power spectrum using a spectrum analyzer, in which the large amplitude of peaks indicates large vibrations. An estimate of the bearing stiffness is required to generate an accurate FEM model of motor operation. This stiffness depends on both the bearing geometry and adjacent structures (e.g., the number of balls, clearances, preload, etc.) in an assembly, and is therefore unknown. This parameter was set by matching the FEM results to measurements carried out with the anode attached to the motor, and verified by comparing FEM predictions and measurements with the anode removed. The validated FEM model was then used to sweep through design parameters [bearing stiffness (1×10{sup 5}–5×10{sup 7} N/m), shaft diameter (0.372–0.625 in.), rotor diameter (2.4–2.9 in.), and total length of motor (5.66–7.36 in.)] to increase the fundamental frequency past the operating range at 50 Hz.Results: The first large vibration during the prototype motor operation was obtained at 21.64±0.68 Hz in the power spectrum. An abrupt decrease in acceleration occurred at 21.5 Hz due to struggling against the resonance vibrations. A bearing stiffness of 1.2×10{sup 5} N/m in the FEM simulation was used to obtain a critical speed of 21.4 Hz providing 1.1% error. This bearing stiffness value and the 3D model were then confirmed by the experiments with the anode removed, demonstrating an agreement within 6.4% between simulation results and measurements. A calculated first critical frequency (fundamental frequency) of 68.5 Hz was obtained by increasing the bearing stiffness to 1×10{sup 7} N/m and increasing the shaft diameter by 68.0%. Reducing the number of bearings in the design permits decreasing the total length of the motor by 1.7 in., and results in a fundamental frequency of 68.3 Hz in concert with additional changes (shaft diameter of 0.625 in., rotor diameter of 2.4 in., and bearing stiffness of 1×10{sup 6} N/m).Conclusions: An FEM model of the x-ray tube motor has been implemented and experimentally validated. A fundamental frequency above the operational rotation speed can be achieved through modification of multiple design parameters, which allows the motor to operate stably and safely in the MR environment during the repeated acceleration/deceleration cycles required for an interventional procedure. The validated 3D FEM model can now be used to investigate trade-offs between generated torque, maximum speed, and motor inertia to further optimize motor design.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Magnetoacoustic tomography with magnetic induction for high-resolution bioimepedance imaging through vector source reconstruction under the static field of MRI magnet

Purpose: Magnetoacoustic tomography with magnetic induction (MAT-MI) is an imaging modality to reconstruct the electrical conductivity of biological tissue based on the acoustic measurements of Lorentz force induced tissue vibration. This study presents the feasibility of the authors' new MAT-MI system and vector source imaging algorithm to perform a complete reconstruction of the conductivity distribution of real biological tissues with ultrasound spatial resolution. Methods: In the present study, using ultrasound beamformation, imaging point spread functions are designed to reconstruct the induced vector source in the object which is used to estimate the object conductivity distribution. Both numerical studies and phantom experiments are performed to demonstrate the merits of the proposed method. Also, through the numerical simulations, the full width half maximum of the imaging point spread function is calculated to estimate of the spatial resolution. The tissue phantom experiments are performed with a MAT-MI imaging system in the static field of a 9.4 T magnetic resonance imaging magnet. Results: The image reconstruction through vector beamformation in the numerical and experimental studies gives a reliable estimate of the conductivity distribution in the object with a ∼1.5 mm spatial resolution corresponding to the imaging system frequency of 500 kHz ultrasound. In addition, the experiment results suggest that MAT-MI under high static magnetic field environment is able to reconstruct images of tissue-mimicking gel phantoms and real tissue samples with reliable conductivity contrast. Conclusions: The results demonstrate that MAT-MI is able to image the electrical conductivity properties of biological tissues with better than 2 mm spatial resolution at 500 kHz, and the imaging with MAT-MI under a high static magnetic field environment is able to provide improved imaging contrast for biological tissue conductivity reconstruction.

62 RADIOLOGY AND NUCLEAR MEDICINE↗