Search NASA⌕ Search

SEARCH · Search NASA

Results for “Infrared techniques”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,423 records · Page 79

Circularly Polarized Attosecond Pulses Enabled by an Azimuthal Phase and Polarization Grating

High-harmonic generation (HHG) is an extreme nonlinear optical process that can map the properties of an infrared driving laser beam onto short wavelength attosecond pulse trains. However, current techniques for generating circularly polarized high harmonics for probing magnetic materials and chiral systems have limitations: two-color collinear counter-rotating driving lasers result in a low cutoff photon energy, while single-color non-collinear counter-rotating schemes suffer from low conversion efficiency. In this work, we generate circularly polarized attosecond pulse trains by using a structured laser driver which has a rotating polarization and phase grating along the azimuthal coordinate. Furthermore, our experimental and numerical results demonstrate the production of left and right circularly polarized harmonics, which naturally separate upon propagation. Our approach uses a single laser color in a collinear geometry, that can be scaled for high efficiency. Simulations show this scheme can extend into the soft x-ray region when driven by mid-infrared driving lasers, while preserving the same high phase-matching cutoff photon energy as for linearly-polarized high harmonics.

attosecond science↗

Photocurrent spectrum study of a quantum dot single-photon detector based on resonant tunneling effect with near-infrared response

We present the photocurrent spectrum study of a quantum dot (QD) single-photon detector using a reset technique which eliminates the QD's “memory effect.” By applying a proper reset frequency and keeping the detector in linear-response region, the detector's responses to different monochromatic light are resolved which reflects different detection efficiencies. We find the reset photocurrent tails up to 1.3 μm wavelength and near-infrared (∼1100 nm) single-photon sensitivity is demonstrated due to interband transition of electrons in QDs, indicating the device a promising candidate both in quantum information applications and highly sensitive imaging applications operating in relative high temperatures (>80 K).

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Structural and electrical characterizations of In{sub x}Ga{sub 1-x}As/InP structures for infrared photodetector applications

Three InGaAs/InP structures for photodetector applications were grown with different indium compositions by MBE technique. The structural properties of the samples have been obtained by means of high resolution X-ray diffraction and secondary ion mass spectrometry measurements. Three InGaAs/InP metal-semiconductor-metal devices were fabricated at room temperature. The experimental forward and reverse bias current–voltage characteristics of the devices such as ideality factor, barrier height, and saturation current were evaluated considering the structural properties of the grown structures. The carrier recombination lifetime and diffusion length in the devices were also calculated using carrier density and mobility data obtained with Hall effect measurement at room temperature. It was determined that all room temperature fabricated devices improved the Schottky barrier height. Especially, the device fabricated on the lower mismatched structure exhibited barrier height enhancement from 0.2 eV, which is the conventional barrier height to 0.642 eV. In addition, the obtained results show that the room temperature fabricated devices on InGaAs/InP structures can be convenient for infrared photodetector applications.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Enhanced Sea Ice Concentration and Ice Temperature Algorithms for AMSR

Accurate quantification of sea ice concentration and ice temperature from satellite passive microwave data is important because they provide the only long term, spatially detailed and consistent data set needed to study the climatology of the polar regions. Sea ice concentration data are used to derive large-scale daily ice extents that are utilized in trend analysis of the global sea ice cover. They are also used to quantify the amount of open water and thin ice in polynya and divergence regions which together with ice temperatures are in turn needed to estimate vertical heat and salinity fluxes in these regions. Sea ice concentrations have been derived from the NASA Team and Bootstrap algorithms while a separate technique for deriving ice temperature has been reported. An integrated technique that will utilizes most of the channels of AMSR (Advanced Microwave Scanning Radiometer) has been developed. The technique uses data from the 6 GHz and 37 GHz channels at vertical polarization obtain an initial estimate of sea ice concentration and ice temperature. The derived ice temperature is then utilized to estimate the emissivities for the corresponding observations at all the other channels. A procedure for calculating the ice concentration similar to the Bootstrap technique is then used but with variables being emissivities instead of brightness temperatures to minimizes errors associated with spatial changes in ice temperatures within the ice pack. Comparative studies of ice concentration results with those from other algorithms, including the original Bootstrap algorithm and those from high resolution satellite visible and infrared data will be presented. Also, results from a simulation study that demonstrates the effectiveness of the technique in correcting for spatial variations in ice temperatures will be shown. The ice temperature results are likewise compared with satellite infrared and buoy data with the latter adjusted to account for the effects of the snow cover.

Comiso, Josefino C.↗

Correlating Detergent Fiber Analysis and Dietary Fiber Analysis Data for Corn Stover

There exist large amounts of detergent fiber analysis data [neutral detergent fiber (NDF), acid detergent fiber (ADF), acid detergent lignin (ADL)] for many different potential cellulosic ethanol feedstocks, since these techniques are widely used for the analysis of forages. Researchers working in the area of cellulosic ethanol are interested in the structural carbohydrates in a feedstock (principally glucan and xylan), which are typically determined by acid hydrolysis of the structural fraction after multiple extractions of the biomass. These so-called dietary fiber analysis methods are significantly more involved than detergent fiber analysis methods. The purpose of this study was to determine whether it is feasible to correlate detergent fiber analysis values to glucan and xylan content determined by dietary fiber analysis methods for corn stover. In the detergent fiber analysis literature cellulose is often estimated as the difference between ADF and ADL, while hemicellulose is often estimated as the difference between NDF and ADF. Examination of a corn stover dataset containing both detergent fiber analysis data and dietary fiber analysis data predicted using near infrared spectroscopy shows that correlations between structural glucan measured using dietary fiber techniques and cellulose estimated using detergent techniques, and between structural xylan measured using dietary fiber techniques and hemicellulose estimated using detergent techniques are high, but are driven largely by the underlying correlation between total extractives measured by fiber analysis and NDF/ADF. That is, detergent analysis data is correlated to dietary fiber analysis data for structural carbohydrates, but only indirectly; the main correlation is between detergent analysis data and solvent extraction data produced during the dietary fiber analysis procedure.

09 BIOMASS FUELS↗

Developments in electronic imaging techniques; Proceedings of the Seminar-in-Depth, San Mateo, Calif., October 16, 17, 1972.

Capabilities and limitations of infrared imaging systems are discussed, and a real-time simulator for image data systems is described. Ultrahigh resolution electronic imaging and storage with the return beam vidicon is treated, and a description is given of an electron-lens for opaque photocathodes. Ground surveillance with an active low light level TV, digital processing of Mariner 9 TV data, image enhancement by holography, and application of data compression techniques to spacecraft imaging systems are given attention. Individual items are announced in this issue.

Zirkind, R.↗

Atomic and molecular phases through attosecond streaking

In attosecond streaking, an electron is released by a short xuv pulse into a strong near infrared laser field. If the laser couples two states in the target, the streaking technique, which allows for a complete determination of the driving field, also gives an accurate measurement of the relative phase of the atomic or molecular ionization matrix elements from the two states through the interference from the two channels. The interference may change the phase of the photoelectron streaking signal within the envelope of the infrared field, an effect to be accounted for when reconstructing short pulses from the photoelectron signal and in attosecond time-resolved measurements.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

FTIR and Raman Spectroscopy of Reduced Graphene Oxide Carbon Nanoribbons and Graphene Oxide on Copper (Cu)

In the past couple of decades, carbon nanomaterials produced from graphene and graphite have emerged as one of the more important recently discovered substances. These carbon nanomaterials have been found to exhibit high levels of mechanical strength, thermal resistance, and electrical conductivity, thus having a multitude of applications. Therefore, it is important to identify and analyze their traits in order to maximize their effectiveness. Two spectroscopic techniques employed for such analyses of these materials are Fourier-Transform Infrared (FTIR) and Raman Spectroscopy. The advantages of FTIR and Raman include nondestructive analysis, relatively quick measurements under normal atmospheric conditions, and enhanced sensitivity with high resolution capacity. FTIR Spectroscopy was used in this research project to determine the effects of thermal exfoliation and photoreduction on the functionality groups of a carbon nanomaterial. Raman Spectroscopy was used in this research project to determine the effects of thermal exfoliation and photoreduction on the intensity of the disorder peak, which is greater in intensity if the carbon nanomaterial exhibits greater amounts of functionalities or defects in the graphitic material. There were two sample types which were analyzed with both FTIR and Raman Spectroscopy for the research project: graphene nanoribbons and graphene oxide. The m-grade graphene nanoribbons (GNRs) were produced from m-grade carbon nanotubes (CNTs) via Tour's method. The graphene oxide (GO) was produced from graphene via Tour's method, sonicated and centrifuged, dip-coated onto Copper (Cu) foil, and then photoreduced under a UV light source. FTIR measurements and analyses were conducted using a Jasco FTIR Spectrometer. Raman measurements and analyses were conducted using a Jasco Laser Raman Spectrometer. Tasks and techniques for this project included photoreduction, dip-coating, corrosion testing, FTIR and Raman data collection and analysis, and improvement of data collection for the Raman Spectrometer. GNRs exfoliated and reduced (deoxygenation) at 270 deg. C in air showed a significant decrease in O functionalities according to FTIR. However, Raman revealed that a large increase in graphene planar and edge defects are present as indicated by the disorder band at 1340 cm-1. Further optimization could be performed by thermal exfoliation at lower temperatures assuming a need for fewer structural defects. Graphene oxide coatings showed clear reduction with an increase with photoreduction time. Raman revealed that the reduced graphene oxide films had less disruption in the planar phonon lattice vibrations which indicates that the structure is returning to sp2 hybridization of pristine graphene without adding structural defects.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Preparation of nitrogen doped TiO{sub 2} photocatalyst by oxidation of titanium nitride with H{sub 2}O{sub 2}

Highlights: {yields} N-doped TiO{sub 2} are prepared by hydrothermally treating TiN with H{sub 2}O{sub 2}. {yields} The content of N in TiO{sub 2} can be controlled by the concentration of H{sub 2}O{sub 2}. {yields} The as-prepared N-TiO{sub 2} shows higher photocatalytic activity under visible light. -- Abstract: Nitrogen doped anatase TiO{sub 2} (N-TiO{sub 2}) were prepared by hydrothermally treating TiN with H{sub 2}O{sub 2}. The as-synthesized samples were characterized by X-ray diffraction (XRD), transmission electron microscope (TEM), UV-vis diffuse reflectance spectrum (DRS), Fourier transform infrared spectra (FT-IR) and X-ray photoelectron spectroscopy (XPS) techniques. The results confirmed that the hydrothermal oxidation is an effective method to prepare N-doped TiO{sub 2} anatase. The nitrogen concentration in TiO{sub 2} could be controlled by the concentration of H{sub 2}O{sub 2} solution. Photocatalytic degradation of methyl orange (MO) was carried out under visible light and UV-visible light irradiation, respectively. The as-prepared optimal N-TiO{sub 2} showed higher photocatalytic activity than N-P25 and P25, and exhibited excellent reusability.

36 MATERIALS SCIENCE↗

Small-core chalcogenide microstructured fibers for the infrared

We report several small-core chalcogenide microstructured fibers fabricated by the 'Stack and Draw' technique from Ge15Sb20S65 glass with regular profiles. Mode field diameters and losses have been measured at 1.55 {mu}m. For one of the presented fibers, the pitch is 2.5 {mu}m, three times smaller than that already obtained in our previous work, and the corresponding mode field diameter is now as small as 3.5 {mu}m. This fiber, obtained using a two step 'Stack and Draw' technique, is single-mode at 1.55 {mu}m from a practical point of view. We also report the first measurement of the attenuation between 1 and 3.5 {mu}m of a chalcogenide microstructured fiber. Experimental data concerning fiber attenuation and mode field diameter are compared with calculations. Finally, the origin of fiber attenuation and the nonlinearity of the fibers are discussed.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Infrared Fabry-Perot and heterodyne spectrometers

The status of infrared instrumentation for astronomical investigations at U.C. Berkeley is described with emphasis on the techniques of high spectral and spatial resolution. Present instrumentation includes three Fabry-Perot spectrometers for the 10, 20, and 100 micron wavelength regions, a submillimeter receiver using an optically pumped laser, a 10 micron heterodyne spectrometer for studies of planetary atmospheres, and a 2-element 10 micron stellar interferometer for measuring the angular diameters of infrared stars.

Betz, A.↗

Analysis of far-infrared emission Fourier transform spectra

An analysis method that uses the nonlinear least-squares fit technique has been developed for emission spectra obtained with a Fourier transform spectrometer. This method is used for the analysis of submillimeter-region atmospheric emission spectra obtained with a balloon-borne FT spectrometer that was carried out as a correlative measurement for the Limb IR Monitor of the Stratosphere (LIMS) satellite experiment. The retrieved mixing ratios of H2O and O3 in the stratosphere from four spectral intervals have standard deviations of about 10 percent, and the average values agree to within 10 percent of corresponding results from the LIMS satellite experiment which used a broadband emission radiometer in the IR region.

Park, J. H.↗

Remote Sensing of Planetary Surfaces

Our efforts have been focused on understanding the physical properties of planetary surfaces using remote sensing techniques. Specific application has been to the surfaces of the Moon and Mars. Our approach has been to use thermal-infrared emission and radar reflectance and scattering as a way of exploring the decimeter-scale structure of these surfaces. At this scale, the techniques are sensitive to physical parameters such as the average or effective particle size of surface materials, the degree of induration or physical bonding between individual regolith grains, and the abundance of rocks of different sizes resting on or admixed in to the surface. The results are relevant to understanding the geological processes that have affected the surface and, in the case of Mars, determining site safety and scientific relevance for planning upcoming lander, rover, and sample-return spacecraft missions. Specific results are discussed below, and publications that have resulted are listed at the end.

Jakosky, Bruce M.↗

Mid-infrared nuller for Terrestrial Planet Finder: design progress and results

Nulling interferometry shows promise as a technique enabling investigation of faint objects such as planets and exo-zodiacal dust around nearby stars. At Jet Propulsion Laboratory, a nulling beam combiner based on a design built for the Keck Observatory in Hawaii has been used to pursue deep and stable narrowband nulls. We describe the design and layout of the Modified Mach Zehnder TPF nuller, and the results achieved in the laboratory to date. We report the stabilized 900,000 nulls achieved using a CO2 laser, and discuss the performance limitations and way forward to the deep, broadband nulls required for a space-borne nulling interferometer mission. We show briefly the results from Keck breadboard experiments: broadband transient nulls centered around 10.6 micron have been achieved ranging between 17500 at 18% bandwidth and 7500:1 at 29% bandwidth.

Serabyn, E.↗

Management applications for thermal IR imagery of lake processes

A thermal infrared scanning program was conducted in the Lake Ontario Basin region in an effort to determine: (1) limonologic data that could be collected by remote sensing techniques, and (2) local interest in and routine use of such data in water management programs. Difficulties encountered in the development of an infrared survey program in New York suggest that some of the major obstacles to acceptance of remotely sensed data for routine use are factors of psychology rather than technology. Also, terminology used should suit the measurement technique in order to encourage acceptance of the surface thermal data obtained.

Whipple, J. M.↗

Recent Advancements in the Infrared Flow Visualization System for the NASA Ames Unitary Plan Wind Tunnels

The following details recent efforts undertaken at the NASA Ames Unitary Plan wind tunnels to design and deploy an advanced, production-level infrared (IR) flow visualization data system. Highly sensitive IR cameras, coupled with in-line image processing, have enabled the visualization of wind tunnel model surface flow features as they develop in real-time. Boundary layer transition, shock impingement, junction flow, vortex dynamics, and buffet are routinely observed in both transonic and supersonic flow regimes all without the need of dedicated ramps in test section total temperature. Successful measurements have been performed on wing-body sting mounted test articles, semi-span floor mounted aircraft models, and sting mounted launch vehicle configurations. The unique requirements of imaging in production wind tunnel testing has led to advancements in the deployment of advanced IR cameras in a harsh test environment, robust data acquisition storage and workflow, real-time image processing algorithms, and evaluation of optimal surface treatments. The addition of a multi-camera IR flow visualization data system to the Ames UPWT has demonstrated itself to be a valuable analyses tool in the study of new and old aircraft/launch vehicle aerodynamics and has provided new insight for the evaluation of computational techniques.

Infrared Thermography↗

Impacts of electrode coating irregularities on polymer electrolyte membrane fuel cell lifetime using quasi in-situ infrared thermography and accelerated stress testing

In-line quality control diagnostics for roll-to-roll (R2R) manufacturing techniques will play a key role in the future commercialization of the polymer electrolyte membrane fuel cell (PEMFC) used in automotive applications. These diagnostics monitor the fabrication of the membrane electrode assembly (MEA), which detect and flag any non-uniformity that may potentially harm PEMFC performance and/or lifetime. This will require quantitative thresholds and a clear distinction between harmful defects and harmless coating irregularities. Thus, novel fuel cell hardware with quasi in-situ infrared (IR) thermography capabilities is utilized to understand how bare spots in the cathode electrode impact MEA lifetime. An accelerated stress test (AST) simulates chemical and mechanical degradation modes seen in vehicular operation. The actual open circuit voltage and rate of change of this voltage are used as in-situ indicators for MEA failure, enabling capture of the progression of failure point development. Bare spot coating irregularities located at the center of the electrode were found to have no impact on MEA lifetime when compared to a pristine MEA. However, MEA lifetime was found to be considerably shortened when these same irregularities are located at the cathode inlet and, especially, the anode inlet regions of the fuel cell.

36 MATERIALS SCIENCE↗

Infrared and far-infrared laser magnetic resonance spectroscopy of the GeH radical - Determination of ground state parameters

The GeH radical has been detected in its ground 2 Pi state in the gas phase reaction of fluorine atoms with GeH4 by laser magnetic resonance techniques. Rotational transitions within both 2 Pi 1/2 and 2 Pi 3/2 manifolds have been observed at far-infrared wavelengths and rotational transitions between the two fine structure components have been detected at infrared wavelengths (10 microns). Signals have been observed for all five naturally occurring isotopes of germanium. Nuclear hyperfine structure for H-1 and Ge-73 has also been observed. The data for the dominant isotope (/Ge-74/H) have been fitted to within experimental error by an effective Hamiltonian to give a set of molecular parameters for the X 2 Pi state which is very nearly complete. In addition, the dipole moment of GeH in its ground state has been estimated from the relative intensities of electric and magnetic dipole transitions in the 10 micron spectrum to be 1.24(+ or - 0.10) D.

Brown, J. M.↗