Search NASA⌕ Search

SEARCH · Search NASA

Results for “LOSSES”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,423 records · Page 79

Anomalous Circulation in July 2019 Resulting in Mass Loss on the Greenland Ice Sheet

Current mass loss on the Greenland Ice Sheet (GrIS) includes a significant contribution from surface runoff. The circumstances associated with melt events are important for understanding the global sea level contribution of the GrIS. In late July 2019, surface melt occurred over 62% of the GrIS, including Summit Station. The general circulation leading to the event is found to be dissimilar to 2012 and other events documented in the 21st century, with warm air associated with remote atmospheric blocking over western Europe eventually transiting west to the GrIS. Gravimetric data indicate that the 2019 summer mass loss was 137 Gt more than the 2004–2010 median, or about 92% of the 2012 record. Mass loss during the event was significant in GrIS northeastern regions in 2019. As compared to 2012, the southwest did not fully participate. Similar circulation patterns have not previously been associated with significant melt.

Richard I Cullather↗

Pervasive ice sheet mass loss reflects competing ocean and atmosphere processes

Quantifying changes in Earth’s ice sheets and identifying the climate drivers are central to improving sea level projections. We provide unified estimates of grounded and floating ice mass change from 2003 to 2019 using NASA’s Ice, Cloud and land Elevation Satellite (ICESat) and ICESat-2 satellite laser altimetry. Our data reveal patterns likely linked to competing climate processes: Ice loss from coastal Greenland (increased surface melt), Antarctic ice shelves (increased ocean melting), and Greenland and Antarctic outlet glaciers (dynamic response to ocean melting) was partially compensated by mass gains over ice sheet interiors (increased snow accumulation). Losses outpaced gains, with grounded-ice loss from Greenland (200 billion tonnes per year) and Antarctica (118 billion tonnes per year) contributing 14 millimeters to sea level. Mass lost from West Antarctica’s ice shelves accounted for more than 30% of that region’s total.

Ben Smith↗

Mitigation of Silver Ion Loss from Solution by Polymer Coating of Metal Surfaces, Part II

“Spacecraft potable water systems require a biocidal agent that effectively provides both immediate and residual disinfection over long periods of time. Ionic silver (Ag+) is a leading candidate for this application, but suffers from rapid concentration loss due to interactions with the metal storage containers and tubing. In order to maintain biocidal efficacy in systems with long periods of dormancy and to reduce the required rate of Ag+ injection, it is necessary to develop alternative materials and coatings for certified metal alloys that significantly reduce the Ag+loss.”1In this work, we continue our investigation of vapor-deposited parylene (AF4, and now C) polymers as conformal barrier coatings under long-term (ca. 1-year) immersion in ca. 400 ppb Ag+. The performanceof internal coatings in tubing/two-ferrule fitting systems is characterized. We report successful “aging” and high concentration Ag+pretreatment of parylene coatings for quantitative reduction of Ag+loss rates. In addition, we observe long-term blister-free adhesion of mechanically anchored parylene-AF4 on nano-structured Ti-6Al-4V alloy and chemically bonded parylene-C on 316L stainless steel. Finally, we report preliminary experiments with mechanical and chemical anchoring of laboratory-deposited parylene-C on 316L.

Silver↗

Extreme Ozone Loss Following Nuclear War Results in Enhanced Surface Ultraviolet Radiation

For the first time, we use a modern climate model with interactive chemistry including the effects of aerosols on photolysis rates to simulate the consequences of regional and global scale nuclear wars (injecting 5 and 150 Tg of soot respectively) for the ozone layer and surface ultraviolet (UV) light. For a global nuclear war, heating in the stratosphere, reduced photolysis, and an increase in catalytic loss from the Hox cycle cause a 15 year-long reduction in the ozone column, with a peak loss of 75% globally and 65% in the tropics. This is larger than predictions from the 1980s, which assumed large injections of nitrogen oxides (NOx),but did not include the effects of smoke. NOx from the fireball and the fires provide a small (5%) Increase to the global average ozone loss for the first few years. Initially, soot would shield the surface from UV-B, but UV Index values would become extreme: greater than 35in the tropics for 4years, and greater than 45during the summer in the southern polar regions for 3 years. For a regional war, global column ozone would be reduced by 25% with recovery taking 12 years. This is similar to previous simulations, but with a faster recovery time due to a shorter lifetime for soot in our simulations. In-line photolysis provides process specific action spectra enabling future integration with biogeochemistry models and allows output that quantifies the potential health impacts from changes in surface UV for this and other larger aerosol injections.

nuclear war↗

Extinction of the Stagnation Point Diffusion Flame: Effect of Conductive Heat Loss into Solid Interior

The planned microgravity experiment Growth and Extinction Limit (GEL) is designed to study the material flammability and extinction of thermally thick solid with an emphasis to quantify the effect of conductive heat loss into the solid interior by measuring the in-depth temperature profile. To obtain a more detailed understanding of the extinction phenomena, a previously developed one-dimensional axisymmetric stagnation-point diffusion flame model is expanded to account for the excessive heat loss into the solid beyond the steady burning state. This is important because for thick solids, this is important because the burning period can have a long and slow solid transient with a quasi-steady gas -phase. A non-dimensional excessive conductive heat loss parameter Ψ is defined in the paper and extensive numerical computations have been performed to determine the extinction boundary and the characteristics of near-limit flames. The classical U-shaped flammability boundary in the oxygen vs. stretch rate plot now becomes a series of U-shaped boundaries as a function of Ψ. For a given oxygen ambient, extinction boundary is a function of Ψ. The boundary consists of a blowoff branch and a radiative quenching branch. This is similar to the steady burning flammability boundary (Ψ =0) in the oxygen vs stretch rate plot. Extensive computed data including flame and pyrolysis temperatures, burning rate, flame standoff distance, and reaction rate are presented along the extinction boundaries. In particular, we note that the non-dimensional gas reaction rate is the ratio of diffusion reaction time to the reaction diffusion time, so it has the classical Damhkoler number character. By examining the maximum non-dimensional reaction rates, we observe that along the extinction boundaries, they are approximate constant across the entire range of stretch rates (from quenching to blow-off). These critical values are of the order unity but may vary in different oxygen ambient. The implication will be discussed in the presentation together with the near-limit flame structures.

Chengyao Li↗

Biodiversity loss reduces global terrestrial carbon storage

Natural ecosystems store large amounts of carbon globally, as organisms absorb carbon from the atmosphere to build large, long-lasting, or slow-decaying structures such as tree bark or root systems. An ecosystem’s carbon sequestration potential is tightly linked to its biological diversity. Yet when considering future projections, many carbon sequestration models fail to account for the role biodiversity plays in carbon storage. Here, we assess the consequences of plant biodiversity loss for carbon storage under multiple climate and land-use change scenarios. We link a macroecological model projecting changes in vascular plant richness under different scenarios with empirical data on relationships between biodiversity and biomass. We find that biodiversity declines from climate and land use change could lead to a global loss of between 7.44-103.14 PgC (global sustainability scenario) and 10.87-145.95 PgC (fossil-fueled development scenario). This indicates a self-reinforcing feedback loop, where higher levels of climate change lead to greater biodiversity loss, which in turn leads to greater carbon emissions and ultimately more climate change. Conversely, biodiversity conservation and restoration can help achieve climate change mitigation goals.

Biodiversity↗

Spacecraft Radiator Protection from Ionizing Radiation, Dust, and Excessive Heat Loss

Under a Phase II SBIR project funded by NASA Johnson Space Center (Contract No. 80NSSC25C0088), Analytical Scientific Products LLC (ASP) has been developing an actively controlled louver to protect spacecraft radiators from degradation due to exposure to various types of environmental conditions. Of particular interest are ionizing radiation during spacecraft transit through the Van Allen belts, dust during spacecraft landing and surface operations on the moon, and excessive heat loss during the long lunar night especially near the poles where the local ambient temperatures can drop below -200°C. Exposure to ionizing radiation and dust can degrade the optical properties of the radiator coating that in turn reduces its ability to reject excess heat from the spacecraft into the environment. Exposure to the extremely low temperature conditions during the lunar night near the poles can freeze the radiator fluids that can compromise the integrity of the radiator. Passive louvers constructed using thick aluminum vanes are used currently to protect spacecraft radiators from some of the above effects, but they have several drawbacks: (i) their high aerial density makes it impractical to scale them to protect the much larger spacecraft radiators needed for future manned missions to the moon and beyond, (ii) the bimetallic actuators used to open and close the vanes in passive louvers rely on external temperature alone and so the louver cannot offer protection from dust and ionizing radiation when the ambient temperatures are high, and (iii) the bimetallic actuators need time scales of the order of hours to open and close. We have addressed the above limitations of passive louvers through the development of a low aerial density and rapidly actuating actively controlled louver. It is constructed from a custom alloy that offers much higher levels of protection against the ionizing radiation, dust and excessive heat loss at a fraction of weight compared to passive louvers while providing opening and closing time scales of the order of a second. Our modular design makes it easy to scale the system up or down depending on the application. We have recently constructed a 31 inch × 31 inch module of this louver and tested its functionality and effectiveness. These tests have shown that the louver can be opened and closed in less than 2 s. It reduces the transmission of ionizing radiation by 78% to 100% (depending on the radiation source), dust transmission by more than 93%, and heat loss by more than 97%. We are currently preparing to evaluate this device at the Johnson Space Center’s cryogenic vacuum chamber where it can be subjected to simulated lunar surface conditions. This paper provides a detailed discussion of the test designs as well as the data from tests that demonstrate the effectiveness in reducing the transmission of ionizing radiation, dust, and heat under laboratory conditions.

Radiator↗

Spacecraft Radiator Protection from Ionizing Radiation, Dust, and Excessive Heat Loss

Under a Phase II SBIR project funded by NASA Johnson Space Center (Contract No. 80NSSC25C0088), Analytical Scientific Products LLC (ASP) has been developing an actively controlled louver to protect spacecraft radiators from degradation due to exposure to various types of environmental conditions. Of particular interest are ionizing radiation during spacecraft transit through the Van Allen belts, dust during spacecraft landing and surface operations on the moon, and excessive heat loss during the long lunar night especially near the poles where the local ambient temperatures can drop below -200°C. Exposure to ionizing radiation and dust can degrade the optical properties of the radiator coating that in turn reduces its ability to reject excess heat from the spacecraft into the environment. Exposure to the extremely low temperature conditions during the lunar night near the poles can freeze the radiator fluids that can compromise the integrity of the radiator. Passive louvers constructed using thick aluminum vanes are used currently to protect spacecraft radiators from some of the above effects, but they have several drawbacks: (i) their high aerial density makes it impractical to scale them to protect the much larger spacecraft radiators needed for future manned missions to the moon and beyond, (ii) the bimetallic actuators used to open and close the vanes in passive louvers rely on external temperature alone and so the louver cannot offer protection from dust and ionizing radiation when the ambient temperatures are high, and (iii) the bimetallic actuators need time scales of the order of hours to open and close. We have addressed the above limitations of passive louvers through the development of a low aerial density and rapidly actuating actively controlled louver. It is constructed from a custom alloy that offers much higher levels of protection against the ionizing radiation, dust and excessive heat loss at a fraction of weight compared to passive louvers while providing opening and closing time scales of the order of a second. Our modular design makes it easy to scale the system up or down depending on the application. We have recently constructed a 31 inch × 31 inch module of this louver and tested its functionality and effectiveness. These tests have shown that the louver can be opened and closed in less than 2 s. It reduces the transmission of ionizing radiation by 78% to 100% (depending on the radiation source), dust transmission by more than 93%, and heat loss by more than 97%. We are currently preparing to evaluate this device at the Johnson Space Center’s cryogenic vacuum chamber where it can be subjected to simulated lunar surface conditions. This paper provides a detailed discussion of the test designs as well as the data from tests that demonstrate the effectiveness in reducing the transmission of ionizing radiation, dust, and heat under laboratory conditions.

Radiator↗

Analysis of beam loss mechanism in the Project X linac

Minimization of the beam losses in a multi-MW H{sup -} linac such as ProjectX to a level below 1 W/m is a challenging task. The impact of different mechanism of beam stripping, including stripping in electric and magnetic fields, residual gas, blackbody radiation and intra-beam stripping, is analyzed. Other sources of beam losses are misalignements of beamline elements and errors in RF fields and phases. We present in this paper requirements for dynamic errors and correction schemes to keep beam losses under control.

43 PARTICLE ACCELERATORS↗

A novel digitization scheme with FPGA-base TDC for beam loss monitors operating at cryogenic temperature

Recycling integrators are common current-to-frequency converting circuits for measurements of low current such as that produced by Fermilab's cryogenic ionization chambers. In typical digitization/readout schemes, a counter is utilized to accumulate the number of pulses generated by the recycling integrator to adequately digitize the total charge. In order to calculate current with reasonable resolution (e.g., 7-8 bits), hundreds of pulses must be accumulated which corresponds to a long sampling period, i.e., a very low sampling rate. In our new scheme, an FPGA-based Time-to-Digital Convertor (TDC) is utilized to measure the time intervals between the pulses output from the recycling integrator. Using this method, a sample point of the current can be made with good resolution (>10 bits) for each pulse. This effectively increases the sampling rates by hundreds of times for the same recycling integrator front-end electronics. This scheme provides a fast response to the beams loss and is potentially suitable for accelerator protection applications. Moreover, the method is also self-zero-suppressed, i.e., it produces more data when the beam loss is high while it produces significantly less data when the beam loss is low.

43 PARTICLE ACCELERATORS↗

The LCLS Undulator Beam Loss Monitor Readout System

The LCLS Undulator Beam Loss Monitor System is required to detect any loss radiation seen by the FEL undulators. The undulator segments consist of permanent magnets which are very sensitive to radiation damage. The operational goal is to keep demagnetization below 0.01% over the life of the LCLS. The BLM system is designed to help achieve this goal by detecting any loss radiation and indicating a fault condition if the radiation level exceeds a certain threshold. Upon reception of this fault signal, the LCLS Machine Protection System takes appropriate action by either halting or rate limiting the beam. The BLM detector consists of a PMT coupled to a Cherenkov radiator located near the upstream end of each undulator segment. There are 33 BLMs in the system, one per segment. The detectors are read out by a dedicated system that is integrated directly into the LCLS MPS. The BLM readout system provides monitoring of radiation levels, computation of integrated doses, detection of radiation excursions beyond set thresholds, fault reporting and control of BLM system functions. This paper describes the design, construction and operational performance of the BLM readout system.

43 PARTICLE ACCELERATORS↗

Systems, methods and computer readable media for estimating capacity loss in rechargeable electrochemical cells

A system includes an electrochemical cell, monitoring hardware, and a computing system. The monitoring hardware periodically samples charge characteristics of the electrochemical cell. The computing system periodically determines cell information from the charge characteristics of the electrochemical cell. The computing system also periodically adds a first degradation characteristic from the cell information to a first sigmoid expression, periodically adds a second degradation characteristic from the cell information to a second sigmoid expression and combines the first sigmoid expression and the second sigmoid expression to develop or augment a multiple sigmoid model (MSM) of the electrochemical cell. The MSM may be used to estimate a capacity loss of the electrochemical cell at a desired point in time and analyze other characteristics of the electrochemical cell. The first and second degradation characteristics may be loss of active host sites and loss of free lithium for Li-ion cells.

30 DIRECT ENERGY CONVERSION↗

ANALYZING SURFACE ROUGHNESS DEPENDENCE OF LINEAR RF LOSSES

Topographic structure on Superconductivity Radio Frequency (SRF) surfaces can contribute additional cavity RF losses describable in terms of surface RF reflectivity and absorption indices of wave scattering theory. At isotropic homogeneous extent, Power Spectrum Density (PSD) of roughness is introduced and quantifies the random surface topographic structure. PSD obtained from different surface treatments of niobium, such Buffered Chemical Polishing (BCP), Electropolishing (EP), Nano-Mechanical Polishing (NMP) and Barrel Centrifugal Polishing (CBP) are compared. A perturbation model is utilized to calculate the additional rough surface RF losses based on PSD statistical analysis. This model will not consider that superconductor becomes normal conducting at fields higher than transition field. One can calculate the RF power dissipation ratio between rough surface and ideal smooth surface within this field range from linear loss mechanisms.

43 PARTICLE ACCELERATORS↗

MEASUREMENT AND DETAILED SIMULATION OF BEAM LOSSES CAUSED BY THIN INTERCEPTION DEVICES (WIRE SCANNERS, SCRAPERS) AT SNS

Conversion of BLM readings between into number of lost particles is a challenging task. Any insertion device is a good mean to obtain a localized loss and obtain such conversion factor with direct measurement. Such a measurement serves as a good benchmark for Monte-Carlo simulation of radiation transport. We used wire scanners and scraper induced losses to perform analysis of BLM response to local loss. The paper also provides a technique to measure 0.1% of full beam charge being intercepted by scraper during 650kW production run extracting the useful signal from high noise (20 times higher than signal) environment

Zhukov, Alexander P↗

Understanding ion cyclotron harmonic fast wave heating losses in the scrape off layer of tokamak plasmas

Fast waves at harmonics of the ion cyclotron frequency, which have been used successfully on National Spherical Torus Experiment (NSTX), will also play an important role in ITER and are a promising candidate for the Fusion Nuclear Science Facility (FNSF) designs based on spherical torus (ST). Experimental studies of high harmonic fast waves (HHFW) heating on the NSTX have demonstrated that substantial HHFW power loss occurs along the open field lines in the scrape-off layer (SOL), but the mechanism behind the loss is not yet understood. The full wave RF code AORSA, in which the edge plasma beyond the last closed flux surface (LCFS) is included in the solution domain, is applied to specific NSTX discharges in order to predict the effects and possible causes of this power loss. In the studies discussed here, a collisional damping parameter has been implemented in AORSA as a proxy to represent the real, and most likely nonlinear, damping processes. A prediction for the NSTX Upgrade (NSTX-U) experiment, that will begin operation next year, is also presented, indicating a favorable condition for the experiment due to a wider evanescent region in edge density.*Research supported by the U.S. DOE under Contract No. DE-AC02-09CH11466 with Princeton University.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Predicting Future Soiling Losses Using Environmental Data: Preprint

Soiling consists of the accumulation of dust and dirt on the surfaces of photovoltaic (PV) modules and causes a reduction in the energy conversion. Investors generally consider an average yearly soiling loss to estimate the energy yield and the economic revenue of a site for a new PV installation. If soiling could be estimated from wide available parameters, describing the pollution and the rainfall pattern at a site, more accurate losses could be predicted, reducing the uncertainty in the estimation of the energy yield and therefore the finance rates offered for new PV systems. The present work investigates the correlations between present environmental parameters and future soiling losses.

14 SOLAR ENERGY↗

An Analytical Methodology to Evaluate Thermal-Hydraulic Performance of Compact Heat Exchangers, Accounting for Heat Loss

High efficiency and compactness, offered by the Printed Circuit Heat Exchanger (PCHE) makes it a strong candidate for use as an Intermediate Heat Exchanger (IHX) and/or Secondary Heat Exchanger (SHX) for Advanced High Temperature Reactor (AHTR) systems and also the Very High Temperature Reactor (VHTR). Idaho National Laboratory (INL) has been developing a computer code for the PCHE design and analysis [1], and will construct an experimental loop to evaluate the thermal hydraulic performance of PCHEs [2]. In order to correctly compare experimental results with the simulations, the extraneous heat losses from the PCHEs must be determined and incorporated. These heat exchangers operate at high temperature and consequently, despite the use of external thermal insulation, experience non-negligible heat losses to the surroundings. The objective of this work is to develop an analytical methodology for quantification of these heat losses based on experimental data to evaluate and predict the performance of the heat exchanger accurately.

99 GENERAL AND MISCELLANEOUS↗

Effect of Torque-Tube Parameters on Rear-Irradiance and Rear-Shading Loss for Bifacial PV Performance on Single-Axis Tracking Systems: Preprint

The emergence of cost-competitive bifacial PV modules has raised the question of the additional value of bifacial modules in 1-axis tracking arrays, in particular when considering rear-irradiance losses from the tracker system itself. In this work, the effect of different geometries and materials of torque tubes is evaluated and found to reduce rear-irradiance averages without any torque-tube shading by 0.1 to 12% for metallic and black absorptive torque tubes respectively for a clear-sky day. This paper will compare modeled to measured rear-irradiance profiles, and propose a recommended range of rear-shading loss factors for different geometry conditions. The effect of rear-irradiance distribution into electrical mismatch loss will also be explored.

14 SOLAR ENERGY↗