Search NASA⌕ Search

SEARCH · Search NASA

Results for “Material point method”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,423 records · Page 79

Two-Dimensional Space-Time Dependent Multi-group Diffusion Equation with SLOR Method

The research of two-dimensional space-time diffusion equations with SLOR (Successive-Line Over Relaxation) has been done. SLOR method is chosen because this method is one of iterative methods that does not required to defined whole element matrix. The research is divided in two cases, homogeneous case and heterogeneous case. Homogeneous case has been inserted by step reactivity. Heterogeneous case has been inserted by step reactivity and ramp reactivity. In general, the results of simulations are agreement, even in some points there are differences.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Single microparticle launching method using two-stage light-gas gun for simulating hypervelocity impacts of micrometeoroids and space debris

A single microparticle launching method is described to simulate the hypervelocity impacts of micrometeoroids and microdebris on space structures at the Institute of Space and Astronautical Science, Japan Aerospace Exploration Agency. A microparticle placed in a sabot with slits is accelerated using a rifled two-stage light-gas gun. The centrifugal force provided by the rifling in the launch tube separates the sabot. The sabot-separation distance and the impact-point deviation are strongly affected by the combination of the sabot diameter and the bore diameter, and by the projectile diameter. Using this method, spherical projectiles of 1.0-0.1 mm diameter were launched at up to 7 km/s.

36 MATERIALS SCIENCE↗

Design and development of liquid filled polymeric fibers with flexure rate viscoelastic properties

The design and development of a novel category of bi-component polymeric fibers, made of a polymeric sheath and a liquid core is described. To understand and to analyze the flow of molten polymer and liquid within a spin pack, we built a macroscale analogon where co-flow of polymer and liquid is investigated systematically. The macroscale analogon is composed of a glass cylinder with a finite length and a coaxial capillary. The inner fluid flows in the capillary and at its outlet meets the outer fluid flowing inside the glass cylinder. The fluids are pumped into the setup using pressurized bottles with controlled flow rates. A high-speed camera is placed in front of the glass cylinder to record the transient and the steady flow of the two phases and the morphology of their interface during co-flow. We systematically analyzed the combination of various fluids and different injection channel geometries, and used these findings to design a customized spin pack. Extrusion trials with molten polymers and specific liquids resulted in the production of liquid filled polymeric fibers (LFF) with different amounts of liquid from 3% to 33%vol. and diameters from 150μm to 1mm. Fiber morphology has been investigated with the help of optical microscopy and computer tomography, in order to analyze both surface and core morphology. Mechanical characterization of fibers has been carried out with special care to the damping capacity of such fibers using two different methods: two point bending tests to evaluate the energy dissipation of fibers upon bending at low frequency values (0.005-0.5Hz), and analysis of vibration reduction to determine the quality factor at the resonance frequency of the 1{sup st} and 3{sup rd} vibration mode.

36 MATERIALS SCIENCE↗

Replication and characterization of the compound eye of a fruit fly for imaging purpose

In this work, we report the replication and characterization of the compound eye of a fruit fly for imaging purpose. In the replication, soft lithography method was employed to replicate the compound eye of a fruit fly into a UV-curable polymer. The method was demonstrated to be effective and the compound eye is replicated into the polymer (NOA78) where each ommatidium has a diameter of about 30 μm and a sag height of about 7 μm. To characterize its optical property, the point spread function of the compound eye was tested and a NA of 0.386 has been obtained for the replicated polymeric ommatidium. Comparing with the NA of a real fruit fly ommatidium which was measured to be about 0.212, the replicated polymeric ommatidium has a much larger NA due to the refractive index of NOA78 is much higher than that of the material used to form the real fruit fly ommatidium. Furthermore, the replicated compound eye was used to image a photomask patterned with grating structures to test its imaging property. It is shown that the grating with a line width of 20 μm can be clearly imaged. The image of the grating formed by the replicated compound eye was shrunk by about 10 times and therefore a line width of about 2.2 μm in the image plane has been obtained, which is close to the diffraction limited resolution calculated through the measured NA. In summary, the replication method demonstrated is effective and the replicated compound eye has the great potential in optical imaging.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Characteristics of miniature electronic brachytherapy x-ray sources based on TG-43U1 formalism using Monte Carlo simulation techniques

Purpose: The goal of this study is to determine a method for Monte Carlo (MC) characterization of the miniature electronic brachytherapy x-ray sources (MEBXS) and to set dosimetric parameters according to TG-43U1 formalism. TG-43U1 parameters were used to get optimal designs of MEBXS. Parameters that affect the dose distribution such as anode shapes, target thickness, target angles, and electron beam source characteristics were evaluated. Optimized MEBXS designs were obtained and used to determine radial dose functions and 2D anisotropy functions in the electron energy range of 25-80 keV. Methods: Tungsten anode material was considered in two different geometries, hemispherical and conical-hemisphere. These configurations were analyzed by the 4C MC code with several different optimization techniques. The first optimization compared target thickness layers versus electron energy. These optimized thicknesses were compared with published results by Ihsan et al.[Nucl. Instrum. Methods Phys. Res. B 264, 371-377 (2007)]. The second optimization evaluated electron source characteristics by changing the cathode shapes and electron energies. Electron sources studied included; (1) point sources, (2) uniform cylinders, and (3) nonuniform cylindrical shell geometries. The third optimization was used to assess the apex angle of the conical-hemisphere target. The goal of these optimizations was to produce 2D-dose anisotropy functions closer to unity. An overall optimized MEBXS was developed from this analysis. The results obtained from this model were compared to known characteristics of HDR {sup 125}I, LDR {sup 103}Pd, and Xoft Axxent electronic brachytherapy source (XAEBS) [Med. Phys. 33, 4020-4032 (2006)]. Results: The optimized anode thicknesses as a function of electron energy is fitted by the linear equation Y ({mu}m) = 0.0459X (keV)-0.7342. The optimized electron source geometry is obtained for a disk-shaped parallel beam (uniform cylinder) with 0.9 mm radius. The TG-43 distribution is less sensitive to the shape of the conical-hemisphere anode than the hemispherical anode. However, the optimized apex angle of conical-hemisphere anode was determined to be 60 deg. For the hemispherical targets, calculated radial dose function values at a distance of 5 cm were 0.137, 0.191, 0.247, and 0.331 for 40, 50, 60, and 80 keV electrons, respectively. These values for the conical-hemisphere targets are 0.165, 0.239, 0.305, and 0.412, respectively. Calculated 2D anisotropy functions values for the hemispherical target shape were F(1 cm, 0 deg.) = 1.438 and F(1 cm, 0 deg.) = 1.465 for 30 and 80 keV electrons, respectively. The corresponding values for conical-hemisphere targets are 1.091 and 1.241, respectively. Conclusions: A method for the characterizations of MEBXS using TG-43U1 dosimetric data using the MC MCNP4C has been presented. The effects of target geometry, thicknesses, and electron source geometry have been investigated. The final choices of MEBXS design are conical-hemisphere target shapes having an apex angle of 60 deg. Tungsten material having an optimized thickness versus electron energy and a 0.9 mm radius of uniform cylinder as a cathode produces optimal electron source characteristics.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Improving the Desulfurization Degree of High-Grade Nickel Matte via a Two-Step Oxidation Roasting Process

Generally, sulfur elimination from nickel matte was incomplete in the one-step oxidation roasting process. In this work, X-ray diffraction, scanning electron microscopy/energy-dispersive X-ray spectroscopy, and chemical analysis of the roasted products were carried out to explain this phenomenon. The results indicated that the melting of heazlewoodite was the main limiting factor. Thereafter, the oxidation mechanism of high-grade nickel matte from room temperature to 1000 °C was studied. It was found that the transformation from heazlewoodite (Ni{sub 3}S{sub 2}) to nickel sulfide (NiS) took place from 400 °C to 520 °C. Considering that the melting temperature of NiS was much higher than that of Ni{sub 3}S{sub 2}, a low-temperature roasting step was suggested to suppress the melting of heazlewoodite. Under the optimum conditions (520 °C for 120 minutes followed by 800 °C for 80 minutes), the degree of desulfurization reached 99.52 pct. These results indicated that the two-step oxidation roasting method could be a promising process for producing low-sulfur calcine from high-grade nickel matte.

36 MATERIALS SCIENCE↗

First-principles investigation of the thermo-physical properties of Ca{sub 3}Si{sub 4}

The first-principles calculations were applied to investigate the thermo-physical properties of Ca{sub 3}Si{sub 4} compound with increasing pressure. Those properties are based on density functional theory (DFT) method within the generalized gradient approximation (GGA) and local density approximation (LDA) for exchange and correlation. The optimized lattice constant and formation enthalpy are in good agreement with the experimental data and other theoretical data available. The calculated band structures confirm that Ca{sub 3}Si{sub 4} is a semiconductor with an indirect band gap of 0.363 eV (GGA) and 0.311 eV (LDA) at 0 GPa, and the calculated band gap decreased with the increasing pressure. The elastic constants, elastic anisotropy, elastic moduli and Poisson's ratio of Ca{sub 3}Si{sub 4} have also been obtained under high pressures. The Debye temperature, heat capacity, coefficient of thermal expansion and Grueneisen parameter have also been calculated in the quasiharmonic Debye model. - Graphical abstract: The Partial Density of States and Band Structure of Ca{sub 3}Si{sub 4}. Highlights: Black-Right-Pointing-Pointer The thermo-physical properties of Ca{sub 3}Si{sub 4} have been investigated. Black-Right-Pointing-Pointer Ca{sub 3}Si{sub 4} is a semiconductor with an indirect band gap. Black-Right-Pointing-Pointer The mechanical properties of Ca{sub 3}Si{sub 4} have been studied. Black-Right-Pointing-Pointer The heat capacity and thermal expansion have been obtained.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Study of structural, elastic, electronic and optical properties of seven SrZrO{sub 3} phases: First-principles calculations

On the plane-wave ultrasoft pseudopotential technique based on the first-principles density functional theory (DFT), we calculated the structural, elastic, electronic and optical properties of the seven different phases of SrZrO{sub 3}. The obtained ground-state properties are in good agreement with previous experiments and calculations, which indicate that the most stable phase is orthorhombic Pnma structure. Seven phases of SrZrO{sub 3} are mechanically stable with cubic, tetragonal and orthorhombic structures. The mechanical and thermodynamic properties have been obtained by using the Voigt-Reuss-Hill approach and Debye-Grueneisen model. The electronic structures and optical properties are obtained and compared with the available experimental and theoretical data. - Graphical abstract: Energy versus volume of seven phases SrZrO{sub 3} shows the Pnma phase has the minimum ground-state energy. Highlights: Black-Right-Pointing-Pointer We calculated the physical and chemical properties of seven SrZrO{sub 3} polymorphs. Black-Right-Pointing-Pointer The order of stability is Pnma>Imma>Cmcm>I4/mcm>P4/mbm>P4mm>Pm3-bar m. Black-Right-Pointing-Pointer The most stable phase is orthorhombic Pnma structure. Black-Right-Pointing-Pointer Seven phases of SrZrO{sub 3} are mechanically stable. Black-Right-Pointing-Pointer The relationship between n and {rho}{sub m} is n=1+0.18{rho}{sub m}.

36 MATERIALS SCIENCE↗

Thermal Diffusivity Measurement of Irradiated SiC-SiC Composite Material

Silicon Carbide fiber and matrix composite (SiC-SiC) is being considered as a fuel cladding candidate because of its high melting point, low susceptibility to corrosion, good thermal and mechanical shock resistance, and low degradation of mechanical properties under irradiation. The thermal properties of SiC-SiC composite depend heavily on the fabrication process, thus cannot be simply referenced from available database. Similarly, the influence of irradiation on SiC-SiC composite thermal properties needs to be measured to provide general trends of property degradation. For ion irradiated samples, the damaged layer is only a few to a few tens of micrometers. It is impossible to directly measure the bulk property change of a SiC-SiC composite because of the thin, damaged layer. This paper focuses on a methodology that is based on microscale measurement of fiber and matrix properties to determine the overall bulk property change due to ion irradiation. Laser-based photothermal reflectance technique is one of the ideal methods to measure local thermal conductivity and diffusivity with high spatial resolution. The main principle of this technique is to heat the solid sample using an intensity-modulated laser, and scan the sample with a constant intensity continuous-wave (CW) laser to detect the phase lag of the thermal wave propagation. On bulk, isotropic material, if the heating laser intensity is modulated as a sine wave, thermal diffusivity of the sample can be derived from the phase lag, scan distance and modulation frequency in a straight forward manner. By using more specific analytical models, thermal conductivity and diffusivity in complicated cases, such as layered structure materials, composite materials, and/or anisotropic materials, are measurable as well. In this work, a new measurement approach of SiC-SiC composite thermal diffusivity is presented. Due to the micrometer spatial resolution of the photothermal reflectance technique, the measurements are performed locally on fibers along both radial and axial directions, and on the matrix. The influence of Silicon ion irradiation (75 MeV, 10 dpa) is then examined by comparing the experimental results of samples before and after irradiation. (authors)

36 MATERIALS SCIENCE↗

On the delta-type doping of GaAs-based heterostructures with manganese compounds

Heterostructures, which incorporate GaAs/InGaAs/GaAs quantum wells and are doped with spatially remote monatomic Mn layers, are formed on GaAs(001) substrate under conditions of multilayer buildup by the method of molecular-beam epitaxy. Combined studies of the obtained samples were performed by the method of secondary-ion mass spectrometry, by measurements of X-ray diffraction, and using a transmission electron microscope. The heterostructures under study with a doping impurity concentration amounting to 0.5 single layers are elastically stressed and demonstrate planar clearly defined interfaces without visible extended or point defects. A method for visualization of the distribution of the manganese concentration in the three-dimensional GaAs matrix in the vicinity of a quantum well is suggested. According to experimental results, there is a probability for manganese diffusion into the GaAs/InGaAs/GaAs quantum well when the critical thickness of the GaAs buffer layer is decreased to a value smaller than 3 nm.

36 MATERIALS SCIENCE↗

Characterization of Filters Loaded With Reactor Strontium Carbonate - 13203

A collection of three highly radioactive filters containing reactor strontium carbonate were being prepared for disposal. All three filters were approximately characterized at the time of manufacture by gravimetric methods. The first filter had been partially emptied, and the quantity of residual activity was uncertain. Dose rate to activity modeling using the Monte-Carlo N Particle (MCNP) code was selected to confirm the gravimetric characterization of the full filters, and to fully characterize the partially emptied filter. Although dose rate to activity modeling using MCNP is a common technique, it is not often used for Bremsstrahlung-dominant materials such as reactor strontium. As a result, different MCNP modeling options were compared to determine the optimum approach. This comparison indicated that the accuracy of the results were heavily dependent on the MCNP modeling details and the location of the dose rate measurement point. The optimum model utilized a photon spectrum generated by the Oak Ridge Isotope Generation and Depletion (ORIGEN) code and dose rates measured at 30 cm. Results from the optimum model agreed with the gravimetric estimates within 15%. It was demonstrated that dose rate to activity modeling can be successful for Bremsstrahlung-dominant radioactive materials. However, the degree of success is heavily dependent on the choice of modeling techniques. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Comparison of navigator-gated and breath-held image acquisition techniques for multi-echo quantitative dixon imaging of the liver in children and young adults

Purpose: Acquired over a breath hold, multi-echo Dixon (mDixon) magnetic resonance imaging (MRI) of the liver can be used to quantify proton density fat fraction (PDFF) and iron-related signal decay. However, young, obese, and co-morbid patients may have limited breath holding capacity and could benefit from a motion-robust mDixon acquisition. The purpose of this study was to compare hepatic PDFF and R2* values between navigator-gated and breath-held mDixon MRI acquisition techniques in children and young adults with suspected liver disease. Materials and methods: This retrospective study was institutional review board-approved with a waiver of informed consent. Patients who underwent liver MRI with breath-held and navigator-gated mDixon sequences between January 2017 and July 2018 were included. One reviewer, blinded to sequence, measured PDFF and R2* on four images from each sequence. Another blinded reviewer graded respiratory motion (5-point Likert scale). Pearson correlation (r), Lin’s concordance coefficients (r{sub c}), and Bland–Altman analyses were used to assess agreement between techniques. Frequency of clinically limiting motion (score ≥ 3) was compared with Fisher’s exact test. Results: Forty-two patients were included (15 female, 27 male; mean age: 15.7 ± 4.6 years). Mean PDFF and R2* were 16.6 ± 13.1% and 29.3 ± 4.7 s{sup −1} (breath-held) versus 17.0 ± 13.2% and 29.6 ± 5.2 s{sup −1} (navigator-gated). PDFF agreed almost perfectly between sequences (r{sub c} = 0.997, 95% CI 0.994–0.998; mean bias: 0.3%; 95% limits of agreement: − 2.4 to +1.7%), while R2* values correlated very strongly but with poor agreement (r = 0.837, r{sub c} = 0.832, 95% CI 0.716–0.910). Navigator-gated images exhibited significantly higher frequency of clinically limiting respiratory motion (88% vs. 48%, p = 0.0001). Conclusion: Despite greater respiratory motion artifact, a free-breathing navigator-gated mDixon sequence produces PDFF values with almost perfect agreement to a breath-held sequence.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Dose-Volume Histogram Parameters and Late Side Effects in Magnetic Resonance Image-Guided Adaptive Cervical Cancer Brachytherapy

Purpose: To evaluate the predictive value of dose-volume histogram (DVH) parameters for late side effects of the rectum, sigmoid colon, and bladder in image-guided brachytherapy for cervix cancer patients. Methods and Materials: A total of 141 patients received external-beam radiotherapy and image-guided brachytherapy with or without chemotherapy. The DVH parameters for the most exposed 2, 1, and 0.1 cm{sup 3} (D{sub 2cc}, D{sub 1cc}, and D{sub 0.1cc}) of the rectum, sigmoid, and bladder, as well as International Commission on Radiation Units and Measurements point doses (D{sub ICRU}) were computed. Total doses were converted to equivalent doses in 2 Gy by applying the linear-quadratic model ({alpha}/{beta} = 3 Gy). Late side effects were prospectively assessed using the Late Effects in Normal Tissues-Subjective, Objective, Management and Analytic score. The following patient groups were defined: Group 1: no side effects (Grade 0); Group 2: side effects (Grade 1-4); Group 3: minor side effects (Grade 0-1); and Group 4: major side effects (Grade 2-4). Results: The median follow-up was 51 months. The overall 5-year actuarial side effect rates were 12% for rectum, 3% for sigmoid, and 23% for bladder. The mean total D{sub 2cc} were 65 {+-} 12 Gy for rectum, 62 {+-} 12 Gy for sigmoid, and 95 {+-} 22 Gy for bladder. For rectum, statistically significant differences were observed between Groups 1 and 2 in all DVH parameters and D{sub ICRU}. Between Groups 3 and 4, no difference was observed for D{sub 0.1cc.} For sigmoid, significant differences were observed for D{sub 2cc} and D{sub 1cc}, but not for D{sub 0.1cc} in all groups. For bladder, significant differences were observed for all DVH parameters only comparing Groups 3 and 4. No differences were observed for D{sub ICRU}. Conclusions: The parameters D{sub 2cc} and D{sub 1cc} have a good predictive value for rectal toxicity. For sigmoid, no prediction could be postulated because of limited data. In bladder, DVH parameters were predictive only for major toxicity.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Local Setup Reproducibility of the Spinal Column When Using Intensity-Modulated Radiation Therapy for Craniospinal Irradiation With Patient in Supine Position

Purpose: To evaluate local positioning errors of the lumbar spine during fractionated intensity-modulated radiotherapy of patients treated with craniospinal irradiation and to assess the impact of rotational error correction on these uncertainties for one patient setup correction strategy. Methods and Materials: 8 patients (6 adults, 2 children) treated with helical tomotherapy for craniospinal irradiation were retrospectively chosen for this analysis. Patients were immobilized with a deep-drawn Aquaplast head mask. Additionally to daily megavoltage control computed tomography scans of the skull, once-a-week positioning of the lumbar spine was assessed. Therefore, patient setup was corrected by a target point correction, derived from a registration of the patient's skull. The residual positioning variations of the lumbar spine were evaluated applying a rigid-registration algorithm. The impact of different rotational error corrections was simulated. Results: After target point correction, residual local positioning errors of the lumbar spine varied considerably. Craniocaudal axis rotational error correction did not improve or deteriorate these translational errors, whereas simulation of a rotational error correction of the right-left and anterior-posterior axis increased these errors by a factor of 2 to 3. Conclusion: The patient fixation used allows for deformations between the patient's skull and spine. Therefore, for the setup correction strategy evaluated in this study, generous margins for the lumbar spinal target volume are needed to prevent a local geographic miss. With any applied correction strategy, it needs to be evaluated whether or not a rotational error correction is beneficial.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Computational Modeling of Micrometastatic Breast Cancer Radiation Dose Response

Purpose: Prophylactic cranial irradiation (PCI) involves giving radiation to the entire brain with the goals of reducing the incidence of brain metastasis and improving overall survival. Experimentally, we have demonstrated that PCI prevents brain metastases in a breast cancer mouse model. We developed a computational model to expand on and aid in the interpretation of our experimental results. Methods and Materials: MATLAB was used to develop a computational model of brain metastasis and PCI in mice. Model input parameters were optimized such that the model output would match the experimental number of metastases per mouse from the unirradiated group. An independent in vivo–limiting dilution experiment was performed to validate the model. The effect of whole brain irradiation at different measurement points after tumor cells were injected was evaluated in terms of the incidence, number of metastases, and tumor burden and was then compared with the corresponding experimental data. Results: In the optimized model, the correlation between the number of metastases per mouse and the experimental fits was >95. Our attempt to validate the model with a limiting dilution assay produced 99.9% correlation with respect to the incidence of metastases. The model accurately predicted the effect of whole-brain irradiation given 3 weeks after cell injection but substantially underestimated its effect when delivered 5 days after cell injection. The model further demonstrated that delaying whole-brain irradiation until the development of gross disease introduces a dose threshold that must be reached before a reduction in incidence can be realized. Conclusions: Our computational model of mouse brain metastasis and PCI correlated strongly with our experiments with unirradiated mice. The results further suggest that early treatment of subclinical disease is more effective than irradiating established disease.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Main and Satellite Features in the Ni 2p XPS of NiO

The origin and assignment of the complex main and satellite XPS features of the cations in ionic compounds has been the subject of extensive theoretical studies using different methods. There is agreement that within a molecular orbital model one needs to take into account different types of configurations. Specifically, those where a core electron is removed but no other configuration changes are made and those where in addition to ionization there are also shake or charge transfer changes to the ionic configuration. However, there are strong disagreements about the assignment of XPS features to these configurations. The present work is directed toward resolving the origin of main and satellite features for the Ni 2p XPS of NiO based on ab initio molecular orbital wavefunctions for a cluster model of NiO. A major problem in earlier ab initio XPS studies of ionic compounds has been the use of a common set of orbitals that was not able to properly describe all the ionic configurations that contribute to the full XPS spectra. This is resolved in the present work by using orbitals that are optimized for averages of the occupations of the different configurations that contribute to the XPS. The approach of using State Averaged orbitals is validated through comparisons between different averages and through use of higher order excitations in the wavefunctions for the ionic states. It represents a major extension of our earlier work on the main and satellite features of the Fe 2p XPS of Fe 2 O 3 and proves the reliability and the generality of the assignments of the character and origin of the different features of the XPS obtained with orbitals optimized for State Averages. These molecular orbital methods permit the characterization of the ionic states in terms of the importance of shake excitations and of the coupling of ionization of 2p 1/2 and 2p 3/2 spin-orbit split sub shells. Further, the work lays the foundation for definitive assignments of the character of main and satellite XPS features and points to their origin in the electronic structure of the material.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Maximum Entropy Theory of Multiscale Coarse-Graining via Matching Thermodynamic Forces: Application to a Molecular Crystal (TATB)

The MSCG/FM (multiscale coarse-graining via force-matching) approach is an efficient supervised machine learning method to develop microscopically informed coarse-grained (CG) models. Here we present a theory based on the principle of maximum entropy (PME) enveloping the existing MSCG/FM approaches. This theory views the MSCG/FM method as a special case of matching the thermodynamic forces from the extended ensemble described by the set of thermodynamic (relevant) system coordinates. This set may include CG coordinates, the stress tensor, applied external fields, and so forth, and may be characterized by nonequilibrium conditions. Following the presentation of the theory, we discuss the consistent matching of both bonded and nonbonded interactions. The proposed PME formulation is used as a starting point to extend the MSCG/FM method to the constant strain ensemble, which together with the explicit matching of the bonded forces is better suited for coarse-graining anisotropic media at a submolecular resolution. The theory is demonstrated by performing the fine coarse-graining of crystalline 1,3,5-triamino-2,4,6-trinitrobenzene (TATB), a well-known insensitive molecular energetic material, which exhibits highly anisotropic mechanical properties.

1,3,5-triamino-2,4,6-trinitrobenzene↗

Advances in phosphor two-color ratio method thermography for full-field surface temperature measurements

We report thermographic phosphors can be employed for optical sensing of surface, gas phase, and bulk material temperatures through different strategies including the time-decay method, time-integrated method, and frequency-domain method. We focus on the time-integrated method, also known as the ratio method, as it can be more practical in many situations. This work advances the ratio method using two machine vision cameras with CMOS detectors for full-field temperature measurements of a solid surface. A phosphor calibration coupon is fabricated using aerosol deposition and employed for in situ determination of the temperature-versus-intensity ratio relationship. Algorithms from digital image correlation are employed to determine the stereoscopic imaging system intrinsic and extrinsic parameters, and accurately register material points on the sample to subpixel locations in each image with 0.07 px or better accuracy. Detector nonlinearity is carefully characterized and corrected. Temperature-dependent, spatial non-uniformity of the full-field intensity ratio—posited to be caused by a blue-shift effect of the bandpass filter for non-collimated light and/or a wavelength-dependent transmission efficiency of the lens—is assessed and treated for cases where a standard flat-field correction fails to correct the non-uniformity. In sum, pixel-wise calibration curves relating the computed intensity ratio to temperature in the range of T = 300–430 K are generated, with an embedded error of less than 3 K. This work offers a full calibration methodology and several improvements on two-color phosphor thermography, opening the door for full-field temperature measurements in dynamic tests with deforming test articles.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗