Search NASA⌕ Search

SEARCH · Search NASA

Results for “Operating Experience”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,423 records · Page 79

Development progress of the Materials Analysis and Particle Probe

The Materials Analysis and Particle Probe (MAPP) is a compact in vacuo surface science diagnostic, designed to provide in situ surface characterization of plasma facing components in a tokamak environment. MAPP has been implemented for operation on the Lithium Tokamak Experiment at Princeton Plasma Physics Laboratory (PPPL), where all control and analysis systems are currently under development for full remote operation. Control systems include vacuum management, instrument power, and translational/rotational probe drive. Analysis systems include onboard Langmuir probes and all components required for x-ray photoelectron spectroscopy, low-energy ion scattering spectroscopy, direct recoil spectroscopy, and thermal desorption spectroscopy surface analysis techniques.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Designing and optimizing highly efficient grating for high-brightness laser based on spectral beam combining

A highly efficient nano-periodical grating is theoretically investigated for spectral beam combining (SBC) and is experimentally implemented for attaining high-brightness laser from a diode laser array. The rigorous coupled-wave analysis with the S matrix method is employed to optimize the parameters of the grating. According the optimized parameters, the grating is fabricated and plays a key role in SBC cavity. The diffraction efficiency of this grating is optimized to 95% for the output laser which is emitted from the diode laser array. The beam parameter product of 3.8 mm mrad of the diode laser array after SBC is achieved at the output power of 46.3 W. The optical-to-optical efficiency of SBC cavity is measured to be 93.5% at the maximum operating current in the experiment.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Development of a scanning transmission x-ray microscope for the beamline P04 at PETRA III DESY

We present a scanning transmission x-ray microscope (STXM) built on top of our existing modular platform for high resolution imaging experiments. This platform consists of up to three separate vacuum chambers and custom designed piezo stages. These piezo stages are able to move precisely in x-, y- and z-direction, this makes it possible to adjust the components for different imaging modes. During recent experiments the endstation was operated mainly as a transmission x-ray microscope (TXM) [1, 2].

43 PARTICLE ACCELERATORS↗

Development of sample exchange robot PAM-HC for beamline BL-1A at the photon factory

A macromolecular crystallography beamline, BL-1A, has been built at the Photon Factory (PF) for low energy experiments and has been operational since 2010. We have installed a sample exchange robot, PAM (PF Automated Mounting system), similar to other macromolecular crystallography beamlines. However, following the installation of a helium chamber to reduce the absorption of the diffraction signal by air, we developed a new sample exchange robot to replace PAM. The new robot, named PAM-HC (Helium Chamber), is designed with the goal of minimizing leakage of helium gas from the chamber. Here, the PAM-HC hardware and the flow of its movement are described. Furthermore, measurements of temperature changes during sample exchange are presented in this paper.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Modifications to the synthetic aperture microwave imaging diagnostic

The synthetic aperture microwave imaging diagnostic has been operating on the MAST experiment since 2011. It has provided the first 2D images of B-X-O mode conversion windows and showed the feasibility of conducting 2D Doppler back-scattering experiments. The diagnostic heavily relies on field programmable gate arrays to conduct its work. Recent successes and newly gained experience with the diagnostic have led us to modify it. The enhancements will enable pitch angle profile measurements, O and X mode separation, and the continuous acquisition of 2D DBS data. Finally, the diagnostic has also been installed on the NSTX-U and is acquiring data since May 2016.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Application of IR imaging for free-surface velocity measurement in liquid-metal systems

Measuring free-surface, liquid-metal flow velocity is challenging to do in a reliable and accurate manner. This paper presents a non-invasive, easily calibrated method of measuring the surface velocities of open-channel liquid-metal flows using an IR camera. Unlike other spatially limited methods, this IR camera particle tracking technique provides full field-of-view data that can be used to better understand open-channel flows and determine surface boundary conditions. Lastly, this method could be implemented and automated for a wide range of liquid-metal experiments, even if they operate at high-temperatures or within strong magnetic fields.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

The dual advanced ion simultaneous implantation experiment (DAISIE) for testing plasma-facing materials

A novel dual ion beam experimental facility, the Dual Advanced Ion Simultaneous Implantation Experiment (DAISIE), has been constructed at the University of Wisconsin-Madison Inertial Electrostatic Confinement laboratory for implanting candidate plasma-facing components of multiple ion species. DAISIE is capable of implanting ions at energies from 10 kV to 50 kV, ion currents of 10 µA–950 µA, corresponding to steady-state ion fluxes of 1 × 10 14 cm –2 s –1 to 1 × 10 16 cm –2 s –1 , incidence angles of 55°, and surface temperatures of at least 1100 °C. Improvements to the sample current and sample temperature measurement and control systems over those used in prior UW-IEC experiments have been made. Likewise, optical measurements of the spot size of the beam on samples in DAISIE are in agreement with existing measurements of the ion beam and spot size in previous UW-IEC experiments. Dual-beam operation has been validated with helium-deuterium ion implantations in tungsten surfaces.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

457-nm radiation source based on a diode laser for precision spectroscopy of magnesium atoms

We report on the development of a highly stable source of 457-nm radiation based on a diode laser and a tapered amplifier operating in a double-pass scheme. The diode laser frequency was stabilised by a high-Q reference Fabry – Perot interferometer and doubled in a PPSLT nonlinear crystal placed in an enhancement cavity. At a maximum output power of 200 mW at a wavelength of 457 nm, the laser linewidth was less than 5 kHz. The radiation source operation was demonstrated in experiments on precision spectroscopy of cold magnesium atoms in a magneto-optical trap. (lasers)

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Gamma-ray constraints on effective interactions of the dark matter

Using an effective interaction approach to describe the interactions between the dark matter particle and the light degrees of freedom of the standard model, we calculate the gamma-ray flux due to the annihilation of the dark matter into quarks, followed by fragmentation into neutral pions which subsequently decay into photons. By comparison to the mid-latitude data released from the Fermi-LAT experiment, we obtain useful constraints on the size of the effective interactions and they are found to be comparable to those deduced from collider, gamma-ray line and anti-matter search experiments. However, the two operators induced by scalar and vector exchange among fermionic dark matter and light quarks that contribute to spin-independent cross sections are constrained more stringently by the recent XENON100 data.

79 ASTRONOMY AND ASTROPHYSICS↗

First divertor physics studies in Wendelstein 7-X

The Wendelstein 7-X (W7-X) optimized stellarator fusion experiment, which went into operation in 2015, has been operating since 2017 with an un-cooled modular graphite divertor. This allowed first divertor physics studies to be performed at pulse energies up to 80 MJ, as opposed to 4 MJ in the first operation phase, where five inboard limiters were installed instead of a divertor. This, and a number of other upgrades to the device capabilities, allowed extension into regimes of higher plasma density, heating power, and performance overall, e.g. setting a new stellarator world record triple product. The paper focuses on the first physics studies of how the island divertor works. The plasma heat loads arrive to a very high degree on the divertor plates, with only minor heat loads seen on other components, in particular baffle structures built in to aid neutral compression. The strike line shapes and locations change significantly from one magnetic configuration to another, in very much the same way that codes had predicted they would. Strike-line widths are as large as 10 cm, and the wetted areas also large, up to about 1.5 m 2 , which bodes well for future operation phases. Peak local heat loads onto the divertor were in general benign and project below the 10 MW m –2 limit of the future water-cooled divertor when operated with 10 MW of heating power, with the exception of low-density attached operation in the high-iota configuration. We report the most notable result was the complete (in all 10 divertor units) heat-flux detachment obtained at high-density operation in hydrogen.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Development of an integrated core–edge scenario using the super H-mode

An optimized pedestal regime called the super-H (SH) mode is leveraged to couple a fusion relevant core plasma with a high density scrape-off layer appropriate for realistic reactor power exhaust solutions. Recent DIII-D experiments have expanded the operating space of the SH regime using advanced control algorithms and investigated optimization of impurity seeding, deuterium gas puffing, and 3D magnetic perturbations. Simultaneous real-time control of the pedestal density and radiated power with in-vessel coils and nitrogen seeding enable optimal coupled divertor and pedestal conditions. Four case studies are analysed with varied levels of radiated power in the divertor volume ranging from 0 (no seeding) to 8.5 MW radiated from carbon and nitrogen emission. Plasmas with a 4.5 MW radiated power target establish a radiative mantle, leading to divertor temperatures of ~16 eV while maintaining SH-mode, and with only marginal impact on the pedestal and core performance. Increased levels of N 2 seeding with a 7.5 MW radiated power target facilitate detachment onset and divertor temperatures <5 eV, with no degradation in stored energy and the operational point remaining inside the SH-mode channel for $ > 2.5{\tau }_{\text{E}}$. Finally, a 8.5 MW radiated power target leads to partial detachment, which is so far associated with the loss of access to SH-mode pedestal conditions.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Reversed magnetic shear scenario development in NSTX-U using TRANSP

Abstract Understanding and control of electron thermal transport is a critical point of research in magnetic fusion experiments. Previous experiments have shown that operation with reversed magnetic shear (RMS) can suppress electron thermal transport, resulting in the generation of internal transport barriers (ITBs), with the location of the ITB correlated with the location of minimum magnetic shear. The recent upgrades to NSTX—increased magnetic field up to 1 T, increased plasma current up to 2 MA, 2nd neutral beam—present an increased operating space in which to explore electron thermal transport in RMS plasmas. Utilizing TRANSP, we have developed operating scenarios by which to generate RMS in NSTX-U. The results suggest that RMS in NSTX-U can be generated through fast current ramp and early beam injection into a large plasma volume. This is very similar to the procedure that was followed in both TFTR and NSTX to generate RMS. Sustainment of RMS, disregarding non-( q min = 1) MHD events, requires maintaining a large plasma volume, and increasing the core T e , either via increased plasma current and/or adding heating power. Using this procedure, RMS was sustained for ∼1 s, with q min > 1 for that period.

Galante, M. E. (ORCID:0009000098149425)↗

DAQExpert - An expert system to increase CMS data-taking efficiency

The efficiency of the Data Acquisition (DAQ) of the Compact Muon Solenoid (CMS) experiment for LHC Run 2 is constantly being improved. A significant factor affecting the data taking efficiency is the experience of the DAQ operator. One of the main responsibilities of the DAQ operator is to carry out the proper recovery procedure in case of failure of data-taking. At the start of Run 2, understanding the problem and finding the right remedy could take a considerable amount of time (up to many minutes). Operators heavily relied on the support of on-call experts, also outside working hours. Wrong decisions due to time pressure sometimes lead to an additional overhead in recovery time. To increase the efficiency of CMS data-taking we developed a new expert system, the DAQExpert, which provides shifters with optimal recovery suggestions instantly when a failure occurs. DAQExpert is a web application analyzing frequently updating monitoring data from all DAQ components and identifying problems based on expert knowledge expressed in small, independent logic-modules written in Java. Its results are presented in real-time in the control room via a web-based GUI and a sound-system in a form of short description of the current failure, and steps to recover.

Andre, J. M.↗

Identification of heavy-flavour jets with the CMS detector in pp collisions at 13 TeV

Many measurements and searches for physics beyond the standard model at the LHC rely on the efficient identification of heavy-flavour jets, i.e. jets originating from bottom or charm quarks. In this paper, the discriminating variables and the algorithms used for heavy-flavour jet identification during the first years of operation of the CMS experiment in proton-proton collisions at a centre-of-mass energy of 13 TeV, are presented. Heavy-flavour jet identification algorithms have been improved compared to those used previously at centre-of-mass energies of 7 and 8 TeV. For jets with transverse momenta in the range expected in simulated events, these new developments result in an efficiency of 68% for the correct identification of a b jet for a probability of 1% of misidentifying a light-flavour jet. The improvement in relative efficiency at this misidentification probability is about 15%, compared to previous CMS algorithms. In addition, for the first time algorithms have been developed to identify jets containing two b hadrons in Lorentz-boosted event topologies, as well as to tag c jets. The large data sample recorded in 2016 at a centre-of-mass energy of 13 TeV has also allowed the development of new methods to measure the efficiency and misidentification probability of heavy-flavour jet identification algorithms. The b jet identification efficiency is measured with a precision of a few per cent at moderate jet transverse momenta (between 30 and 300 GeV) and about 5% at the highest jet transverse momenta (between 500 and 1000 GeV).

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Selection of the silicon sensor thickness for the Phase-2 upgrade of the CMS Outer Tracker

During the operation of the CMS experiment at the High-Luminosity LHC the silicon sensors of the Phase-2 Outer Tracker will be exposed to radiation levels that could potentially deteriorate their performance. Previous studies had determined that planar float zone silicon with n-doped strips on a p-doped substrate was preferred over p-doped strips on an n-doped substrate. The last step in evaluating the optimal design for the mass production of about 200 m$^{2}$ of silicon sensors was to compare sensors of baseline thickness (about 300 μm) to thinned sensors (about 240 μm), which promised several benefits at high radiation levels because of the higher electric fields at the same bias voltage. This study provides a direct comparison of these two thicknesses in terms of sensor characteristics as well as charge collection and hit efficiency for fluences up to 1.5 × 10$^{15}$ n$_{eq}$/cm$^{2}$. The measurement results demonstrate that sensors with about 300 μm thickness will ensure excellent tracking performance even at the highest considered fluence levels expected for the Phase-2 Outer Tracker.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Optimizing spin dressing sensitivity for the nEDMSF experiment

nEDMSF aims to measure the neutron electric dipole moment (d n ) with unprecedented precision. In this paper we explore the experiment's sensitivity when operating with an implementation of the critical dressing method in which the angle between the neutron and Helium-3 spins (ϕ 3n ) is subjected to a square modulation by an amount ϕ d (the “dressing angle”). Several parameters can be tuned to optimize sensitivity. We find roughly 10% improvement over a previous estimate, resulting primarily from the addition of a waiting period between the π/2 pulse that initiates d n -driven ϕ 3n growth and the start of ϕ3n modulation. We find negligible further improvement by allowing ϕ d to vary continuously over the course of a run, and no degradation resulting from the addition of an in situ background measurement into each ϕ3n modulation sequence. A complete simulation confirms a 300 live-day sensitivity ofσ = 1.45×10 -28 e ·cm. At this level of sensitivity, σ ϕ3n0 = 1 mrad precision on the initial n/ 3 He angle difference is not negligible.

47 OTHER INSTRUMENTATION↗

Quantum state engineering with flux-biased Josephson phase qubits by rapid adiabatic passages

In this article, the scheme of quantum computing based on the Stark-chirped rapid adiabatic passage (SCRAP) technique [L. F. Wei, J. R. Johansson, L. X. Cen, S. Ashhab, and F. Nori, Phys. Rev. Lett. 100, 113601 (2008)] is extensively applied to implement quantum state manipulations in flux-biased Josephson phase qubits. The broken-parity symmetries of bound states in flux-biased Josephson junctions are utilized to conveniently generate the desirable Stark shifts. Then, assisted by various transition pulses, universal quantum logic gates as well as arbitrary quantum state preparations can be implemented. Compared with the usual {pi}-pulse operations widely used in experiments, the adiabatic population passages proposed here are insensitive to the details of the applied pulses and thus the desirable population transfers can be satisfyingly implemented. The experimental feasibility of the proposal is also discussed.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Towards an Open (Data) Science Analytics-Hub for Reproducible Multi-Model Climate Analysis at Scale

Open Science is key to future scientific research and promotes a deep transformation in the whole scientific research process encouraging the adoption of transparent and collaborative scientific approaches aimed at knowledge sharing. Open Science is increasingly gaining attention in the current and future research agenda worldwide. To effectively address Open Science goals, besides Open Access to results and data, it is also paramount to provide tools or environments to support the whole research process, in particular the design, execution and sharing of transparent and reproducible experiments, including data provenance (or lineage) tracking. This work introduces the Climate Analytics-Hub, a new component on top of the Earth System Grid Federation (ESGF), which joins big data approaches and parallel computing paradigms to provide an Open Science environment for reproducible multi-model climate change data analytics experiments at scale. An operational implementation has been set up at the SuperComputing Centre of the Euro- Mediterranean Center on Climate Change, with the main goal of becoming a reference Open Science hub in the climate community regarding the multi-model analysis based on the Coupled Model Intercomparison Project (CMIP).

analytics-hub↗