Search NASA⌕ Search

SEARCH · Search NASA

Results for “Operational Amplifier”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,423 records · Page 79

Development of a green laser cavity for precision Compton polarimetery in Jefferson Lab Hall A

Many experiments at Jefferson Lab require good knowledge of the polarization of the electron beam. The Pb Radius Experiment (PREx) demands polarization measurement of a lower energy (1.0 GeV) electron beam at 1.0 % accuracy, which can not be achieved by the infra-red (1064 nm) laser Compton polarimeter presently operating in Hall A. Therefore a green laser (CW, 532 nm) based Fabry-Pe´rot cavity for upgraded high precision Compton Polarimetry has been proposed and under development. The system used as a high energy polarized photon target for measuring the polarization of a low- to high-energy (1.0 GeV ? 11.0 GeV) electron beam in a nondestructive manner. Our goal is to amplify a low power laser beam to achieve 1.5 kW of intra cavity power to improve signal to noise ratio of the polarimeter. We locked our test cavity to a frequency doubled Nd:YAG tunable narrow linewidth laser using the Pound-Drever-Hall (PDH) technique. The recent progress and future plan of this project will be presented.

Nanda, Sirish↗

Progress on Gyrotrons for ITER and Future Fusion Reactors

The prototype of the Japan 170 GHz ITER gyrotron holds the energy and efficiency world record of 2.88 GJ (0.8 MW, 3600 s, 57%) with 55% efficiency at 1 MW, 800 s, whereas the Russian 170 GHz ITER prototype tube achieved 0.83 MW with a pulse duration of 203 s at 48% efficiency and 1 MW at 116 s and 52%. The record parameters of the European megawatt-class 140 GHz gyrotron for the Stellarator Wendelstein W7-X are: 0.92 MW output power at 1800 s pulse duration, almost 45% efficiency and 97.5% Gaussian mode purity. All these gyrotrons employ a cylindrical cavity, a quasi-optical output coupler, a synthetic diamond window and a single-stage depressed collector (SDC) for energy recovery. In coaxial cavities the existence of the longitudinally corrugated inner conductor reduces the problems of mode competition and limiting current, thus allowing one to use even higher order modes with lower Ohmic attenuation than in cylindrical cavities. Synthetic diamond windows with a transmission capability of 2 MW, continuous wave (CW) are feasible. In order to keep the number of the required gyrotrons and magnets as low as possible, to reduce the costs of the ITER 26 MW, 170 GHz ECRH system and to allow compact upper launchers for plasma stabilization, 2 MW mm-wave power per gyrotron tube is desirable. The FZK pre-prototype tube for an EU 170 GHz, 2 MW ITER gyrotron has achieved 1.8 MW at 28% efficiency (without depressed collector). Design studies for a 4 MW 170 GHz coaxial-cavity gyrotron with two synthetic diamond output windows and two 2 MW mm-wave output beams for future fusion reactors are currently being performed at FZK. The availability of sources with fast frequency tunability (several GHz s{sup -1}, tuning in 1.5-2.5% steps for about ten different frequencies) would permit the use of a simple, fixed, non-steerable mirror antenna for local current drive (ECCD) experiments and plasma stabilization. GYCOM in Russia develops in collaboration with IPP Garching and FZK an industrial, frequency-tunable 1 MW gyrotron with almost 50% efficiency (SDC) for ASDEX Upgrade. A four-frequency tube (105, 117, 127 and 140 GHz) delivered in 10 s pulses 0.7 MW at 105 GHz and 0.9 MW at 140 GHz. After the installation of a diamond Brewster window, the GYCOM group will operate this gyrotron also at the two intermediate frequencies.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

A method for suppression of spurious fundamental-harmonic waves in gyrotrons operating at the second cyclotron harmonic

A typical problem of gyrotrons operating at high harmonics of the electron cyclotron frequency is the suppression of parasitic near-cutoff waves excited at lower harmonics. In this paper, a method for a significant improvement of the selectivity of the second-harmonic gyrotrons is proposed. This method is based on the use of quasi-regular cavities with short irregularities, which provide different effects on the process of excitation of the operating second-harmonic wave and the spurious fundamental-harmonic wave by the electron beam.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Solution-Processed Temperature-Adaptive Radiative Paint as a Thermal Imaging Sensitizer

Thermography detects mid-infrared radiation from surfaces based on the Stefan-Boltzmann law, mapping surface temperatures and potentially revealing subsurface thermal activity. Recent developments offer an alternative strategy to traditional camera-based improvements: a thermal imaging sensitizer (TIS) coating whose emissivity increases sharply with local temperature, amplifying small thermal variations into high-contrast signals. Existing TIS structures are nanofabricated solid membranes and face significant challenges in fabrication complexity. Here, in this study, we present a solution-processed, liquid form of TIS, termed temperature-adaptive radiative paint (TARP), to address these limitations. TARP offers drastically reduced fabrication costs, scalability to large areas, applicability to curved surfaces, and an extended operating temperature range, while maintaining the function of temperature amplification. Application of TARP enhances small temperature contrast by more than 3 times, substantially improving ambient thermography and enabling broader applications such as detection of structural defects and hot spots in electronic components.

paint↗

Microwave tunable laser source: A stable, precision tunable heterodyne local oscillator

The development and capabilities of a tunable laser source utilizing a wideband electro-optic modulator and a CO2 laser are described. The precision tunability and high stability of the device are demonstrated with examples of laboratory spectroscopy. Heterodyne measurements are also presented to demonstrate the performance of the laser source as a heterodyne local oscillator. With the use of five CO2 isotope lasers and the 8 to 18 GHz sideband offset tunability of the modulator, calculations indicate that 50 percent spectral coverage in the 9 to 12 micron region is achievable. The wavelength accuracy and stability of this laser source is limited by the CO2 laser and is more than adequate for the measurement of narrow Doppler-broadened line profiles. The room-temperature operating capability and the programmability of the microwave tunable laser source are attractive features for its in-the-field implementation. Although heterodyne measurements indicated some S/N degradation when using the device as a local oscillator, there does not appear to be any fundamental limitation to the heterodyne efficiency of this laser source. Through the use of a lower noise-figure traveling wave tube amplifier and optical matching of the output beam with the photomixer, a substantial increase in the heterodyne S/N is expected.

Sachse, G. W.↗

Challenges and Considerations When Using Hydraulic Modal Shaking in Large-Scale Modal Testing

As test articles become dimensionally larger, more complex, and massive in weight, combined with the need to excite them to higher than traditional levels in order to identify their nonlinear characteristics, modal shakers that can generate significantly higher force levels, have longer stroke lengths, and possess higher velocity limits are required. While large scale modal tests may be performed with electrodynamic modal shakers, hydraulic modal shakers become attractive since they can generate higher force levels at lower unit cost with a smaller spatial footprint. While test engineers familiar with electrodynamic modal shakers are familiar with the challenges of displacement and velocity limits and the relatively mild shaker nonlinear distortion due to amplifier gains and shaker flexure structural geometric nonlinearities, they probably are not as familiar with the unique set of challenges hydraulic modal shakers present. These unique challenges include significant nonlinear distortion in the shaker force, issues with the setup of the hydraulic power supply and the associated hydraulic hosing, velocity limits as they relate to potentially damaging the hydraulic actuator piston, and safety issues with operating high-pressure hydraulic systems. This paper addresses these unique challenges to help the test engineer to better utilize hydraulic modal shakers on large-scale modal tests.

Distortion↗

Challenges and Considerations When Using Hydraulic Modal Shaking in Large-Scale Modal Testing IMAC-XL

As test articles become dimensionally larger, more complex, and massive in weight, combined with the need to excite them to higher than traditional levels in order to identify their nonlinear characteristics, modal shakers that can generate significantly higher force levels, have longer stroke lengths, and possess higher velocity limits are required. While large scale modal tests may be performed with electrodynamic modal shakers, hydraulic modal shakers become attractive since they can generate higher force levels at lower unit cost with a smaller spatial footprint. While test engineers familiar with electrodynamic modal shakers are familiar with the challenges of displacement and velocity limits and the relatively mild shaker nonlinear distortion due to amplifier gains and shaker flexure structural geometric nonlinearities, they probably are not as familiar with the unique set of challenges hydraulic modal shakers present. These unique challenges include significant nonlinear distortion in the shaker force, issues with the setup of the hydraulic power supply and the associated hydraulic hosing, velocity limits as they relate to potentially damaging the hydraulic actuator piston, and safety issues with operating high-pressure hydraulic systems. This paper addresses these unique challenges to help the test engineer to better utilize hydraulic modal shakers on large-scale modal tests.

Distortion↗

Development of 2.05 µm Fiber Lasers for CO2 DIAL Lidar Measuring Martian CO2 and Pressure

The Decadal Survey by the National Academy of Sciences in the United States and NASA’s Science Mission Directorate (SMD) Science Plan both require global CO 2 observations for the Martian atmospheric pressure, dynamics and chemistry. However, there are significant observational gaps in polar regions and during nighttime for global air pressure and CO 2 on Mars. Therefore, recently we proposed a new concept of Martian differential absorption lidar (DIAL) operating in the 2.05 µm CO 2 absorption band for global, including poles, atmospheric CO 2 and pressure observations day and night [1]. Based on the concept, we are awarded to develop 2.05 µm fiber lasers by the NASA Planetary Instrument Concepts for the Advancement of Solar System Observations (PICASSO) Program. The laser is designed to be an all-fiber master oscillator and power amplifier (MOPA) system with laser output of ~3 mJ at a repetition frequency of 2 kHz. The primary master oscillator (PMO) is locked to the center (2.0504280 µm) of the selected CO 2 absorption line. The frequency of a second MO (SMO) is locked to that of PMO. This SMO frequency is adjustable and switched between the online (2.05044156 µm) and offline (2.05050812 µm) wavelengths. The online wavelength is optimally selected so that the CO 2 absorption optical depth (AOD) is ~1.1 at 3 km and the measurement in the low Martian atmosphere has largest signal-to-noise ratio. The online wavelength can also be adjusted to a line slope location where AOD is larger to observe atmospheric pressure at higher altitudes. We will present more detail about this project and instrument development at the conference.

Zhaoyan Liu↗

General Mode Scanning Probe Microscopy

A critical part of SPM measurements is the information transfer from the probe-sample junction to the measurement system. Current information transfer methods heavily compress the information-rich data stream by averaging the data over a time interval, or via heterodyne detection approaches such as lock-in amplifiers and phase-locked loops. As a consequence, highly valuable information at the sub-microsecond time scales or information from frequencies outside the measurement band is lost. We have developed a fundamentally new approach called General Mode (G-mode), where we can capture the complete information stream from the detectors in the microscope. The availability of the complete information allows the microscope operator to analyze the data via information-theory analysis or comprehensive physical models. Furthermore, the complete data stream enables advanced data-driven filtering algorithms, multi-resolution imaging, ultrafast spectroscropic imaging, spatial mapping of multidimensional variability in material properties, etc. Though we applied this approach to scanning probe microscopy, the general philosophy of G-mode can be applied to many other modes of microscopy. G-mode data is captured by completely custom software written in LabVIEW and Matlab. The software generates the waveforms to electrically, thermally, or mechanically excite the SPM probe. It handles real-time communications with the microscope software for operations such as moving the SPM probe position and also controls other instrumentation hardware. The software also controls multiple variants of high-speed data acquisition cards to excite the SPM probe with the excitation waveform and simultaneously measure multiple channels of information from the microscope detectors at sampling rates of 1-100 MHz. The software also saves the raw data to the computer and allows the microscope operator to visualize processed or filtered data during the experiment. The software performs all these features while offering a user-friendly interface.

Somnath, Suhas↗

Understanding Multi-Ion Transport Mechanisms in Bipolar Membranes

Bipolar membranes (BPMs) have the potential to become critical components in electrochemical devices for a variety of electrolysis and electrosynthesis applications. Because they can operate under large pH gradients, BPMs enable favorable environments for electrocatalysis at the individual electrodes. Critical to the implementation of BPMs in these devices is understanding the kinetics of water dissociation that occurs within the BPM as well as the co- and counter-ion crossover through the BPM, which both present significant obstacles to developing efficient and stable BPM-electrolyzers. In this study, a continuum model of multi-ion transport in a BPM is developed and fit to experimental data. Specifically, concentration profiles are determined for all ionic species, and the importance of a water-dissociation catalyst is demonstrated. The model describes internal concentration polarization and co- and counter-ion crossover in BPMs, determining the mode of transport for ions within the BPM and revealing the significance of salt-ion crossover when operated with pH gradients relevant to electrolysis and electrosynthesis. Lastly, a sensitivity analysis reveals that the performance and lifetime of BPMs can be improved substantially by using of thinner dissociation catalysts, managing water transport, modulating the thickness of the individual layers in the BPM to control salt-ion crossover, and increasing the ion-exchange capacity of the ion-exchange layers in order to amplify the water-dissociation kinetics at the interface.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Measurement of amplification and absorption of a THz quantum-cascade metasurface free-space amplifier

An active amplifying metasurface based on a quantum-cascade gain material at 2.7 THz is studied. The metasurface is first evaluated as the active component of an external cavity laser with excellent beam quality and frequency tunability from 2.55–2.8 THz. Amplification and absorption of the metasurface alone are then separately measured at a single frequency using a probe signal from a CO 2 -pumped gas laser operating at 2.743 THz. The metasurface reflectance vs bias is measured and compared with expectations from non-equilibrium Green’s function simulations of the quantum-cascade gain material and FEM simulations of the metasurface reflectance. A peak amplification on the order of 0.3 dB is measured. Design strategies are discussed for increasing single-reflection amplification (upward of 10 dB) and reducing power dissipation. Further increased amplification could be achieved by cascading multiple metasurfaces.

Curwen, Christopher A.↗

Convective overstability in radially stratified accretion disks under thermal relaxation

This paper expands the stability criterion for radially stratified, vertically unstratified accretion disks incorporating thermal relaxation. We find a linear amplification of epicyclic oscillations in these disks that depends on the effective cooling time, i.e., an overstability. The growth rates of the overstability vanish for both extreme cases, e.g., infinite cooling time and instantaneous cooling, i.e., the adiabatic and fully isothermal cases. However, for thermal relaxation times τ on the order of the orbital frequency, τΩ ∼ 1, modes grow at a rate proportional to the square of the Brunt-Väisälä frequency. The overstability is based on epicyclic motions, with the thermal relaxation causing gas to heat while radially displaced inward and cool while radially displaced outward. This causes the gas to have a lower density when moving outward compared to when it moves inward, so it feels the outward-directed pressure force more strongly on that leg of the journey. We suggest the term 'convective overstability' for the phenomenon which has already been studied numerically in the nonlinear regime in the context of amplifying vortices in disks under the name 'subcritical baroclinic instability'. The aim of the present paper is to make clear that vortex formation in three-dimensional disks is not necessarily subcritical, i.e., does not need a finite perturbation, nor is it baroclinic in the sense of geophysical fluid dynamics, which requires on vertical shear. We find that convective overstability is a linear instability that will operate under a wide range of physical conditions for circumstellar disks.

79 ASTRONOMY AND ASTROPHYSICS↗

Applying Space Technology to Enhance Control of an Artificial Arm for Children and Adults With Amputations

The first single function myoelectric prosthetic hand was introduced in the 1960's. This hand was controlled by the electric fields generated by muscle contractions in the residual limb of the amputee user. Electrodes and amplifiers, embedded in the prosthetic socket, measured these electric fields across the skin, which increase in amplitude as the individual contracts their muscle. When the myoelectric signal reached a certain threshold amplitude, the control unit activated a motor which opened or closed a hand-like prosthetic terminal device with a pincher grip. Late in the 1990's, little has changed. Most current myoelectric prostheses still operate in this same, single-function way. To better understand the limitations of the current single-function myoelectric hand and the needs of those who use them, The Institute for Rehabilitation and Research (TIRR), sponsored by the National Institutes of Health (NUH), surveyed approximately 2,500 individuals with upper limb loss [1]. When asked to identify specific features of their current myoelectric prostheses that needed improvement, the survey respondents overwhelmingly identified the lack of wrist and finger movement, as well as poor control capability. However, simply building a mechanism with individual finger and wrist motion is not enough. In the 1960's and 1970's, engineers built a number of more dexterous prosthetic hands. Unfortunately, these were rejected during clinical trials due to a difficult and distracting control interface. The goal of this project, "Applying Space Technology to Enhance Control of an Artificial Arm for Children and Adults with Amputations," was to lay the foundation for a multi-function, intuitive myoelectric control system which requires no conscious thought to move the hand. We built an extensive myoelectric signal database for six motions from ten amputee volunteers, We also tested a control system based on new artificial intelligence techniques on the data from two of these subjects. This data is available to anyone doing myoelectric control research. Its availability is an important contribution to the prosthetics research community, as many researchers do not have access to amputee subjects. Since we collected myoelectric data from subjects' sound arms as well as their residual arms, this database will also prove useful to virtual reality and robotics researchers who want to explore myoelectric-based interfaces between any user and a machine. Currently, one small company (Intelligenta, Inc.) and one university (University of New Brunswick, Canada) are using this myoelectric database under other funding to develop multifunction control systems for prostheses. A prosthetics manufacturer (Liberty Technology, Inc.) is making plans to incorporate the results of their work into an artificial hand capable of several different movements to provide functionality only dreamed of by current myoelectric users. Methods Six adults and four children, all with unilateral, below-elbow amputations served as subjects. Five of the adults (3 male, 2 female, average age 34 years) had amputations due to traumatic injury, while one adult (female, age 32 years) and the four children (3 male, 1 female, average age 13 years) had congenital (i.e. from birth) limb deficiencies.

Atkins, Diane J.↗

Integrated imaging sensor systems with CMOS active pixel sensor technology

This paper discusses common approaches to CMOS APS technology, as well as specific results on the five-wire programmable digital camera-on-a-chip developed at JPL. The paper also reports recent research in the design, operation, and performance of APS imagers for several imager applications.

double sampling↗

Large CMOS imager using hadamard transform based multiplexing

We have developed a concept design for a large (~10k x 10k) CMOS imaging array whose elements are grouped in small subarrays with N pixels in each. The subarrays are code-division multiplexed using the Hadamard Transform (HT) based encoding. The Hadamard code improves the signal-to-noise (SNR) ratio to the reference of the read-out amplifier by a factor of N^1/2. This way of grouping pixels reduces the number of hybridization bumps by N. A single chip layout has been designed and the architecture of the imager has been developed to accommodate the HT base multiplexing into the existing CMOS technology. The imager architecture allows for a trade-off between the speed and the sensitivity. The envisioned imager would operate at a speed >100 fps with the pixel noise < 20 e-. The power dissipation would be ~100 pW/pixe1. The combination of the large format, high speed, high sensitivity and low power dissipation can be very attractive for space reconnaissance applications.

CMOS imager↗

Miniaturized Laser Heterodyne Radiometer (LHR) for Measurements of Greenhouse Gases in the Atmospheric Column

This passive laser heterodyne radiometer (LHR) instrument simultaneously measures multiple trace gases in the atmospheric column including carbon dioxide (CO2) and methane (CH4), and resolves their concentrations at different altitudes. This instrument has been designed to operate in tandem with the passive aerosol sensor currently used in AERONET (an established network of more than 450 ground aerosol monitoring instruments worldwide). Because aerosols induce a radiative effect that influences terrestrial carbon exchange, simultaneous detection of aerosols with these key carbon cycle gases offers a uniquely comprehensive measurement approach. Laser heterodyne radiometry is a technique for detecting weak signals that was adapted from radio receiver technology. In a radio receiver, a weak input signal from a radio antenna is mixed with a stronger local oscillator signal. The mixed signal (beat note, or intermediate frequency) has a frequency equal to the difference between the input signal and the local oscillator. The intermediate frequency is amplified and sent to a detector that extracts the audio from the signal. In the LHR instrument described here, sunlight that has undergone absorption by the trace gas is mixed with laser light at a frequency matched to a trace gas absorption feature in the infrared (IR). Mixing results in a beat signal in the RF (radio frequency) region that can be related to the atmospheric concentration. For a one-second integration, the estimated column sensitivities are 0.1 ppmv for CO2, and <1 ppbv for CH4. In addition to producing a standalone ground measurement product, this instrument could be used to calibrate/validate four Earth observing missions: ASCENDS (Active Sensing of CO2 Emissions over Nights, Days, and Seasons), OCO-2 (Orbiting Carbon Observatory), OCO-3, and GOSAT (Greenhouse gases Observational SATellite). The only network that currently measures CO2 and CH4 in the atmospheric column is TCCON (Total Carbon Column Observing Network), and only two of its 16 operational sites are in the United States. TCCON data is used for validation of GOSAT data, and will be used for OCO-2 validation. While these Fourier-transform spectrometers (FTS) can measure the largest range of trace gases, the network is severely limited due to the high cost and extreme size of these instruments (these occupy small buildings and require personnel for operation). The LHR/AERONET instrument offers a significantly smaller (carry-on luggage size) autonomous instrument that can be incorporated into AERONET s much larger (450 instruments) global network.

Steel, Emily↗

Preamplifier Noise in VLF Receivers

Noise specifications for junction field-effect transistors are presented in different ways depending on the particular semiconductor manufacturer. Arithmetic involved in converting these specifications to equivalent RMS noise in microvolts developed at the preamplifier input terminal is reviewed. These methods were useful for estimating the noise performance of high input impedance preamplifiers used with E-field antennas operating in the range of 1 KHz to 10 MHz. Both the JFET MPF-102 transistor and the COS/MOS CA3600 transistor array provided amplification for VLF receivers where the internally generated noise was well below the atmospheric noise level. The CA3600 transistor array provided better performance because of the more symmetrical complementary MOS transistor transfer characteristics than a single N-type biased JFET transistor. The CMOS amplifier resulted in self-compensating gain characteristics over a very wide temperature range from -55 to +125 C.

Burhans, R. W.↗