Search NASA⌕ Search

SEARCH · Search NASA

Results for “PHASE IMAGING”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,423 records · Page 79

2022 AI Testbed Expeditions Report

By exploiting the coherent properties of a light source, coherent diffraction imaging (CDI) is able to obtain the sample image at a nanoscale resolution using the measured diffraction pattern. Bragg Coherent Diffraction Imaging (BCDI) has become valuable for recovering the displacement and strain field of crystals, providing a valuable tool in material science and solid-state physics. X-ray ptychography is another emerging CDI technique that can produce a high-resolution image of the extended sample and has become popular in many research areas (e.g., materials science, biology, electronics, and optics characterization). CDI including BCDI and ptychography has become an established technique in Synchrotron Facilities including the Advanced Photon Source (APS) and will greatly benefit from the 100x coherent flux increase of the upcoming APS Upgrade (APSU). The current image formation process in CDI employs iterative phase retrieval algorithms, which is a time-consuming and computationally expensive process. Especially after APSU, the traditional iterative methods will not be able to match the experimental data acquisition speed. We employ deep learning (DL) approach to replace the iterative approaches, therefore allowing hundreds of times faster recovery of the object. We developed AutoPhaseNN, a DL-based approach which learns to solve the inverse problem without labeled data. Taking 3D BCDI as a representative technique, AutoPhaseNN has been demonstrated to be one hundred times faster than traditional iterative phase retrieval methods while providing comparable image quality. The current network is trained with 64 x 64 x 64 data size, to achieve higher resolution imaging, we will need to scale the network to input and train/infer 3D arrays of size 256 x 256 x 256 (today) and of size 2560x2560x2560 (APSU). However, the scalability of the network is restricted due to the memory-intensive training process. To perform the training for a 256 x 256 x 256 data size, the required memory exceeds the capacity of the current machine. In this project, we explore using Sambanova system to train the network for the direct data inversion for CDI.

36 MATERIALS SCIENCE↗

Radioablation by Image-Guided (HDR) Brachytherapy and Transarterial Chemoembolization in Hepatocellular Carcinoma: A Randomized Phase II Trial

Background and Aims: The aim of this single-center, open-label phase II study was to assess the efficacy of image-guided high-dose-rate (HDR) brachytherapy (iBT) compared with conventional transarterial embolization (cTACE) in unresectable hepatocellular carcinoma. Methods: Seventy-seven patients were treated after randomization to iBT or cTACE, as single or repeated interventions. Crossover was allowed if clinically indicated. The primary endpoint was time to untreatable progression (TTUP). Eligibility criteria included a Child–Pugh score of ≤ 8 points, absence of portal vein thrombosis (PVT) at the affected liver lobe, and ≤ 4 lesions. Survival was analyzed by using the Cox proportional hazard model with stratification for Barcelona Clinic Liver Cancer (BCLC) stages. Results: Twenty patients were classified as BCLC-A (iBT/cTACE 8/12), 35 as BCLC-B (16/19), and 22 as BCLC-C (13/9). The 1-, 2-, and 3-year TTUP probabilities for iBT compared with cTACE were 67.5% versus 55.2%, 56.0% versus 27.4%, and 29.5% versus 11.0%, respectively, with an adjusted hazard ratio (HR) of 0.49 (95% confidence interval 0.27–0.89; p = 0.019). The 1-, 2-, and 3-year TTPs for iBT versus cTACE were 56.0% versus 28.2%, 23.9% versus 6.3%, and 15.9% versus 6.3%, respectively, with an adjusted HR of 0.49 (0.29–0.85; p = 0.011). The 1-, 2-, and 3-year OS rates were 78.4% versus 67.7%, 62.0% versus 47.3%, and 36.7% versus 27.0%, respectively, with an adjusted HR of 0.62 (0.33–1.16; p = 0.136). Conclusions: This explorative phase II trial showed a superior outcome of iBT compared with cTACE in hepatocellular carcinoma and supports proceeding to a phase III trial.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

NASA Tech Briefs, April 2007

Topics include: Wearable Environmental and Physiological Sensing Unit; Broadband Phase Retrieval for Image-Based Wavefront Sensing; Filter Function for Wavefront Sensing Over a Field of View; Iterative-Transform Phase Retrieval Using Adaptive Diversity; Wavefront Sensing With Switched Lenses for Defocus Diversity; Smooth Phase Interpolated Keying; Maintaining Stability During a Conducted-Ripple EMC Test; Photodiode Preamplifier for Laser Ranging With Weak Signals; Advanced High-Definition Video Cameras; Circuit for Full Charging of Series Lithium-Ion Cells; Analog Nonvolatile Computer Memory Circuits; JavaGenes Molecular Evolution; World Wind 3D Earth Viewing; Lithium Dinitramide as an Additive in Lithium Power Cells; Accounting for Uncertainties in Strengths of SiC MEMS Parts; Ion-Conducting Organic/Inorganic Polymers; MoO3 Cathodes for High-Temperature Lithium Thin-Film Cells; Counterrotating-Shoulder Mechanism for Friction Stir Welding; Strain Gauges Indicate Differential-CTE-Induced Failures; Antibodies Against Three Forms of Urokinase; Understanding and Counteracting Fatigue in Flight Crews; Active Correction of Aberrations of Low-Quality Telescope Optics; Dual-Beam Atom Laser Driven by Spinor Dynamics; Rugged, Tunable Extended-Cavity Diode Laser; Balloon for Long-Duration, High-Altitude Flight at Venus; and Wide-Temperature-Range Integrated Operational Amplifier.

Source record↗

Imaging extended single crystal lattice distortion fields with multi-peak Bragg ptychography

Recent advances in phase-retrieval-based x-ray imaging methods have demonstrated the ability to reconstruct 3D distortion vector fields within a nanocrystal by using coherent diffraction information from multiple crystal Bragg reflections. However, these works do not provide a solution to the challenges encountered in imaging lattice distortions in crystals with significant defect content that result in phase wrapping. Moreover, these methods only apply to isolated crystals smaller than the x-ray illumination, and therefore cannot be used for imaging of distortions in extended crystals. We introduce multi-peak Bragg ptychography which addresses both challenges via an optimization framework that combines stochastic gradient descent and phase unwrapping methods for robust image reconstruction of lattice distortions and defects in extended crystals. Our work uses modern automatic differentiation toolsets so that the method is easy to extend to other settings and easy to implement in high-performance computers. This work is particularly timely given the broad interest in using the increased coherent flux in fourth-generation synchrotrons for innovative material research.

36 MATERIALS SCIENCE↗

The Diamond Beamline I13L for Imaging and Coherence

I13L is the first long beamline at Diamond dedicated to imaging and coherence. Two independent branches will operate in the energy range of 6-30 keV with spatial resolution on the micro- to nano-lengthscale. The Imaging branch is dedicated to imaging and tomography with In-line phase contrast and full-field microscopy on the micron to nano-length scale. Ultimate resolution will be achieved on the Coherence branch at I13L with imaging techniques in the reciprocal space. The experimental stations will be located about 250 m from the source, taking advantage of the coherence properties of the source. The beamline has some outstanding features such as the mini-beta layout of the storage ring's straight section. The optical layout is optimized for beam stability and high optical quality to preserve the coherent radiation. In the experimental stations several methods will be available, starting for the first user with in-line phase contrast imaging on the imaging branch and Coherent X-ray Diffraction (CXRD) on the coherence branch.

43 PARTICLE ACCELERATORS↗

Development of Simultaneous Beta-and-Coincidence-Gamma Imager for Plant Imaging Research

The goal of this project is to develop a novel imaging system that can simultaneously acquire beta and coincidence gamma images of positron sources in thin objects such as leaves of plants. This hybrid imager can be used to measure carbon assimilation in plants quantitatively and in real-time after C-11 labeled carbon-dioxide is administered. A better understanding of carbon assimilation, particularly under the increasingly elevated atmospheric CO 2 level, is extremely critical for plant scientists who study food crop and biofuel production. Phase 1 of this project is focused on the technology development with 3 specific aims: (1) develop a hybrid detector that can detect beta and gamma rays simultaneously; (2) develop an imaging system that can differentiate these two types of radiation and acquire beta and coincidence gamma images in real-time; (3) develop techniques to quantify radiotracer distribution using beta and gamma images. Phase 2 of this project is to apply technologies developed in phase 1 to study plants using positron-emitting radionuclide such as 11 C to study carbon assimilation in biofuel plants.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

SU-F-207-13: Comparison of Four Dimensional Computed Tomography (4D CT) Versus Breath Hold Images to Determine Pulmonary Nodule Elasticity

Purpose: Elasticity may distinguish malignant from benign pulmonary nodules. To compare determining of malignant pulmonary nodule (MPN) elasticity from four dimensional computed tomography (4D CT) images versus inhale/exhale breath-hold CT images. Methods: We analyzed phase 00 and 50 of 4D CT and deep inhale and natural exhale of breath-hold CT images of 30 MPN treated with stereotactic ablative radiotherapy (SABR). The radius of the smallest MPN was 0.3 cm while the biggest one was 2.1 cm. An intensity based deformable image registration (DIR) workflow was applied to the 4D CT and breath-hold images to determine the volumes of the MPNs and a 1 cm ring of surrounding lung tissue (ring) in each state. Next, an elasticity parameter was derived by calculating the ratio of the volume changes of MPN (exhale:inhale or phase50:phase00) to that of a 1 cm ring of lung tissue surrounding the MPN. The proposed formulation of elasticity enables us to compare volume changes of two different MPN in two different locations of lung. Results: The calculated volume ratio of MPNs from 4D CT (phase50:phase00) and breath-hold images (exhale:inhale) was 1.00±0.23 and 0.95±0.11, respectively. It shows the stiffness of MPN and comparably bigger volume changes of MPN in breath-hold images because of the deeper degree of inhalation. The calculated elasticity of MPNs from 4D CT and breath-hold images was 1.12±0.22 and 1.23±0.26, respectively. For five patients who have had two MPN in their lung, calculated elasticity of tumor A and tumor B follows same trend in both 4D CT and breath-hold images. Conclusion: We showed that 4D CT and breath-hold images are comparable in the ability to calculate the elasticity of MPN. This study has been supported by Department of Defense LCRP 2011 #W81XWH-12-1-0286.

60 APPLIED LIFE SCIENCES↗

Imaging of Hydrogel Microsphere Structure and Foreign Body Response Based on Endogenous X-Ray Phase Contrast

Transplantation of functional islets encapsulated in stable biomaterials has the potential to cure Type I diabetes. However, the success of these materials requires the ability to understand their stability in vivo. Imaging techniques that enable monitoring of biomaterial performance are critical to further development in the field. In this study, we demonstrate for the first time that X-ray phase contrast (XPC) imaging techniques enable 3D imaging and evaluation of islet volume, alginate hydrogel structure and local soft tissue response. Islets were encapsulated in alginate systems prepared in methods used in clinical trials and implanted in a rodent omentum pouch model as a treatment for type I diabetes. Microbeads were imaged with XPC prior to implantation and following implantation into an omentum pouch. Islets could be identified within alginate beads and the islet volume quantified. Omental adipose tissue could be distinguished from inflammatory regions resulting from implanted beads. Individual beads and the local encapsulation response were visualized and quantifiable. Measurements were in agreement with histology. The 3D structure of the microbeads could be characterized with XPC and failed beads could also be identified. These results point to the substantial potential of XPC as a tool for imaging biomaterials in small animal models.

59 BASIC BIOLOGICAL SCIENCES↗

Fluid/Fluid Interfacial Areas Measured for Different Non-Wetting/Wetting Fluid Pairs in Natural Porous Media

This study examined the impact of fluid type and grain diameter on the interfacial area between different pairs of non-wetting and wetting fluids in natural porous media. Synchrotron X-ray microtomography was used to obtain high-resolution, three-dimensional images of multi-phase porous media systems. Multiple porous media, comprising a range of physical and geochemical properties, were used in this study. The four pairs of non-wetting/wetting fluids used were dense OIL/water, light OIL/water, air/dense OIL, and air/water. Images were obtained over a broad range of wetting phase saturation and for both wetting phase drainage and imbibition conditions. The results showed that for each fluid pair, the total (capillary + film) interfacial area increased with decreasing wetting fluid saturation. Interfacial areas were similar among all fluid pairs for a given porous medium. They were also similar for drainage and imbibition conditions. The maximum specific interfacial area (A m ) was shown to correlate well with inverse median grain diameter. The physical properties of the porous medium appear to have a greater influence on the magnitude of specific total interfacial area for a given saturation than fluid properties or wetting phase history.

NAPL↗

Clinical Outcomes of Image Guided Adaptive Hypofractionated Weekly Radiation Therapy for Bladder Cancer in Patients Unsuitable for Radical Treatment

Purpose and Objectives: We report on the clinical outcomes of a phase 2 study assessing image guided hypofractionated weekly radiation therapy in bladder cancer patients unsuitable for radical treatment. Methods and Materials: Fifty-five patients with T2-T4aNx-2M0-1 bladder cancer not suitable for cystectomy or daily radiation therapy treatment were recruited. A “plan of the day” radiation therapy approach was used, treating the whole (empty) bladder to 36 Gy in 6 weekly fractions. Acute toxicity was assessed weekly during radiation therapy, at 6 and 12 weeks using the Common Terminology Criteria for Adverse Events version 3.0. Late toxicity was assessed at 6 months and 12 months using Radiation Therapy Oncology Group grading. Cystoscopy was used to assess local control at 3 months. Cumulative incidence function was used to determine local progression at 1 at 2 years. Death without local progression was treated as a competing risk. Overall survival was estimated using the Kaplan-Meier method. Results: Median age was 86 years (range, 68-97 years). Eighty-seven percent of patients completed their prescribed course of radiation therapy. Genitourinary and gastrointestinal grade 3 acute toxicity was seen in 18% (10/55) and 4% (2/55) of patients, respectively. No grade 4 genitourinary or gastrointestinal toxicity was seen. Grade ≥3 late toxicity (any) at 6 and 12 months was seen in 6.5% (2/31) and 4.3% (1/23) of patients, respectively. Local control after radiation therapy was 92% of assessed patients (60% total population). Cumulative incidence of local progression at 1 year and 2 years for all patients was 7% (95% confidence interval [CI] 2%-17%) and 17% (95% CI 8%-29%), respectively. Overall survival at 1 year was 63% (95% CI 48%-74%). Conclusion: Hypofractionated radiation therapy delivered weekly with a plan of the day approach offers good local control with acceptable toxicity in a patient population not suitable for radical bladder treatment.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Measurement and image processing evaluation of surface modifications of dental implants G4 pure titanium created by different techniques

Foreign substances and organic tissue interaction placed into the jaw in order to eliminate tooth loss involves a highly complex process. Many biological reactions take place as well as the biomechanical forces that influence this formation. Osseointegration denotes to the direct structural and functional association between the living bone and the load-bearing artificial implant's surface. Taking into consideration of the requirements in the manufacturing processes of the implants, surface characterizations with high precise measurement techniques are investigated and thus long-term success of dental implant is emphasized on the importance of these processes in this study. In this research, the detailed surface characterization was performed to identify the dependence of the manufacturing techniques on the surface properties by using the image processing methods and using the scanning electron microscope (SEM) for morphological properties in 3D and Taylor Hobson stylus profilometer for roughness properties in 2D. Three implant surfaces fabricated by different manufacturing techniques were inspected, and a machined surface was included into the study as a reference specimen. The results indicated that different surface treatments were strongly influenced surface morphology. Thus 2D and 3D precise inspection techniques were highlighted on the importance for surface characterization. Different image analyses techniques such as Dark-light technique were used to verify the surface measurement results. The computational phase was performed using image processing toolbox in Matlab with precise evaluation of the roughness for the implant surfaces. The relationship between the number of black and white pixels and surface roughness is presented. FFT image processing and analyses results explicitly imply that the technique is useful in the determination of surface roughness. The results showed that the number of black pixels in the image increases with increase in surface roughness.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

The spatial distribution of 6 centimeter gyroresonance emission from a flaring X-ray loop

Simultaneous high resolution soft X-ray, and 6-cm images of the decay phase of an M3 X-ray flare in Hale Region 16413 have been compared. The X-ray images were obtained with a sounding rocket flown on November 7, 1979 and the 6-cm observations were made with the VLA. A large loop system approximately 1.3 arc min in length, with an average temperature of about 8,000,000 K made up the X-ray flare structure. The peak 6-cm emission seemed to originate from a region below the X-ray loop, and its predicted flux due to thermal bremsstrahlung was approximately one order of magnitude less than observed. The expected gyroresonance absorption is examined through a loop geometry model, and it is found that thermal gyroresonance emission requiring large azimuthal or radial field components, or non-thermal gyrosynchrotron emission which involves continuous electron acceleration, may explain the observations.

Kahler, S. W.↗

Wavefront Sensing With Switched Lenses for Defocus Diversity

In an alternative hardware design for an apparatus used in image-based wavefront sensing, defocus diversity is introduced by means of fixed lenses that are mounted in a filter wheel (see figure) so that they can be alternately switched into a position in front of the focal plane of an electronic camera recording the image formed by the optical system under test. [The terms image-based, wavefront sensing, and defocus diversity are defined in the first of the three immediately preceding articles, Broadband Phase Retrieval for Image-Based Wavefront Sensing (GSC-14899-1).] Each lens in the filter wheel is designed so that the optical effect of placing it at the assigned position is equivalent to the optical effect of translating the camera a specified defocus distance along the optical axis. Heretofore, defocus diversity has been obtained by translating the imaging camera along the optical axis to various defocus positions. Because data must be taken at multiple, accurately measured defocus positions, it is necessary to mount the camera on a precise translation stage that must be calibrated for each defocus position and/or to use an optical encoder for measurement and feedback control of the defocus positions. Additional latency is introduced into the wavefront sensing process as the camera is translated to the various defocus positions. Moreover, if the optical system under test has a large focal length, the required defocus values are large, making it necessary to use a correspondingly bulky translation stage. By eliminating the need for translation of the camera, the alternative design simplifies and accelerates the wavefront-sensing process. This design is cost-effective in that the filterwheel/lens mechanism can be built from commercial catalog components. After initial calibration of the defocus value of each lens, a selected defocus value is introduced by simply rotating the filter wheel to place the corresponding lens in front of the camera. The rotation of the wheel can be automated by use of a motor drive, and further calibration is not necessary. Because a camera-translation stage is no longer needed, the size of the overall apparatus can be correspondingly reduced.

Dean, Bruce H.↗

Results of the 1988 NASA/JPL airborne SAR calibration campaign

During the spring of 1988, the NASA/JPL multifrequency, multipolarization SAR (synthetic aperture radar) flew in series of calibration experiments over the Goldstone dry lake bed. An array of calibration devices was deployed, including dihedral and trihedral corner reflectors, polarimetric active radar calibrators, passive receivers, and CW (continuous wave) tone generators. The aim of the campaign was to calibrate both amplitude and phase of the resulting SAR images, over long and short time scales. The results of the analysis of the calibration data collected in the spring of 1988 are presented. Trihedral corner reflector signatures and certain image background measures are used to externally calibrate relative amplitude and phase between polarizations at a given frequency, and to calibrate across frequencies. Assessments are made of the calibration accuracy as a function of image frame position for each frequency, and the stability of the radar calibration over long and short time-scales.

Freeman, A.↗

Quantification of synthesized hydration products using synchrotron microtomography and spectral analysis

The use of x-ray computed tomography (CT) as a standalone method has primarily been used to characterize pore structure, cracking and mechanical damage in cementitious systems due to low contrast in the hydrated phases. These limitations have resulted in the inability to extract quantifiable information on such phases. The goal of this research was to address the limitations caused by low contrast and improving the ability to distinguish the four primary hydrated phases in portland cement; C-S-H, calcium hydroxide, monosulfate, and ettringite. X-ray CT on individual layers, binary mixtures of phases, and quaternary mixtures of phases to represent a hydrated portland cement paste were imaged with synchrotron radiation. Known masses of each phase were converted to a volume and compared to the segmented image volumes. It was observed that adequate contrast in binary mixing of phases allowed for segmentation, and subsequent image analysis indicated quantifiable volumes could be extracted from the tomographic volume. However, low contrast was observed when C-S-H and monosulfate were paired together leading to difficulties segmenting in an unbiased manner. Quantification of phases in quaternary mixtures included larger errors than binary mixes due to histogram overlaps of monosulfate, C-S-H, and calcium hydroxide.

36 MATERIALS SCIENCE↗

Differential Phase-Contrast Scanning X-Ray Microscope For Observation Of Low-Z element Specimen

Differential phase-contrast scanning x-ray microscope/microtomography have been developed. A fast readout charge-coupled device (CCD) camera coupled with a visible-light conversion unit is used as a detector to record the transmitted intensity distribution of far-field image for every pixel in a scan. Simultaneous absorption and phase-contrast images are given from a single scan by image-processing of the CCD frames. The system is constructed at BL20XU of SPring-8, and its feasibility is demonstrated at the photon energy of 8 keV. A tantalum test chart is observed and its finest structure of 140 nm pitch pattern is clearly observed. Measured phase sensitivity is approximately {lambda}/270. Some low-Z element specimens are observed and obtained phase contrast image shows much higher sensitivity than that of absorption contrast.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Atomic structure of postgrowth annealed epitaxial Fe/(001)GaAs interfaces

The interfacial atomic structure of epitaxial Fe films grown by molecular beam epitaxy on c(4x4) reconstructed (001) GaAs was investigated using high-angle annular dark-field imaging in scanning transmission electron microscopy. No extended interfacial reaction phase is observed and the image contrast is discussed in terms of the interface atomic configuration. The images show an As-terminated semiconductor. The interface consists of a single partially occupied plane inserted between the Fe film and the GaAs, which most likely is occupied by Fe. This interface structure provides strong evidence for preferential Fe-As bonding across the interface.

36 MATERIALS SCIENCE↗

Study on hexagonal super-lattice pattern with surface discharges in dielectric barrier discharge

The hexagonal super-lattice pattern with surface discharges (SDs) in dielectric barrier discharge is investigated by intensified charge-coupled device. The pattern is composed of the bright spot and the dim spot which is located at the centroid of surrounding other three bright spots. The phase diagram of the pattern as a function of the gas pressure and the argon concentration is given. The instantaneous images indicate that the bright spot emerging at the front of the current pulse is formed by the volume discharge (VD), and dim spot occurring at the tail of the current pulse is formed by the SD. The above result shows that the SD is induced by the VD. The simulation of the electric fields of wall charges accumulated by VDs confirms that the dim spot is formed by the confluences of the SDs of surrounding other three bright spots. By using optical emission spectrum method, both the molecule vibration temperature and electron density of the SD are larger than that of the VD.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗