Search NASA⌕ Search

SEARCH · Search NASA

Results for “PLATES, FLAT - STRESSES”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,423 records · Page 79

Pulsed plasma thruster contamination studies

The exhaust plume of the one millipound pulsed plasma thruster has a measurable backflow upstream of the nozzle exit plane which may deposit on and degrade the performance of exposed spacecraft surfaces. High speed photographs and Faraday cup measurements suggest that this backflow is predominantly an electrically neutral, relatively low energy vapor. Articulated collimator quartz crystal microbalance measurements of this backflow were made for a thruster with a radically modified nozzle and a flat plate backflow shield, to determine the backflow sensitivity to nozzle design changes. The results are compared with the original nozzle backflow and show a measurable reduction in the backflow directly upstream of the shield.

Rudolph, L. K.↗

Aerodynamic heating for gaps in laminar and transitional boundary layers

The presence of gaps, slots, and/or steps in a surface may significantly perturb a supersonic boundary layer. The paper discusses heat-transfer distributions for a variety of gap configurations which were obtained by placing instrumented inserts in a flat-plate structural carrier. The data were obtained in a 3.50 foot hypersonic wind tunnel at a freestream Mach number of 5.10 over a range of Reynolds number from 2,570,000 to 8,110,000. The variables of the test program included the freestream Reynolds number and the gap configuration, e.g., width, depth, step height, number, and orientation.

Bertin, J. J.↗

A two-dimensional potential flow model for ground-induced effects on jet and fan inlets

A free-streamline potential flow model is developed for the flowfield external to a stationary jet or fan inlet in proximity to a ground plane. It is assumed that the flow is steady, incompressible, and irrotational. A two-dimensional flat plate geometry models the inlet configuration, and free streamline theory is used to avoid unrealistic infinite flow velocities at the lips of the inlet, and to account somewhat for flow separation. A water table experiment is used to verify the analytical results. The fact that the solutions are found to be limited to only a certain range of diameter-height ratios implies an overdetermination of the problem by free streamline theory. Also studied are the convective properties of small vortical disturbances superimposed on the ideal flow solution.

Newman, W. H.↗

Heat transfer through turbulent boundary layers - The effects of introduction of and recovery from convex curvature

Measurements have been made of the heat transfer through a turbulent boundary layer on a convexly curved isothermal wall and on a flat plate following the curved section. Data were taken for one free-stream velocity and two different ratios of boundary layer thickness to radius of curvature delta/R = 0.051 and delta/R = 0.077. Only small differences were observed in the distribution of heat transfer rates for the two boundary layer thicknesses tested, although differences were noted in the temperature distributions within the boundary layer

Simon, T. W.↗

Comparison of single crack propagation in lunar analogue glass and the failure strength of rocks

New data of crack propagation in lunar analogue glass provides important input for the construction of deformation maps (maps which delineate the rates and principal means of material deformation under various environmental conditions) applicable to the lunar crust. Comparison of single crack propagation data obtained on flat plates of glass and failure strength data obtained on fine grained rock samples show that single crack propagation velocities are directly related to the failure strength of rocks. The chemical reaction between water and silicon-oxygen bonds at the crack tip seems to be of first order. This greatly simplifies extrapolation to low partial pressures of H2O

Soga, N.↗

Numerical experiments in boundary-layer stability

Numerical solution of the three-dimensional incompressible Navier-Stokes equations is used to study the instability of a flat-plate boundary layer in a manner analogous to the vibrating-ribbon experiments. Flow-field structures are observed which are very similar to those found in the vibrating-ribbon experiment to which computational initial conditions have been matched. Streamwise periodicity is assumed in the simulation so that the evolution occurs in time, but the events which constitute the instability are so similar to the spatially occurring ones of the laboratory that it seems clear the physical processes involved are the same. A spectral and finite difference numerical algorithm is employed in the simulation.

Wray, A.↗

Nonlinear interaction of two waves in boundary-layer flows

First-order nonlinear interactions of Tollmien-Schlichting waves of different frequencies and initial amplitudes in boundary-layer flows are analyzed using the method of multiple scales. Numerical results for flow past a flat plate show that the spatial detuning wipes out resonant interactions unless the initial amplitudes are very large. Thus, a wave having a moderate amplitude has little influence on its subharmonic although it has a strong influence on its second harmonic. Moreover, two waves having moderate amplitudes have a strong influence on their difference frequency. The results show that the difference frequency can be very unstable when generated by the nonlinear interaction, even though it may be stable when introduced by itself in the boundary layer.

Nayfeh, A. H.↗

Performance analysis for collector-side reflector systems

The F-Chart method of solar collector performance evaluation is extended to a flat-plate collector system augmented with planar side reflectors. The modified F-Chart evaluations show that the augmentation of the collector has approximately the effect of increasing the collector area by 60%, and the energy supplied by the collector better matches the load. The installed reflector cost of about 10% of the collector cost is shown to be well justified.

Espy, P. N.↗

Simulation study of geometric shape factor approach to estimating earth emitted flux densities from wide field-of-view radiation measurements

A study was performed on the use of geometric shape factors to estimate earth-emitted flux densities from radiation measurements with wide field-of-view flat-plate radiometers on satellites. Sets of simulated irradiance measurements were computed for unrestricted and restricted field-of-view detectors. In these simulations, the earth radiation field was modeled using data from Nimbus 2 and 3. Geometric shape factors were derived and applied to these data to estimate flux densities on global and zonal scales. For measurements at a satellite altitude of 600 km, estimates of zonal flux density were in error 1.0 to 1.2%, and global flux density errors were less than 0.2%. Estimates with unrestricted field-of-view detectors were about the same for Lambertian and non-Lambertian radiation models, but were affected by satellite altitude. The opposite was found for the restricted field-of-view detectors.

Weaver, W. L.↗

Experiment on the turbulent boundary layer over convex walls and its recovery to flat-wall conditions

The experiments were performed at a ratio of the thickness at which velocity is 99% of the potential flow velocity to the surface radius of curvature of about 0.09 on a convex wall, where the curvature effects are strong. The data show that a flat-wall boundary layer is strongly affected by curvature only a few boundary layer thicknesses downstream of the start of convex curvature. On the other hand, in flow over a flat surface downstream of convex curvature, the effects of curvature persist downstream for ten or more boundary layer thicknesses. It appears that the boundary layer over a convex wall may have a multilayer character which is slow to return to normal, flat-plate equilibrium.

Gillis, J. C.↗

Structure and optical properties of evaporated films of the Cr- and V-group metals

Thin films of Cr, Mo, and W rapidly evaporated in high vacuum (5 x 10 to the -7th torr) onto room-temperature substrates show anomalously low reflectance (compared to bulk samples). From electron and X-ray diffraction and electron microscopy, the normal bcc crystal structure is found, but with very fine grains. Columnar grains about 100 A in diameter were separated by a less dense grain-boundary network about 10-A wide. The measured optical conductivity agrees with an inhomogeneous-medium model that assumes the normal crystalline conductivity for the grain interiors, with model parameters that correlate to the observed columnar grain size. In contrast, V and Nb films rapidly evaporated onto room-temperature substrates have the reflectance of bulk crystalline material. On liquid-nitrogen temperature substrates, however, V and Nb have normal bcc crystal structure but with small flat-plate grains, and the same model, with appropriate parameters, accounts for the optical conductivity. The difference between these two groups apparently depends on residual gases segregated at the grain boundaries in the Cr-group films.

Nestell, J. E., Jr.↗

Pyramidal-Reflector Solar Heater

Motor-driven reflector compensates for seasonal changes in Sun's altitude. System has flat-plate absorbers mounted on north side of attic interior. Skylight window on south-facing roof admits Sunlight into attic, lined with mirrors that reflect light to absorbers. Reflectors are inner surfaces of a pyramid lying on its side with window at its base and absorber plates in a cross-sectional plane near its apex.

Source record↗

Solar-Heated Water at a Motel--Mobile, Alabama

Solar-assisted hot-water system for a new 122-unit motor inn in Mobile, Alabama, generates more than half the energy needed for hot-water heating at motel each year. System consists of 93 flat-plate collectors, 2,500 gallon (9,500 1) insulated storage tank located outdoors, heat exchangers and controls. Electronic thermometers, measuring the temperatures at 22 locations monitor system performance.

Source record↗

Solar heating system at Security State Bank, Starkville, Mississippi

The 312 square feet of Solaron flat plate air collectors provide for 788 square feet of space heating, an estimated 55 percent of the heating load. Solar heated air is distributed to the 96 cubic foot steel cylinder, which contains two inch diameter rocks. An air handler unit moves the air over the collector and into the steel cylinder. Four motorized dampers and two gravity dampers are also part of the system. A Solaron controller which has sensors located at the collectors, rock storage, and at the return air, automatically controls the system. Auxiliary heating energy is provided by electric resistance duct heaters.

Source record↗

Solar hot water system installed at Day's Lodge, Atlanta, Georgia

The solar energy hot water system installed in the Days Inns of America, Inc., Atlanta, Georgia is described. This system provides for 81 percent of the total hot water demand. There are two separate systems, each serving one building of the lodge (total of 65 suites). The entire system contains only potable city water. The 1024 square feet of Grumman Sunstream Model 332 liquid flat plate collectors and the outside piping drain whenever the collector plates approach freezing or when power is interrupted. Solar heated water from the two above ground cement lined steel tanks (1000 gallon tank) is drawn into the electric Domestic Hot Water (DHW) tanks as hot water is drawn. Electric resistance units in the DHW tanks top off the solar heated water, if needed, to reach thermostat setting.

Source record↗

Solar heating and hot water system installed at Shoney's Restaurant, North Little Rock, Arkansas

A solar heating system designed to supply a major portion of the space and water heating requirements for a restaurant is described. The restaurant has a floor space of approximately 4,650 square feet and requires approximate 1500 gallons of hot water daily. The solar energy system consists of 1,428 square feet of Chamberlain flat plate liquid collector subsystem, and a 1500 gallon storage subsystem circulating hot water producing 321 x 10 to the 6th power Btu/Yr (specified) building heating and hot water heating.

Source record↗

Solar hot water system installed at Day's Inn Motel, Dallas, Texas (Valley View)

The solar system was designed to provide 65 percent of the total domestic hot water (DHW) demand. A liquid (water) flat plate collector (1,000 square feet) system automatically drains into the 1,000 gallon steel storage tank when the solar pump is not running. Heat is transferred from the DHW tanks through a shell and tube heat exchanger. A circulating pump between the DHW tanks and heat exchanger enables solar heated water to help make up standby losses. All pumps are controlled by differential temperature controllers.

Source record↗

Solar hot water system installed at Day's Inn Motel, Savannah, Georgia

The Solar System was designed to provide 50 percent of the total Domestic Hot Water (DHW) demand. Liquid Flat Plate Collectors (900 square feet) are used for the collector subsystem. The collector subsystem is closed loop, using 50 percent Ethylene Glycol solution antifreeze for freeze protection. The 1,000 gallon fiber glass storage tank contains two heat exchangers. One of the heat exchangers heats the storage tank with the collector solar energy. The other heat exchanger preheats the cold supply water as it passes through on the way to the Domestic Hot Water (DHW) tank heaters. Electrical energy supplements the solar energy for the DHW. The Collector Mounting System utilizes guy wires to structurally tie the collector array to the building.

Source record↗