Search NASA⌕ Search

SEARCH · Search NASA

Results for “Particle Methods”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,423 records · Page 79

Latent uncertainties of the precalculated track Monte Carlo method

Purpose: While significant progress has been made in speeding up Monte Carlo (MC) dose calculation methods, they remain too time-consuming for the purpose of inverse planning. To achieve clinically usable calculation speeds, a precalculated Monte Carlo (PMC) algorithm for proton and electron transport was developed to run on graphics processing units (GPUs). The algorithm utilizes pregenerated particle track data from conventional MC codes for different materials such as water, bone, and lung to produce dose distributions in voxelized phantoms. While PMC methods have been described in the past, an explicit quantification of the latent uncertainty arising from the limited number of unique tracks in the pregenerated track bank is missing from the paper. With a proper uncertainty analysis, an optimal number of tracks in the pregenerated track bank can be selected for a desired dose calculation uncertainty. Methods: Particle tracks were pregenerated for electrons and protons using EGSnrc and GEANT4 and saved in a database. The PMC algorithm for track selection, rotation, and transport was implemented on the Compute Unified Device Architecture (CUDA) 4.0 programming framework. PMC dose distributions were calculated in a variety of media and compared to benchmark dose distributions simulated from the corresponding general-purpose MC codes in the same conditions. A latent uncertainty metric was defined and analysis was performed by varying the pregenerated track bank size and the number of simulated primary particle histories and comparing dose values to a “ground truth” benchmark dose distribution calculated to 0.04% average uncertainty in voxels with dose greater than 20% of D{sub max}. Efficiency metrics were calculated against benchmark MC codes on a single CPU core with no variance reduction. Results: Dose distributions generated using PMC and benchmark MC codes were compared and found to be within 2% of each other in voxels with dose values greater than 20% of the maximum dose. In proton calculations, a small (≤1 mm) distance-to-agreement error was observed at the Bragg peak. Latent uncertainty was characterized for electrons and found to follow a Poisson distribution with the number of unique tracks per energy. A track bank of 12 energies and 60000 unique tracks per pregenerated energy in water had a size of 2.4 GB and achieved a latent uncertainty of approximately 1% at an optimal efficiency gain over DOSXYZnrc. Larger track banks produced a lower latent uncertainty at the cost of increased memory consumption. Using an NVIDIA GTX 590, efficiency analysis showed a 807 × efficiency increase over DOSXYZnrc for 16 MeV electrons in water and 508 × for 16 MeV electrons in bone. Conclusions: The PMC method can calculate dose distributions for electrons and protons to a statistical uncertainty of 1% with a large efficiency gain over conventional MC codes. Before performing clinical dose calculations, models to calculate dose contributions from uncharged particles must be implemented. Following the successful implementation of these models, the PMC method will be evaluated as a candidate for inverse planning of modulated electron radiation therapy and scanned proton beams.

07 ISOTOPE AND RADIATION SOURCES↗

Correlation Between Magnetization and Particle Size of CdS Nanostructures by Solvothermal Method

Micro- and nano-structures of CdS including microrods, nanoparticles, nanorods, microspheres, and nanosheets were prepared by solvothermal method using monoethanolamine (EA), ethylene glycol (EG), and ethylenediamine (EN) to act as a mixed and pure solvent at multiple Cd and S concentrations. X-ray diffraction (XRD) patterns have shown CdS micro- and nano-structures with hexagonal and wurtzite structures. Scanning electron microscopy (SEM) has depicted nanosheet existence, microsphere, and microrods of CdS at various volume ratios. Transmission electron microscopy (TEM) has shown nanorod existence and nanoparticles of CdS at various volume ratios. Optical properties have been investigated using UV-Vis. A vibrating sample magnetometer (VSM) has been used to measure the CdS nanoparticle ferromagnetism at ambient temperature. The saturation magnetization has exhibited 9.109 (10{sup −3} emu/g). The ferromagnetic properties of CdS are referred to their structural defects.

77 NANOSCIENCE AND NANOTECHNOLOGY↗

Scaling of Multimillion-Atom Biological Molecular Dynamics Simulation on a Petascale Supercomputer

A strategy is described for a fast all-atom molecular dynamics simulation of multimillion-atom biological systems on massively parallel supercomputers. The strategy is developed using benchmark systems of particular interest to bioenergy research, comprising models of cellulose and lignocellulosic biomass in an aqueous solution. The approach involves using the reaction field (RF) method for the computation of long-range electrostatic interactions, which permits efficient scaling on many thousands of cores. Although the range of applicability of the RF method for biomolecular systems remains to be demonstrated, for the benchmark systems the use of the RF produces molecular dipole moments, Kirkwood G factors, other structural properties, and mean-square fluctuations in excellent agreement with those obtained with the commonly used Particle Mesh Ewald method. With RF, three million- and five million atom biological systems scale well up to 30k cores, producing 30 ns/day. Atomistic simulations of very large systems for time scales approaching the microsecond would, therefore, appear now to be within reach.

09 BIOMASS FUELS↗

Measuring the complex field scattered by single submicron particles

We describe a method for simultaneous measurements of the real and imaginary parts of the field scattered by single nanoparticles illuminated by a laser beam, exploiting a self-reference interferometric scheme relying on the fundamentals of the Optical Theorem. Results obtained with calibrated spheres of different materials are compared to the expected values obtained through a simplified analytical model without any free parameters, and the method is applied to a highly polydisperse water suspension of Poly(D,L-lactide-co-glycolide) nanoparticles. Advantages with respect to existing methods and possible applications are discussed.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Machine Learning for Predictive Performance Analysis in Charged Particle Beam Tools

Imaging methods driven by probes, electrons, and ions have played a dominant role in modern science and engineering. Opportunities for machine vision and AI that focus on consumer problems like driving and feature recognition, are now presenting themselves for automating aspects of the scientific processes. This proposal aims to enable and drive discovery in ultra-low energy implantation by taking advantage of faster processing, flexible control and detection methods, and architecture-agnostic workflows that will result in higher efficiency and shorter scientific development cycles. Custom microscope control, collection and analysis hardware will provide a framework for conducting novel in situ experiments revealing unprecedented insight into surface dynamics at the nanoscale. Ion implantation is a key capability for the semiconductor industry. As devices shrink, novel materials enter the manufacturing line, and quantum technologies transition to being more mainstream. Traditional implantation methods fall short in terms of energy, ion species, and positional precision. Here we demonstrate 1 keV focused ion beam Au implantation into Si and validate the results via atom probe tomography. We show the Au implant depth at 1 keV is 0.8 nm and that identical results for low energy ion implants can be achieved by either lowering the column voltage, or decelerating ions using bias – while maintaining a sub-micron beam focus. We compare our experimental results to static calculations using SRIM and dynamic calculations using binary collision approximation codes TRIDYN and IMSIL. A large discrepancy between the static and dynamic simulation is found that is due to lattice enrichment with high stopping power Au and surface sputtering. Additionally, we demonstrate how model details are particularly important to the simulation of these low-energy heavy-ion implantations. Finally, we discuss how our results pave a way to much lower implantation energies, while maintaining high spatial resolution.

47 OTHER INSTRUMENTATION↗

Biocomposite materials and methods for making the same

A particle (and a composition that includes a plurality of the particles) that includes at least one polypeptide molecule and at least one polymer covalently bound to the polypeptide molecule so as to form a polymer shell substantially encompassing the polypeptide molecule, wherein the particle does not define a dimension greater than about 1 .mu.m. One example for making the particle includes modifying the polypeptide molecule to provide .alpha., .beta.-ethylenically unsaturated terminal functional groups, mixing the modified polypeptide molecule with a silicon-containing polymerizable compound, and subjecting the resulting mixture to conditions sufficient for polymerizing the polymerizable compound to form the particle.

36 MATERIALS SCIENCE↗

Biocomposite materials and methods for making the same

A particle (and a composition that includes a plurality of the particles) that includes at least one polypeptide molecule and at least one polymer covalently bound to the polypeptide molecule so as to form a polymer shell substantially encompassing the polypeptide molecule, wherein the particle does not define a dimension greater than about 1 .mu.m. One example for making the particle includes modifying the polypeptide molecule to provide .alpha., .beta.-ethylenically unsaturated terminal functional groups, mixing the modified polypeptide molecule with a silicon-containing polymerizable compound, and subjecting the resulting mixture to conditions sufficient for polymerizing the polymerizable compound to form the particle.

Grate, Jay W↗

Generation of discrete scattering cross sections and demonstration of Monte Carlo charged particle transport in the Milagro IMC code package

A new method for generating discrete scattering cross sections to be used in charged particle transport calculations is investigated. The method of data generation is presented and compared to current methods for obtaining discrete cross sections. The new, more generalized approach allows greater flexibility in choosing a cross section model from which to derive discrete values. Cross section data generated with the new method is verified through a comparison with discrete data obtained with an existing method. Additionally, a charged particle transport capability is demonstrated in the time-dependent Implicit Monte Carlo radiative transfer code package, Milagro. The implementation of this capability is verified using test problems with analytic solutions as well as a comparison of electron dose-depth profiles calculated with Milagro and an already-established electron transport code. An initial investigation of a preliminary integration of the discrete cross section generation method with the new charged particle transport capability in Milagro is also presented. (authors)

97 MATHEMATICS AND COMPUTING↗

Reweighting Underlying Event and Colour Reconnection parameter variations in Sherpa

We propose and validate a new method to trace the impact of parameter variations in the simulation of multi-parton interactions and colour reconnections in the Sherpa event generator. They are reflected, at an event-by-event basis, through relative weights with respect to the central production parameters that give rise to the generated events and distributions. Our method facilitates the tuning of the Monte Carlo event generator at a dramatically reduced computational cost, alleviates parameter sensitivity studies, and enables robust quantification of parametric uncertainties on-the-fly, one of the missing ingredients for future simulations of high-energy particle collisions. The method can easily be adapted to and implemented in other event generators. To illustrate its potential, we here consider combined tunes of the multi-parton-interaction and colour-reconnection models in Sherpa using LHC proton-proton collision data at $\sqrt{s}=7\,\text{TeV}$. We furthermore calibrate the energy-scaling behaviour of dimensionful model parameters based on $\sqrt{s}=13\,\text{TeV}$ LHC data and Tevatron data taken at $\sqrt{s}=1.96\,\text{TeV}$.

Pabst, Moritz [Gottingen U.]↗

Implementation of a Mesh refinement algorithm into the quasi-static PIC code QuickPIC

Plasma-based acceleration (PBA) has emerged as a promising candidate for the accelerator technology used to build a future linear collider and/or an advanced light source. In PBA, a trailing or witness particle beam is accelerated in the plasma wave wakefield (WF) created by a laser or particle beam driver. The WF is often nonlinear and involves the crossing of plasma particle trajectories in real space and thus particle-in-cell methods are used. The distance over which the drive beam evolves is several orders of magnitude larger than the wake wavelength. This large disparity in length scales is amenable to the quasi-static approach. Three-dimensional (3D), quasi-static (QS), particle-in-cell (PIC) codes, e.g., QuickPIC, have been shown to provide high fidelity simulation capability with 2-4 orders of magnitude speedup over 3D fully explicit PIC codes. In PBA, the witness beam needs to be matched to the focusing forces of the WF to reduce the emittance growth. In some linear collider designs, the matched spot size of the witness beam can be 2 to 3 orders of magnitude smaller than the spot size (and wavelength) of the wakefield. Such an additional disparity in length scales is ideal for mesh refinement where the WF within the witness beam is described on a finer mesh than the rest of the WF. A mesh refinement scheme is described that has been implemented into the 3D QS PIC code, QuickPIC. Very fine (high) resolution is used in a small spatial region that includes the witness beam and progressively coarser resolutions in the rest of the simulation domain. A fast multigrid Poisson solver has been implemented for the field solve on the refined meshes and a Fast Fourier Transform (FFT) based Poisson solver is used for the coarse mesh. The code has been parallelized with both MPI and OpenMP, and the parallel scalability has also been improved by using pipelining. A preliminary adaptive mesh refinement technique is described to optimize the computational time for simulations with an evolving witness beam size. Several test problems are used to verify that the mesh refinement algorithm provides accurate results. Additionally, the results are benchmarked against highly resolved simulations exhibiting near-azimuthal symmetry, performed using QPAD—a novel hybrid QS PIC code that uses a PIC description in the coordinates (r, ct – z) and a gridless description in the azimuthal angle, Φ.

Linear collider↗