Search NASA⌕ Search

SEARCH · Search NASA

Results for “Protocol”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,423 records · Page 79

Objective characterization of GE Discovery CT750 HD scanner: Gemstone spectral imaging mode

Purpose: To objectively characterize the performance of the gemstone spectral imaging (GSI) mode of GE CT750 HD scanner from a user's perspective. Methods: A regular scan protocol that approximates the adult abdomen scan protocol frequently used in the authors' institute was selected as the baseline, and a GSI protocol (preset 11) that is similar to the regular protocol and has a moderate dose level (CTDI{sub vol}=26.27 mGy) was compared to the baseline protocol. The resolving power of both protocols was characterized in terms of modulation transfer functions and high contrast resolution bar readings. Their noise characteristics were studied through noise power spectra, and their low contrast detectability was compared via contrast-to-noise ratio. Material decomposition capability of GSI was evaluated by scanning iodine solutions of 9-24 mg/ml iodine concentration in a Gammex CT phantom and by examining the estimated iodine concentration. In addition, a formula describing the dependency of HU in iodine enhanced area on GSI monochromatic energies and iodine concentrations was provided and the theoretical values were compared with the measured results. Results: The resolutions levels of 50%, 10%, and 5% MTF of GSI monochromatic images at 65 keV agree with those of the regular protocol within 0.1 lp/cm. GSI monochromatic images at 65 keV demonstrated the lowest noise level among GSI images of different monochromatic energies and showed very similar noise magnitude and noise power distribution as compared to the regular protocol images. The CNR of 60 and 65 keV GSI monoimages are approximately 100% of those of the regular protocol images. Estimated iodine concentration levels agreed with the actual values within 2% when the iodine solutions were placed at 3, 9, 12 o'clock positions of the phantom; when iodine solutions were placed at the phantom center and at 6 o'clock position, higher discrepancies of 2%-10% were observed. The observed dependency of HU on keV and iodine concentration levels agreed with the expectation from x-ray attenuations. Conclusions: Equivalent performances were observed in the comparison between GSI 65 keV monochromatic images and images from a regular abdomen scan protocol. This suggests the possibility of GSI to be employed in routine abdominal scans, which would potentially offer more information through its capabilities of material decomposition.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

SU-F-R-11: Designing Quality and Safety Informatics Through Implementation of a CT Radiation Dose Monitoring Program

Purpose: Recent legislative and accreditation requirements have driven rapid development and implementation of CT radiation dose monitoring solutions. Institutions must determine how to improve quality, safety, and consistency of their clinical performance. The purpose of this work was to design a strategy and meaningful characterization of results from an in-house, clinically-deployed dose monitoring solution. Methods: A dose monitoring platform was designed by our imaging physics group that focused on extracting protocol parameters, dose metrics, and patient demographics and size. Compared to most commercial solutions, which focus on individual exam alerts and global thresholds, the program sought to characterize overall consistency and targeted thresholds based on eight analytic interrogations. Those were based on explicit questions related to protocol application, national benchmarks, protocol and size-specific dose targets, operational consistency, outliers, temporal trends, intra-system variability, and consistent use of electronic protocols. Using historical data since the start of 2013, 95% and 99% intervals were used to establish yellow and amber parameterized dose alert thresholds, respectively, as a function of protocol, scanner, and size. Results: Quarterly reports have been generated for three hospitals for 3 quarters of 2015 totaling 27880, 28502, 30631 exams, respectively. Four adult and two pediatric protocols were higher than external institutional benchmarks. Four protocol dose levels were being inconsistently applied as a function of patient size. For the three hospitals, the minimum and maximum amber outlier percentages were [1.53%,2.28%], [0.76%,1.8%], [0.94%,1.17%], respectively. Compared with the electronic protocols, 10 protocols were found to be used with some inconsistency. Conclusion: Dose monitoring can satisfy requirements with global alert thresholds and patient dose records, but the real value is in optimizing patient-specific protocols, balancing image quality trade-offs that dose-reduction strategies promise, and improving the performance and consistency of a clinical operation. Data plots that capture patient demographics and scanner performance demonstrate that value.

60 APPLIED LIFE SCIENCES↗

The Behavior of TCP and Its Extensions in Space

The performance of Transmission Control Protocol (TCP) in space has been examined from the observations of simulation and experimental tests for several years at National Aeronautics and Space Administration (NASA), Department of Defense (DoD) and universities. At New Mexico State University (NMSU), we have been concentrating on studying the performance of two protocol suites: the file transfer protocol (ftp) running over Transmission Control Protocol/Internet Protocol (TCP/IP) stack and the file protocol (fp) running over the Space Communications Protocol Standards (SCPS)-Transport Protocol (TP) developed under the Consultative Committee for Space Data Systems (CCSDS) standards process. SCPS-TP is considered to be TCP's extensions for space communications. This dissertation experimentally studies the behavior of TCP and SCPS-TP by running the protocol suites over both the Space-to-Ground Link Simulator (SGLS) test-bed and realistic satellite link. The study concentrates on comparing protocol behavior by plotting the averaged file transfer times for different experimental configurations and analyzing them using Statistical Analysis System (SAS) based procedures. The effects of different link delays and various Bit-Error-Rates (BERS) on each protocol performance are also studied and linear regression models are built for experiments over SGLS test-bed to reflect the relationships between the file transfer time and various transmission conditions.

Wang, Ruhai↗

IONAC-Lite

The Interplanetary Overlay Net - working Protocol Accelerator (IONAC) described previously in The Inter - planetary Overlay Networking Protocol Accelerator (NPO-45584), NASA Tech Briefs, Vol. 32, No. 10, (October 2008) p. 106 (http://www.techbriefs.com/component/ content/article/3317) provides functions that implement the Delay Tolerant Networking (DTN) bundle protocol. New missions that require high-speed downlink-only use of DTN can now be accommodated by the unidirectional IONAC-Lite to support high data rate downlink mission applications. Due to constrained energy resources, a conventional software implementation of the DTN protocol can provide only limited throughput for any given reasonable energy consumption rate. The IONAC-Lite DTN Protocol Accelerator is able to reduce this energy consumption by an order of magnitude and increase the throughput capability by two orders of magnitude. In addition, a conventional DTN implementation requires a bundle database with a considerable storage requirement. In very high downlink datarate missions such as near-Earth radar science missions, the storage space utilization needs to be maximized for science data and minimized for communications protocol-related storage needs. The IONAC-Lite DTN Protocol Accelerator is implemented in a reconfigurable hardware device to accomplish exactly what s needed for high-throughput DTN downlink-only scenarios. The following are salient features of the IONAC-Lite implementation: An implementation of the Bundle Protocol for an environment that requires a very high rate bundle egress data rate. The C&DH (command and data handling) subsystem is also expected to be very constrained so the interaction with the C&DH processor and the temporary storage are minimized. Fully pipelined design so that bundle processing database is not required. Implements a lookup table-based approach to eliminate multi-pass processing requirement imposed by the Bundle Protocol header s length field structure and the SDNV (self-delimiting numeric value) data field formatting. 8-bit parallel datapath to support high data-rate missions. Reduced resource utilization implementation for missions that do not require custody transfer features. There was no known implementation of the DTN protocol in a field programmable gate array (FPGA) device prior to the current implementation. The combination of energy and performance optimization that embodies this design makes the work novel.

Torgerson, Jordan L.↗

Automatic Determination of the Need for Intravenous Contrast in Musculoskeletal MRI Examinations Using IBM Watson’s Natural Language Processing Algorithm

Magnetic resonance imaging (MRI) protocoling can be time- and resource-intensive, and protocols can often be suboptimal dependent upon the expertise or preferences of the protocoling radiologist. Providing a best-practice recommendation for an MRI protocol has the potential to improve efficiency and decrease the likelihood of a suboptimal or erroneous study. The goal of this study was to develop and validate a machine learning-based natural language classifier that can automatically assign the use of intravenous contrast for musculoskeletal MRI protocols based upon the free-text clinical indication of the study, thereby improving efficiency of the protocoling radiologist and potentially decreasing errors. We utilized a deep learning-based natural language classification system from IBM Watson, a question-answering supercomputer that gained fame after challenging the best human players on Jeopardy! in 2011. We compared this solution to a series of traditional machine learning-based natural language processing techniques that utilize a term-document frequency matrix. Each classifier was trained with 1240 MRI protocols plus their respective clinical indications and validated with a test set of 280. Ground truth of contrast assignment was obtained from the clinical record. For evaluation of inter-reader agreement, a blinded second reader radiologist analyzed all cases and determined contrast assignment based on only the free-text clinical indication. In the test set, Watson demonstrated overall accuracy of 83.2% when compared to the original protocol. This was similar to the overall accuracy of 80.2% achieved by an ensemble of eight traditional machine learning algorithms based on a term-document matrix. When compared to the second reader’s contrast assignment, Watson achieved 88.6% agreement. When evaluating only the subset of cases where the original protocol and second reader were concordant (n = 251), agreement climbed further to 90.0%. The classifier was relatively robust to spelling and grammatical errors, which were frequent. Implementation of this automated MR contrast determination system as a clinical decision support tool may save considerable time and effort of the radiologist while potentially decreasing error rates, and require no change in order entry or workflow.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Fair and optimistic quantum contract signing

We present a fair and optimistic quantum-contract-signing protocol between two clients that requires no communication with the third trusted party during the exchange phase. We discuss its fairness and show that it is possible to design such a protocol for which the probability of a dishonest client to cheat becomes negligible and scales as N{sup -1/2}, where N is the number of messages exchanged between the clients. Our protocol is not based on the exchange of signed messages: Its fairness is based on the laws of quantum mechanics. Thus, it is abuse free, and the clients do not have to generate new keys for each message during the exchange phase. We discuss a real-life scenario when measurement errors and qubit-state corruption due to noisy channels and imperfect quantum memories occur and argue that for a real, good-enough measurement apparatus, transmission channels, and quantum memories, our protocol would still be fair. Apart from stable quantum memories, the other segments of our protocol could be implemented by today's technology, as they require in essence the same type of apparatus as the one needed for the Bennett-Brassard 1984 (BB84) cryptographic protocol. Finally, we briefly discuss two alternative versions of the protocol, one that uses only two states [based on the Bennett 1992 (B92) protocol] and the other that uses entangled pairs, and show that it is possible to generalize our protocol to an arbitrary number of clients.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Deterministic generation of remote entanglement with active quantum feedback

We develop and study protocols for deterministic remote entanglement generation using quantum feedback, without relying on an entangling Hamiltonian. In order to formulate the most effective experimentally feasible protocol, we introduce the notion of average-sense locally optimal feedback protocols, which do not require real-time quantum state estimation, a difficult component of real-time quantum feedback control. We use this notion of optimality to construct two protocols that can deterministically create maximal entanglement: a semiclassical feedback protocol for low-efficiency measurements and a quantum feedback protocol for high-efficiency measurements. The latter reduces to direct feedback in the continuous-time limit, whose dynamics can be modeled by a Wiseman-Milburn feedback master equation, which yields an analytic solution in the limit of unit measurement efficiency. Our formalism can smoothly interpolate between continuous-time and discrete-time descriptions of feedback dynamics and we exploit this feature to derive a superior hybrid protocol for arbitrary nonunit measurement efficiency that switches between quantum and semiclassical protocols. Lastly, we show using simulations incorporating experimental imperfections that deterministic entanglement of remote superconducting qubits may be achieved with current technology using the continuous-time feedback protocol alone.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

SU-E-P-03: Implementing a Low Dose Lung Screening CT Program Meeting Regulatory Requirements

Purpose: To provide information pertaining to IROC Houston QA Center's (RPC) credentialing process for institutions participating in NCI-sponsored clinical trials. Purpose: Provide guidance to the Radiology Departments with the intent of implementing a Low Dose CT Screening Program using different CT Scanners with multiple techniques within the framework of the required state regulations. Method: State Requirements for the purpose of implementing a Low Dose CT Lung Protocol required working with the Radiology and Pulmonary Department in setting up a Low Dose Screening Protocol designed to reduce the radiation burden to the patients enrolled. Radiation dose measurements (CTDIvol) for various CT manufacturers (Siemens16, Siemens 64, Philips 64, and Neusoft128) for three different weight based protocols. All scans were reviewed by the Radiologist. Prior to starting a low dose lung screening protocol, information had to be submitted to the state for approval. Performing a Healing Arts protocol requires extensive information. This not only includes name and address of the applicant but a detailed description of the disease, the x-ray examination and the population to be examined. The unit had to be tested by a qualified expert using the technique charts. The credentials of all the operators, the supervisors and the Radiologists had to be submitted to the state. Results: All the appropriate documentation was sent to the state for review. The measured results between the Low Dose Protocol versus the default Adult Chest Protocol showed that there was a dose reduction of 65% for small (100-150 lb.) patient, 75% for the Medium patient (151-250 lbs.), and a 55% reduction for the Large patient ( over 250 lbs.). Conclusion: Measured results indicated that the Low Dose Protocol indeed lowered the screening patient's radiation dose and the institution was able to submit the protocol to the State's regulators.

60 APPLIED LIFE SCIENCES↗

Quality control for quantitative multicenter whole-body PET/MR studies: A NEMA image quality phantom study with three current PET/MR systems

Purpose: Integrated positron emission tomography/magnetic resonance (PET/MR) systems derive the PET attenuation correction (AC) from dedicated MR sequences. While MR-AC performs reasonably well in clinical patient imaging, it may fail for phantom-based quality control (QC). The authors assess the applicability of different protocols for PET QC in multicenter PET/MR imaging. Methods: The National Electrical Manufacturers Association NU 2 2007 image quality phantom was imaged on three combined PET/MR systems: a Philips Ingenuity TF PET/MR, a Siemens Biograph mMR, and a GE SIGNA PET/MR (prototype) system. The phantom was filled according to the EANM FDG-PET/CT guideline 1.0 and scanned for 5 min over 1 bed. Two MR-AC imaging protocols were tested: standard clinical procedures and a dedicated protocol for phantom tests. Depending on the system, the dedicated phantom protocol employs a two-class (water and air) segmentation of the MR data or a CT-based template. Differences in attenuation- and SUV recovery coefficients (RC) are reported. PET/CT-based simulations were performed to simulate the various artifacts seen in the AC maps (μ-map) and their impact on the accuracy of phantom-based QC. Results: Clinical MR-AC protocols caused substantial errors and artifacts in the AC maps, resulting in underestimations of the reconstructed PET activity of up to 27%, depending on the PET/MR system. Using dedicated phantom MR-AC protocols, PET bias was reduced to −8%. Mean and max SUV RC met EARL multicenter PET performance specifications for most contrast objects, but only when using the dedicated phantom protocol. Simulations confirmed the bias in experimental data to be caused by incorrect AC maps resulting from the use of clinical MR-AC protocols. Conclusions: Phantom-based quality control of PET/MR systems in a multicenter, multivendor setting may be performed with sufficient accuracy, but only when dedicated phantom acquisition and processing protocols are used for attenuation correction.

60 APPLIED LIFE SCIENCES↗

SU-F-I-36: In-Utero Dose Measurements Within Postmortem Subjects for Estimating Fetal Doses in Pregnant Patients Examined with Pulmonary Embolism, Trauma, and Appendicitis CT

Purpose: The imaging of pregnant patients is medically necessary in certain clinical situations. The purpose of this work was to directly measure uterine doses in a cadaver scanned with CT protocols commonly performed on pregnant patients in order to estimate fetal dose and assess potential risk. Method: One postmortem subject was scanned on a 320-slice CT scanner with standard pulmonary embolism, trauma, and appendicitis protocols. All protocols were performed with the scan parameters and ranges currently used in clinical practice. Exams were performed both with and without iterative reconstruction to highlight the dose savings potential. Optically stimulated luminescent dosimeters (OSLDs) were inserted into the uterus in order to approximate fetal doses. Results: In the pulmonary embolism CT protocol, the uterus is outside of the primary beam, and the dose to the uterus was under 1 mGy. In the trauma and appendicitis protocols, the uterus is in the primary beam, the fetal dose estimates were 30.5 mGy for the trauma protocol, and 20.6 mGy for the appendicitis protocol. Iterative reconstruction reduced fetal doses by 30%, with uterine doses at 21.3 for the trauma and 14.3 mGy for the appendicitis protocol. Conclusion: Fetal doses were under 1 mGy when exposed to scatter radiation, and under 50 mGy when exposed to primary radiation with the trauma and appendicitis protocols. Consistent with the National Council on Radiation Protection & Measurements (NCRP) and the International Commission on Radiological Protection (ICRP), these doses exhibit a negligible risk to the fetus, with only a small increased risk of cancer. Still, CT scans are not recommended during pregnancy unless the benefits of the exam clearly outweigh the potential risk. Furthermore, when possible, pregnant patients should be examined on CT scanners equipped with iterative reconstruction in order to keep patient doses as low as reasonable achievable.

60 APPLIED LIFE SCIENCES↗

Comparative Analysis of In Vitro Responses and Regeneration between Diverse Bioenergy Sorghum Genotypes

Sorghum has been considered a recalcitrant plant in vitro and suffers from a lack of regeneration protocols that function broadly and efficiently across a range of genotypes. This study was initiated to identify differential genotype-in vitro protocol responses across a range of bioenergy sorghum parental lines and the common grain sorghum genotype Tx430 in order to characterize response profiles for use in future genetic studies. Two different in vitro protocols, LG and WU, were used for comparisons. Distinct genotype-protocol responses were observed, and the WU protocol performed significantly better for plantlet regeneration. Most bioenergy genotypes performed as well, if not better than Tx430, with Rio and PI329311 as the top regenerating lines. Genotypes displayed protocol-dependent, differential phenolic exudation responses, as indicated by medium browning. During the callus induction phase, genotypes prone to medium browning exhibited a response on WU medium which was either equal or greater than on LG medium. Genotype- and protocol-dependent albino plantlet regeneration was also noted, with three of the bioenergy genotypes showing albino plantlet regeneration. Grassl, Rio and Pink Kafir were susceptible to albino plantlet regeneration, with the response strongly associated with the WU protocol. These bioenergy parental genotypes, and their differential responses under two in vitro protocols, provide tools to further explore and assess the role of genetic loci, candidate genes, and allelic variants in the regulation of in vitro responsiveness in sorghum.

54 ENVIRONMENTAL SCIENCES↗

Architectural Analysis of Complex Evolving Systems of Systems

The goal of this collaborative project between FC-MD, APL, and GSFC and supported by NASA IV&V Software Assurance Research Program (SARP), was to develop a tool, Dynamic SAVE, or Dyn-SAVE for short, for analyzing architectures of systems of systems. The project team was comprised of the principal investigator (PI) from FC-MD and four other FC-MD scientists (part time) and several FC-MD students (full time), as well as, two APL software architects (part time), and one NASA POC (part time). The PI and FC-MD scientists together with APL architects were responsible for requirements analysis, and for applying and evaluating the Dyn-SAVE tool and method. The PI and a group of FC-MD scientists were responsible for improving the method and conducting outreach activities, while another group of FC-MD scientists were responsible for development and improvement of the tool. Oversight and reporting was conducted by the PI and NASA POC. The project team produced many results including several prototypes of the Dyn-SAVE tool and method, several case studies documenting how the tool and method was applied to APL s software systems, and several published papers in highly respected conferences and journals. Dyn-SAVE as developed and enhanced throughout this research period, is a software tool intended for software developers and architects, software integration testers, and persons who need to analyze software systems from the point of view of how it communicates with other systems. Using the tool, the user specifies the planned communication behavior of the system modeled as a sequence diagram. The user then captures and imports the actual communication behavior of the system, which is then converted and visualized as a sequence diagram by Dyn-SAVE. After mapping the planned to the actual and specifying parameter and timing constraints, Dyn-SAVE detects and highlights deviations between the planned and the actual behavior. Requirements based on the need to analyze two inter-system communication protocols that are representative of protocols used in the Aerospace industry have been specified. The protocols are related: APL s Common Ground System (CGS) as used in the MErcury Surface, Space ENvironment, GEochemistry, and Ranging (MESSENGER) and the Radiation Belt Space Probes (RBSP) missions. The analyzed communications were implementations of the Telemetry protocol and the CCSDS File Delivery Protocol (CFDP) protocol. Based on these requirements, three prototypes of Dyn-SAVE were developed and applied to these protocols. The application of Dyn-SAVE to these protocols resulted in the detection of several issues. Dyn-SAVE was also applied to several Testbeds that have previously been used for experimentation earlier on this project, as well as, to other protocols and logs for testing its broader applicability. For example, Dyn-SAVE was used to analyze 1) the communication pattern between a web browser and a web server, 2) the system log of a computer in order to detect offnominal computer shut-down behavior, and 3) the actual test cases of NASA Goddard s Core Flight System (CFS) and automatically generated test cases in order to determine the overlap between the two sets of test cases. In all cases, Dyn-SAVE assisted in providing insightful conclusions about each of the cases identified above.

Lindvall, Mikael↗

Encryption for Remote Control via Internet or Intranet

A data-communication protocol has been devised to enable secure, reliable remote control of processes and equipment via a collision-based network, while using minimal bandwidth and computation. The network could be the Internet or an intranet. Control is made secure by use of both a password and a dynamic key, which is sent transparently to a remote user by the controlled computer (that is, the computer, located at the site of the equipment or process to be controlled, that exerts direct control over the process). The protocol functions in the presence of network latency, overcomes errors caused by missed dynamic keys, and defeats attempts by unauthorized remote users to gain control. The protocol is not suitable for real-time control, but is well suited for applications in which control latencies up to about 0.5 second are acceptable. The encryption scheme involves the use of both a dynamic and a private key, without any additional overhead that would degrade performance. The dynamic key is embedded in the equipment- or process-monitor data packets sent out by the controlled computer: in other words, the dynamic key is a subset of the data in each such data packet. The controlled computer maintains a history of the last 3 to 5 data packets for use in decrypting incoming control commands. In addition, the controlled computer records a private key (password) that is given to the remote computer. The encrypted incoming command is permuted by both the dynamic and private key. A person who records the command data in a given packet for hostile purposes cannot use that packet after the public key expires (typically within 3 seconds). Even a person in possession of an unauthorized copy of the command/remote-display software cannot use that software in the absence of the password. The use of a dynamic key embedded in the outgoing data makes the central-processing unit overhead very small. The use of a National Instruments DataSocket(TradeMark) (or equivalent) protocol or the User Datagram Protocol makes it possible to obtain reasonably short response times: Typical response times in event-driven control, using packets sized .300 bytes, are <0.2 second for commands issued from locations anywhere on Earth. The protocol requires that control commands represent absolute values of controlled parameters (e.g., a specified temperature), as distinguished from changes in values of controlled parameters (e.g., a specified increment of temperature). Each command is issued three or more times to ensure delivery in crowded networks. The use of absolute-value commands prevents additional (redundant) commands from causing trouble. Because a remote controlling computer receives "talkback" in the form of data packets from the controlled computer, typically within a time interval < or =1 s, the controlling computer can re-issue a command if network failure has occurred. The controlled computer, the process or equipment that it controls, and any human operator(s) at the site of the controlled equipment or process should be equipped with safety measures to prevent damage to equipment or injury to humans. These features could be a combination of software, external hardware, and intervention by the human operator(s). The protocol is not fail-safe, but by adopting these safety measures as part of the protocol, one makes the protocol a robust means of controlling remote processes and equipment by use of typical office computers via intranets and/or the Internet.

Lineberger, Lewis↗

In-Space Networking on NASA's SCAN Testbed

The NASA Space Communications and Navigation (SCaN) Testbed, an external payload onboard the International Space Station, is equipped with three software defined radios and a flight computer for supporting in-space communication research. New technologies being studied using the SCaN Testbed include advanced networking, coding, and modulation protocols designed to support the transition of NASAs mission systems from primarily point to point data links and preplanned routes towards adaptive, autonomous internetworked operations needed to meet future mission objectives. Networking protocols implemented on the SCaN Testbed include the Advanced Orbiting Systems (AOS) link-layer protocol, Consultative Committee for Space Data Systems (CCSDS) Encapsulation Packets, Internet Protocol (IP), Space Link Extension (SLE), CCSDS File Delivery Protocol (CFDP), and Delay-Tolerant Networking (DTN) protocols including the Bundle Protocol (BP) and Licklider Transmission Protocol (LTP). The SCaN Testbed end-to-end system provides three S-band data links and one Ka-band data link to exchange space and ground data through NASAs Tracking Data Relay Satellite System or a direct-to-ground link to ground stations. The multiple data links and nodes provide several upgradable elements on both the space and ground systems. This paper will provide a general description of the testbeds system design and capabilities, discuss in detail the design and lessons learned in the implementation of the network protocols, and describe future plans for continuing research to meet the communication needs for evolving global space systems.

space networks↗

Cache coherence for processing in memory

A cache coherence bridge protocol provides an interface between a cache coherence protocol of a host processor and a cache coherence protocol of a processor-in-memory, thereby decoupling coherence mechanisms of the host processor and the processor-in-memory. The cache coherence bridge protocol requires limited change to existing host processor cache coherence protocols. The cache coherence bridge protocol may be used to facilitate interoperability between host processors and processor-in-memory devices designed by different vendors and both the host processors and processor-in-memory devices may implement coherence techniques among computing units within each processor. The cache coherence bridge protocol may support different granularity of cache coherence permissions than those used by cache coherence protocols of a host processor and/or a processor-in-memory. The cache coherence bridge protocol uses a shadow directory that maintains status information indicating an aggregate view of copies of data cached in a system external to a processor-in-memory containing that data.

97 MATHEMATICS AND COMPUTING↗

Simulation Modeling and Performance Evaluation of Space Networks

In space exploration missions, the coordinated use of spacecraft as communication relays increases the efficiency of the endeavors. To conduct trade-off studies of the performance and resource usage of different communication protocols and network designs, JPL designed a comprehensive extendable tool, the Multi-mission Advanced Communications Hybrid Environment for Test and Evaluation (MACHETE). The design and development of MACHETE began in 2000 and is constantly evolving. Currently, MACHETE contains Consultative Committee for Space Data Systems (CCSDS) protocol standards such as Proximity-1, Advanced Orbiting Systems (AOS), Packet Telemetry/Telecommand, Space Communications Protocol Specification (SCPS), and the CCSDS File Delivery Protocol (CFDP). MACHETE uses the Aerospace Corporation s Satellite Orbital Analysis Program (SOAP) to generate the orbital geometry information and contact opportunities. Matlab scripts provide the link characteristics. At the core of MACHETE is a discrete event simulator, QualNet. Delay Tolerant Networking (DTN) is an end-to-end architecture providing communication in and/or through highly stressed networking environments. Stressed networking environments include those with intermittent connectivity, large and/or variable delays, and high bit error rates. To provide its services, the DTN protocols reside at the application layer of the constituent internets, forming a store-and-forward overlay network. The key capabilities of the bundling protocols include custody-based reliability, ability to cope with intermittent connectivity, ability to take advantage of scheduled and opportunistic connectivity, and late binding of names to addresses. In this presentation, we report on the addition of MACHETE models needed to support DTN, namely: the Bundle Protocol (BP) model. To illustrate the use of MACHETE with the additional DTN model, we provide an example simulation to benchmark its performance. We demonstrate the use of the DTN protocol and discuss statistics gathered concerning the total time needed to simulate numerous bundle transmissions

network protocols↗

Selective Enrichment Coupled with Proteomics to Identify S-Acylated Plasma Membrane Proteins in Arabidopsis

Protein S-acylation, predominately in the form of palmitoylation, is a reversible lipid post-translational modification (PTM) on cysteines that plays important roles in protein localization, trafficking, activity, and complex assembly. The functions and regulatory mechanisms of Sacylation have been extensively studied in mammals, owing to remarkable development of the high-resolution proteomics and the discovery of the S-acylation-related enzymes. However, the advance of S-acylation studies in plants lags farther behind than that in mammals, mainly due to the lack of knowledge about proteins responsible for this process, such as protein acyltransferases (PATs) and their substrates. In this article, a systematic protocol to study global S-acylation in Arabidopsis seedlings is described. The procedures are presented in detail, including preparation of Arabidopsis seedlings, enrichment of plasma membrane (PM) proteins, followed by enrichment of S-acylated proteins/peptides based on the acyl-biotin exchange (ABE) method, and large-scale identification of S-acylated proteins/peptides via mass spectrometry. This approach enables researchers to study S-acylation of PM proteins in plants in a systematic and straightforward way. Basic protocol 1: Preparation of Arabidopsis seedling materials Basic protocol 2: Isolation and enrichment of plasma membrane proteins Support protocol 1: Determination of protein concentration using BCA assay Basic Protocol 3: Enrichment of S-acylated proteins by ABE method Support protocol 2: Protein precipitation by methanol/chloroform method Basic Protocol 4: Trypsin digestion and proteomic analysis Alternate protocol 1: Pre-resin digestion and peptide level enrichment.

S-acylation, palmitoylation, plasma membrane prote↗

Effect of Intensity Modulated Radiation Therapy With Concurrent Chemotherapy on Survival for Patients With Cervical Esophageal Carcinoma

Purpose: We evaluated the effect of consecutive protocols on overall survival (OS) for cervical esophageal carcinoma (CEC). Methods and Materials: All CEC cases that received definitive radiation therapy (RT) with or without chemotherapy from 1997 to 2013 in 3 consecutive protocols were reviewed. Protocol 1 (P1) consisted of 2-dimensional RT of 54 Gy in 20 fractions with 5-fluorouracil plus either mitomycin C or cisplatin. Protocol 2 (P2) consisted of 3-dimensional conformal RT (3DRT) of ≥60 Gy in 30 fractions plus elective nodal irradiation plus cisplatin. Protocol 3 (P3) consisted of intensity modulated RT (IMRT) of ≥60 Gy in 30 fractions plus elective nodal irradiation plus cisplatin. Multivariable analyses were used to assess the effect of the treatment protocol, RT technique, and RT dose on OS, separately. Results: Of 81 cases (P1, 21; P2, 23; and P3, 37), 34 local (P1, 11 [52%]; P2, 12 [52%]; and P3, 11 [30%]), 16 regional (P1, 6 [29%]); P2, 3 [13%]; and P3, 7 [19%]), and 34 distant (P1, 10 [48%]; P2, 9 [39%]; and P3, 15 [41%]) failures were identified. After adjusting for age (P=.49) and chemotherapy (any vs none; hazard ratio [HR] 0.5, 95% confidence interval [CI] 0.3-0.9; P=.023), multivariable analysis showed P3 had improved OS compared with P1 (HR 0.4, 95% CI 0.2-0.8; P=.005), with a trend shown for benefit compared with P2 (HR 0.6, 95% CI 0.3-1.0; P=.061). OS between P1 and P2 did not differ (P=.29). Analyzed as a continuous variable, higher RT doses were associated with a borderline improved OS (HR 0.97, 95% CI 0.95-1.0; P=.075). IMRT showed improved OS compared with non-IMRT (HR 0.57, 95% CI 0.3-0.8; P=.008). Conclusions: The present retrospective consecutive cohort study showed improved OS with our current protocol (P3; high-dose IMRT with concurrent high-dose cisplatin) compared with historical protocols. The outcomes for patients with CEC remain poor, and novel approaches to improve the therapeutic ratio are warranted.

62 RADIOLOGY AND NUCLEAR MEDICINE↗