Search NASA⌕ Search

SEARCH · Search NASA

Results for “RECOMMENDATIONS”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,423 records · Page 79

Understanding and Modeling Pooled Rideshare Acceptance: Influential Factors, Preferred User Experiences, and Implications

Ridesharing allows people to share a vehicle with others traveling in the same direction, which can reduce costs and traffic congestion. Pooled rideshare (PR) services, such as UberX Share and Lyft Shared, offer an economical and environmentally friendly alternative by matching passengers traveling similar routes. However, despite these benefits, PR adoption remains low due to concerns about safety, privacy, and convenience. This research explores the factors influencing PR adoption and provides recommendations to improve user acceptance. A nationwide survey of 5,385 participants across the U.S. was conducted to understand why people choose or avoid PR. The study identified five key factors influencing PR consideration: safety, service experience, privacy, traffic/environment, and time/cost. Additional research examined ways to optimize PR experiences by identifying four critical factors: comfort/ease of use, convenience, vehicle technology/accessibility, and passenger safety. To measure the impact of these factors, a statistical model called the Pooled Rideshare Acceptance Model (PRAM) was developed, providing insights into how each element influences PR adoption. Further analysis using the Pooled Rideshare Acceptance Model Multigroup Analyses (PRAMMA) revealed how demographic characteristics such as age, gender, income, and past rideshare experience shape PR perceptions. Some key findings from the multigroup analyses showed that younger users valued technological features and environmental benefits, while older users prioritized reliability and service transparency. Additionally, privacy concerns were more significant for female users, while convenience was critical for higher-income groups. These results emphasize that a 'onesize-fits-all' approach to PR service design is not effective, highlighting the need for tailored strategies to address different user segments. Further, workshops were conducted with researchers and students to translate the findings into real-world solutions. These workshops and 3 all the statistical analyses led to the development of 95 actionable recommendations. The recommendations focus on key areas such as safety, service reliability, user education, and accessibility, offering tangible improvements to PR services. The insights from this study provide valuable guidance for policymakers, transportation network companies (TNCs), and researchers aiming to make PR services safer, more accessible, and widely accepted. By addressing user concerns, PR can become a more viable transportation option, supporting sustainable urban mobility and reducing reliance on private vehicles. Additionally, these findings emphasize the importance of user-centric service design in encouraging broader PR adoption. Future research should explore evolving trends in PR preferences, technological advancements, and policy changes to ensure continued improvements. By implementing these recommendations, PR services can better align with user expectations, enhance trust in shared mobility, and contribute to a more efficient transportation ecosystem.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Global Nuclear Energy Partnership Waste Treatment Baseline

The Global Nuclear Energy Partnership program (GNEP) is designed to demonstrate a proliferation-resistant and sustainable integrated nuclear fuel cycle that can be commercialized and used internationally. Alternative stabilization concepts for byproducts and waste streams generated by fuel recycling processes were evaluated and a baseline of waste forms was recommended for the safe disposition of waste streams. Waste forms are recommended based on the demonstrated or expected commercial practicability and technical maturity of the processes needed to make the waste forms, and performance of the waste form materials when disposed. Significant issues remain in developing technologies to process some of the wastes into the recommended waste forms, and a detailed analysis of technology readiness and availability may lead to the choice of a different waste form than what is recommended herein. Evolving regulations could also affect the selection of waste forms.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Evaluating the Long-Term Safety of a Repository at Yucca Mountain

Regulations require that the repository be evaluated for its health and safety effects for 10,000 years for the Site Recommendation process. Regulations also require potential impacts to be evaluated for up to a million years in an Environmental Impact Statement. The Yucca Mountain Project is in the midst of the Site Recommendation process. The Total System Performance Assessment (TSPA) that supports the Site Recommendation evaluated safety for these required periods of time. Results showed it likely that a repository at this site could meet the licensing requirements promulgated by the Nuclear Regulatory Commission. The TSPA is the tool that integrates the results of many years of scientific investigations with design information to allow evaluations of potential far-future impacts of building a Yucca Mountain repository. Knowledge created in several branches of physics is part of the scientific basis of the TSPA that supports the Site Recommendation process.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Heavy quarkonium: progress, puzzles, and opportunities

A golden age for heavy-quarkonium physics dawned a decade ago, initiated by the confluence of exciting advances in quantum chromodynamics (QCD) and an explosion of related experimental activity. The early years of this period were chronicled in the Quarkonium Working Group (QWG) CERN Yellow Report (YR) in 2004, which presented a comprehensive review of the status of the field at that time and provided specific recommendations for further progress. However, the broad spectrum of subsequent breakthroughs, surprises, and continuing puzzles could only be partially anticipated. Since the release of the YR, the BESII program concluded only to give birth to BESIII; the B -factories and CLEO-c flourished; quarkonium production and polarization measurements at HERA and the Tevatron matured; and heavy-ion collisions at RHIC have opened a window on the deconfinement regime. All these experiments leave legacies of quality, precision, and unsolved mysteries for quarkonium physics, and therefore beg for continuing investigations at BESIII, the LHC, RHIC, FAIR, the Super Flavor and/or Tau-Charm factories, JLab, the ILC, and beyond. The list of newly found conventional states expanded to include h c (1 P ), χ c2 (2 P ), B $ +\atop{c}$, and η b (1 S ). In addition, the unexpected and still-fascinating X (3872) has been joined by more than a dozen other charmonium- and bottomonium-like " XYZ " states that appear to lie outside the quark model. Many of these still need experimental confirmation. The plethora of new states unleashed a flood of theoretical investigations into new forms of matter such as quark-gluon hybrids, mesonic molecules, and tetraquarks. Measurements of the spectroscopy, decays, production, and in-medium behavior of $ c\bar{a}$, $ b\bar{e}$, and $ b\bar{a}$ bound states have been shown to validate some theoretical approaches to QCD and highlight lack of quantitative success for others. Lattice QCD has grown from a tool with computational possibilities to an industrial-strength effort now dependent more on insight and innovation than pure computational power. New effective field theories for the description of quarkonium in different regimes have been developed and brought to a high degree of sophistication, thus enabling precise and solid theoretical predictions. Many expected decays and transitions have either been measured with precision or for the first time, but the confusing patterns of decays, both above and below open-flavor thresholds, endure and have deepened. The intriguing details of quarkonium suppression in heavy-ion collisions that have emerged from RHIC have elevated the importance of separating hot- and coldnuclear- matter effects in quark-gluon plasma studies. This review systematically addresses all these matters and concludes by prioritizing directions for ongoing and future efforts.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Establishing advanced practice for medical imaging in New Zealand

Introduction: This article presents the outcome and recommendations following the second stage of a role development project conducted on behalf of the New Zealand Institute of Medical Radiation Technology (NZIMRT). The study sought to support the development of profiles and criteria that may be used to formulate Advanced Scopes of Practice for the profession. It commenced in 2011, following on from initial research that occurred between 2005 and 2008 investigating role development and a possible career structure for medical radiation technologists (MRTs) in New Zealand (NZ). Methods: The study sought to support the development of profiles and criteria that could be used to develop Advanced Scopes of Practice for the profession through inviting 12 specialist medical imaging groups in NZ to participate in a survey. Results: Findings showed strong agreement on potential profiles and on generic criteria within them; however, there was less agreement on specific skills criteria within specialist areas. Conclusions: The authors recommend that one Advanced Scope of Practice be developed for Medical Imaging, with the establishment of generic and specialist criteria. Systems for approval of the overall criteria package for any individual Advanced Practitioner (AP) profile, audit and continuing professional development requirements need to be established by the Medical Radiation Technologists Board (MRTB) to meet the local needs of clinical departments. It is further recommended that the NZIMRT and MRTB promote and support the need for an AP pathway for medical imaging in NZ.

61 RADIATION PROTECTION AND DOSIMETRY↗

Advancing practice relating to SEA alternatives

Developing and assessing alternatives is a key and central stage to Strategic Environmental Assessment (SEA). However, research has repeatedly reported this stage as one of the most poorly undertaken aspects of the SEA process. Current practice limitations include belated consideration of reasonable alternatives, narrow scope of alternatives that often include unrealistic or retrofitted options, limited stakeholder and public involvement in their identification, assessment and selection, lack of systematic approaches to their assessment and comparison, and inadequate reporting of the ‘storyline’ on how they were identified, what the potential impacts are and why the preferred alternative was selected. These issues have resulted in objections and judicial reviews. On the positive side, a number of good practice case studies enable extraction of key lessons and formulation of a set of general recommendations to advance practice in SEA alternatives. In this paper, practical guidance on the identification and development of alternatives, their assessment and comparison, selection of the preferred option, and documentation of the process and the reasons for selection is provided and discussed to frame good practice approaches. - Highlights: • Alternatives are one of the most poorly completed aspects of Strategic Environmental Assessment. • Current practice limitations need to be addressed to enhance SEA effectiveness. • A set of recommendations are extracted from good practice case studies. • These recommendations can be applied across jurisdictions and sectors and tailored as necessary.

54 ENVIRONMENTAL SCIENCES↗

Designing Targets for Elective Nodal Irradiation in Lung Cancer Radiotherapy: A Planning Study

Purpose: To assess doses received by mediastinal and hilar lymph node stations (LNS) delineated according to published recommendations when 'standard' two-dimensional (2D) elective fields are applied and to assess doses to critical structures when fields are designed using 2D and three-dimensional (3D) treatment planning for elective irradiation. Methods and Materials: LNS were delineated on axial CT scans according to existing recommendations. For each case and tumor location, 2D anteroposterior-posteroanterior (AP-PA) elective fields were applied using the AP-PA CT topograms. From the 2D portal fields, 3D dose distributions were then calculated to particular LNS. Next, 3D plans were prepared for elective nodal irradiation for tumors of different lobes. Doses for critical structures were compared for 2D and 3D plans. Results: LNS 1/2R, 1/2L, 3A, 3P, 5, 6, and 8 were not adequately covered in a substantial part of plans by standard 2D portals when guidelines for delineation were strictly followed. The magnitude of the lack of coverage increased with margin application. There was a trend for a higher yet probably still safe dose delivered to lung for 3D plans compared with 2D plans with a prescription dose of 45 Gy. Conclusions: 2D fields did not entirely cover LNS delineated according to the recommendations for 3D techniques. A strict adherence to these guidelines may lead to larger portals than traditionally constructed using 2D methods. Some modifications for clinical implementation are discussed.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Palliative Radiotherapy for Bone Metastases: An ASTRO Evidence-Based Guideline

Purpose: To present guidance for patients and physicians regarding the use of radiotherapy in the treatment of bone metastases according to current published evidence and complemented by expert opinion. Methods and Materials: A systematic search of the National Library of Medicine's PubMed database between 1998 and 2009 yielded 4,287 candidate original research articles potentially applicable to radiotherapy for bone metastases. A Task Force composed of all authors synthesized the published evidence and reached a consensus regarding the recommendations contained herein. Results: The Task Force concluded that external beam radiotherapy continues to be the mainstay for the treatment of pain and/or prevention of the morbidity caused by bone metastases. Various fractionation schedules can provide significant palliation of symptoms and/or prevent the morbidity of bone metastases. The evidence for the safety and efficacy of repeat treatment to previously irradiated areas of peripheral bone metastases for pain was derived from both prospective studies and retrospective data, and it can be safe and effective. The use of stereotactic body radiotherapy holds theoretical promise in the treatment of new or recurrent spine lesions, although the Task Force recommended that its use be limited to highly selected patients and preferably within a prospective trial. Surgical decompression and postoperative radiotherapy is recommended for spinal cord compression or spinal instability in highly selected patients with sufficient performance status and life expectancy. The use of bisphosphonates, radionuclides, vertebroplasty, and kyphoplasty for the treatment or prevention of cancer-related symptoms does not obviate the need for external beam radiotherapy in appropriate patients. Conclusions: Radiotherapy is a successful and time efficient method by which to palliate pain and/or prevent the morbidity of bone metastases. This Guideline reviews the available data to define its proper use and provide consensus views concerning contemporary controversies or unanswered questions that warrant prospective trial evaluation.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Impact of Quality Assurance Rounds in a Canadian Radiation Therapy Department

Purpose: Quality assurance (QA) programs aim to identify inconsistencies that may compromise patient care. Radiation treatment planning is a well-documented source of variation in radiation oncology, leading many organizations to recommend the implementation of QA rounds in which radiation therapy plans are peer reviewed. This study evaluates the outcome of QA rounds that have been conducted by a radiation therapy department since 2004. Methods and Materials: Prospectively documented records of QA rounds, from 2004 to 2010, were obtained. During rounds, randomly selected radiation therapy plans were peer reviewed and assigned a grade of A (adequate), B (minor suggestions of change to a plan for a future patient), or C (significant change required before the next fraction). The proportion of plans that received each recommendation was calculated, and the relationship between recommendations for each plan, tumor site, and mean years of experience of the radiation oncologist (RO) were explored. Chart reviews were performed for each plan that received a C. Results: During the study period, 1247 plans were evaluated; 6% received a B and 1% received a C. The mean RO years of experience were lower for plans graded C versus those graded A (P=.02). The tumor sites with the highest proportion of plans graded B or C were gastrointestinal (14%), lung (13%), and lymphoma (8%). The most common reasons for plans to receive a grade of C were inadequate target volume coverage (36%), suboptimal dose or fractionation (27%), errors in patient setup (27%), and overtreatment of normal tissue (9%). Conclusions: This study demonstrated that QA rounds are feasible and an important element of a radiation therapy department's QA program. Through peer review, plans that deviate from a department's expected standard can be identified and corrected. Additional benefits include identifying patterns of practice that may contribute to inconsistencies in treatment planning and the continuing education of staff members who attend.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Refusal of Curative Radiation Therapy and Surgery Among Patients With Cancer

Purpose: Surgery and radiation therapy represent the only curative options for many patients with solid malignancies. However, despite the recommendations of their physicians, some patients refuse these therapies. This study characterized factors associated with refusal of surgical or radiation therapy as well as the impact of refusal of recommended therapy on patients with localized malignancies. Methods and Materials: We used the Surveillance, Epidemiology, and End Results program to identify a population-based sample of 925,127 patients who had diagnoses of 1 of 8 common malignancies for which surgery and/or radiation are believed to confer a survival benefit between 1995 and 2008. Refusal of oncologic therapy, as documented in the SEER database, was the primary outcome measure. Multivariable logistic regression was used to investigate factors associated with refusal. The impact of refusal of therapy on cancer-specific mortality was assessed with Fine and Gray's competing risks regression. Results: In total, 2441 of 692,938 patients (0.4%) refused surgery, and 2113 of 232,189 patients (0.9%) refused radiation, despite the recommendations of their physicians. On multivariable analysis, advancing age, decreasing annual income, nonwhite race, and unmarried status were associated with refusal of surgery, whereas advancing age, decreasing annual income, Asian American race, and unmarried status were associated with refusal of radiation (P<.001 in all cases). Refusal of surgery and radiation were associated with increased estimates of cancer-specific mortality for all malignancies evaluated (hazard ratio [HR], 2.80, 95% confidence interval [CI], 2.59-3.03; P<.001 and HR 1.97 [95% CI, 1.78-2.18]; P<.001, respectively). Conclusions: Nonwhite, less affluent, and unmarried patients are more likely to refuse curative surgical and/or radiation-based oncologic therapy, raising concern that socioeconomic factors may drive some patients to forego potentially life-saving care.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

An approach for integrating toxicogenomic data in risk assessment: The dibutyl phthalate case study

An approach for evaluating and integrating genomic data in chemical risk assessment was developed based on the lessons learned from performing a case study for the chemical dibutyl phthalate. A case study prototype approach was first developed in accordance with EPA guidance and recommendations of the scientific community. Dibutyl phthalate (DBP) was selected for the case study exercise. The scoping phase of the dibutyl phthalate case study was conducted by considering the available DBP genomic data, taken together with the entire data set, for whether they could inform various risk assessment aspects, such as toxicodynamics, toxicokinetics, and dose–response. A description of weighing the available dibutyl phthalate data set for utility in risk assessment provides an example for considering genomic data for future chemical assessments. As a result of conducting the scoping process, two questions—Do the DBP toxicogenomic data inform 1) the mechanisms or modes of action?, and 2) the interspecies differences in toxicodynamics?—were selected to focus the case study exercise. Principles of the general approach include considering the genomics data in conjunction with all other data to determine their ability to inform the various qualitative and/or quantitative aspects of risk assessment, and evaluating the relationship between the available genomic and toxicity outcome data with respect to study comparability and phenotypic anchoring. Based on experience from the DBP case study, recommendations and a general approach for integrating genomic data in chemical assessment were developed to advance the broader effort to utilize 21st century data in risk assessment. - Highlights: • Performed DBP case study for integrating genomic data in risk assessment • Present approach for considering genomic data in chemical risk assessment • Present recommendations for use of genomic data in chemical risk assessment.

60 APPLIED LIFE SCIENCES↗

Future waste treatment and energy systems – examples of joint scenarios

Highlights: • Approach for use of scenarios dealing with both waste management and energy issues. • Overall scenarios for the common project and sub-scenarios in parts of the project. • Combining different types of scenarios to the tools of different disciplines. • Use of explorative external scenarios based on marginals for consequential LCA. - Abstract: Development and use of scenarios for large interdisciplinary projects is a complicated task. This article provides practical examples of how it has been carried out in two projects addressing waste management and energy issues respectively. Based on experiences from the two projects, recommendations are made for an approach concerning development of scenarios in projects dealing with both waste management and energy issues. Recommendations are given to develop and use overall scenarios for the project and leave room for sub-scenarios in parts of the project. Combining different types of scenarios is recommended, too, in order to adapt to the methods and tools of different disciplines, such as developing predictive scenarios with general equilibrium tools and analysing explorative scenarios with energy system analysis tools. Furthermore, as marginals identified in differing future background systems determine the outcomes of consequential life cycle assessments (LCAs), it is considered advisable to develop and use explorative external scenarios based on possible marginals as a framework for consequential LCAs. This approach is illustrated using an on-going Danish research project.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Third-party brachytherapy source calibrations and physicist responsibilities: Report of the AAPM Low Energy Brachytherapy Source Calibration Working Group

The AAPM Low Energy Brachytherapy Source Calibration Working Group was formed to investigate and recommend quality control and quality assurance procedures for brachytherapy sources prior to clinical use. Compiling and clarifying recommendations established by previous AAPM Task Groups 40, 56, and 64 were among the working group's charges, which also included the role of third-party handlers to perform loading and assay of sources. This document presents the findings of the working group on the responsibilities of the institutional medical physicist and a clarification of the existing AAPM recommendations in the assay of brachytherapy sources. Responsibility for the performance and attestation of source assays rests with the institutional medical physicist, who must use calibration equipment appropriate for each source type used at the institution. Such equipment and calibration procedures shall ensure secondary traceability to a national standard. For each multi-source implant, 10% of the sources or ten sources, whichever is greater, are to be assayed. Procedures for presterilized source packaging are outlined. The mean source strength of the assayed sources must agree with the manufacturer's stated strength to within 3%, or action must be taken to resolve the difference. Third party assays do not absolve the institutional physicist from the responsibility to perform the institutional measurement and attest to the strength of the implanted sources. The AAPM leaves it to the discretion of the institutional medical physicist whether the manufacturer's or institutional physicist's measured value should be used in performing dosimetry calculations.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Enhancements to commissioning techniques and quality assurance of brachytherapy treatment planning systems that use model-based dose calculation algorithms

The current standard for brachytherapy dose calculations is based on the AAPM TG-43 formalism. Simplifications used in the TG-43 formalism have been challenged by many publications over the past decade. With the continuous increase in computing power, approaches based on fundamental physics processes or physics models such as the linear-Boltzmann transport equation are now applicable in a clinical setting. Thus, model-based dose calculation algorithms (MBDCAs) have been introduced to address TG-43 limitations for brachytherapy. The MBDCA approach results in a paradigm shift, which will require a concerted effort to integrate them properly into the radiation therapy community. MBDCA will improve treatment planning relative to the implementation of the traditional TG-43 formalism by accounting for individualized, patient-specific radiation scatter conditions, and the radiological effect of material heterogeneities differing from water. A snapshot of the current status of MBDCA and AAPM Task Group reports related to the subject of QA recommendations for brachytherapy treatment planning is presented. Some simplified Monte Carlo simulation results are also presented to delineate the effects MBDCA are called to account for and facilitate the discussion on suggestions for (i) new QA standards to augment current societal recommendations, (ii) consideration of dose specification such as dose to medium in medium, collisional kerma to medium in medium, or collisional kerma to water in medium, and (iii) infrastructure needed to uniformly introduce these new algorithms. Suggestions in this Vision 20/20 article may serve as a basis for developing future standards to be recommended by professional societies such as the AAPM, ESTRO, and ABS toward providing consistent clinical implementation throughout the brachytherapy community and rigorous quality management of MBDCA-based treatment planning systems.

60 APPLIED LIFE SCIENCES↗

Verification of monitor unit calculations for non-IMRT clinical radiotherapy: Report of AAPM Task Group 114

The requirement of an independent verification of the monitor units (MU) or time calculated to deliver the prescribed dose to a patient has been a mainstay of radiation oncology quality assurance. The need for and value of such a verification was obvious when calculations were performed by hand using look-up tables, and the verification was achieved by a second person independently repeating the calculation. However, in a modern clinic using CT/MR/PET simulation, computerized 3D treatment planning, heterogeneity corrections, and complex calculation algorithms such as convolution/superposition and Monte Carlo, the purpose of and methodology for the MU verification have come into question. In addition, since the verification is often performed using a simpler geometrical model and calculation algorithm than the primary calculation, exact or almost exact agreement between the two can no longer be expected. Guidelines are needed to help the physicist set clinically reasonable action levels for agreement. This report addresses the following charges of the task group: (1) To re-evaluate the purpose and methods of the ''independent second check'' for monitor unit calculations for non-IMRT radiation treatment in light of the complexities of modern-day treatment planning. (2) To present recommendations on how to perform verification of monitor unit calculations in a modern clinic. (3) To provide recommendations on establishing action levels for agreement between primary calculations and verification, and to provide guidance in addressing discrepancies outside the action levels. These recommendations are to be used as guidelines only and shall not be interpreted as requirements.

60 APPLIED LIFE SCIENCES↗

SU-E-T-205: Improving Quality Assurance of HDR Brachytherapy: Verifying Agreement Between Planned and Delivered Dose Distributions Using DICOM RTDose and Advanced Film Dosimetry

Purpose: HDR brachytherapy is undergoing significant development, and quality assurance (QA) checks must keep pace. Current recommendations do not adequately verify delivered against planned dose distributions: This is particularly relevant for new treatment planning system (TPS) calculation algorithms (non TG-43 based), and an era of significant patient-specific plan optimisation. Full system checks are desirable in modern QA recommendations, complementary to device-centric individual tests. We present a QA system incorporating TPS calculation, dose distribution export, HDR unit performance, and dose distribution measurement. Such an approach, more common in external beam radiotherapy, has not previously been reported in the literature for brachytherapy. Methods: Our QA method was tested at 24 UK brachytherapy centres. As a novel approach, we used the TPS DICOM RTDose file export to compare planned dose distribution with that measured using Gafchromic EBT3 films placed around clinical brachytherapy treatment applicators. Gamma analysis was used to compare the dose distributions. Dose difference and distance to agreement were determined at prescription Point A. Accurate film dosimetry was achieved using a glass compression plate at scanning to ensure physically-flat films, simultaneous scanning of known dose films with measurement films, and triple-channel dosimetric analysis. Results: The mean gamma pass rate of RTDose compared to film-measured dose distributions was 98.1% at 3%(local), 2 mm criteria. The mean dose difference, measured to planned, at Point A was -0.5% for plastic treatment applicators and -2.4% for metal applicators, due to shielding not accounted for in TPS. The mean distance to agreement was 0.6 mm. Conclusion: It is recommended to develop brachytherapy QA to include full-system verification of agreement between planned and delivered dose distributions. This is a novel approach for HDR brachytherapy QA. A methodology using advanced film dosimetry and gamma comparison to DICOM RTDose files has been demonstrated as suitable to fulfil this need.

07 ISOTOPE AND RADIATION SOURCES↗

TU-B-19A-01: Image Registration II: TG132-Quality Assurance for Image Registration

AAPM Task Group 132 was charged with a review of the current approaches and solutions for image registration in radiotherapy and to provide recommendations for quality assurance and quality control of these clinical processes. As the results of image registration are always used as the input of another process for planning or delivery, it is important for the user to understand and document the uncertainty associate with the algorithm in general and the Result of a specific registration. The recommendations of this task group, which at the time of abstract submission are currently being reviewed by the AAPM, include the following components. The user should understand the basic image registration techniques and methods of visualizing image fusion. The disclosure of basic components of the image registration by commercial vendors is critical in this respect. The physicists should perform end-to-end tests of imaging, registration, and planning/treatment systems if image registration is performed on a stand-alone system. A comprehensive commissioning process should be performed and documented by the physicist prior to clinical use of the system. As documentation is important to the safe implementation of this process, a request and report system should be integrated into the clinical workflow. Finally, a patient specific QA practice should be established for efficient evaluation of image registration results. The implementation of these recommendations will be described and illustrated during this educational session. Learning Objectives: Highlight the importance of understanding the image registration techniques used in their clinic. Describe the end-to-end tests needed for stand-alone registration systems. Illustrate a comprehensive commissioning program using both phantom data and clinical images. Describe a request and report system to ensure communication and documentation. Demonstrate an clinically-efficient patient QA practice for efficient evaluation of image registration.

60 APPLIED LIFE SCIENCES↗

SU-E-J-211: Assessing the Consistency of the ViewRay 0.35 T MRI System

Purpose: ViewRay is a novel image-guided radiotherapy approach with an integrated 0.35 T MR unit and three Cobalt-60 heads. In order to continuously ensure the high resolution and high soft tissue contrast available in MR images, we quantified a multitude of relevant imaging parameters over a period of six months to establish its stability and imaging quality. In the assessment process, consideration is also given to the need to establish the number of tests required to have confidence in the performance of the system for radiation therapy planning applications. Methods: Daily, weekly, monthly and annual imaging tests were performed over a period of six months using standardized phantoms (a 24 cm diameter sphere and the ACR phantom) to quantify the performance of the system. In addition to the ACR and NEMA recommended tests, we also included element testing, spatial integrity, Eddy current and magnetic field inhomogeneity measurements. The ACR test is used for assessing the following parameters for T1 and T2: geometric accuracy, high contrast spatial resolution, slice thickness accuracy, slice position accuracy, percent signal ghosting, low contrast object detectability. It also includes percent image uniformity (PIU) for T1. The NEMA test is primarily designed to check SNR and PIU. Results: Over the period of six months, all the parameters were maintained within the recommendations provided in the ACR and NEMA standards. PIU and SNR were found to be sensitive to malfunctions in the components of the multileaf collimators. Details of the findings will be presented. Conclusion: The data suggests that ViewRay imaging system has functioned in a consistent and reliable manner. MR imaging from ViewRay 0.35T system complies with the ACR and NEMA recommended acceptance standards.

60 APPLIED LIFE SCIENCES↗