Search NASA⌕ Search

SEARCH · Search NASA

Results for “RESIDENTIAL”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,423 records · Page 79

Residential Split Heat Pump Using Low GWP Refrigerants

Conventional refrigerants, e.g. R-410A have high global warming potentials (GWP) > 1800. They are being phased out to protect the environment. The candidates to replace R-410A include R-32, R-452B, R-454B and R-466A for heat pump applications. These candidates are intended for drop-in replacement, i.e. having minimum modifications on existing systems. The paper investigates the low GWP refrigerants drop-in application via system simulations using a well-regarded, hardware-based heat pump model. A baseline heat pump having all fin-and-tube heat exchangers and a two-speed compressor was used. Cross-comparisons were made under rated conditions of ambient temperatures, compressor speeds, indoor air flow rates, respectively for cooling and heating operations. The seasonal performance indices, i.e. SEER and HSPF are presented.

Shen, Bo↗

New Residential Construction Carbon Emissions

This fact sheet will help homebuilders better understand the largest sources of carbon emissions in constructed homes and see the comparative impact of those sources on overall emissions. Opportunities are highlighted for innovation and carbon reduction through material choices.

carbon emissions↗

Impacts of Thawing Permafrost on Residential Infrastructure: Results and Resources

Permafrost underlies approximately 20% of the landmass in the Northern Hemisphere. Inevitably human infrastructure has been and will be built on permafrost; however, due to climate change, the permafrost in many regions has begun to thaw. Using past reports and surveys as guidance, a survey was conducted to track the effects of permafrost thaw on housing infrastructure in the community of Point Lay, Alaska. The Cold Climate Housing Research Center, Inc. and the National Renewable Energy Lab conducted a literature review and interviews to document community issues from thawing permafrost and identify potential mitigation strategies for existing and new infrastructure. Researchers also identified strategies for individual homeowners to inspect their foundations for current issues or anticipate future ones. This poster will cover the results from the survey on the effects of permafrost thawing to Point Lay and include permafrost basics, common concerns from thawing permafrost, steps to identify permafrost sites and visible signs of permafrost degradation, and potential mitigation strategies that may be beneficial to Alaskans and increase resilience in the Arctic.

Alaska↗

Acidic Gas Reduction For Residential Natural Gas Furnace

The United States has more than 119 million homes, and 47% of them rely on natural gas as their primary heating fuel. However, most U.S. homes still use noncondensing units with an annual fuel utilization efficiency (AFUE) of ~80%, rather than efficient condensing furnaces. This is due to the high cost of condensing furnaces, which usually use expensive corrosion resistant super-ferritic stainless steel alloy heatexchangers (HX) to avoid corrosion and fouling acid condensation, along with the cost and difficulty of retrofitting the venting used by the replaced furnace. Here, this article discusses a low-cost acidic gas reduction (AGR) catalyst technology that enables a novel condensing natural gas furnace with an ultraclean (i.e., nearly zero) flue gas and neutral condensate that is environmentally friendly.

03 NATURAL GAS↗

Case Studies of Residential Façade Upgrades in Four Climate Zones

This paper reports on a project that explored the viability of insulation and window upgrades during siding retrofits in four case studies across the United States. Thousands of homes are re-sided every year, but only a fraction of consumers add insulation and upgrade the windows at the same time, even though a siding replacement is the ideal time to update the thermal performance of building enclosures. To better understand why more siding retrofits do not include insulation and window upgrades, research staff from several organizations collaborated with the U.S. Department of Energy on a multi-faceted research project that included a cost analysis, workforce analysis, market assessment, and contractor assessment. This paper will review four in-field case studies conducted with contractors actively engaged in home re-siding projects that agreed to add rigid insulation and window upgrades as part of their projects. Findings from the case studies will be presented including contractor perspectives, cost, and technical approaches on projects, located in multiple climate zones including Bellingham WA, Jackson MS, Kalamazoo MI, and Phoenix AZ. All projects involved adding continuous rigid insulation on the exterior walls and installation of new cladding. Cladding types varied from wood and metal to fiber cement, vinyl, and traditional stucco. All homes also received a window upgrade, although upgrades varied depending on the original condition of the windows and climate; upgrades included triple-pane windows, low-e storm windows, and exterior shading. Key findings including technical approaches, opportunities, barriers, and project cost will be presented.

re-siding, insulation, rigid insulation, exterior ↗

Indoor Radon Measurements from Residential Buildings with Basements in a Community with Potential LLRW Contamination - 19566

The Port Hope Area Initiative (PHAI) represents the Government of Canada's commitment to the cleanup and safe, local, long-term management of historic low-level radioactive waste (LLRW) in two Southern Ontario municipalities-Port Hope and Clarington. The PHAI (see reference for internet address) is based on community-recommended solutions for the cleanup and safe long-term management of approximately 1.7 million cubic meters of LLRW. It is currently one of Canada's largest environmental remediation projects at a cost of over one billion dollars. Canadian Nuclear Laboratories (CNL) is implementing the PHAI on behalf of Atomic Energy of Canada Limited, a Federal Crown Corporation. An initial characterization and remediation program in the urban area of Port Hope was conducted from 1976 to 1981. The waste is the result of radium and uranium processing in Port Hope by the former Federal Crown Corporation Eldorado Nuclear Limited between 1933 and 1988. One contaminant of concern in the LLRW is radium-226 (Ra-226) which may lead to elevated indoor levels of radon-222 (Rn-222) indoors. As part of CNL's implementation of the PHAI, Arcadis is conducting the Port Hope Project Property Radiological Survey of approximately 4,800 small-scale sites to identify 1) properties that have not been affected by historic operations and 2) properties that have residual historic low-level radioactive waste impacts requiring remediation either for soils or for interior contamination or both. Over the last six years, a component of the Small Scale Sites (SSS) characterization surveys have measured radon concentrations in essentially all buildings in Port Hope using alpha-track detectors. All properties had subsurface characterization including analytical characterization and lithology following the radon measurement reporting to measure if soil concentrations exceeded the PHAI Cleanup Criteria (PHAI CC) for Ra-226 of 0.29 Bq/g. Buildings with radon gas exceeding a trigger level of 200 becquerels per cubic meter (Bq/m{sup 3}) or those with ventilation systems required investigation of soil concentrations around the perimeter of the building. Ra-226 concentrations above the background level of 0.05 Bq/g due to LLRW sources were forwarded to create remedial action plans (RAPs) to remove the contamination near the building. The SSS surveys provide a substantive data set on the approximately 3,000 properties measured to date with interior Rn-222 gas measurements and descriptions of the physical characteristics of the buildings, the lithology of soils near the buildings and the measurements of Ra-226 concentration in the soils on the property. Consideration of the potential for contribution from non-LLRW Ra-226 from natural sources or coal ash was required on some properties. This paper describes the data and exploratory analysis of the relationship(s) between LLRW and non-LLRW factors that affect the variation in indoor radon concentrations. Historical information on the urban area, the measured Ra-226 concentration and the age of the building were correlated with radon concentrations. A large variety of native soils are found in the complex terrain and the type of native soil was correlated with the radon concentrations. A statistical analysis to address the impact of co-related explanatory variables to model indoor radon concentrations is planned when the SSS activities are complete. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

An Open-Source Framework for Characterizing Urban Energy Models: Integrating Top-Down and Bottom-Up Methods to Predict Residential Buildings Characteristics: Preprint

Bottom-up urban energy models are crucial for understanding current energy use patterns and informing design strategies. However, accurately characterizing these models to represent different communities remains a challenge due to the extensive data needed for simulating existing energy use behavior. This data includes information related to human activities and building characteristics, all of which correlate with socioeconomic factors. To overcome this challenge, we developed an automated framework that utilizes both top-down and bottom-up data, to predict unknown building and occupant characteristics that are needed for more accurate and equitable modeling and analytics. Our framework, integrated into the URBANopt district energy modeling platform, uses statistical data models from ResStock. URBANopt models co-located buildings and neighborhoods. At this scale there are data gaps in building characteristic data, such as materials, insulation, occupancy, income, and energy usage of the buildings. To address this data gap, we use ResStock data, representative at the census tract scale, and develop machine-learning and deeplearning techniques to disaggregate it to individual buildings. By mapping unique occupant, building and economic properties to URBANopt energy models, we gain detailed insights into the variability of building energy use across different neighborhoods. This insight helps deploy technologies for co-located buildings and supports targeted upgrades for communities with unique economic and demographic characteristics, ensuring energy equity. Accurate characterization of energy models allows us to develop equitable strategies tailored to diverse neighborhoods, whether underserved or affluent. Our automated framework streamlines energy modeling and provides a reliable tool for building energy characterization.

ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATION↗

Benchmark Testing of Two Residential Refrigerators Using R-600a

Household refrigerators provide a convenient and safe means of food preservation and storage. More than 100 million refrigerators are used in US homes, resulting in significant primary energy consumption and carbon emissions. As a greenhouse gas with a 100-year global warming potential of 1,430, R-134a has been banned in new US domestic refrigerators and freezers since 2021, and R-600a with a global warming potential of 3 is widely employed as a working fluid in the current US household refrigerator market. In this paper, benchmark testing was conducted for two 2023 refrigerators using R-600a. Moreover, the effect of representative customer use patterns, such as door opening and warm food storage, was studied to evaluate the effect on the energy consumption of the refrigerators. These results will provide background knowledge for facilitating the integration of new technologies to achieve significantly reduced greenhouse gas emissions in future efficient refrigerators.

Gao, Zhiming↗

Short-Term Electric Load Forecasting for a Residential Household in Alaska

Accurate short-term load forecasting at a fine scale is essential for demand response programs, peak shaving, and load-shedding strategies [1]. While traditionally, only aggregate short-term consumption data was available, advanced metering infrastructure (AMI) now provides data at the individual consumer level [1]. There is increasing interest in utilizing this data for short-term load forecasting (from an hour to a few days) to optimize grid operations. Electricity consumption in individual households is highly influenced by residents’ personal behaviors [2]. As a result, unlike aggregate loads, electrical power usage in single households often shows significant volatility, making meter-level load forecasting for individual users particularly challenging [3], [4]. Deep learning methods, with their strong ability to model nonlinear data, have become popular for improving the accuracy of household electricity consumption forecasting [4]. Notably, the Long ShortTerm Memory (LSTM) has attracted significant attention [5], [6].

42 ENGINEERING↗