Search NASA⌕ Search

SEARCH · Search NASA

Results for “Radiator Performance”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,423 records · Page 79

Performance of actinide-containing fuel matrices under extreme radiation and temperature environments (Final Technical Report)

Single crystal UO 2 thin film with a buried layer of Nd in the film middle plane has been grown on Yittria Stabilized Zirconia (YSZ) substrates (1cmx1cmx0.5cm) using a reactive-gas sputtering system at 650 C. X-Ray Diffraction (XRD) analysis has been done for samples both as grown and after irradiation. Specular 2θ-ω scans from XRD measurements show single crystal feature of the UO 2 film, as shown in Fig. 3.1. Film peaks are the two low intensity, left-hand-side peaks, which are marked as (0 0 2) and (0 0 4) plane. The strong, right-hand-side peaks are from the YSZ substrates.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Material and processing needs for silicon solar cells in space

The technical concerns of NASA in the area of space grade solar cells are summarized. Solar power needs are projected through 1987. The degradation of solar cell performance due to the effects of radiation on impurities and crystal defects and the improved performance of float zone silicon are illustrated. The reduction of oxygen and carbon in float zone silicon allows for much faster low temperature annealing of the defects. The effects of improved crystal purity on cell performance are summarized.

Brandhorst, H. W., Jr.↗

Effect of an Opaque Reflecting Layer on the Thermal Behavior of a Thermal Barrier Coating

A parametric study using a two-flux approximation of the radiative transfer equation was performed to examine the effects of an opaque reflective layer on the thermal behavior of a typical semitransparent thermal barrier coating on an opaque substrate. Some ceramic materials are semitransparent in the wavelength ranges where thermal radiation is important. Even with an opaque layer on each side of the semitransparent thermal barrier coating, scattering and absorption can have an effect on the heat transfer. In this work, a thermal barrier coating that is semitransparent up to a wavelength of 5 micrometers is considered. Above 5 micrometers wavelength, the thermal barrier coating is opaque. The absorption and scattering coefficient of the thermal barrier was varied. The thermal behavior of the thermal barrier coating with an opaque reflective layer is compared to a thermal barrier coating without the reflective layer. For a thicker thermal barrier coating with lower convective loading, which would be typical of a combustor liner, a reflective layer can significantly decrease the temperature in the thermal barrier coating and substrate if the scattering is weak or moderate and for strong scattering if the absorption is large. The layer without the reflective coating can be about as effective as the layer with the reflective coating if the absorption is small and the scattering strong. For low absorption, some temperatures in the thermal barrier coating system can be slightly higher with the reflective layer. For a thin thermal barrier coating with high convective loading, which would be typical of a blade or vane that sees the hot sections of the combustor, the reflective layer is not as effective. The reflective layer reduces the surface temperature of the reflective layer for all conditions considered. For weak and moderate scattering, the temperature of the TBC-substrate interface is reduced but for strong scattering, the temperature of the substrate is increased slightly.

Spuckler, Charles M.↗

Identification of Trends into Dose Calculations for Astronauts through Performing Sensitivity Analysis on Calculational Models Used by the Radiation Health Office

The Radiation Health Office (RHO) determines each astronaut s cancer risk by using models to associate the amount of radiation dose that astronauts receive from spaceflight missions. The baryon transport codes (BRYNTRN), high charge (Z) and energy transport codes (HZETRN), and computer risk models are used to determine the effective dose received by astronauts in Low Earth orbit (LEO). This code uses an approximation of the Boltzman transport formula. The purpose of the project is to run this code for various International Space Station (ISS) flight parameters in order to gain a better understanding of how this code responds to different scenarios. The project will determine how variations in one set of parameters such as, the point of the solar cycle and altitude can affect the radiation exposure of astronauts during ISS missions. This project will benefit NASA by improving mission dosimetry.

Adams, Thomas↗

Beam commissioning results for the RFQ and MEBT of the EBIS based preinjector for RHIC

The EBIS based preinjector for both the Relativistic Heavy Ion Collider (RHIC) and NASA Space Radiation Laboratory (NSRL) is now being commissioned at Brookhaven National Laboratory (BNL). In 2008, the RFQ for the project was delivered and commissioned using Test EBIS, which was built to demonstrate the high current EBIS's performance. A dedicated beamline after the RFQ was assembled to confirm the RFQ's performance, and the beam energy was measured by a bending dipole magnet. In November 2009, the RFQ was moved to the final location and the vanes were realigned. The beam commissioning with the RHIC-EBIS was started again during March 2010. The RFQ accelerates ions from 17 keV/u to 300 keV/u and operates at 100.625 MHz. It is followed by a short Medium Energy Beam Transport (MEBT), which consists of four quadrupoles and one buncher cavity. Some temporary diagnostics for this commissioning include an emittance probe, TOF system, fast Faraday cup, and beam current measurement units. As of September 2010, the RFQ and the MEBT show expected performance with He{sup +}, Au{sup 32+} and Fe{sup 20+} beams. Further commissioning for higher intensity beams is in progress.

43 PARTICLE ACCELERATORS↗

Construction and performance of combustion beamline at NSRL

An undulator-based VUV beamline BL03U is constructed at the National Synchrotron Radiation Laboratory. Optical design and performance test results are presented in this paper. The monochromator is a Czerny–Turner configuration with a toroidal collimating mirror, two plane gratings, and a toroidal focusing mirror. Plane gratings with line densities of 200 and 400 l/mm are used to cover the photon energy range of 5–21 eV. A gas absorption spectrum is used to evaluate the beamline performance. The photon energy resolving power (E/ΔE) of the beamline is approximately 3900 at 7.3 eV for the 200 l/mm grating and 4200 at 14.6 eV for the 400 l/mm grating. The photon flux is approximately 5×10{sup 12} photons/s/300 mA at energy of 10 eV.

43 PARTICLE ACCELERATORS↗

Upconversion Er-doped TiO2 nanorod arrays for perovskite solar cells and the performance improvement

Highlights: • Er-doped TiO{sub 2} nanorod absorbs IR and converts into visible light. • The introduction of Er could make a positive shift in flat-band potential. • Er-doped TiO{sub 2} solar cells show a 20% increment in the current density. - Abstract: Upconversion erbium-doped rutile TiO{sub 2} nanorod arrays were synthesized by a facile process and applied in perovskite solar cells (PSCs). The structure was characterized by X-ray powder diffraction (XRD). Energy dispersive spectrometer (EDS) and Tauc plot indicated that Er was successfully introduced and changed TiO{sub 2} band gap from 3.00 eV to 3.07 eV. The incorporation of Er shifts the flat band potential positively and enhances the electron density. The Er-doped TiO{sub 2} nanorods have a broad absorption in the infrared light and up-convert it into visible light, which provides a possibility for PSCs to use NIR light for higher performance. A higher photocurrent density (J{sub sc}) of 22.97 mA/cm{sup 2} and a power conversion efficiency (PCE) of 10.6% were obtained, showing 20% and 16.5% increment in J{sub sc} and PCE, respectively, when compared with the un-doped device. The performance improvement was ascribed to the upconversion performance, enhanced electron-injection efficiency and reduced charge recombination.

14 SOLAR ENERGY↗

Spectral optimization for micro-CT

Purpose: To optimize micro-CT protocols with respect to x-ray spectra and thereby reduce radiation dose at unimpaired image quality. Methods: Simulations were performed to assess image contrast, noise, and radiation dose for different imaging tasks. The figure of merit used to determine the optimal spectrum was the dose-weighted contrast-to-noise ratio (CNRD). Both optimal photon energy and tube voltage were considered. Three different types of filtration were investigated for polychromatic x-ray spectra: 0.5 mm Al, 3.0 mm Al, and 0.2 mm Cu. Phantoms consisted of water cylinders of 20, 32, and 50 mm in diameter with a central insert of 9 mm which was filled with different contrast materials: an iodine-based contrast medium (CM) to mimic contrast-enhanced (CE) imaging, hydroxyapatite to mimic bone structures, and water with reduced density to mimic soft tissue contrast. Validation measurements were conducted on a commercially available micro-CT scanner using phantoms consisting of water-equivalent plastics. Measurements on a mouse cadaver were performed to assess potential artifacts like beam hardening and to further validate simulation results. Results: The optimal photon energy for CE imaging was found at 34 keV. For bone imaging, optimal energies were 17, 20, and 23 keV for the 20, 32, and 50 mm phantom, respectively. For density differences, optimal energies varied between 18 and 50 keV for the 20 and 50 mm phantom, respectively. For the 32 mm phantom and density differences, CNRD was found to be constant within 2.5% for the energy range of 21-60 keV. For polychromatic spectra and CMs, optimal settings were 50 kV with 0.2 mm Cu filtration, allowing for a dose reduction of 58% compared to the optimal setting for 0.5 mm Al filtration. For bone imaging, optimal tube voltages were below 35 kV. For soft tissue imaging, optimal tube settings strongly depended on phantom size. For 20 mm, low voltages were preferred. For 32 mm, CNRD was found to be almost independent of tube voltage. For 50 mm, voltages larger than 50 kV were preferred. For all three phantom sizes stronger filtration led to notable dose reduction for soft tissue imaging. Validation measurements were found to match simulations well, with deviations being less than 10%. Mouse measurements confirmed simulation results. Conclusions: Optimal photon energies and tube settings strongly depend on both phantom size and imaging task at hand. For in vivo CE imaging and density differences, strong filtration and voltages of 50-65 kV showed good overall results. For soft tissue imaging of animals the size of a rat or larger, voltages higher than 65 kV allow to greatly reduce scan times while maintaining dose efficiency. For imaging of bone structures, usage of only minimum filtration and low tube voltages of 40 kV and below allow exploiting the high contrast of bone at very low energies. Therefore, a combination of two filtrations could prove beneficial for micro-CT: a soft filtration allowing for bone imaging at low voltages, and a variable stronger filtration (e.g., 0.2 mm Cu) for soft tissue and contrast-enhanced imaging.

60 APPLIED LIFE SCIENCES↗

Modeling diurnal and annual ethylene generation from solar-driven electrochemical CO 2 reduction devices

Integrated solar fuels devices for CO 2 reduction (CO 2 R) are a promising technology class towards reducing carbon emissions. Designing integrated CO 2 R solar fuels devices requires careful co-design of electrochemical and photovoltaic components as well as consideration of the diurnal and seasonal effects of solar irradiance, temperature, and other meteorological factors expected for ‘on-sun’ deployment. Using a photovoltaic-electrochemical (PV-EC) platform, we developed a temperature and potential-dependent diurnal and annual model using experimentally-determined CO 2 R performance of Cu-based electrocatalysts, local meteorological data from the National Solar Radiation Database (NSRD), and modeled performance of commercial c-Si PVs. Here we simulated gaseous diurnal product outputs with and without the effects of ambient temperature. From these outputs, we observed seasonal variation in gaseous product generation, with up to two-fold increases in ethylene productivity between the Winter and Summer, analyzed the consequences of dynamic cloud coverage, and identified periods where device cooling/heating mechanisms could be implemented to maximize ethylene generation. Finally, we modeled the annual ethylene generation for a scaled 1 MW solar farm at three different locations (Beijing, CN; Sydney, AUS; Barstow, CA) to determine the consequences of local meteorological climates on PV-EC CO 2 R product output, recording a maximum ethylene output of 18.5 tonne per year at Barstow. Overall, this model presents a critical tool for streamlining the translation of experimental solar-driven electrochemical research to real-world implementation.

14 SOLAR ENERGY↗

SU-E-J-211: Assessing the Consistency of the ViewRay 0.35 T MRI System

Purpose: ViewRay is a novel image-guided radiotherapy approach with an integrated 0.35 T MR unit and three Cobalt-60 heads. In order to continuously ensure the high resolution and high soft tissue contrast available in MR images, we quantified a multitude of relevant imaging parameters over a period of six months to establish its stability and imaging quality. In the assessment process, consideration is also given to the need to establish the number of tests required to have confidence in the performance of the system for radiation therapy planning applications. Methods: Daily, weekly, monthly and annual imaging tests were performed over a period of six months using standardized phantoms (a 24 cm diameter sphere and the ACR phantom) to quantify the performance of the system. In addition to the ACR and NEMA recommended tests, we also included element testing, spatial integrity, Eddy current and magnetic field inhomogeneity measurements. The ACR test is used for assessing the following parameters for T1 and T2: geometric accuracy, high contrast spatial resolution, slice thickness accuracy, slice position accuracy, percent signal ghosting, low contrast object detectability. It also includes percent image uniformity (PIU) for T1. The NEMA test is primarily designed to check SNR and PIU. Results: Over the period of six months, all the parameters were maintained within the recommendations provided in the ACR and NEMA standards. PIU and SNR were found to be sensitive to malfunctions in the components of the multileaf collimators. Details of the findings will be presented. Conclusion: The data suggests that ViewRay imaging system has functioned in a consistent and reliable manner. MR imaging from ViewRay 0.35T system complies with the ACR and NEMA recommended acceptance standards.

60 APPLIED LIFE SCIENCES↗

Modeling Diurnal and Annual Ethylene Generation from Solar-Driven Electrochemical CO 2 Reduction Devices

Integrated solar fuels devices for CO 2 reduction (CO 2 R) are a promising technology class towards achieving net-negative carbon emissions. Designing integrated CO 2 R solar fuels devices requires careful co-design of electrochemical and photovoltaic components as well as consideration of the diurnal and seasonal effects of solar irradiance, temperature, and other meteorological factors expected for ‘on-sun’ deployment. Here, using a photovoltaic-electrochemical (PV-EC) platform, we developed a temperature and potential-dependent diurnal and annual model using experimental CO 2 R performance of Cu-based electrocatalysts, local meteorological data from the National Solar Radiation Database (NSRD), and modeled performance of commercial c-Si PVs. We simulated diurnal product outputs with and without the effects of ambient temperature to determine gaseous product temperature sensitivity. From these outputs, we observed seasonal variation in gaseous product generation, with up to two-fold increases in ethylene productivity between the Winter and Summer, analyzed the consequences of dynamic cloud coverage, and identified periods where device cooling/heating mechanisms could be implemented to maximize ethylene generation. Finally, we modeled the annual ethylene generation for a scaled 1 MW solar farm at three different locations (Beijing, CN; Sydney, AUS; Barstow, CA) to determine the consequences of local meteorological climates on PV-EC CO 2 R product output, recording a maximum ethylene output of 18.5 tonne/yr at Barstow. Overall, this model presents a critical tool for streamlining the translation of experimental solar-driven electrochemical research to real-world implementation.

Yap, Kyra M. K.↗

A laboratory investigation of the variability of cloud reflected radiance fields

A method to determine the radiative properties of complex cloud fields was developed. A Cloud field optical simulator (CFOS) was constructed to simulate the interaction of cloud fields with visible radiation. The CFOS was verified by comparing experimental results from it with calculations performed with a Monte Carlo radiative transfer model. A software library was developed to process, reduce, and display CFOS data. The CFSOS was utilized to study the reflected radiane patterns from simulated cloud fields.

Mckee, T. B.↗

NDE Technology Engineering Program for Hanford DST Non-Visual Volumetric Inspection Technology: Phase II RAVIS Radiation Tolerance Test Report

This test report provides the results of radiation tolerance robustness testing that was performed on samples of robotic components and an ultrasonic guided wave air-slot sensor that represent components/sub-systems of the Robotic Air-slot Volumetric Inspection System (RAVIS) that has been engineered for volumetric inspection of Hanford tank bottom plates via under-tank refractory pad air-slots. The specific components tested for 1) functionality during active irradiation and 2) tolerance to cumulative radiation dose (until failure or upon reaching a cumulative dose test limit) were: • four samples each of a printed circuit board (PCB) and direct current (DC) motor, which are robotic components, and • 26 ultrasonic piezoelectric elements (samples) inside an air-slot sensor. The robotic components are part of the RAVIS air-slot inspection crawler drive control system that is responsible for remote communication with and actuation of the air-slot inspection crawler. The failure of either of these components during under-tank deployment would require manual retrieval via the crawler’s tether, which risks damage to the robot/refractory/tank. Preemptive replacement of the components at appropriately conservative dose/time intervals informed by failure dose would reduce the likelihood of under-tank failure. The components were included in radiation tolerance testing to quantify their failure doses to inform replacement intervals. The air-slot sensor is responsible for collecting ultrasonic inspection data (scan images) for the tank bottom plates during under-tank deployment. Compromised signal quality due to elevated noise levels caused by gamma radiation would compromise inspection performance. The air-slot sensor was included in radiation tolerance testing to quantify the impact of active irradiation on sensor signal quality. The irradiation and in-situ functional tests of the PCBs, DC motors and air-slot sensor took place in June and July 2020 at the Pacific Northwest National Laboratory. Testing was performed at a gamma dose rate near 300 rad/hr., which, in the absence of under-tank dose rate data, has been conservatively estimated to be the upper-bound dose rate beneath the primary tanks at Hanford. Irradiation took place at elevated temperatures of 150-200°F to determine failure doses that reflect the compounding effects of gamma radiation and heat. The test results revealed: • The DC motors can tolerate being actively irradiated at the high dose rate at 200°F and can tolerate a cumulative dose of 300,000 rad, that which would be incurred after 5 years of service at the 300 rad/hr dose rate. The component therefore meets minimum and preferred radiation tolerance and lifecycle requirements for robotic components. • The air-slot sensor can tolerate being actively irradiated at the high dose rate at 150°F and can tolerate a cumulative dose of 60,000 rad, that which would be incurred after 1 year of service at the 300 rad/hr dose rate. The sensor therefore meets minimum radiation tolerance and lifecycle requirements. • The PCB can tolerate being actively irradiated at the high dose rate, but can only tolerate a cumulative dose of 19,000 rad at 150-200°F. The PCB does not meet minimum radiation tolerance and lifecycle requirements; however, because the component is considered replaceable, it can be replaced before a cumulative dose of 19,000 rad is reached, determined through either monitoring with a dosimeter or scheduled time intervals that are calculated based on conservative estimates of under-tank dose rates.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Creating NDA working standards through high-fidelity spent fuel modeling

The Next Generation Safeguards Initiative (NGSI) is developing advanced non-destructive assay (NDA) techniques for spent nuclear fuel assemblies to advance the state-of-the-art in safeguards measurements. These measurements aim beyond the capabilities of existing methods to include the evaluation of plutonium and fissile material inventory, independent of operator declarations. Testing and evaluation of advanced NDA performance will require reference assemblies with well-characterized compositions to serve as working standards against which the NDA methods can be benchmarked and for uncertainty quantification. To support the development of standards for the NGSI spent fuel NDA project, high-fidelity modeling of irradiated fuel assemblies is being performed to characterize fuel compositions and radiation emission data. The assembly depletion simulations apply detailed operating history information and core simulation data as it is available to perform high fidelity axial and pin-by-pin fuel characterization for more than 1600 nuclides. The resulting pin-by-pin isotopic inventories are used to optimize the NDA measurements and provide information necessary to unfold and interpret the measurement data, e.g., passive gamma emitters, neutron emitters, neutron absorbers, and fissile content. A key requirement of this study is the analysis of uncertainties associated with the calculated compositions and signatures for the standard assemblies; uncertainties introduced by the calculation methods, nuclear data, and operating information. An integral part of this assessment involves the application of experimental data from destructive radiochemical assay to assess the uncertainty and bias in computed inventories, the impact of parameters such as assembly burnup gradients and burnable poisons, and the influence of neighboring assemblies on periphery rods. This paper will present the results of high fidelity assembly depletion modeling and uncertainty analysis from independent calculations performed using SCALE and MCNP. This work is supported by the Next Generation Safeguards Initiative, Office of Nuclear Safeguards and Security, National Nuclear Security Administration.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

High-stability compact atomic clock based on isotropic laser cooling

We present a compact cold-atom clock configuration where isotropic laser cooling, microwave interrogation, and clock signal detection are successively performed inside a spherical microwave cavity. For ground operation, a typical Ramsey fringe width of 20 Hz has been demonstrated, limited by the atom cloud's free fall in the cavity. The isotropic cooling light's disordered properties provide a large and stable number of cold atoms, leading to a high signal-to-noise ratio limited by atomic shot noise. A relative frequency stability of 2.2x10{sup -13{tau}-1/2} has been achieved, averaged down to 4x10{sup -15} after 5x10{sup 3} s of integration. Development of such a high-performance compact clock is of major relevance for on-board applications, such as satellite-positioning systems. As a cesium clock, it opens the door to a new generation of compact primary standards and timekeeping devices.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗