Search NASA⌕ Search

SEARCH · Search NASA

Results for “SCATTERING FUNCTION”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,423 records · Page 79

Magnetic properties of the quasi-one-dimensional S = 1 spin chain antiferromagnet BaNi Te 2 O 7

We report a quasi-one-dimensional S=1 spin chain compound BaNiTe 2 O 7 . This magnetic system has been investigated by magnetic susceptibility, specific heat, and neutron powder diffraction. These results indicate that BaNiTe 2 O 7 develops a short-range magnetic correlation around T ~ 22K. With further cooling, an antiferromagnetic phase transition is observed at T N ~ 5.4K. Neutron powder diffraction revealed antiferromagnetic noncollinear order with a commensurate propagation vector k = (1/2,1,0). The refined magnetic moment size of Ni 2+ at 1.5 K is 1.84 μB , and its noncollinear spin texture is confirmed by first-principles calculations. In conclusion, inelastic neutron-scattering results and density functional theory calculations confirmed the quasi-one-dimensional nature of the spin systems.

1-dimensional spin chains↗

Structural changes in nano-crystalline mackinawite (FeS) at high - pressure.

The high-pressure behavior of nanocrystalline mackinawite (FeS) with particle sizes of 6, 7 and 8 nm has been investigated by high-energy X-ray total scattering and pair distribution function analysis. An irreversible first-order structural phase transition from tetragonal mackinawite to orthorhombic FeS-II was observed at about 3 GPa. The transition is induced by the closure of the van der Waals gap in the layered mackinawite structure. A grain size effect on the transition pressure and the compressibility was observed.

36 MATERIALS SCIENCE↗

Quantitative evaluation of statistical errors in small-angle X-ray scattering measurements

A new model is proposed for the measurement errors incurred in typical small-angle X-ray scattering (SAXS) experiments, which takes into account the setup geometry and physics of the measurement process. The model accurately captures the experimentally determined errors from a large range of synchrotron and in-house anode-based measurements. Its most general formulation gives for the variance of the buffer-subtracted SAXS intensity σ 2 ( q ) = [ I ( q ) + const.]/( kq ), where I ( q ) is the scattering intensity as a function of the momentum transfer q ; k and const. are fitting parameters that are characteristic of the experimental setup. The model gives a concrete procedure for calculating realistic measurement errors for simulated SAXS profiles. In addition, the results provide guidelines for optimizing SAXS measurements, which are in line with established procedures for SAXS experiments, and enable a quantitative evaluation of measurement errors.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

A numerical method for deriving shape functions of nanoparticles for pair distribution function refinements

We report that in the structural refinement of nanoparticles, discrete atomistic modeling can be used for small nanocrystals (< 15 nm), but becomes computationally unfeasible at larger sizes, where instead unit-cell-based small-box modeling is usually employed. However, the effect of the nanocrystal's shape is often ignored or accounted for with a spherical model regardless of the actual shape due to the complexities of solving and implementing accurate shape effects. Recent advancements have provided a way to determine the shape function directly from a pair distribution function calculated from a discrete atomistic model of any given shape, including both regular polyhedra (e.g. cubes, spheres, octahedra) and anisotropic shapes (e.g. rods, discs, ellipsoids) [Olds et al. (2015). J. Appl. Cryst. 48, 1651–1659], although this approach is still limited to small size regimes due to computational demands. In order to accurately account for the effects of nanoparticle size and shape in small-box refinements, a numerical or analytical description is needed. This article presents a methodology to derive numerical approximations of nanoparticle shape functions by fitting to a training set of known shape functions; the numerical approximations can then be employed on larger sizes yielding a more accurate and physically meaningful refined nanoparticle size. Lastly, the method is demonstrated on a series of simulated and real data sets, and a table of pre-calculated shape function expressions for a selection of common shapes is provided.

36 MATERIALS SCIENCE↗

Multiwavelength anomalous X-ray diffraction for combined imaging of atomic displacement and strain

The X-ray Bragg coherent diffractive imaging (CDI) technique assumes that the structure factor holds constant over the measured crystal. This approximation breaks down for materials exhibiting variations in the unit-cell configuration, such as piezo- and ferroelectrics. In that case, the strain field cannot be reliably determined from the reconstruction because the lattice deformation and the structure factor contribute concomitantly. Proposed here is a solution to this problem achieved by combining Bragg CDI and the multiwavelength anomalous diffraction approach that measures a Friedel pair of reflections at two different photon energies near an absorption edge. Comparing the obtained reconstructions with a parametric model that includes calculating the scattering amplitude as a function of wavelength and the unit-cell configuration, the contributions of the lattice deformation and the structure factor are separated. Simulations of the ferroelectric material BaTiO 3 demonstrate the possibility of simultaneous probing of the strain and displacement of the Ti atoms. The proposed method opens up an opportunity to apply coherent X-ray diffraction for nanoscale-resolved 3D mapping of polarization domains in micro- and nanocrystals.

lattice deformation↗

Structural Evolution in Hollandite Solid Solutions Across the A‐Site Compositional Range from Ba 1.33 Ga 2.66 Ti 5.34 O 16 to Cs 1.33 Ga 1.33 Ti 6.67 O 16

Hollandite solid solutions along the A‐site compositional range from the pure barium end‐member Ba 1.33 Ga 2.66 Ti 5.34 O 16 to the pure cesium end‐member Cs 1.33 Ga 1.33 Ti 6.67 O 16 have been synthesized using a solid‐state reaction technique. The crystal structure of the hollandite across the entire compositional range remained in the I 4 /m space group. Structural evolution was resolved by neutron diffraction, total scattering data, and density functional theory calculations. A trend of decreasing thermodynamic stability with smaller tunnel cations was attributed to increased structural distortion observed in the system. In addition, the tunnel cations' local environment was studied in the eightfold coordinated oxygen cavities. Local binding features of the tunnel cations reveals that the hollandite structure can strongly stabilize tunnel cations, even at elevated temperatures up to 500 K.

Xu, Yun↗

SU-E-T-554: Comparison of Electron Disequilibrium Factor in External Photon Beams for Different Models of Linear Accelerators

Purpose: The dose in the buildup region of a photon beam is usually determined by the transport of the primary secondary electrons and the contaminating electrons from accelerator head. This can be quantified by the electron disequilibrium factor, E, defined as the ratio between total dose and equilibrium dose (proportional to total kerma), E = 1 in regions beyond buildup region. Ecan be different among accelerators of different models and/or manufactures of the same machine. This study compares E in photon beams from different machine models/ Methods: Photon beam data such as fractional depth dose curve (FDD) and phantom scatter factors as a function of field size and phantom depth were measured for different Linac machines. E was extrapolated from these fractional depth dose data while taking into account inverse-square law. The ranges of secondary electron were chosen as 3 and 6 cm for 6 and 15 MV photon beams, respectively. The field sizes range from 2x2 to 40x40 cm{sup 2}. Results: The comparison indicates the standard deviations of electron contamination among different machines are about 2.4 - 3.3% at 5 mm depth for 6 MV and 1.2 - 3.9% at 1 cm depth for 15 MV for the same field size. The corresponding maximum deviations are 3.0 - 4.6% and 2 - 4% for 6 and 15 MV, respectively. Both standard and maximum deviations are independent of field sizes in the buildup region for 6 MV photons, and slightly decreasing with increasing field size at depths up to 1 cm for 15 MV photons. Conclusion: The deviations of electron disequilibrium factor for all studied Linacs are less than 3% beyond the depth of 0.5 cm for the photon beams for the full range of field sizes (2-40 cm) so long as they are from the same manufacturer.

07 ISOTOPE AND RADIATION SOURCES↗

WE-A-12A-01: Medical Physics 1.0 to 2.0, Session 2: Radiography, Mammography and Fluoroscopy

Medical Physics 2.0 is a bold vision for an existential transition of clinical imaging physics in face of the new realities of value-based and evidencebased medicine, comparative effectiveness, and meaningful use. It speaks to how clinical imaging physics can expand beyond traditional insular models of inspection and acceptance testing, oriented toward compliance, towards team-based models of operational engagement, prospective definition and assurance of effective use, and retrospective evaluation of clinical performance. Organized into four sessions of the AAPM, this particular session focuses on three specific modalities as outlined below. Radiography 2.0: The development of electronic capture in recent years has changed the landscape and spurred reinvestment by healthcare providers. The radiography presentation will explore how the diagnostic medical physicist must adapt to these changes to support radiographic imaging, and how she/he can add value in radiography practice over the next 5-10 years. Topics of discussion include new metrology of evaluation, new models of clinical engagement, and effective integration of new technologies. Mammography 2.0: Mammography has been an interesting testing ground on the effectiveness of close involvement of medical physicists with equipment in the past twenty years. The outcomes have clearly shown major improvements in image quality and significant reduction in the average glandular dose. However, the medical physicist's role in mammography has been largely focused to annual surveys and with limited input on operational issues with image artifacts, optimal mammographic acquisition mode and problems with image quality. This mammography presentation will address why and how medical physicists must be prepared to address the new models of practice that include new metrics of performance and the integration of new technologies (DBT, syncretized mammograms, contrast mammography, breast CT) into clinical practice. Fluoroscopy 2.0: Physics support of fluoroscopy should be operationally as opposed to compliance focused. Testing protocols must address new hardware, acquisition methods, and image processing. Future available tools are discussed. Proper configuration of acquisition parameters (focal spot size, voltage and added filter, tube current, pulse width, pulse rate, scatter removal) as a function of patient size from the neonate to bariatric patient is key to providing diagnostic image quality at properly managed radiation doses. Learning Objectives: Appreciate the limitations of the currently available tools and techniques in clinical medical physics in radiography, mammography, and fluoroscopy, and ways to improve upon current deficiencies. Appreciate the changing environment of imaging practice and the need for the medical physicist to be an expert consultant and educator in a capacity that extends beyond the annual survey of equipment. Understand the status of the rapidly changing environment in breast imaging from planar imaging to tomosynthesis and possibly to breast CT. Identify appropriate configuration of acquisition parameters as a function of patient size to manage radiation dose and ensure diagnostic image quality.

60 APPLIED LIFE SCIENCES↗

TH-AB-209-12: Tissue Equivalent Phantom with Excised Human Tissue for Assessing Clinical Capabilities of Coherent Scatter Imaging Applications

Purpose: Previously we reported the development of anthropomorphic tissue-equivalent scatter phantoms of the human breast. Here we present the first results from the scatter imaging of the tissue equivalent breast phantoms for breast cancer diagnosis. Methods: A breast phantom was designed to assess the capability of coded aperture coherent x-ray scatter imaging to classify different types of breast tissue (adipose, fibroglandular, tumor). The phantom geometry was obtained from a prone breast geometry scanned on a dedicated breast CT system. The phantom was 3D printed using the segmented DICOM breast CT data. The 3D breast phantom was filled with lard (as a surrogate for adipose tissue) and scanned in different geometries alongside excised human breast tissues (obtained from lumpectomy and mastectomy procedures). The raw data were reconstructed using a model-based reconstruction algorithm and yielded the location and form factor (i.e., momentum transfer (q) spectrum) of the materials that were imaged. The measured material form factors were then compared to the ground truth measurements acquired by x-ray diffraction (XRD) imaging. Results: Our scatter imaging system was able to define the location and composition of the various materials and tissues within the phantom. Cancerous breast tissue was detected and classified through automated spectral matching and an 86% correlation threshold. The total scan time for the sample was approximately 10 minutes and approaches workflow times for clinical use in intra-operative or other diagnostic tasks. Conclusion: This work demonstrates the first results from an anthropomorphic tissue equivalent scatter phantom to characterize a coherent scatter imaging system. The functionality of the system shows promise in applications such as intra-operative margin detection or virtual biopsy in the diagnosis of breast cancer. Future work includes using additional patient-derived tissues (e.g., human fat), and modeling additional organs (e.g., lung).

60 APPLIED LIFE SCIENCES↗

Second-Order Stationary Solutions for Fermions in an External Coulomb Field

We have studied self-conjugate second-order equations with spinor wavefunctions for fermions moving in an external Coulomb field. For stationary states, the equations are characterized by separated states with positive and negative energies, which render probabilistic interpretation possible. For the Coulomb field of attraction, the energy spectrum of the second-order equation coincides with the spectrum of the Dirac equation, while the probability densities of states are slightly different. For a Coulomb field of repulsion, there exists an impermeable potential barrier with radius depending on the classical electron radius and on the electron energy. The existence of the impermeable barrier does not contradict the results of experiment for determining the inner electron structure and does not affect (in the lowest order of perturbation theory) the Coulomb electron scattering cross section. The existence of the impermeable barrier can lead to positron confinement in supercritical nuclei with Z ≥ 170 in case of realization of spontaneous emission of vacuum electron–positron pairs.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Thermoelectric properties of symmetric and asymmetric double quantum well structures

The electronic states and carrier transport in (100)PbTe/Pb {sub 1-x} Eu{sub x} Te double quantum wells are theoretically analyzed. The dependences of the mobility and Seebeck coefficient on the thickness of the internal barrier in symmetric and asymmetric structures are investigated. It was found that at great distance between the wells even small violation of the structure symmetry and essential reconstruction of electron wave functions results in suppression of intersubband scattering with carriers transfer between the wells and provides the correct limit to isolated quantum well in kinetic coefficients. Some possibilities of increasing the thermoelectric power factor are found, and a suitable set of structure parameters is calculated within the proposed model.

36 MATERIALS SCIENCE↗

Asymptotically Compatible Reproducing Kernel Collocation and Meshfree Integration for Nonlocal Diffusion

Reproducing kernel (RK) approximations are meshfree methods that construct shape functions from sets of scattered data. We present an asymptotically compatible (AC) RK collocation method for nonlocal diffusion models with Dirichlet boundary condition. The numerical scheme is shown to be convergent to both nonlocal diffusion and its corresponding local limit as nonlocal interaction vanishes. The analysis is carried out on a special family of rectilinear Cartesian grids for a linear RK method with designed kernel support. The key idea for the stability of the RK collocation scheme is to compare the collocation scheme with the standard Galerkin scheme, which is stable. In addition, assembling the stiffness matrix of the nonlocal problem requires costly computational resources because high-order Gaussian quadrature is necessary to evaluate the integral. We thus provide a remedy to the problem by introducing a quasi-discrete nonlocal diffusion operator for which no numerical quadrature is further needed after applying the RK collocation scheme. The quasi-discrete nonlocal diffusion operator combined with RK collocation is shown to be convergent to the correct local diffusion problem by taking the limits of nonlocal interaction and spatial resolution simultaneously. The theoretical results are then validated with numerical experiments. We additionally illustrate a connection between the proposed technique and an existing optimization based approach based on generalized moving least squares.

97 MATHEMATICS AND COMPUTING↗

Measurement of the energy asymmetry in $t\bar{t} j$ production at 13 TeV with the ATLAS experiment and interpretation in the SMEFT framework

A measurement of the energy asymmetry in jet-associated top-quark pair production is presented using 139fb -1 of data collected by the ATLAS detector at the Large Hadron Collider during pp collisions at $\sqrt{s}$ =13TeV. The observable measures the different probability of top and antitop quarks to have the higher energy as a function of the jet scattering angle with respect to the beam axis. The energy asymmetry is measured in the semileptonic $t\bar{t}$ decay channel, and the hadronically decaying top quark must have transverse momentum above 350GeV. The results are corrected for detector effects to particle level in three bins of the scattering angle of the associated jet. The measurement agrees with the SM prediction at next-to-leading-order accuracy in quantum chromodynamics in all three bins. In the bin with the largest expected asymmetry, where the jet is emitted perpendicular to the beam, the energy asymmetry is measured to be -0.043 ± 0.020, in agreement with the SM prediction of -0.037 ± 0.003. Interpreting this result in the framework of the Standard Model effective field theory (SMEFT), it is shown that the energy asymmetry is sensitive to the top-quark chirality in four-quark operators and is therefore a valuable new observable in global SMEFT fits.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Measurement of the neutron magnetic form factor at high Q-2 using the ratio method on deuterium

The 12-GeV Upgrade at Jefferson Lab will create an opportunity to dramatically extend our knowledge of the magnetic form factor of the neutron G^n_M and the other elastic, electromagnetic form factors. We describe here an approved experiment that will cover a Q2 range (3.5 – 14 GeV2) with significant discovery potential. Different theoretical approaches (generalized parton distributions, Dyson-Schwinger equations, etc) diverge is this region and existing data cannot distinguish among them. The proposed measurement will be performed in Hall B with the CLAS12 detector and will have statistical and systematic uncertainties below 3%. It is based on the ratio of electron-neutron to electron-proton scattering that was successfully applied in the CLAS detector at Jefferson Lab.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Local System Support for PDB Biological Unit Search and Display (Final Progress Report)

The BIOMOL grant was for 'Local System Support for PDB Biological Unit Search and Display' to augment Rasmol's [Bernstein 2000] [Sayle, Milner-White 1995] existing macromolecular display functions with new capabilities by taking advantage of recent increases in local computing power in order to move functionality that is now scattered among various local and remote systems into one local package. Work included new algorithms for molecular surface display, an extended format for Protein Data Bank Entries, work on issues relating to the integration of multiple diffraction images formats.

59 BASIC BIOLOGICAL SCIENCES↗

The EMC Effect in A=3 Nuclei

The European Muon Collaboration (EMC) discovered an unexpected and puzzling result in 1983 when comparing the deep inelastic scattering(DIS) nuclear structure functions of Deuterium and Iron. The per-nucleon structure functions were found to be different for the two nuclei, rather than a simple average over the proton and neutron structure functions. In subsequent experiments, this phenomenon was confirmed for additional nuclei, with the magnitude approximately scaling with the density. The exact mechanism leading to this in- medium structure function modification has not been identified. I will discuss recent results from JLab exploring the EMC effect by using an electron beam to probe two mirror nuclei, Helium-3 and Tritium. iv

Bane, Jason↗

High-Performance Integrated Window and Façade Solutions for California

The researchers developed a new generation of high-performance façade systems and supporting design and management tools to support industry in meeting California’s greenhouse gas reduction targets, reduce energy consumption, and enable an adaptable response to minimize real-time demands on the electricity grid. The project resulted in five outcomes: (1) The research team developed an R-5, 1-inch thick, triplepane, insulating glass unit with a novel low-conductance aluminum frame. This technology can help significantly reduce residential cooling and heating loads, particularly during the evening. (2) The team developed a prototype of a windowintegrated local ventilation and energy recovery device that provides clean, dry fresh air through the façade with minimal energy requirements. (3) A daylight-redirecting louver system was prototyped to redirect sunlight 15–40 feet from the window. Simulations estimated that lighting energy use could be reduced by 35–54 percent without glare. (4) A control system incorporating physics-based equations and a mathematical solver was prototyped and field tested to demonstrate feasibility. Simulations estimated that total electricity costs could be reduced by 9-28 percent on sunny summer days through adaptive control of operable shading and daylighting components and the thermostat compared to state-of-the-art automatic façade controls in commercial building perimeter zones. (5) Supporting models and tools needed by industry for technology R&D and market transformation activities were validated. Attaining California’s clean energy goals require making a fundamental shift from today’s ad-hoc assemblages of static components to turnkey, intelligent, responsive, integrated building façade systems. These systems offered significant reductions in energy use, peak demand, and operating cost in California.

24 POWER TRANSMISSION AND DISTRIBUTION↗