Search NASA⌕ Search

SEARCH · Search NASA

Results for “Samples”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,423 records · Page 79

Per- and Polyfluoroalkyl Substances Confirmatory Sampling Report, South Repeater Building (SWMU 121), Kennedy Space Center, Florida

This Per- and Polyfluoroalkyl Substances (PFAS) Confirmatory Sampling (CS) Report was prepared by AECOM Technical Services, Inc. (AECOM) for the National Aeronautics and Space Administration (NASA) under Contract 80KSC019D0010, Task Order 80KSC021F0096. The purpose of this report is to document CS activities at the South Repeater Building, Solid Waste Management Unit (SWMU) 121, formerly known as the Area 3 Repeater Building (A3RB). A Phase I SWMU Assessment and Confirmatory Sampling Report (NASA 2019) and a Phase II and III SWMU Assessment and Confirmatory Sampling Report (NASA 2022b) were previously submitted detailing Center-Wide assessment activities performed at the John F. Kennedy Space Center (KSC) in Florida that identified 33 locations of concern and 19 areas of potential concern at KSC associated with the storage, use, or release of materials containing PFAS. A review of the analytical results from investigation derived waste samples collected in 2020 from the South Repeater Building area indicated concentrations of perfluorooctanesulfonic acid (PFOS) were above Florida Department of Environmental Protection (FDEP) provisional Groundwater Cleanup Target Levels of 70 nanograms per liter (ng/L) at a concentration of 1,750 ng/L. Following this review, the KSC Fire Chief was contacted; the Chief recalled fighting a brush fire in 1998 in the area, during which an unknown volume of aqueous film-forming foam was used to extinguish the fire. The Phase II and Phase III SWMU Assessment Report recommended this area proceed to CS. Historical results in this area are provided in Appendix A . PFAS CS activities were contracted at the South Repeater Building. Initial CS activities were conducted in accordance with the PFAS Assessment and Mitigation Work Plan (AECOM 2022), which was submitted to the NASA Remediation Project Management team and accepted by the team on November 1 and 8, 2021. The objectives of the PFAS CS were to: - - Confirm and begin to assess the extent of PFAS affected media in the South Repeater Building area. - - Identify locations for groundwater, soil, surface water, and soil core sampling. - - Qualitatively characterize the migration potential of released PFAS to environmental media (soil, groundwater, and surface water). The following activities were completed to meet the PFAS CS objectives: - - Installation of monitoring wells via direct push technology (DPT) and rotosonic techniques - - Groundwater, soil, and surface water sampling - - Collection of soil cores to evaluate site lithology - - Development of initial PFAS plume characterization

PFAS↗

Molecular Inventory and Comparative Organic Profiling of A Homogenized Aggregate Sample From Asteroid (101955) Bennu

Evaluating the distribution and diversity of solvent-soluble organic molecules in extraterrestrial materials provide information about the physicochemical environments where prebiotic chemistry occurred and is essential for assessing the inventory of prebiotic compounds available to the early Earth. In this work, we conducted a comprehensive molecular characterization of solvent-soluble organic compounds in a homogenized aggregate sample (ID: OREX-800107-128) of unsorted regolith from asteroid (101955) Bennu returned by NASA’s OSIRIS-REx mission. Using two-dimensional gas chromatography coupled with high-resolution time-of-flight mass spectrometry (GC×GC-HRMS), we identified 87 organic compounds across several molecular classes, including alkanes, polycyclic aromatic hydrocarbons, and nitrogen-, oxygen-, and sulfur-bearing species. Comparison with the organic inventory of CI (Orgueil), C2-ungrouped (Tagish Lake and Tarda), and CM2 (Murchison) carbonaceous chondrites revealed that Bennu sample OREX-800107-128 is most similar to Tagish Lake and Tarda yet compositionally distinct from all of these meteorites. This Bennu sample exhibits a relatively high abundance of low-molecular-weight aromatics (e.g., toluene), pyridine derivatives, and sulfur species such as dimethyl sulfite, consistent with episodic low-temperature aqueous alteration. The presence of these organic compounds suggests that this material experienced chemically diverse processes in the parent body conducive to complex organic synthesis, including aldol condensation reactions responsible for N- and O-bearing compounds. We also compared the molecular distributions of this Bennu sample and previously analyzed samples from (162173) Ryugu to assess potential common origins between these two carbonaceous asteroids. Bennu shows more chemically diverse and nitrogen-rich organic materials than Ryugu. While both asteroids share broadly similar primitive compositions, the observed chemical differences indicate distinct evolutionary histories within a likely common formation environment though whether Bennu and Ryugu derive from a single compositionally heterogeneous parent body or from multiple closely related progenitors remains unresolved. Further detailed comparative analyses of material from Bennu, Ryugu, and specific carbonaceous meteorites (e.g., Tagish Lake and Tarda) will provide new insights into how the N-rich molecular profile observed in Bennu samples was formed and evolved in the outer Solar System.

sample return↗

ENVIRONMENTAL SAMPLING USING LOCATION SPECIFIC AIR MONITORING IN BULK HANDLING FACILITIES

Since the introduction of safeguards strengthening measures approved by the International Atomic Energy Agency (IAEA) Board of Governors (1992-1997), international nuclear safeguards inspectors have been able to utilize environmental sampling (ES) (e.g. deposited particulates, air, water, vegetation, sediments, soil and biota) in their safeguarding approaches at bulk uranium/plutonium handling facilities. Enhancements of environmental sampling techniques used by the IAEA in drawing conclusions concerning the absence of undeclared nuclear materials or activities will soon be able to take advantage of a recent step change improvement in the gathering and analysis of air samples at these facilities. Location specific air monitoring feasibility tests have been performed with excellent results in determining attribute and isotopic composition of chemical elements present in an actual test-bed sample. Isotopic analysis of collected particles from an Aerosol Contaminant Extractor (ACE) collection, was performed with the standard bulk sampling protocol used throughout the IAEA network of analytical laboratories (NWAL). The results yielded bulk isotopic values expected for the operations. Advanced designs of air monitoring instruments such as the ACE may be used in gas centrifuge enrichment plants (GCEP) to detect the production of highly enriched uranium (HEU) or enrichments not declared by a State. Researchers at Savannah River National Laboratory in collaboration with Oak Ridge National Laboratory are developing the next generation of ES equipment for air grab and constant samples that could become an important addition to the international nuclear safeguards inspector's toolkit. Location specific air monitoring to be used to establish a baseline environmental signature of a particular facility employed for comparison of consistencies in declared operations will be described in this paper. Implementation of air monitoring will be contrasted against the use of smear ES when used during unannounced inspections, design information verification, limited frequency unannounced access, and complementary access visits at bulk handling facilities. Analysis of technical features required for tamper indication and resistance will demonstrate the viability of successful application of the system in taking ES within a bulk handling location. Further exploration of putting this technology into practice is planned to include mapping uranium enrichment facilities for the identification of optimal for installation of air monitoring devices.

38 RADIATION CHEMISTRY, RADIOCHEMISTRY, AND NUCLEA↗

On sampling fractions and electron shower shapes

We study the usage of various definitions of sampling fractions in understanding electron shower shapes in a sampling multilayer electromagnetic calorimeter. We show that the sampling fractions obtained by the conventional definition (I) of (average observed energy in layer)/(average deposited energy in layer) will not give the best energy resolution for the calorimeter. The reason for this is shown to be the presence of layer by layer correlations in an electromagnetic shower. The best resolution is obtained by minimizing the deviation from the total input energy using a least squares algorithm. The 'sampling fractions' obtained by this method (II) are shown to give the best resolution for overall energy. We further show that the method (II) sampling fractions are obtained by summing the columns of a non-local {lambda} tensor that incorporates the correlations. We establish that the sampling fractions (II) cannot be used to predict the layer by layer energies and that one needs to employ the full {lambda} tensor for this purpose. This effect is again a result of the correlations.

43 PARTICLE ACCELERATORS↗

Sampling and analysis of cyber media to determine whether it meets the definition of a hazardous waste - 15208

Sandia National Laboratories, New Mexico (SNL/NM) was tasked to support The Department of Energy (DOE) in the disposal of classified cyber media. Certain cyber media have lead and silver. Various cyber media types were identified because they may have a hazardous waste characteristic. The overall objective of this sampling effort is to obtain representative samples of specific types of cyber media and analyze those samples to collect data to determine definitively if the cyber media are hazardous waste. Ten different samples were obtained from the unclassified waste stream and shredded to meet the sampling criteria. The samples were shipped to an offsite analytical laboratory with a Chain of Custody. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Resonant ultrasound spectroscopy for materials with high damping and samples of arbitrary geometry

This paper describes resonant ultrasound spectroscopy (RUS) as a powerful and established technique for measuring elastic constants of a material with general anisotropy. The first step of this technique consists of extracting resonance frequencies and damping from the vibrational frequency spectrum measured on a sample with free boundary conditions. An inversion technique is then used to retrieve the elastic tensor from the measured resonance frequencies. As originally developed, RUS has been mostly applicable to (i) materials with small damping such that the resonances of the sample are well separated and (ii) samples with simple geometries for which analytical solutions exist. In this paper, these limitations are addressed with a new RUS approach adapted to materials with high damping and samples of arbitrary geometry. Resonances are extracted by fitting a sum of exponentially damped sinusoids to the measured frequency spectrum. The inversion of the elastic tensor is achieved with a genetic algorithm, which allows searching for a global minimum within a discrete and relatively wide solution space. First, the accuracy of the proposed approach is evaluated against numerical data simulated for samples with isotropic symmetry and transversely isotropic symmetry. Subsequently, the applicability of the approach is demonstrated using experimental data collected on a composite structure consisting of a cylindrical sample of Berea sandstone glued to a large piezoelectric disk. In the proposed experiments, RUS is further enhanced by the use of a 3-D laser vibrometer allowing the visualization of most of the modes in the frequency band studied.

36 MATERIALS SCIENCE↗

Profiling of adrenocorticotropic hormone and arginine vasopressin in human pituitary gland and tumor thin tissue sections using droplet-based liquid-microjunction surface-sampling-HPLC–ESI-MS–MS

Described here are the results from the profiling of the proteins arginine vasopressin (AVP) and adrenocorticotropic hormone (ACTH) from normal human pituitary gland and pituitary adenoma tissue sections using a fully automated droplet-based liquid microjunction surface sampling-HPLC-ESI-MS/MS system for spatially resolved sampling, HPLC separation, and mass spectral detection. Excellent correlation was found between the protein distribution data obtained with this droplet-based liquid microjunction surface sampling-HPLC-ESI-MS/MS system and those data obtained with matrix assisted laser desorption ionization (MALDI) chemical imaging analyses of serial sections of the same tissue. The protein distributions correlated with the visible anatomic pattern of the pituitary gland. AVP was most abundant in the posterior pituitary gland region (neurohypophysis) and ATCH was dominant in the anterior pituitary gland region (adenohypophysis). The relative amounts of AVP and ACTH sampled from a series of ACTH secreting and non-secreting pituitary adenomas correlated with histopathological evaluation. ACTH was readily detected at significantly higher levels in regions of ACTH secreting adenomas and in normal anterior adenohypophysis compared to non-secreting adenoma and neurohypophysis. AVP was mostly detected in normal neurohypophysis as anticipated. This work demonstrates that a fully automated droplet-based liquid microjunction surface sampling system coupled to HPLC-ESI-MS/MS can be readily used for spatially resolved sampling, separation, detection, and semi-quantitation of physiologically-relevant peptide and protein hormones, such as AVP and ACTH, directly from human tissue. In addition, the relative simplicity, rapidity and specificity of the current methodology support the potential of this basic technology with further advancement for assisting surgical decision-making.

59 BASIC BIOLOGICAL SCIENCES↗

IR Thermographic Analysis of 3D Printed CFRP Reference Samples with Back-Drilled and Embedded Defects

Carbon-fiber composite structures may demonstrate a defective behavior due to manufacturing induced anomalies (delamination, dis-bonds) or service related defectives (impact damage, water ingress). Thus, there is a need for a relatively fast and low cost non-intrusive testing schemes such as infrared thermography (IRT). Still, thermography testing requires calibrated samples and coupons to yield best results. The presented research demonstrates the novel use of 3D printing technology to generate IRT calibration samples. In this text, two carbon fiber reinforced polymer samples are 3D printed; the first mimics a 'back-drilled holes' type coupons, while the other is designed to embed air pockets similar to Teflon inserts. The generated samples are then tested using two IRT modalities; namely pulse thermography and lock-in thermography. Furthermore, the resulted thermograms are processed using a principle component analysis, to help highlight the variance of defectives in a consistent manner among the samples. This research findings offer insights on the variation of detectability between embedded and back-printed samples, which might be due to the inserts thickness.

36 MATERIALS SCIENCE↗

Rapid determination of 210 Po in water samples

A new rapid method for the determination of 210 Po in water samples has been developed at the Savannah River National Laboratory (SRNL) that can be used for emergency response or routine water analyses. If a radiological dispersive device (RDD) event or a radiological attack associated with drinking water supplies occurs, there will be an urgent need for rapid analyses of water samples, including drinking water, ground water and other water effluents. Current analytical methods for the assay of 210 Po in water samples have typically involved spontaneous auto-deposition of 210 Po onto silver or other metal disks followed by counting by alpha spectrometry. The auto-deposition times range from 90 minutes to 24 hours or more, at times with yields that may be less than desirable. If sample interferences are present, decreased yields and degraded alpha spectrums can occur due to unpredictable thickening in the deposited layer. Separation methods have focused on the use of Sr Resin, often in combination with 210 Pb analysis. A new rapid method for 210 Po in water samples has been developed at the Savannah River National Laboratory (SRNL) that utilizes a rapid calcium phosphate co-precipitation method, separation using DGA Resin (N,N,N,N-tetraoctyldiglycolamide extractant-coated resin, Eichrom Technologies or Triskem-International), followed by rapid microprecipitation of 210 Po using bismuth phosphate for counting by alpha spectrometry. This new method can be performed quickly with excellent removal of interferences, high chemical yields and very good alpha peak resolution, eliminating any potential problems with the alpha source preparation for emergency or routine samples. A rapid sequential separation method to separate 210 Po and actinide isotopes was also developed. This new approach, rapid separation with DGA Resin plus microprecipitation for alpha source preparation, is a significant advance in radiochemistry for the rapid determination of 210 Po.

38 RADIATION CHEMISTRY, RADIOCHEMISTRY, AND NUCLEA↗

Rapid determination of actinides in asphalt samples

A new rapid method for the determination of actinides in asphalt samples has been developed that can be used in emergency response situations or for routine analysis If a radiological dispersive device (RDD), Improvised Nuclear Device (IND) or a nuclear accident such as the accident at the Fukushima Nuclear Power Plant in March, 2011 occurs, there will be an urgent need for rapid analyses of many different environmental matrices, including asphalt materials, to support dose mitigation and environmental clean up. The new method for the determination of actinides in asphalt utilizes a rapid furnace step to destroy bitumen and organics present in the asphalt and sodium hydroxide fusion to digest the remaining sample. Sample preconcentration steps are used to collect the actinides and a new stacked TRU Resin + DGA Resin column method is employed to separate the actinide isotopes in the asphalt samples. The TRU Resin plus DGA Resin separation approach, which allows sequential separation of plutonium, uranium, americium and curium isotopes in asphalt samples, can be applied to soil samples as well.

38 RADIATION CHEMISTRY, RADIOCHEMISTRY, AND NUCLEA↗

Rapid determination of actinides in seawater samples

A new rapid method for the determination of actinides in seawater samples has been developed at the Savannah River National Laboratory. The actinides can be measured by alpha spectrometry or inductively-coupled plasma mass spectrometry. The new method employs novel pre-concentration steps to collect the actinide isotopes quickly from 80 L or more of seawater. Actinides are co-precipitated using an iron hydroxide co-precipitation step enhanced with Ti +3 reductant, followed by lanthanum fluoride co-precipitation. Stacked TEVA Resin and TRU Resin cartridges are used to rapidly separate Pu, U, and Np isotopes from seawater samples. TEVA Resin and DGA Resin were used to separate and measure Pu, Am and Cm isotopes in seawater volumes up to 80 L. This robust method is ideal for emergency seawater samples following a radiological incident. It can also be used, however, for the routine analysis of seawater samples for oceanographic studies to enhance efficiency and productivity. In contrast, many current methods to determine actinides in seawater can take 1–2 weeks and provide chemical yields of ~30–60 %. This new sample preparation method can be performed in 4–8 h with tracer yields of ~85–95 %. By employing a rapid, robust sample preparation method with high chemical yields, less seawater is needed to achieve lower or comparable detection limits for actinide isotopes with less time and effort.

61 RADIATION PROTECTION AND DOSIMETRY↗

Rapid method to determine 226Ra in steel samples

The rapid measurement of 226 Ra in steel samples is very important in the event of a radiological emergency. 226 Ra (T 1/2 = 1600 y) is a natural radionuclide present in the environment and a highly toxic alpha-emitter. Due to its long life and tendency to concentrate in bones, 226 Ra ingestion or inhalation can lead to significant committed dose to individuals. A new method for the determination of 226 Ra in steel samples has been developed at the Savannah River Environmental Laboratory. The new method employs a rugged acid digestion method that includes hydrofluoric acid, followed by a single precipitation step to rapidly preconcentrate the radium and remove most of the dissolved steel sample matrix. Radium is then separated using a combination of cation exchange and extraction chromatography, and 226 Ra is measured by alpha spectrometry. This approach has a sample preparation time of ~ 8 h for steel samples, has a very high tracer yield (> 88%), and removes interferences effectively. A 133 Ba yield tracer is used so that samples can be counted immediately following the separation method, avoiding lengthy ingrowth times that are required in other methods.

38 RADIATION CHEMISTRY, RADIOCHEMISTRY, AND NUCLEA↗

The distinct conditions of atmospheric and underground nuclear tests revealed by Zn isotopic compositions of nuclear debris samples

We analyzed the Zn isotopic compositions of nuclear debris samples from atmospheric and underground nuclear tests. Samples from the site of atmospheric tests exhibit a range of Zn isotopic fractionation (δ 66 Zn JMC-Lyon = 0.23–0.86 ‰) while samples from underground tests exhibit Zn isotopic compositions with minimal variation among samples and from terrestrial igneous rock standards (δ 66 ZnJMC-Lyon = 0.28–0.39 ‰). In conclusion, the larger range of δ 66 Zn JMC-Lyon observed in atmospheric test samples relative to underground test samples is likely the result of the open system characteristics of atmospheric nuclear tests and the closed system characteristics of underground nuclear tests.

38 RADIATION CHEMISTRY, RADIOCHEMISTRY, AND NUCLEA↗

Design and Evaluation of an Experimental Technique for Mechanical and Fatigue Testing of Sub-Sized Samples

Some recently developed processing techniques allow fabrication of small specimens. The fatigue behavior of these small samples cannot be characterised according to the existing standards due to size limitations. The main objective of the present work is to develop an original technique for both mechanical and fatigue testing of sub-sized specimens produced by a high pressure torsion (HPT) method. The fatigue behavior of the sub-sized Ti-6Al-4 V samples, made from HPT-processed disks, is compared with that of the standard samples prepared according to the ASTM standards. Finite element method (FEM) analysis of the stress distribution under applied static load, for both sub-sized specimens and grips designed for their testing, is performed. Good agreement between the outcomes of tensile testing of the standard ASTM samples and sub-sized samples is observed. Fatigue data, represented by Wöhler curves for both types of samples, showed significant divergence of high cycle fatigue properties caused by incompliance of specimen geometries and surface/defect size ratio. The obtained results can be used to scale up the fatigue behavior from sub-sized specimens to the standard ones, as well as to predict the fatigue behavior of the bulk nanostructured metals and alloys produced by HPT.

77 NANOSCIENCE AND NANOTECHNOLOGY↗

Reduced alkali-silica reaction damage in recycled glass mortar samples with supplementary cementitious materials

Recycling waste glass aggregate into concrete can reduce environmental impacts but also may lead to serious alkali silica reaction (ASR) damage. This study aims to characterize ASR damage development in the mortar samples containing reactive glass aggregates and investigate the damage reduction effect of the waste supplementary cementitious materials (SCMs), including recycled glass powders and fly ash. The recycled glass aggregate mortar samples with/without SCMs were prepared in this study. The length change tests were first conducted with the prepared mortar samples based on the ASTM C1260 standard. The results demonstrated the added SCMs can largely decrease early-age ASR expansion rate. The optical microscope and Scanning Electron Microscope (SEM) with Energy Dispersive X-ray Spectroscopy (EDS) were further conducted to characterize the ASR damage in mortar samples and investigate the damage mitigation mechanism with added SCMs. The combined SEM imaging and chemical analysis indicated added SCMs can decrease both the alkali and calcium content of the generated ASR gel. In addition, the ASR damage development inside mortar samples were monitored with dynamic micron X-ray CT (μCT) over a reaction period of 63 hour at the temperature of 80°C. The scanning patterns demonstrated the ASR damage can be easily developed from the area with initial cracks and sharp corners. In conclusion, the images of glass power and fly ash samples showed significantly reduced ASR damage. This study showed that adding of SCMs can largely reduce ASR deterioration and thus facilitate the recycling glass particles into concrete.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Efficient Bayesian inference with latent Hamiltonian neural networks in No-U-Turn Sampling

When sampling for Bayesian inference, one popular approach in the computational field is to use Hamiltonian Monte Carlo (HMC) and specifically the No-U-Turn Sampler (NUTS), which automatically decides the end time of the Hamiltonian trajectory. However, HMC and NUTS can require numerous numerical gradients of the target density and can prove slow in practice when relying on computationally expensive forward models. We propose Latent Hamiltonian neural networks (L-HNNs) with HMC and NUTS for solving Bayesian inference problems. Once trained, L-HNNs do not require numerical gradients of the target density during sampling, and hence numerous evaluations of the forward computational model. Moreover, L-HNNs satisfy important properties such as perfect time reversibility and Hamiltonian conservation, making them well-suited for use within HMC and NUTS because stationarity can be shown. We also propose the integration of L-HNNs in an online error monitoring scheme, in which numerical gradients of the target density are used for a few samples whenever the L-HNNs prediction errors are large. This online error monitor scheme prevents sample degeneracy in regions of low probability density and ensures robust uncertainty quantification. We demonstrate L-HNNs in NUTS with online error monitoring on several analytical examples involving complex, heavy-tailed, and high-local-curvature probability densities. We then demonstrate the applicability of L-HNNs in NUTS to two computational case studies, namely the Allen-Cahn stochastic partial differential equation and an elliptic partial differential equation with 25 and 50 inference parameters, respectively. Overall, the L-HNNs in NUTS with online error monitoring satisfactorily inferred these probability densities. In conclusion, compared to traditional NUTS, L-HNNs in NUTS with online error monitoring required 1–2 orders of magnitude fewer numerical gradients of the target density and improved the effective sample size (ESS) per gradient (which is a measure of both the sampling quality and the computational expense) by an order of magnitude.

97 MATHEMATICS AND COMPUTING↗

An organogel library for solution NMR analysis of nanoparticle suspensions in non-aqueous samples

Surface contrast solution NMR methods (scNMR) are emerging as powerful tools to investigate the adsorption of small molecule ligands to the surface of nanoparticles (NP), returning fundamental insight into the kinetics and thermodynamics of sorption, as well as structural information on the adsorbed species. A prerequisite for the acquisition of high quality solution NMR data is the preparation of homogeneous and stable samples that return consistent NMR spectra and allow extensive signal averaging. Unfortunately, this condition does not apply to NMR samples containing NPs that often show a tendency to sediment and accumulate at the bottom of the NMR tube over the course of the experiment. We have recently shown that preparing NMR samples in an agarose gel matrix inhibits sedimentation and allows the characterization of small molecule-NP interactions by scNMR. Unfortunately, as the agarose gel only forms in aqueous solution, this sample preparation method cannot be used to stabilize NP suspensions in a non-aqueous environment. In this work, we introduce a library of 48 organogels, based on low molecular-mass organic gelators (LMOGs), to prepare NMR samples of small molecule/NP systems in a wide range of organic solvents. In addition, we present a simple method that takes advantage of 1H transverse relaxation (1H-R2) measurements to screen the library and identify the best gelator to characterize the small molecule-NP interaction of interest in the solvent of choice. We expect the results of this study will enable the preparation of homogeneous and stable samples of NPs in non-aqueous environments, therefore dramatically increasing the applicability of scNMR to the characterization of heterogeneous interactions and to the investigation of the role played by solvent molecules in regulating the kinetics and thermodynamics of sorption.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Comparative SEM and TEM analyses of apatite phases prepared by a multi-sample loading device

Highlights: • A multi-sample loading device which ultrasonically disperses samples was developed. • Comparative EM analyses on various apatite phases were efficiently carried out. • SEM-EDS data revealed distinctive values of O/P and Ca/P intensity ratios. • TEM-SAED data presented characteristic structural features of apatite phases. • Lattice parameters of bone and fossil apatite were affected by CO{sub 3} content. - Abstract: Comparative chemical and structural characterization of various apatite phases from both synthetic and natural sources were carried out by utilizing a multi-sample loading device developed for scanning electron microscopy (SEM) and transmission electron microscopy (TEM) analyses. The device is capable of spraying nanoparticles via ultrasonication, and four separate samples were loaded on a single TEM grid by a masking tool to characterize different apatite phases in consistent instrumental and analytical conditions. SEM energy dispersive spectroscopy (EDS) analysis of the apatite samples revealed distinctive values of O/P and Ca/P intensity ratios except for the fossil apatite due to its high proportion of externally originating phases. Selected area electron diffraction (SAED) pattern analysis presented the characteristic lattice parameters of the apatite phases, especially the bone and fossil apatite which had CO{sub 3}in their chemistry. Analyzing distinctive chemical and structural features among varied apatite phases can be efficiently carried out through electron microscopy with multiple samples on a single TEM grid, and such methods can be employed for characterizing a wider range of materials.

36 MATERIALS SCIENCE↗