Search NASA⌕ Search

SEARCH · Search NASA

Results for “Scanning techniques”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,423 records · Page 79

Spectral Analysis and Experimental Modeling of Ice Accretion Roughness

A self-consistent scheme for relating wind tunnel ice accretion roughness to the resulting enhancement of heat transfer is described. First, a spectral technique of quantitative analysis of early ice roughness images is reviewed. The image processing scheme uses a spectral estimation technique (SET) which extracts physically descriptive parameters by comparing scan lines from the experimentally-obtained accretion images to a prescribed test function. Analysis using this technique for both streamwise and spanwise directions of data from the NASA Lewis Icing Research Tunnel (IRT) are presented. An experimental technique is then presented for constructing physical roughness models suitable for wind tunnel testing that match the SET parameters extracted from the IRT images. The icing castings and modeled roughness are tested for enhancement of boundary layer heat transfer using infrared techniques in a "dry" wind tunnel.

Orr, D. J.↗

Materials Applications of Photoelectron Emission Microscopy

Photoelectron emission microscopy (PEEM) is a versatile technique that can image a variety of materials including metals, semiconductors and even insulators. Under favorable conditions the most advanced aberration corrected instruments have a spatial resolution approaching 2 nm. Although PEEM cannot compete with transmission or scanning electron microscopies for ultimate resolution, the technique is much more gentle and has the unique advantage of imaging structure as well as electronic and magnetic states on the nanoscale. Since the image contrast is derived from spatial variations in electron photoemission intensity, PEEM is ideal for interrogating both static and dynamic electronic properties of complex nanostructured materials. PEEM can be performed using a variety of photoexcitation sources including synchrotron emission, femtosecond laser pulses and conventional UV lamp emission. Each source has advantages, for example, fs laser excitation enables time-resolved imaging for study of ultrafast dynamics of surface intermediate states while tunable synchrotron sources allow chemically specific excitation. Even more detail can be extracted from energy resolved PEEM. Here, we review the key principles and contrast mechanisms of PEEM and briefly summarize materials applications of PEEM with examples of a thermally-induced structural phase transformation in barium titanate, inter-diffusion between thin metal copper and ruthenium layers, and multiphoton imaging of polystyrene nanoparticles on a silver coated substrate.

43 PARTICLE ACCELERATORS↗

Natural formation of linear defect structures in MoS 2

Near surface defects can significantly impact the quality of metallic interconnects and other interfaces necessary to create device structures incorporating two-dimensional materials. Furthermore, the impact of such defects can strongly depend on their organization. In this study, we present scanning tunneling microscopy images and tunneling spectroscopy of point and linear defects near the surface of natural MoS 2 . The point defects share similar structural and electronic characteristics and occur with comparable frequency as subsurface sulfur vacancies observed previously on natural MoS 2 . The linear defects observed here occur less frequently than the point defects but share the same depth profile and electronic structure. These data indicate that the linear defects are actually a one-dimensional organization of subsurface sulfur vacancies. Our density functional calculations agree with this assessment in that, for sufficient local defect concentrations, it is energetically more favorable for the defects to be organized in a linear fashion rather than as clusters or even isolated single point defects. Given these measurements were taken from naturally formed MoS 2 , this organization likely occurs during crystal formation. Considering the impact of one-dimensional organization on the local properties of layered materials, and the potential for them to be introduced purposefully during crystal formation, research into the formation mechanism and properties of these defects could enable new paths for defect engineering in MoS 2 -based systems.

2D materials↗

High energy x-ray phase contrast CT using glancing-angle grating interferometers

Purpose: The authors present initial progress toward a clinically compatible x-ray phase contrast CT system, using glancing-angle x-ray grating interferometry to provide high contrast soft tissue images at estimated by computer simulation dose levels comparable to conventional absorption based CT. Methods: DPC-CT scans of a joint phantom and of soft tissues were performed in order to answer several important questions from a clinical setup point of view. A comparison between high and low fringe visibility systems is presented. The standard phase stepping method was compared with sliding window interlaced scanning. Using estimated dose values obtained with a Monte-Carlo code the authors studied the dependence of the phase image contrast on exposure time and dose. Results: Using a glancing angle interferometer at high x-ray energy (∼45 keV mean value) in combination with a conventional x-ray tube the authors achieved fringe visibility values of nearly 50%, never reported before. High fringe visibility is shown to be an indispensable parameter for a potential clinical scanner. Sliding window interlaced scanning proved to have higher SNRs and CNRs in a region of interest and to also be a crucial part of a low dose CT system. DPC-CT images of a soft tissue phantom at exposures in the range typical for absorption based CT of musculoskeletal extremities were obtained. Assuming a human knee as the CT target, good soft tissue phase contrast could be obtained at an estimated absorbed dose level around 8 mGy, similar to conventional CT. Conclusions: DPC-CT with glancing-angle interferometers provides improved soft tissue contrast over absorption CT even at clinically compatible dose levels (estimated by a Monte-Carlo computer simulation). Further steps in image processing, data reconstruction, and spectral matching could make the technique fully clinically compatible. Nevertheless, due to its increased scan time and complexity the technique should be thought of not as replacing, but as complimentary to conventional CT, to be used in specific applications.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Processing of the laser Doppler velocimeter signals

The laser Doppler velocimeter (LDV) is a probeless technique that provides a remote measurement of mean and fluctuating velocities. The measurement is actually obtained from small particles embedded in the flow which scatter light from an illuminating laser beam interference pattern. A portion of this scattered light is collected by a photomultiplier which yields an electronic signal whose frequency is directly proportional to the velocity of the small particles. The purpose of this paper is to describe and critically compare three techniques most used to process this electronic signal. These techniques are: (1) spectrum analyzer - a frequency scanning filter (frequency domain instrument), (2) wide-band frequency tracker - a frequency lock loop (frequency domain instrument), and (3) high-speed frequency counter - an interval timer (time domain instrument). The study determines the ability of each technique to process the LDV signal and yield velocity data to be used in determining the flow characteristics.

Meyers, J. F.↗

Structural studies of lithium boro tellurite glasses doped with praseodymium and samarium oxides

Graphical abstract: [TeO{sub 4}] trigonal bipyramid structural unit, which is formed by two unequivalent pair of oxygen atoms: two equatorial oxygens (O{sub eq}) and two axial oxygens (O{sub ax}). Highlights: ► Pr{sup 3+} and Sm{sup 3+} doped LBT glasses have been prepared and characterized. ► LBT glasses present normal surfaces without metallic clusters. ► Raman spectra revealed the network modifying behaviour of dopant ions. -- Abstract: This paper reports the preparation and structural studies of praseodymium and samarium (0.5, 2 and 4 mol%) oxide doped lithium boro tellurite glasses. These materials were prepared by the quenching technique in a ceramic crucible at 950 °C. Structural characterization was performed by Raman spectroscopy, Scanning Electron Microscopy and Energy Dispersive X-ray spectroscopy techniques. Results from Raman analysis are in good agreement with those reported in the literature, revealing a normal glass structure for the host material. Understanding on how the glasses internal structure changed when the doping concentration increases was also assessed.

36 MATERIALS SCIENCE↗

Definition of mutually optimum NDI and proof test criteria for 2219 aluminum pressure vessels. Volume 3: Applications to rail defect evaluation

The technique for inspection of railroad rails containing transverse fissure defects was discussed. Both pulse-echo and pitch-catch inspection techniques were used. The pulse-echo technique results suggest that a multiple-scan approach using varying angles of inclination, three-surface scanning, and dual-direction traversing may offer promise of characterization of transverse defects. Because each scan is likely to produce a reflection indicating only a portion of the defect, summing of the individual reflections must be used to obtain a reasonably complete characterization of the defect. The ability of the collimated pitch-catch technique to detect relatively small amounts of flaw growth was shown. The method has a problem in characterizing the portions of the defect near the top surface or web intersection. The work performed was a preliminary evaluation of the prospects for automated mapping of rail flaws.

Schwartzberg, F. R.↗

Development of highly porous scaffolds based on bioactive silicates for dental tissue engineering

Graphical abstract: - Highlights: • Synthesis of an Mg-based glass-ceramic via the sol–gel technique. • The heat treatment of the glass-ceramic promoted the crystallization of akermanite. • Akermanite scaffolds coated with gelatin were successfully fabricated. • An HCAp layer was developed on the surface of all scaffolds after 9 days in SBF. - Abstract: Various scaffolding materials, ceramics and especially Mg-based ceramic materials, including akermanite (Ca{sub 2}MgSi{sub 2}O{sub 7}) and diopside (CaMgSi{sub 2}O{sub 6}), have attracted interest for dental tissue regeneration because of their improved mechanical properties and controllable biodegradation. The aim of the present work was the synthesis of an Mg-based glass-ceramic, which would be used for the construction of workable akermanite scaffolds. The characterization of the synthesized material was performed by Fourier Transform Infrared Spectroscopy (FTIR) X-Ray Diffractometry (XRD) and Scanning Electron Microscopy (SEM). Finally, the apatite forming ability of the scaffolds was assessed by immersion in simulated body fluid. The scaffolds were fabricated by the foam replica technique and were subsequently coated with gelatin to provide a functional surface for increased cell attachment. Finally, SEM microphotographs and FTIR spectra of the scaffolds after immersion in SBF solution indicated the inorganic bioactive character of the scaffolds suitable for the intended applications in dental tissue engineering.

36 MATERIALS SCIENCE↗

Electron Microscopy Approaches to Unraveling the Structure of Amorphous Materials

Determining atomic structures in crystalline materials—where atoms are arranged in rigid, periodic lattices—has been highly successful using probes such as electrons, X-rays, and neutrons. In contrast, amorphous materials, despite their ubiquity and technological importance, remain far more challenging to characterize with comparable accuracy and precision. This review highlights existing, emerging, and potential (scanning) transmission electron microscopy ((S)TEM) techniques for probing short- and medium-range order in amorphous materials. Approaches ranging from high-resolution (S)TEM imaging and selected electron diffraction pattern to four-dimensional STEM (4D-STEM) based pair distribution function, fluctuation electron microscopy, tomography, ptychography, and spectroscopic methods are discussed, emphasizing their ability to provide complementary insights across multiple length scales—from sub-angstrom local environments to nanometer-scale correlations. Here, we further explore the promise of multimodal and correlative strategies, as well as the growing role of machine learning and physics-informed AI in enabling real-time, quantitative interpretation of complex structural signatures. Together, these advances point toward a future where electron microscopy not only reveals the hidden order in amorphous systems but also establishes robust structure–property relationships, paving the way for materials innovation in disordered matter.

77 NANOSCIENCE AND NANOTECHNOLOGY↗

The Use of Laser Guidance Reduces Fluoroscopy Time for C-Arm Cone-Beam Computed Tomography-Guided Biopsies

PurposeWhen using laser guidance for cone-beam computed tomography (CBCT)-guided needle interventions, planned needle paths are visualized to the operator without the need to switch between entry- and progress-view during needle placement. The current study assesses the effect of laser guidance during CBCT-guided biopsies on fluoroscopy and procedure times.Materials and MethodsProspective data from 15 CBCT-guided biopsies of 8–65 mm thoracic and abdominal lesions assisted by a ceiling-mounted laser guidance technique were compared to retrospective data of 36 performed CBCT-guided biopsies of lesions >20 mm using the freehand technique. Fluoroscopy time, procedure time, and number of CBCT-scans were recorded. All data are presented as median (ranges).ResultsFor biopsies using the freehand technique, more fluoroscopy time was necessary to guide the needle onto the target, 165 s (83–333 s) compared to 87 s (44–190 s) for laser guidance (p < 0.001). Procedure times were shorter for freehand-guided biopsies, 24 min versus 30 min for laser guidance (p < 0.001).ConclusionThe use of laser guidance during CBCT-guided biopsies significantly reduces fluoroscopy time.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

The Structural, Electronic, and Magnetic Features of Co{sub 2}Mn{sub 1−x}Al{sub x}Ti (0 ≤ x ≤ 0.6) Heusler Alloys

The structural, electronic, and magnetic features of Co{sub 2}Mn{sub 1−x}Al{sub x}Ti (0 ≤ x ≤ 0.6) Heusler alloys (HAs) have been systematically investigated by experimental techniques (X-ray powder diffraction, scanning electron microscopy, and magnetization measurements) and ab initio theoretical calculations. Whole alloys have cubic structures at room temperature and exhibit ferromagnetic properties. The Curie temperature of Co{sub 2}Mn{sub 1−x}Al{sub x}Ti (x = 0) is approximately 790 K, which is compatible with other studies. By increasing Al content, the temperature dependence of magnetization trials has proved a linear diminishment on Curie temperature and saturation magnetization.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Performance efficiency and kinetic studies of water purification using ZnO and MgO nanoparticles for potassium permanganate

Zinc oxide (ZnO) and Magnesium oxide (MgO) nanoparticles (NPs) have been synthesized by solid–solid reaction technique. X-ray diffraction (XRD), scanning electron microscopy (SEM) and Fourier-transform infrared (FTIR) were used to investigate the structural properties of ZnO and MgO NPs. XRD indicates that structural of ZnO NPs has a hexagonal structure with space group P63mc. On the other hand, MgO NPs is cubic structure with space group Fm 3-bar m. The photocatalytic efficiency of both ZnO and MgO NPs as a catalyst was illustrated by studying the extreme quantity of potassium permanganate (KMnO{sub 4}) degradation rate in wastewater. KMnO{sub 4} achieved 17% and 25% degradation rate in 180 min for ZnO and MgO NPs, respectively. The experimental data were examined by the kinetic models of pseudo-first and second order as well as intra-particle diffusion. The obtained data is expressed well by the second-order kinetic model for both NPs. Moreover, according to the experimental results, MgO NPs has high-performance water purification as a comparison of ZnO NPs effect.

77 NANOSCIENCE AND NANOTECHNOLOGY↗

Highly Efficient Separation/Recycling Palladium(II) Ions from Aqueous Solutions by Silica Gel-Coated Graphene Oxide Modified with Mercapto Groups

The separation and recovery of precious metals from secondary resources is an extremely important and challenging task. Herein, a novel sorbent is successfully prepared by chemical grafting and utilized for the extraction and separation of Pd(II) ions from aqueous solutions. Various characterization techniques, including Fourier transform infrared spectroscopy, scanning electron microscopy, Brunauer–Emmett–Teller, X-ray photoelectron spectroscopy, and element analysis, are employed to study the structure, morphology, porous nature, and chemical composition of the as-prepared SiO{sub 2}@GO-SH nanocomposites. The adsorption of Pd(II) ions on the SiO{sub 2}@GO-SH can be described by the pseudo-second-order model and Langmuir isotherm model. The adsorption equilibrium has been attained within 90 min and the maximum adsorption capacity of 423.2 mg g{sup −1} was attained at pH 3.5 and T = 308 K. The results reveal that SiO{sub 2}@GO-SH exhibits an excellent adsorption performance towards Pd(II) ions. In addition, we have proposed the adsorption mechanism for Pd(II) ions on the SiO{sub 2}@GO-SH surface. The adsorption of Pd(II) in SiO{sub 2}@GO-SH is a chemisorption process, where partial adsorbed Pd(II) ions are reduced to Pd(0) by functional groups (-SH) in the SiO{sub 2}@GO-SH. The results indicate that SiO{sub 2}@GO-SH can serve as a promising sorbent for the efficient separation and recovery of palladium from the palladium-containing secondary resources.

36 MATERIALS SCIENCE↗

Corrosion Behavior of Q235 Steel Exposed in Deepwater of South China Sea

For the first time, the corrosion behavior of Q235 steel in 1200, 2000 and 3000 m deepwater of South China Sea for 0.5 year was reported in this study. The corrosion morphology and corrosion products properties were investigated using different techniques, such as 3D optical microscope, scanning electron microscope, x-ray diffraction analyzer and electrochemical impedance spectroscopy. The main environmental factors influencing the corrosion rate of Q235 in deep sea were discussed by applying gray relational analysis. The results indicated that uniform thinning occurred after exposure. A large number of tiny pits were distributed under the corrosion products with a two-layer structure. The corrosion rate and average pitting depth of samples exposed at 2000 m were lower than those exposed at 1200 and 3000 m, and the main environmental factors determining the variation of corrosion rate at different depths were temperature and dissolved oxygen concentration. Hydrostatic pressure had slight effect on the corrosion rate of Q235 steel, but promoted the formation of a more uniform corrosion morphology.

36 MATERIALS SCIENCE↗

Scanning Kelvin Probe Force Microscopy and Density Functional Theory Studies on the Surface Potential of the Intermetallics in AA7075-T6 Alloys

The surface potentials of Mg{sub 2}Si and Al{sub 7}Cu{sub 2}Fe intermetallic particles in AA7075-T6 alloys were investigated by scanning Kelvin probe force microscopy (SKPFM) technique. The experimental surface potentials of Mg{sub 2}Si and Al{sub 7}Cu{sub 2}Fe intermetallic particles relative to Al matrix were ranging from − 368 to − 265 mV and 480–500 mV, respectively. A theoretical method for assessing relative nobility of intermetallics in Al alloys was discussed through first principle calculation. The work functions and surface energies of Mg{sub 2}Si and Al{sub 7}Cu{sub 2}Fe surfaces were calculated by using density functional theory (DFT) method. The results showed that work functions and surface energies of Mg{sub 2}Si and Al{sub 7}Cu{sub 2}Fe intermetallics were influenced by the orientations of crystal face and terminal types. At the oxygen coverage of 1/4 ML and 1 ML, the theoretical surface potential differences between Mg{sub 2}Si intermetallics and Al matrix were increased by 10–560 mV and 0–620 mV, while those between Al{sub 7}Cu{sub 2}Fe intermetallics and Al matrix were increased by 62–360 mV and 102–331 mV. For the adsorption of oxygen atom, theoretical surface potentials of Mg{sub 2}Si and Al{sub 7}Cu{sub 2}Fe intermetallics relative to Al matrix had a close agreement with the experimental surface potentials. It was verified that DFT method was a valuable theoretical approach to assess the relative nobility of different phases in alloys.

36 MATERIALS SCIENCE↗

Intrafraction Motion in Stereotactic Body Radiation Therapy for Non-Small Cell Lung Cancer: Intensity Modulated Radiation Therapy Versus Volumetric Modulated Arc Therapy

Purpose: Stereotactic body radiation therapy (SBRT) for early-stage inoperable non-small cell lung cancer (NSCLC) patients delivers high doses that require high-precision treatment. Typically, image guidance is used to minimize day-to-day target displacement, but intrafraction position variability is often not corrected. Currently, volumetric modulated arc therapy (VMAT) is replacing intensity modulated radiation therapy (IMRT) in many departments because of its shorter delivery time. This study aimed to evaluate whether intrafraction variation in VMAT patients is reduced in comparison with patients treated with IMRT. Methods and Materials: NSCLC patients (197 IMRT and 112 VMAT) treated with a frameless SBRT technique to a prescribed dose of 3 × 18 Gy were evaluated. Image guidance for both techniques was identical: pretreatment cone beam computed tomography (CBCT) (CBCT{sub precorr}) for setup correction followed immediately before treatment by postcorrection CBCT (CBCT{sub postcorr}) for verification. Then, after either a noncoplanar IMRT technique or a VMAT technique, a posttreatment (CBCT{sub postRT}) scan was acquired. The CBCT{sub postRT} and CBCT{sub postcorr} scans were then used to evaluate intrafraction motion. Treatment delivery times, systematic (Σ) and random (σ) intrafraction variations, and associated planning target volume (PTV) margins were calculated. Results: The median treatment delivery time was significantly reduced by 20 minutes (range, 32-12 minutes) using VMAT compared with noncoplanar IMRT. Intrafraction tumor motion was significantly larger for IMRT in all directions up to 0.5 mm systematic (Σ) and 0.7 mm random (σ). The required PTV margins for IMRT and VMAT differed by less than 0.3 mm. Conclusion: VMAT-based SBRT for NSCLC was associated with significantly shorter delivery times and correspondingly smaller intrafraction motion compared with noncoplanar IMRT. However, the impact on the required PTV margin was small.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Microstructure characterization of as-fabricated and 475 Degrees C annealed U–7 wt.% Mo dispersion fuel in Al–Si alloy matrix

High-density uranium (U) alloys with an increased concentration of U are being examined for the development of research and test reactors with low enriched metallic fuels. The U-Mo fuel alloy dispersed in Al-Si alloy has attracted particular interest for this application. This paper reports our detailed characterization results of as-fabricated and annealed (475 Degrees C for 4 h) U-Mo dispersion fuels in Al-Si matrix with a Si concentration of 2 and 5 wt.%, named as As2Si, As5Si, An2Si, An5Si accordingly. Techniques employed for the characterization include scanning electron microscopy and transmission electron microscopy with specimen prepared by focused ion beam in situ lift-out. Fuel plates with Al-5 wt.% Si matrix consistently yielded thicker interaction layers developed between U-Mo particles and Al-Si matrix, than those with Al-2 wt.% Si matrix, given the same processing parameters. A single layer of interaction zone was observed in as-fabricated samples (i.e., As2Si, As5Si), and this layer mainly consisted of U3Si3Al2 phase. The annealed samples contained a two-layered interaction zone, with a Si-rich layer near the U-Mo side, and an Al-rich layer near the Al-Si matrix side. The U3Si5 appeared as the main phase in the Si-rich layer in An2Si sample, while both U3Si5 and U3Si3Al2 were identified in sample An5Si. The Al-rich layer in sample An2Si was amorphous, whereas that in sample An5Si mostly consisted of crystalline U(Al,Si)3, along with a small fraction of U(Al,Si)4 and U6Mo4Al43 phases. The influence of Si on the diffusion and reaction in the development of interaction layers in U(Mo)/Al(Si) is discussed in the light of growth-controlling mechanisms and irradiation performance.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Enhanced grindability of bastnaesite ore by ex-situ CO 2 treatment under the partial pressure of 0-100 psi

High grinding energy consumption has long constrained the sustainable development of mineral processing. This study introduces an innovative technology that employs ex-situ CO 2 treatment to enhance the grindability of bastnaesite ore. The grinding aid effect was evaluated under CO 2 partial pressures ranging from 0 psi to 100 psi using particle size distribution and the Bond work index (BWI), while the underlying mechanism was elucidated with various characterization techniques including inductively coupled plasma (ICP), scanning electron microscopy (SEM), thermogravimetric analysis (TGA), and Brunauer-Emmett-Teller (BET). The optimal grinding aid effect was achieved at 100 psi partial pressure, 50% slurry concentration, and 3 h reaction duration. Correspondingly, the P80 of the grinding product decreased from 81.76 μm to 72.73 μm and the BWI of bastnaesite ore decreased from 6.96 kW·h/t to 6.30 kW·h/t, a reduction of 9.48%. The grinding aid effect primarily resulted from the transformation of sparingly soluble carbonates like calcite and dolomite into more soluble bicarbonates, which created substantial cracks and pores, thereby reducing the ore's hardness and improving its grindability. By significantly saving grinding energy consumption while delivering environmental benefits, this technology exhibits great promise for further optimization and widespread adoption.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗