Search NASA⌕ Search

SEARCH · Search NASA

Results for “Testing Procedure”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,423 records · Page 79

Accelerated Scaling to Rapid Open-Air Fabrication of Durable Perovskite Solar Modules

The goals of this SETO project (DE-EE0008559, Accelerated Scaling to Rapid Open-Air Fabrication of Durable Perovskite Solar modules) are to address the principal challenges towards the successful commercialization of perovskite solar modules utilizing scalable, high-throughput open-air spray deposition. The successful outcome of the project will provide the foundation of an all open-air spray deposited perovskite solar module with hole transport layer (HTL), perovskite, electron transport layer (ETL), and barrier layer development while establishing a fundamental understanding of perovskite device behavior under accelerated aging conditions. Through this program, we have made significant progress towards a commercializable pathway for perovskites. (1) We’ve demonstrated the successful open-air deposition of perovskite and transport layer materials. These deposition methods were chosen for their inherent scalability, and open-air processing enables a significant reduction in processing costs. These methods are also compatible with high throughputs, demonstrating the fastest perovskite film deposition at these performance levels. (2) Development of a unique all-fiber laser scribing procedure provides a high-performance, low-cost method for further improvements in scalability. (3) Our group has also placed a unique emphasis on device stability. The development of testing standards for perovskite modules is required to thoroughly evaluate potential candidates for commercialization, and we’ve taken inspiration from current industry standards to provide an honest insight into the performance and reliability of our devices. (4) An extensive cost model detailing the specific contributions of each device layer and production component provides the most thorough evaluation of any perovskite technology against conventional silicon and compound semiconductor solar devices. The cost model is a critical advancement that will provide the foundation for evaluating the levelized cost of energy (LCOE) of this technology.

14 SOLAR ENERGY↗

SCALE 6.3 Validation: Reactor Physics

This study was performed to validate the SCALE/Polaris v6.3.0–PARCS v3.4.2 code procedure with the ENDF/B-VII.1 AMPX 56-group library for light-water reactor analysis by comparing the simulated results with the measured data for critical experiments and operating light-water reactors. Uncertainties of the SCALE/Polaris–PARCS code procedure for light-water reactor physics analysis were evaluated in the validation for key nuclear parameters such as reactivity, control bank work, temperature coefficients, and pin and assembly power peaking factors. In addition, the SCALE/TRITON v6.3.1 procedure with the ENDF/B-VII.1 and VIII.0 252-group and continuous-energy cross sections was validated for non-lightwater reactors including the HTR-10 reactor, the High-Temperature Test Reactor, the Molten Salt Reactor Experiment, and the Experimental Breeder Reactor II.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Polarized 3He gas circulating technologies for neutron analyzers

We outline our project to develop a circulating polarized helium-3 system for developing of large, quasi-continuously operating neutron analyzers. The project consisted of four areas: 1) Development of robust external cavity narrowed diode laser output with spectral line width < 0.17 nm and power of 2000 W. 2) Development of large glass polarizing cells using cell surface treatments to obtain long relaxation lifetimes. 3) Refinements of the circulation system with an emphasis on gas purification and materials testing. 4) Design/fabrication of a new polarizer system. 5) Preliminary testing of the new polarizer. 1. Developed Robust High-Power Narrowed Laser The optical configuration of the laser was discussed in the proposal and will be reviewed in the body of this report. The external cavity is configured to mutually lock the wavelength of five 10-bar laser stacks. All the logistical milestones were been met and critical subsystems- laser stack manifold and power divider, external laser cavity, and output telescope- were assembled and tested at low power. Each individual bar is narrowed to ~0.05 nm; when combined the laser has a cumulative spectral width of 0.17 nm across the entire beam due to variations of the bars central wavelength by +/- 0.1 nm, which is similar to that of Volume Bragg Grating narrowed laser bars. This configuration eliminates the free-running “pedestal” that occurs in other external cavity diode lasers. The full-scale laser was completed in 2016 and was used in both the older and newer helium polarizers. This laser was operated at 75% power for periods of up to 8 hours. Once installed, the spectrum became slightly broader (~.25 nm) at full power; this is likely due to very slight misalignments that occurred during handling. 2. Developed the processes to create uniform sintered sol-gel coatings. Our work on cell development comprised: 1) Production of large GE180 cells and explore different means of cell preparation, and 2) Development of apply sol-gel coatings to the interior of both borosilicate and aluminosilicate cells. We applied six sol-gel coatings. By modifying the mixture and developing procedures to drain and dry the cell, we produced visually uniform coatings on the interior of the cells. We now have perfected that process as described below in our report. We were able to accelerate the testing of cells using an ex situ method that avoids installing each cell into a polarizer. In the project’s last year, we conducted 38 external tests of 8 different cells. We also installed two sol-gel coated cells in our polarizers. We created cell with long ex situ relaxation lifetimes, one of which exceeded 40 hours. However, when installed in the polarizer the measured lifetime is 8 hours or less. 3. Demonstrated cycling of polarized gas and ex situ cell testing We are now cycling polarized gas from the polarizer to glass vessels and back. This has allowed us, for the first time, to make ex situ T1 measurements of polarizing cells without installing them into the polarizer itself. This has greatly improved our productivity in producing cells and evaluating our cell preparation processes. We continued development of the gas handling system in parallel with fabricating new polarizer. The integrated system was tested by the end of 2016. We now regularly cycle gas into and out of the polarizer. 4. Completed new polarizer infrastructure and control systems. We completed the new polarizer infrastructure in November 2016. The polarizer subsystems are 1) the frame, 2) the oil flow system, 3) the gas handling system, 4) the pressure vessel, with embedded solenoid, 5) cell mounting hardware with heat spreaders, and 6) electrical power and instrumentation. 5. Carried out initial tests of polarizer. We completed initial testing of the polarizer in April and May of 2017. These tests were carried out for periods up to 6 hours with laser power between 750 and 1300 Watts. The laser performed well and the polarization with asymptotic to 45 percent, which was below expectations. This low value resulted from a stationary thermal inversion in the cell that caused most of the laser power to be absorbed near the laser inlet window and deprived the lower portions of the cell of pumping laser light. Possible solutions to this problem include enhanced cooling of the cell near the laser entry and slight detuning of the laser. 6. Ongoing work. Our polarizer development efforts are ongoing to pursue our interest in neutron analyzers, nuclear targets, and providing helium for medical imaging. Current tests in the pipeline include: 1. Testing cooling enhancements to improve laser penetration of spectrally narrow lasers; 2. Testing of a cell with isolation valves that minimizes diffusive contact with gas handling hardware during polarization; 3. Testing of smaller hybrid cells with reduced alkali loading; 4. Producing polarized helium-3 for MRI imaging at the University of Missouri.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Spherical Platen versus Flat Platens in Compression Testing of PBX 9502

For ~15 years and perhaps longer, Pantex Plant has used a spherical platen in their compression load train when performing compression tests for Core Surveillance and HE Qualification. As our mechanical testing team at Los Alamos National Laboratory has always worked closely with our Pantex colleagues, and has maintained very similar practices in terms of calibration and testing, the author of this report has documented discussions with Pantex personnel (Robert Spence, et al.) dating back to ~2003, discussing the pros and cons of spherical platen use. LANL used spherical platens for a year or two, but determined issues and discontinued the practice. Based on multiple Engineering Evaluations (EE), LANL opportunities to watch Pantex procedures, it is our understanding that Pantex continued to use spherical platens from circa 2003 (or earlier) through summer 2019, despite the discontinued practice at LANL and the strong encouragement from LANL that spherical platens introduced error and should not be used. The short study reported here was intended to provide quantitative argument as to why spherical platens should not be used. As of a mechanical testing EE in August 2019, and after the testing of this LANL study was complete, LANL was informed by Pantex personnel that the practice of using spherical platens had recently been discontinued with no obvious problems or changes to the quality of the data. Although the urgency is gone for reporting our results, this is a brief quick summary of the data we collected.

42 ENGINEERING↗

Iso-uncertainty control in an experimental fluoroscopy system

Purpose: X-ray fluoroscopy remains an important imaging modality in a number of image-guided procedures due to its real-time nature and excellent spatial detail. However, the radiation dose delivered raises concerns about its use particularly in lengthy treatment procedures (>0.5 h). The authors have previously presented an algorithm that employs feedback of geometric uncertainty to control dose while maintaining a desired targeting uncertainty during fluoroscopic tracking of fiducials. The method was tested using simulations of motion against controlled noise fields. In this paper, the authors embody the previously reported method in a physical prototype and present changes to the controller required to function in a practical setting. Methods: The metric for feedback used in this study is based on the trace of the covariance of the state of the system, tr(C). The state is defined here as the 2D location of a fiducial on a plane parallel to the detector. A relationship between this metric and the tube current is first developed empirically. This relationship is extended to create a manifold that incorporates a latent variable representing the estimated background attenuation. The manifold is then used within the controller to dynamically adjust the tube current and maintain a specified targeting uncertainty. To evaluate the performance of the proposed method, an acrylic sphere (1.6 mm in diameter) was tracked at tube currents ranging from 0.5 to 0.9 mA (0.033 s) at a fixed energy of 80 kVp. The images were acquired on a Varian Paxscan 4030A (2048 × 1536 pixels, ∼100 cm source-to-axis distance, ∼160 cm source-to-detector distance). The sphere was tracked using a particle filter under two background conditions: (1) uniform sheets of acrylic and (2) an acrylic wedge. The measured tr(C) was used in conjunction with a learned manifold to modulate the tube current in order to maintain a specified uncertainty as the sphere traversed regions of varying thickness corresponding to the acrylic sheets in the background. Results: With feedback engaged, the tracking error was found to correlate well with the specified targeting uncertainty. Tracking of the fiducial was found to be robust to changes in the attenuation presented by the varying background conditions. For a desired uncertainty of 5.0 mm, comparison of the feedback framework with a comparable system employing fixed exposure demonstrated dose savings of 29%. Conclusions: This work presents a relation between a state descriptor, tr(C), the x-ray tube current used, and an estimate of the background attenuation. This relation is leveraged to modulate the tube current in order to maintain a desired geometric uncertainty during fluoroscopy. The authors’ work demonstrates the use of the method in a real x-ray fluoroscopy system with physical motion against varying backgrounds. The method offers potential savings in imaging dose to patients and staff while maintaining tracking uncertainty during fluoroscopy-guided treatment procedures.

60 APPLIED LIFE SCIENCES↗

Corrective Action Investigation Plan for Corrective Action Unit 414: Clean Slate III Plutonium Dispersion (TTR) Tonopah Test Range, Nevada, Revision 1

Corrective Action Unit (CAU) 414 is located on the Tonopah Test Range, which is approximately 130 miles northwest of Las Vegas, Nevada, and approximately 40 miles southeast of Tonopah, Nevada. The CAU 414 site consists of the release of radionuclides to the surface and shallow subsurface from the conduct of the Clean Slate III (CSIII) storage–transportation test conducted on June 9, 1963. CAU 414 includes one corrective action site (CAS), TA-23-03CS (Pu Contaminated Soil). The known releases at CAU 414 are the result of the atmospheric dispersal of contamination from the 1963 CSIII test. The CSIII test was a nonnuclear detonation of a nuclear device located inside a reinforced concrete bunker covered with 8 feet of soil. This test dispersed radionuclides, primarily uranium and plutonium, on the ground surface. The presence and nature of contamination at CAU 414 will be evaluated based on information collected from a corrective action investigation (CAI). The investigation is based on the data quality objectives (DQOs) developed on June 7, 2016, by representatives of the Nevada Division of Environmental Protection; the U.S. Air Force; and the U.S. Department of Energy (DOE), National Nuclear Security Administration Nevada Field Office. The DQO process was used to identify and define the type, amount, and quality of data needed to develop and evaluate appropriate corrective action alternatives for CAU 414.

54 ENVIRONMENTAL SCIENCES↗

Enhancing the cooling performance of thermocouples: a power-constrained topology optimization procedure

Abstract Heat pumping through thermoelectric devices has many advantages over traditional cooling. However, their current efficiency is a limiting factor in their implementation. In this paper, we approach the non-convex topology optimization of thermoelectrical elements for cooling applications through the method of moving asymptotes (MMA) to improve their cooling capabilities per watt usage. The optimization problem is defined for a given power budget, aiming for the minimum temperature with a known heat pumping need. The introduction of power as a constraint justifies the introduction of the voltage gradient across the thermocouple as a design variable to maintain the thermoelectrical device in its optimum power-to-heat extraction ratio. To better understand the convergence of this non-convex problem, we present a two-variable analytical thermoelectric optimization model. This example provides information on how to select the penalty parameters used to scale the three material coefficients involved in the problem to obtain lower objective values and better convergence using MMA. The analytical model shows the non-convexity of the problem and provides the recommendation to use penalization coefficients of the form $$p_k=p_{\sigma }>p_{\alpha }=1$$ p k = p σ > p α = 1 for the thermal conductivity, electrical conductivity, and Seebeck coefficients. We tested these penalization coefficients through optimizations of a model based on the 1MC10-031 commercial thermoelectric-cooler (TEC) using the finite element method (FEM). These penalization coefficients provided local minima without the need for volume constraints. With this procedure, we found designs that provided temperatures close to 10 degrees lower using 60% less semiconductor material volume compared to the initial design.

Gutiérrez, G. Reales↗

Modeling of ATR Fuel in DOE Standard Canisters with Helium Backfill

One pathway for road-ready and final disposition packaging configurations for the aluminum-clad spent nuclear fuel (ANSF) fuel is storage within helium backfilled sealed Department of Energy (DOE) standard canisters. The typical packaging configuration for the 15-foot DOE standard canisters places 10 advance test reactor (ATR) elements a basket, and three baskets are loaded within each DOE canister. During in-reactor operations and cooling pond storage conditions, oxyhydroxide layers form on the surface of the aluminum clad fuel. These layers produce hydrogen gas over time due to the fuel’s radiation field. As part of the packing procedure, the ATR fuel should be dried to remove any residual physio-/chemi- sorbed water bound to the surface. A 50-year CFD model of the DOE canister packaged with fuel was developed to provide a temperature profile for coupled chemical modeling of the conditions within the canister. The results of this modeling include results at fully saturated and fully dried fuel cladding conditions. In the associated experimental work, radiolysis experiments tests were completed in a helium environment, and G-values for the radiolytic production of hydrogen from the oxyhydroxide layers were provided. That reaction was coupled with the thermal profiles and gas-phase reactions to develop a 50-year model of the conditions within a sealed DOE canister with ATR fuel. For a nominal scenario of stored ATR fuel, after 50 years the model results give a 1.36 atm total pressure, 7% mole percent hydrogen, for the upper decay heat, 1.51 atm total pressure, 16% mole percent hydrogen, and for upper decay heat with undried fuel 2.6 atm total pressure, 15% mole percent hydrogen. No case modeled yields significant oxygen, and for the lower decay heat case that is modeled, hydrogen concentrations are under the 4% flammability limit after 50 years of storage. The modeled pressures for all cases modeled are below the pressure limit for the DOE standard sealed canister.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Formulation and Assessment of a Wash-Primer Containing Lanthanum “Tannate” for Steel Temporary Protection

Tannins are polyphenols synthesized by plants and useful for the coating industry as corrosion inhibitors. In addition, lanthanum salts have a great inhibitory effect on steel corrosion. The aim of this study was to obtain lanthanum “tannate” with adequate solubility to be incorporated as the corrosion inhibitor in a wash-primer. The “tannate” was obtained from commercial “Quebracho” tannin and 0.1 M La(NO{sub 3}){sub 3}. The soluble tannin was determined by the Folin–Denis reagent, while the concentration of Lanthanum was obtained by a gravimetric procedure. The protective action of “tannate” on SAE 1010 steel was evaluated by linear polarization curves and corrosion potential measurements. Lanthanum “tannate” was incorporated in a wash-primer formulation and tested by corrosion potential and ionic resistance measurements. The corrosion rate was also determined by the polarization resistance technique. Besides, the primer was incorporated in an alkyd paint system and its anticorrosion performance assessed in the salt spray cabinet and by electrochemical impedance spectroscopy. Results showed that lanthanum “tannate” primer inhibits the development of deleterious iron oxyhydroxides on the steel substrate and incorporated into a paint system had a similar behavior to the primer formulated with zinc tetroxychromate.

36 MATERIALS SCIENCE↗

Are current effectiveness criteria fit for purpose? Using a controversial strategic assessment as a test case

Highlights: • The effectiveness framework of Bond et al. (2015) is tested on a case study. • The strategic assessment of the proposed Browse LNG Precinct is evaluated. • The effectiveness framework is modified as a result of the analysis. • “Legitimacy” encompasses both pluralism and normative effectiveness. • Substantive effectiveness should include consideration of unintended consequences. - Abstract: The aim of this paper is to test the broader utility of the sustainability assessment effectiveness framework of Bond et al. (2015) by applying it to a controversial strategic assessment case study. The effectiveness framework comprises six dimensions: procedural effectiveness, substantive effectiveness, transactive effectiveness, normative effectiveness, pluralism, and knowledge and learning. It was originally developed to evaluate sustainability assessment at a system-wide level and it has not been previously applied to a specific case study. The analysis was conducted through document review and the first-hand experience of two of the authors who were involved in the case study in different capacities. The case study selected was the strategic assessment of the proposed Browse Liquefied Natural Gas (LNG) Precinct in Western Australia, which was conducted over the period 2007–2015 under the strategic assessment provisions of both the Western Australian and Australian Commonwealth environmental legislation. The framework provided a useful structure within which this complex case study could be explored, its strengths and weaknesses brought to light, and the interactions between the dimensions highlighted. We also found opportunities for refinement of the framework. As a result of this analysis we propose to replace the final three dimensions of the framework with legitimacy, where a legitimate process is one which all stakeholders agree is fair and which delivers an acceptable outcome for all parties, though we acknowledge the need for further conceptualisation of this dimension. We also suggest that the concept of substantive effectiveness should be expanded to incorporate the unintended consequences of impact assessment. Our research thus makes both a useful addition to the literature already published on the Browse case study, as well as to the literature on impact assessment effectiveness.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Recovery of DNA from fired and unfired cartridge casings: comparison of two DNA collection methods

For over 10 years, various studies have attempted to increase the recovery of DNA from ammunition by modifying the DNA collection, extraction, purification, and amplification procedures, with varying levels of success. This study focused on the “soaking” method of Montpetit & O’Donnell [1] and the “rinse-and-swab" method of Bille et al. [2]. First, testing for the presence of exogenous DNA, 210 boxed cartridges (brass, steel, and nickel-plated) from nine manufacturers were swabbed and DNA was extracted, concentrated, and quantified. Extracts that quantified > 0 ng/µL (44 of 210) were amplified and genotyped with GlobalFiler™. Of those, only one extract yielded two alleles indicating that the manufacturing and packaging of ammunition was virtually DNA free. Next, to obtain a baseline comparison of two DNA collection methods on a non-metallic substrate and identify a suitable number of cells to spot on cartridges, different DNA input amounts of primary human adult epidermal keratinocytes (HEKa) were tested. Thereafter, 300 brass and 300 nickel-plated, cartridges were spotted with HEKa cells containing ~5 ng of DNA, fired or unfired, and processed with either method. Finally, five methods representing hybrids of the soaking and rinse-and-swab methods were tested to determine if variations of those methods could be used to increase DNA yield and recovery. The results show that the soaking method consistently yielded more DNA than the rinse-and-swab method from a non-metallic substrate. However, the comparison study demonstrated that both methods performed comparably for cartridges. On average, the soaking method recovered 0.25 ng of DNA (5.1% recovery) and the rinse-and-swab method recovered 0.28 ng (5.8% recovery). However, average recoveries were significantly different among three analysts and considerable variation in yields were observed, possibly due to storage time. Furthermore, consistent with prior reports, the DNA recovered from brass casings was only 16% of that recovered from nickel-plated casings and the average yield of DNA from fired casings was reduced to 67% of unfired casings. Moreover, DNA extracts from brass or nickel-plated casings did not appear to contain amplification inhibitors and only 30/596 appeared severely degraded. Finally, both the published rinse-and-swab and soaking methods yielded more DNA than all modifications of the two methods. Overall, both methods yielded equivalent DNA quantities. Additionally, recovery of DNA from any given cartridge casing may be dependent on storage time as well as the skill, proficiency, and experience of the analyst and may reflect stochastic effects, particularly for casings containing low copy and/or degraded DNA.

59 BASIC BIOLOGICAL SCIENCES↗

A high-order discontinuous Galerkin method for fluid–structure interaction with efficient implicit–explicit time stepping

We present a high-order accurate scheme for coupled fluid–structure interaction problems. The fluid is discretized using a discontinuous Galerkin method on unstructured tetrahedral meshes, and the structure uses a high-order volumetric continuous Galerkin finite element method. Standard radial basis functions are used for the mesh deformation. The time integration is performed using a partitioned approach based on implicit–explicit Runge–Kutta methods. The resulting scheme fully decouples the implicit solution procedures for the fluid and the solid parts, which we perform using two separate efficient parallel solvers. We demonstrate up to fifth order accuracy in time on a non-trivial test problem, on which we also show that additional subiterations are not required. We solve a benchmark problem of a cantilever beam in a shedding flow, and show good agreement with other results in the literature. Finally, we solve for the flow around a thin membrane at a high angle of attack in both 2D and 3D, and compare with the results obtained with a rigid plate.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

A fast Fourier transform-based mesoscale field dislocation mechanics study of grain size effects and reversible plasticity in polycrystals

A numerical implementation of a non-local polycrystal plasticity theory based on a mesoscale version of the field dislocation mechanics theory (MFDM) of Acharya and Roy (2006) is presented using small-strain elasto-viscoplastic fast Fourier transform-based (EVPFFT) algorithm developed by Lebensohn et al. (2012). In addition to considering plastic flow and hardening only due to SSDs (statistically stored dislocations) as in the classic EVPFFT framework, the proposed method accounts for the evolution of GND (geometrically necessary dislocations) densities solving a hyperbolic-type partial differential equation, and GND effects on both plastic flow and hardening. This allows consideration of an enhanced strain-hardening law that includes the effect of the GND density tensor. The numerical implementation of a reduced version of the MFDM is presented in the framework of the FFT-based augmented Lagrangian procedure of Michel et al. (2001). A Finite Differences scheme combined with discrete Fourier transforms is applied to solve both incompatibility and equilibrium equations. The numerical procedure named MFDM-EVPFFT is used to perform full field simulations of polycrystal plasticity considering different grain sizes and their mechanical responses during monotonic tensile and reversible tension-compression tests. Using Voronoi tessellation and periodic boundary conditions, voxelized representative volume elements (RVEs) with different grain sizes are generated. With MFDM-EVPFFT, a Hall-Petch type scaling law is obtained in contrast with the conventional crystal plasticity EVPFFT. In the case of reversible plasticity, a stronger Bauschinger effect is observed with the MFDM-EVPFFT approach in comparison with conventional EVPFFT. Here, the origin of these differences is analyzed in terms of heterogeneity, GND density and stress evolutions during the compression stage.

36 MATERIALS SCIENCE↗

CODEX: Role of velocity substructure in the scaling relations of galaxy clusters

The use of galaxy clusters as cosmological probes relies on a detailed understanding of their properties. They define cluster selection and ranking linked to a cosmologically significant cluster mass function. Previous studies have employed small samples of clusters, concentrating on achieving the first calibrations of cluster properties with mass, while the diversity of cluster properties has been revealed via detailed studies. The large spectroscopic follow-up on the CODEX cluster sample with SDSS and NOT enables a detailed study of hundreds of clusters, lifting the limitations of previous samples. We aim to update the spectroscopic cluster identification of CODEX by running the spectroscopic group finder on the follow-up spectroscopy results and connecting the dynamical state of clusters to their scaling relations. We implemented a reproducible spectroscopic membership determination and cleaning procedures, based on the redMaPPer membership, running the spectroscopic group finder on the follow-up spectroscopy results and cleaning the membership for spectroscopic outliers. We applied the Anderson-Darling test for velocity substructure and analysed its influence on the scaling relations. We also tested the effect of the X-ray-to-optical centre offset on the scaling relations. We report on the scaling relations between richness, X-ray luminosity, and velocity dispersion for a complete sample of clusters with at least 15 members. Clusters with velocity substructure exhibit enhanced velocity dispersion for a given richness and are characterized by 2.5 times larger scatter. Clusters that have a strong offset in X-ray-to-optical centres have comparable scaling relations as clusters with substructure. We demonstrate that there is a consistency in the parameters of the scaling relations for the low- and high-richness galaxy clusters. Splitting the clusters by redshift, we note a decrease in scatter with redshift in all scaling relations. We localize the redshift range where a high scatter is observed to z < 0.15, which is in agreement with the literature results on the scatter. We note that the increase in scatter for both high- and low-luminosity clusters is z < 0.15, suggesting that both cooling and the resulting active galactic nucleus feedback are at the root of this scatter.

79 ASTRONOMY AND ASTROPHYSICS↗

Study on the ultrasonic inspection method using the full matrix capture for the in service railway wheel

The quality of wheel is especially important for the safety of high speed railway. In this paper, a new ultrasonic array inspection method, the Full Matrix Capture (FMC) has been studied and applied to the high speed railway wheel inspection, especially in the wheel web from the tread. Firstly, the principle of FMC and TFM algorithm is discussed, and then the new optimization is applied to the standard FMC; Secondly the fundamentals of optimization is described in detail and the performance is analyzed. Finally, the experiment has been built with a standard phased array block and railway wheel, and then the testing results are discussed and analyzed. It is demonstrated that this change for the ultrasonic data acquisition and image reconstruction has higher efficiency and lower cost comparing to the FMC's procedure.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

On the analysis and comparison of conformer-specific essential dynamics upon ligand binding to a protein

The native state of a protein consists of an equilibrium of conformational states on an energy landscape rather than existing as a single static state. The co-existence of conformers with different ligand-affinities in a dynamical equilibrium is the basis for the conformational selection model for ligand binding. In this context, the development of theoretical methods that allow us to analyze not only the structural changes but also changes in the fluctuation patterns between conformers will contribute to elucidate the differential properties acquired upon ligand binding. Molecular dynamics simulations can provide the required information to explore these features. Its use in combination with subsequent essential dynamics analysis allows separating large concerted conformational rearrangements from irrelevant fluctuations. We present a novel procedure to define the size and composition of essential dynamics subspaces associated with ligand-bound and ligand-free conformations. These definitions allow us to compare essential dynamics subspaces between different conformers. Our procedure attempts to emphasize the main similarities and differences between the different essential dynamics in an unbiased way. Essential dynamics subspaces associated to conformational transitions can also be analyzed. As a test case, we study the glutaminase interacting protein (GIP), composed of a single PDZ domain. Both GIP ligand-free state and glutaminase L peptide-bound states are analyzed. Our findings concerning the relative changes in the flexibility pattern upon binding are in good agreement with experimental Nuclear Magnetic Resonance data.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Cosmic shear measurements with Dark Energy Survey Science Verification data

Here, we present measurements of weak gravitational lensing cosmic shear two-point statistics using Dark Energy Survey Science Verification data. We also demonstrate that our results are robust to the choice of shear measurement pipeline, either ngmix or im3shape, and robust to the choice of two-point statistic, including both real and Fourier-space statistics. Our results pass a suite of null tests including tests for B-mode contamination and direct tests for any dependence of the two-point functions on a set of 16 observing conditions and galaxy properties, such as seeing, airmass, galaxy color, galaxy magnitude, etc. We furthermore use a large suite of simulations to compute the covariance matrix of the cosmic shear measurements and assign statistical significance to our null tests. We find that our covariance matrix is consistent with the halo model prediction, indicating that it has the appropriate level of halo sample variance. We also compare the same jackknife procedure applied to the data and the simulations in order to search for additional sources of noise not captured by the simulations. We find no statistically significant extra sources of noise in the data. We determined that the overall detection significance with tomography for our highest source density catalog is 9.7 σ. Cosmological constraints from the measurements in this work are presented in a companion paper [DES et al., Phys. Rev. D 94, 022001 (2016).].

79 ASTRONOMY AND ASTROPHYSICS↗

(2 + δ)-dimensional theory of the electromechanics of lipid membranes: Electrostatics

The coupling of electric fields to the mechanics of lipid membranes gives rise to intriguing electromechanical behavior, as, for example, evidenced by the deformation of lipid vesicles in external electric fields. Electromechanical effects are relevant for many biological processes, such as the propagation of action potentials in axons and the activation of mechanically gated ion channels. Currently, a theoretical framework describing the electromechanical behavior of arbitrarily curved and deforming lipid membranes does not exist. Purely mechanical models commonly treat lipid membranes as two-dimensional surfaces, ignoring their finite thickness. While holding analytical and numerical merit, this approach cannot describe the coupling of lipid membranes to electric fields and is thus unsuitable for electromechanical models. In a sequence of articles, we derive an effective surface theory of the electromechanics of lipid membranes, called the (2 + δ)-dimensional theory, which has the advantages of surface descriptions while accounting for finite thickness effects. The present article proposes a generic dimension reduction procedure relying on low-order spectral expansions. This procedure is applied to the electrostatics of lipid membranes to obtain the (2 + δ)-dimensional theory that captures potential differences across and electric fields within lipid membranes. Finally, this model is tested on different geometries relevant for lipid membranes, showing good agreement with the corresponding three-dimensional electrostatics theory.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗