Search NASA⌕ Search

SEARCH · Search NASA

Results for “Thick Target”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,423 records · Page 79

SU-F-J-177: A Novel Image Analysis Technique (center Pixel Method) to Quantify End-To-End Tests

Purpose: To implement a novel image analysis technique, “center pixel method”, to quantify end-to-end tests accuracy of a frameless, image guided stereotactic radiosurgery system. Methods: The localization accuracy was determined by delivering radiation to an end-to-end prototype phantom. The phantom was scanned with 0.8 mm slice thickness. The treatment isocenter was placed at the center of the phantom. In the treatment room, CBCT images of the phantom (kVp=77, mAs=1022, slice thickness 1 mm) were acquired to register to the reference CT images. 6D couch correction were applied based on the registration results. Electronic Portal Imaging Device (EPID)-based Winston Lutz (WL) tests were performed to quantify the errors of the targeting accuracy of the system at 15 combinations of gantry, collimator and couch positions. The images were analyzed using two different methods. a) The classic method. The deviation was calculated by measuring the radial distance between the center of the central BB and the full width at half maximum of the radiation field. b) The center pixel method. Since the imager projection offset from the treatment isocenter was known from the IsoCal calibration, the deviation was determined between the center of the BB and the central pixel of the imager panel. Results: Using the automatic registration method to localize the phantom and the classic method of measuring the deviation of the BB center, the mean and standard deviation of the radial distance was 0.44 ± 0.25, 0.47 ± 0.26, and 0.43 ± 0.13 mm for the jaw, MLC and cone defined field sizes respectively. When the center pixel method was used, the mean and standard deviation was 0.32 ± 0.18, 0.32 ± 0.17, and 0.32 ± 0.19 mm respectively. Conclusion: Our results demonstrated that the center pixel method accurately analyzes the WL images to evaluate the targeting accuracy of the radiosurgery system. The work was supported by a Research Scholar Grant, RSG-15-137-01-CCE from the American Cancer Society.

60 APPLIED LIFE SCIENCES↗

Flat Field Anomalies in an X-ray CCD Camera Measured Using a Manson X-ray Source (HTPD 08 paper)

The Static X-ray Imager (SXI) is a diagnostic used at the National Ignition Facility (NIF) to measure the position of the X-rays produced by lasers hitting a gold foil target. The intensity distribution taken by the SXI camera during a NIF shot is used to determine how accurately NIF can aim laser beams. This is critical to proper NIF operation. Imagers are located at the top and the bottom of the NIF target chamber. The CCD chip is an X-ray sensitive silicon sensor, with a large format array (2k x 2k), 24 {micro}m square pixels, and 15 {micro}m thick. A multi-anode Manson X-ray source, operating up to 10kV and 10W, was used to characterize and calibrate the imagers. The output beam is heavily filtered to narrow the spectral beam width, giving a typical resolution E/{Delta}E {approx} 10. The X-ray beam intensity was measured using an absolute photodiode that has accuracy better than 1% up to the Si K edge and better than 5% at higher energies. The X-ray beam provides full CCD illumination and is flat, within {+-}1% maximum to minimum. The spectral efficiency was measured at 10 energy bands ranging from 930 eV to 8470 eV. We observed an energy dependent pixel sensitivity variation that showed continuous change over a large portion of the CCD. The maximum sensitivity variation occurred at 8470 eV. The geometric pattern did not change at lower energies, but the maximum contrast decreased and was not observable below 4 keV. We were also able to observe debris, damage, and surface defects on the CCD chip. The Manson source is a powerful tool for characterizing the imaging errors of an X-ray CCD imager. These errors are quite different from those found in a visible CCD imager.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Impact of target-to-background ratio, target size, emission scan duration, and activity on physical figures of merit for a 3D LSO-based whole body PET/CT scanner

The aim of our work is to describe the way in which physical figures of merit such as contrast-to-noise ratio (CNR) behave when varying acquisition parameters such as emission scan duration (ESD) or activity at the start of acquisition (A{sub acq}) that in clinical practice can be selected by the user, or object properties such as target dimensions or target-to-background (T/B) ratio, which depend uniquely on the intrinsic characteristics of the object being imaged. Figures of merit, used to characterize image quality and quantitative accuracy for a 3D-LSO based PET/CT scanner, were studied as a function of ESD and A{sub acq} for different target sizes and T/B ratios using a multivariate approach in a wide range of conditions approaching the ones that can be encountered in clinical practice. An annular ring of water bags of 3 cm thickness was fitted over an IEC phantom in order to obtain counting rates similar to those found in average patients. The average scatter fraction (SF) of the modified IEC phantom was similar to the mean SF measured on patients with a similar scanner. A supplemental set of micro-hollow spheres was positioned inside the phantom. The NEMA NU 2-2001 scatter phantom was positioned at the end of the IEC phantom to approximate the clinical situation of having activity that extends beyond the scanner. The phantoms were filled with a solution of water and {sup 18}F (12 kBq/mL) and the spheres with various T/B ratios of 22.5, 10.3, and 3.6. Sequential imaging was performed to acquire PET images with varying background activity concentrations of about 12, 9, 6.4, 5.3, and 3.1 kBq/mL, positioned on the linear portion of the phantom's NECR curve, well below peak NECR of 61.2 kcps that is reached at 31.8 kBq/mL. The ESD was set to 1, 2, 3, and 4 min/bed. With T/B ratios of 3.6, 10.3, and 22.5, the 13.0, 8.1, and 6.5 mm spheres were detectable for the whole ranges of background activity concentration and ESD, respectively. The ESD resulted as the most significant predictor of CNR variance, followed by T/B ratio and the cross sectional area of the given sphere. Only last comes A{sub acq} with a weight more than halved with respect to ESD. Thus, raising ESD seems to be much more effective than raising A{sub acq} in order to obtain higher CNR, which is the physical figure of merit closely related with target detectability, at least in the simple task of the signal known exactly background known exactly model.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Mitigating laser-imprint effects in direct-drive inertial confinement fusion implosions with an above-critical-density foam layer

Low-density foams of low-/mid-Z materials have been previously proposed to mitigate laser imprint for direct-drive inertial confinement fusion (ICF). For foam densities above the critical density of the drive laser, the mechanism of laser-imprint mitigation relies on the reduced growth rate of Rayleigh–Taylor instability because of the increased ablation velocity and density scale length at the ablation surface. Experimental demonstration of this concept has been limited so far to planar-target geometry. The impact of foams on spherical implosions has not yet been explored in experiments. To examine the viability of using an above-critical-density foam layer to mitigate laser-imprint effects in direct-drive ICF implosions on OMEGA, we have performed a series of 2-D DRACO simulations with state-of-the-art physics models, including nonlocal thermal transport, cross-beam energy transfer, and first-principles equation-of-state tables. The simulation results indicate that a 40-μm-thick CH or SiO 2 foam layer with a density of p = 40 mg/cm 3 added to a D2-filled polystyrene (CH) capsule can significantly improve the moderate-adiabat (α ≈ 3) implosion performance. In comparison with the standard CH target implosion, an increase of neutron yield by a factor of 4 to 8 and the recovery of 1-D compression pR are predicted by DRACO simulations for a foam-target surface roughness of σ rms ≤ 0.5 μm. These encouraging results could readily facilitate experimental demonstrations of laser-imprint mitigation with an above-critical-density foam layer.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Natural nickel as a proton beam energy monitor for energies ranging from 15 to 30 MeV

The degradation of proton beam energy within a target stack was monitored via product nuclide ratios at the Los Alamos Isotope Production Facility (LANL-IPF). Nuclear reaction channels employed as energy monitors included Nat Ni(p,x) 57 Co and Nat Ni(p,x) 57 Ni. Natural nickel foils (thicknesses 0.025 mm) were used to determine proton beam energies ranging from 15 to 30 MeV. Energy values were estimated from a fitted 57 Ni/ 57 Co production activity ratio curve, which, in turn, was calculated from formation cross section data. Isotope production yields in the low energy “C” slot at LANL-IPF are very sensitive to beam energy, and differences of several MeV can translate into a drastic effect on overall production yields and radiochemical purity. Furthermore proton energies determined in this target stack position using nickel foils will serve as a basis to optimize radionuclide production in terms of product yield maximization and by-product minimization.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

A new woven composite constitutive model validated by shock wave experiments

In this paper, we present results of plate impact simulations of shock compressed woven glass fiber-reinforced plastic (GRP) performed using the Arbitrary Lagrangian–Eulerian three-dimensional finite element code. A hyperelastic large-strain-based empirical Continuum Damage Mechanics (CDM) formulation is employed to describe damage initiation and growth in the shock-compressed GRP. The model parameters calibration scheme utilizes the Velocity Interferometer System for Any Reflector normal particle velocity measurements at the free surface of the GRP target plates. The impact velocity in the experiments ranged from 8.5 to 418 m/s. The finite element model considered planar 0°/90° bidirectional plies with an individual ply thickness of 0.68 mm, stacked to reach a total laminate thickness of 6.8 mm. The anisotropic elastic strains were estimated from the experimentally determined tetragonal symmetry stiffness matrix for the GRP. The strain-based damage model captures several salient features observed in the measured free surface particle wave profiles, including the shock rise time, onset of Elastic—Elastic Cracking, and the shape of the nonlinear portion of the experimental particle velocity profiles. Furthermore, the CDM model predicts the dominant damage mode to be matrix microcracking due to shear and the associated bulk expansion (bulking) under the global compressive loading in the plate impact configuration.

42 ENGINEERING↗

Influence of Al{sub 2}O{sub 3} layer insertion on the electrical properties of Ga-In-Zn-O thin-film transistors

To investigate the influence of ionic/covalent interface of Al{sub 2}O{sub 3}/SiO{sub 2} gate insulator on the electrical properties of thin-film transistors (TFTs) with ionic Ga-In-Zn-O (GIZO) semiconducting channel layers, Al{sub 2}O{sub 3} layers of different thickness were introduced between SiO{sub 2} and GIZO using plasma-enhanced atomic layer deposition. The GIZO layers were obtained by DC magnetron sputtering using a GIZO target (Ga:In:Zn = 1:1:1 mol. %). The GIZO TFTs with an Al{sub 2}O{sub 3}/SiO{sub 2} gate insulator exhibited positive threshold voltage (V{sub th}) shift (about 1.1 V), V{sub th} hysteresis suppression (0.23 V), and electron mobility degradation (about 13%) compared with those of a GIZO TFT with SiO{sub 2} gate insulator by the influence of ionic/ionic and ionic/covalent interface at Al{sub 2}O{sub 3}/GIZO and Al{sub 2}O{sub 3}/SiO{sub 2}, respectively. To clarify the origin of the positive V{sub th} shift, the authors estimated the shifts of flatband voltage (0.4 V) due to the dipole and the fixed charge (−1.1 × 10{sup 11}/cm{sup 2}) at Al{sub 2}O{sub 3}/SiO{sub 2} interface, from capacitance–voltage data for Pt/Al{sub 2}O{sub 3}/SiO{sub 2}/p-Si capacitors. Based on these experimental data, the authors found that the positive V{sub th} shift (1.1 V) could be divided into three components: the dipole (−0.4 V) and fixed charge (0.15 V) at the SiO{sub 2}/Al{sub 2}O{sub 3} interface, and the fixed charge (1.35 V) at the Al{sub 2}O{sub 3}/GIZO interface. Finally, it is noted that heterointerface of SiO{sub 2}/Al{sub 2}O{sub 3}/GIZO stacks is important not only to recognize mechanism of V{sub th} shift but also to design future TFTs with high-k dielectrics and low operating voltage.

42 ENGINEERING↗

Perturbation of Brachypodium distachyon CELLULOSE SYNTHASE A4 or 7 results in abnormal cell walls

Cellulose is an integral component of the plant cell wall and accounts for approximately forty percent of total plant biomass but understanding its mechanism of synthesis remains elusive. CELLULOSE SYNTHASE A (CESA) proteins function as catalytic subunits of a rosette-shaped complex that synthesizes cellulose at the plasma membrane. Arabidopsis thaliana and rice (Oryza sativa) secondary wall CESA loss-of-function mutants have weak stems and irregular or thin cell walls. Here, we identify candidates for secondary wall CESAs in Brachypodium distachyon as having similar amino acid sequence and expression to those characterized in A. thaliana, namely CESA4/7/8. To functionally characterize BdCESA4 and BdCESA7, we generated loss-of-function mutants using artificial microRNA constructs, specifically targeting each gene driven by a maize (Zea mays) ubiquitin promoter. Presence of the transgenes reduced BdCESA4 and BdCESA7 transcript abundance, as well as stem area, cell wall thickness of xylem and fibers, and the amount of crystalline cellulose in the cell wall. These results suggest BdCESA4 and BdCESA7 play a key role in B. distachyon secondary cell wall biosynthesis.

59 BASIC BIOLOGICAL SCIENCES↗

Low Cost Hydrogen Storage at 875 Bar Using Steel Liners and Steel Wire Wraps

The Department of Energy’s (DOE) Fuel Cell Technologies Office (FCTO) within the Office of Energy Efficiency and Renewable Energy (EERE) supports research and development activities leading to the development of low-cost, high-pressure hydrogen storage systems for use in hydrogen refueling stations (forecourt). The specific goals of this project were to develop and produce a prototype of a pressure vessel to safely store gaseous hydrogen at 875 bar that meets the American Society of Mechanical Engineers (ASME) Boiler and Pressure Vessel Section VIII, Division 3 design code for service in hydrogen (Article KD-10) and meets the DOE storage tank cost target of <$1000/kg stored hydrogen (H 2 ). The pressure vessel designed and prototyped as part of this study utilizes a standard ASME approved, 406 mm diameter, 31.7 mm thick wall, and 9.14m long, liner with a capacity of 765 liters and rated for a pressure of up to 460 bar. The liner was wrapped with high strength steel wires to boost its pressure rating to 875 bars. The process of wrapping metal liners with a high strength steel wire, a WireTough patented technology, was first demonstrated on short cylinders that were 1.9 m long but of the same diameter and wall thickness as the 9.1 m long, 765 L cylinders. Subsequently, full length cylinders that were 9.14 m long were designed and certified under the applicable ASME Design Codes. Two prototype cylinders were wire wrapped to demonstrate the manufacturability. Following is a bulleted summary of the accomplishments of the project that ended on August 31, 2018.

25 ENERGY STORAGE↗

Diamondlike carbon protective coatings for IR materials

Diamondlike carbon (DLC) films have the potential to protect optical windows in applications where it is important to maintain the integrity of the specular transmittance of these films on ZnS and ZnSe infrared transmitting windows. The films must be adherent and durable such that they protect the windows from rain and particle erosion as well as chemical attack. In order to optimize the performance of these films, 0.1 micro m thick diamondlike carbon films were deposited on fused silica and silicon wafers, using three different methods of ion beam deposition. One method was sputter deposition from a carbon target using an 8 cm ion source. The merits of hydrogen addition were experimentally evaluated in conjunction with this method. The second method used a 30 cm hollow cathode ion source with hydrocarbon/Argon gases to deposit diamondlike carbon films from the primary beam at 90 to 250 eV. The third method used a dual beam system employing a hydrocarbon/Argon 30 cm ion source and an 8 cm ion source. Films were evaluated for adherence, intrinsic stress, infrared transmittance between 2.5 and 50 micro m, and protection from particle erosion. An erosion test using a sandblaster was used to give quantitative values of the protection afforded to the fused silica by the diamondlike carbon films. The fused silica surfaces protected by diamondlike carbon films were exposed to 100 micro m diameter SiO particles at 60 mi/hr (26.8/sec) in the sandblaster.

Mirtich, M. J.↗

ANS Winter 2024 Summary: Optimizing the ATF-2Ramp Power Profile

When the Halden Boiling Water Reactor closed down in 2018, a need to restore the capability for in-reactor power ramp testing arose. Such testing is valuable for studying pellet-clad interaction phenomena in nuclear fuels. The data from these studies is of great interest to a number of research programs, including the accident-tolerant fuel (ATF) program at Idaho National Laboratory (INL). In 2022, Woolstenhulme et al. proposed several power ramp testing ideas using facilities at INL, including irradiation in the Transient Reactor Test Facility (better known as TREAT) and the Advanced Test Reactor (ATR) [1]. Worrall et al. [2] and Labossiere-Hickman et al. [3] subsequently performed feasibility studies for the ATR testing options in 2023. This summary further investigates the three-pin trefoil design (Fig. 1) for the proposed ATF-2Ramp Experiment discussed in Labossiere-Hickman et al. [3]. ATF-2Ramp is designed to operate in the center flux trap (CFT) of the ATR during a powered axial locator mechanism (PALM) cycle: a short, variable-powered cycle with an asymmetric power distribution. Previously, it was shown that tailoring the thickness of the hafnium (Hf) neutron shields (“mini-shrouds”) surrounding each pin offered a degree of control sufficient to achieve the programmatic linear heat generation rate (LHGR) targets for ATF-2Ramp during the high-power period of a PALM cycle. New work involves shortening the experiment test train for consistency with the fuel pins in ATF-2D [4] and then shaping the axial power profile of the three test pins.

11 - NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Effects of nanosecond-scale prepulse on generation of high-energy protons in target normal sheath acceleration

A pulse cleaner based on noncollinear optical-parametric amplification and second-harmonic generation processes is used to improve the contrast of a laser of peak intensity {approx}2 Multiplication-Sign 10{sup 19} W/cm{sup 2} to {approx}10{sup 11} at 100 ps before the peak of the main pulse. A 7 MeV proton beam is observed when a 2.5 {mu}m-thick Al foil is irradiated by this high-contrast laser. The maximum proton energy decreases to 2.9 MeV when a low-contrast ({approx}10{sup 8}) laser is used. Two-dimensional particle-in-cell simulations combined with MULTI simulations show that the maximum proton energy sensitively relies on the detecting direction. The ns-time-scale prepulse can bend a thin target before the main pulse arrives, which reduces maximum proton energy in the target normal sheath acceleration.

43 PARTICLE ACCELERATORS↗

WE-G-BRE-09: Targeted Radiotherapy Enhancement During Accelerated Partial Breast Irradiation (ABPI) Using Controlled Release of Gold Nanoparticles (GNPs)

Purpose: Several studies have demonstrated low rates of local recurrence with brachytherapy-based accelerated partial breast irradiation (APBI). However, long-term outcomes on toxicity (e.g. telangiectasia), and cosmesis remain a major concern. The purpose of this study is to investigate the dosimetric feasibility of using targeted non-toxic radiosensitizing gold nanoparticles (GNPs) for localized dose enhancement to the planning target volume (PTV) during APBI while reducing dose to normal tissue. Methods: Two approaches for administering the GNPs were considered. In one approach, GNPs are assumed to be incorporated in a micrometer-thick polymer film on the surface of routinely used mammosite balloon applicators, for sustained controlled in-situ release, and subsequent treatment using 50-kVp Xoft devices. In case two, GNPs are administered directly into the lumpectomy cavity e.g. via injection or using fiducials coated with the GNP-loaded polymer film. Recent studies have validated the use of fiducials for reducing the PTV margin during APBI with 6 MV beams. An experimentally determined diffusion coefficient was used to determine space-time customizable distribution of GNPs for feasible in-vivo concentrations of 43 mg/g. An analytic calculational approach from previously published work was employed to estimate the dose enhancement due to GNPs (2 and 10 nm) as a function of distance up to 1 cm from lumpectomy cavity. Results: Dose enhancement due to GNP was found to be about 130% for 50-kVp x-rays, and 110% for 6-MV external beam radiotherapy, 1 cm away from the lumpectomy cavity wall. Higher customizable dose enhancement could be achieved at other distances as a function of nanoparticle size. Conclusion: Our preliminary results suggest that significant dose enhancement can be achieved to residual tumor cells targeted with GNPs during APBI with electronic brachytherapy or external beam therapy. The findings provide a useful basis for developing nanoparticle-aided APBI, with potential to significantly reduce normal tissue/skin toxicity.

60 APPLIED LIFE SCIENCES↗

Diagnostics: Chapter 8 of the special issue: on the path to tokamak burning plasma operation

This chapter presents the activity conducted by the ITPA topical group (TG) on Diagnostics over about the last 15 years. Following a general introduction of the ITER Diagnostics led by their measurement roles, the document is organized in several subchapters detailing the design support, research and development activity conducted by each of the specialist working groups (WGs) of the TG. Please note that the magnetic diagnostics were supported at the TG without a specific WG. Their status is included in the general introduction. In the following some highlights of the subchapter’s contents are provided. Recent advances in ITER first wall (FW) diagnostics for the measurements of plasma-metallic wall interaction in support of the ITER research plan are reported. An InfraRed imaging Video Bolometer for ITER has been developed and tested on several tokamaks to measure the radiated power loss. A laser-induced breakdown spectroscopy (LIBS) technique which utilizes a pulsed laser beam to ablate locally by forming a crater, will measure local tritium inventory in the FW material. Real-time Residual Gas Analyzers will measure the neutral gas composition in a divertor port and an equatorial port during plasma operation. Due to the full metallic FW environment, the plasma-wall interaction in ITER will face several challenges such as the compromised radiated power and divertor heat flux measurements by reflection. Ray tracing and analysis codes have been developed to eliminate and correct the effects of reflection in the measurements. The characteristics of the reflecting surfaces depending on the roughness and angle of the incidence have been measured by dedicated experiments, and the results were applied to the reflection elimination. For the measurement of the metallic impurity radiation induced by eroded metallic atoms, a vacuum ultraviolet spectrometer has been developed and tested. An extensive thermonuclear diagnostic suite will be required to support the operation of ITER and the planned experimental program for future burning plasma experiments. Due to the harsh environmental conditions, the implementation of diagnostic systems in ITER is a major challenge. These conditions include high levels of neutron and gamma fluxes, neutron heating, particle bombardment. Therefore, the selection and design of diagnostic systems must take into account a number of phenomena previously unseen in diagnostic design. For this reason, the measurement of neutrons and confined or lost fast ions, with particular emphasis on alpha particles, is critical to ITER. The diagnostics associated with these measurements will be important for future plasma-burning experiments at ITER. The high neutron emission and very large plasma size in ITER make neutron diagnostics the main diagnostic method used to measure plasma parameters such as fusion power, fusion power density, ion temperature, energy of fast ions and their spatial distributions in the plasma core. Active spectroscopy techniques are methods where a neutral particle beam is injected into the plasma and information on plasma parameters is extracted from the measurement of line emission resulting from the beam-plasma interaction, either by plasma ions or by beam atoms. Spatial localization is achieved by crossing the beamline and multiple observation lines. The ITER plasma will be a high temperature, moderately dense, fully ionized collisional plasma. The plasma facing surfaces are principally metallic being fashioned from beryllium or tungsten but many other elements, arising from either structural or from operational needs, may enter this plasma. The energy range of the emitted photons range from meV (infra-red) to multi keV (x-rays) and originate from all areas of the plasma volume. The primary role of passive emission diagnostics is to identify what is in the plasma from spectral signatures. Extracting quantitative information from these measurements such as impurity content, ion temperature, rotation, degree of detachment and radiated power depends on calibrated instruments, a physics model of the atomic and molecular processes and plasma transport and an analysis workflow that takes into account environmental effects such as reflections. The particular needs for ITER have prompted a multi-machine, many-year effort to address all these aspects and this chapter reviews the work on diagnostic design, experiments and new analysis techniques. An overview of the laser diagnostics to be implemented on ITER is also provided in this paper. This includes descriptions of the Thomson scattering in the core, edge and divertor regions, polarimetry and interferometry diagnostics used for measuring plasma density and also measurements of helium density in the divertor using Laser Induced Flourescence. Techniques which can allow improvements on current measurements are also addressed in particular expanding poloidal polarimetry measurements to measure field fluctuations and proposed use of dispersion interferometery which has a number of advantages over existing methods. This paper identifies particular areas where further research and testing on existing tokamaks is useful even at this advanced stage to inform the design of diagnostics for ITER. Outstanding areas of concern for the implementation of laser diagnostics, in particular with a view to reliable operation are identified. An overview of the latest developments of microwave diagnostic systems and techniques is given. The primary focus is the contributions for ITER—the next step burning plasma experiment—which is supplemented by describing recent progress of techniques applicable for fusion experiments beyond ITER. The contributions are intentionally kept concise, and are being supplemented by a rich list of references for further studies. Radiation induced effects are receiving continuous and well-deserved attention of the ITER diagnostic community and they are in many cases one of the primary design drivers of the ITER diagnostic systems. The paper summarizes recent progress in this area focusing primarily on the ITER diagnostics but in some cases provides also outlook for the possible solutions for even more demanding radiation environment of fusion reactors beyond ITER. Despite advancements in the area of modeling and simulation of various radiation induced effects, experimental testing in a nuclear environment as close as possible to the target one is still seen as unavoidable for proper qualification of particular diagnostic functional elements. Recent advancement within three diagnostic areas: optical diagnostics, magnetics and bolometers is covered. Encouraging results on qualification of silica glass vacuum window assemblies are presented. In the area of magnetic sensors, progress of irradiation tests performed on ITER in-vessel LTCC inductive sensors is presented with outlook for novel technological approaches to inductive sensors utilizing thick printing and photolithography technologies being highlighted. Summary of advancements in the area of steady state magnetic field sensors based on Hall effect is given. New results of neutron irradiation test of the ITER borosilicate glass inserts for vacuum electrical feedthroughs are summarized finding negligible swelling at target level of neutron fluence. Off-line irradiation tests of fiber optic current sensors for plasma current measurement demonstrated that both for gamma doses up to 5 MGy and a total neutron fluence up to 10 15 cm −2 , radiation induced changes are still compatible with required measurement accuracy on ITER. The ITER bolometers are given as an example how considering radiation effects may influence the diagnostic design. Finally, outlook for future main R&D directions is outlined. All optical and laser-based diagnostics in ITER will be using mirrors to guide plasma radiation toward detectors, cameras and sensors. In the hostile plasma, radiation and particle environment the optical characteristics of diagnostic mirrors will degrade directly affecting the entire performance of involved diagnostic systems. An assessment of factors affecting mirror performance is provided. Among the prime adverse factors are deposition of plasma impurities, sputtering of mirror surface and steam ingress in the vicinity of mirrors. Within the International Tokamak Physics Activity with active support by ITER central team and domestic agencies, the structured research and development (R&D) program on mitigation of risks for diagnostic mirrors is underway. Within this program the mirror material development, the passive mitigation of mirror degradation by using diagnostic ducts and shutters along with an active mirror recovery program comprising the in-situ mirror cleaning and calibration is underway. Recent developments in diagnostic mirror R&D are described in this Chapter along with an example of their implementation of R&D solutions in ITER Infrared Thermography diagnostic. An assessment of still open engineering and physics questions, considerations on mirror risks during an early phase of ITER operation are given along with an overview of diagnostic mirror evolution in the late ITER operation stage toward the demonstration fusion power plant. Several crucial areas of diagnostic R&D outlined in ITER Research Plan are addressed. The basic control groups in a fusion reactor can be broken-down in five categories: (1) plasma position, magnetic configuration, and plasma current control, (2) profile control and confinement optimization, (3) MHD control and suppression, (4) edge dissipation control, radiation and plasma exhaust control and (5) break-down optimization. These categories are coupled via the physics (a control action in one domain will affect the other domains) and via shared actuators (e.g. ECRH for impurity accumulation avoidance, current density distribution control and MHD suppression). Consequently, a supervisory control system should determine the priority of the various control tasks, their couplings, and the interfaces with the safety and interlock system. For the systematic development of the various controllers taking the complexity of the plasma and the control system into account, a model-based approach is required. A short historical overview is given of the developments in systems and control theory and control engineering with special emphasis on those developments that are most relevant for Nuclear Fusion research and operation. An overview is given of the state of the field of fusion plasma control for the control categories. It will be shown how synthetic diagnostics are being developed in ITER and how they are used in diagnostic design and design validation and how they can be in model-based controller synthesis using relatively simple models. In modern control methods, multiple diagnostics are used to constrain relatively simple models. The constrained models provide an estimate for the state. This opens the route to state controllers, such as model predictive control. A major challenge in nuclear fusion research is the coherent combination of data from heterogeneous diagnostics and modeling codes for machine control and safety as well as physics studies. Measured data from different diagnostics often provide information about the same subset of physical parameters. Additionally, information provided by some diagnostics might be needed for the analysis of other diagnostics. A joint analysis of complementary and redundant data allows, e.g. to improve the reliability of parameter estimation, to increase the spatial and temporal resolution of profiles, to obtain synergistic effects, to consider diagnostics interdependencies and to find and resolve data inconsistencies. Physics-based modeling and parameter relationships provide additional information improving the treatment of ill-posed inversion problems. A coherent combination of all kind of available information within a probabilistic framework allows for improved data analysis results. The concept of integrated data analysis (IDA) in the framework of Bayesian probability theory is outlined and contrasted with conventional data analysis. Components of the probabilistic approach are summarized and specific ingredients beneficial for data analysis at fusion devices are discussed.

ITER↗

Understanding non-stochiometric deposition of multi-principal elemental NiCoCr thin films

Multi-principal elemental NiCoCr thin films with compositional flexibility have potential applications as a thermal barrier, corrosion-resistant coatings, and functional energy materials. In this study, the non-stochiometric multi-principal element alloy thin film formation behavior from an equiatomic ablation target of NiCoCr using pulsed laser deposition has been reported. Here, the effect of varying laser fluence on compositions of constituent elements in the NiCoCr thin films is systematically investigated. The increase in laser fluence typically increases the likelihood of acquiring undesirable particulates in thin films. Therefore, to maintain the film quality the laser fluences are adjusted within the range of 1.3–3.3 J·cm -2 , while the film thicknesses are kept constant at ~30 nm. Results show that the constituent elements are well-distributed in the formed NiCoCr thin films, however, having average atomic percentages of Ni and Cr twice as high as Co irrespective of the equiatomic composition of individual elements in the ablation target. This stochiometric alteration in the as-deposited thin films is governed by the rate of ablation and subsequent evaporation of each element, which is facilitated by the optical properties and vapor pressure of individual constituent elements. Additionally, electron energy-loss spectroscopy and x-ray absorption spectroscopy analysis reveal that the thin films have partially oxidized, with the Cr oxidation contributing the most to the O-K edge in comparison to Ni and Co. Finally, this study presents a laser-assisted pathway for fabricating compositionally flexible NiCoCr thin films and develops an understanding of the non-equilibrium laser-material interactions and how the intrinsic properties of constituent elements affect the stoichiometric flow of materials from the target to the final film deposition.

36 MATERIALS SCIENCE↗

Project AMIGA: A Minimal Covering Factor for Optically Thick Circumgalactic Gas around the Andromeda Galaxy

We present a deep search for H I 21 cm emission from the gaseous halo of Messier 31 as part of Project AMIGA, a large Hubble Space Telescope program to study the circumgalactic medium of the Andromeda galaxy. Our observations with the Robert C. Byrd Green Bank Telescope target sight lines to 48 background AGNs, more than half of which have been observed in the ultraviolet with the Cosmic Origins Spectrograph, with impact parameters 25≲ρ≲340 kpc (0.1≲ρ/R{sub vir}≲1.1). We do not detect any 21 cm emission toward these AGNs to limits of N(H I)≈4×10{sup 17} cm{sup −2} (5σ; per 2 kpc-diameter beam). This column density corresponds to an optical depth of ∼2.5 at the Lyman limit; thus, our observations overlap with absorption line studies of Lyman limit systems at higher redshift. Our non-detections place a limit on the covering factor of such optically thick gas around M31 to f{sub c}<0.051 (at 90% confidence) for ρ⩽R{sub vir}. Although individual clouds have previously been found in the region between M31 and M33, the covering factor of strongly optically thick gas is quite small. Our upper limits on the covering factor are consistent with expectations from recent cosmological “zoom” simulations. Recent COS-Halos ultraviolet measurements of H I absorption about an ensemble of galaxies at z≈0.2 show significantly higher covering factors within ρ≲0.5R{sub vir} at the same N(H I), although the metal ion-to-H I ratios appear to be consistent with those seen in M31.

79 ASTRONOMY AND ASTROPHYSICS↗

SU-E-J-142: Prompt Gamma Emission Measurements From a Passively Scattered Proton Beam On Targets Containing 16O, 12C and 14N

Purpose: To measure the prompt gamma emission from the important elements found in tissue ({sup 16}O,{sup 12}C and {sup 14}N) in a clinical passive-scatter treatment environment. Methods: The targets (composed of water, Perspex, graphite and liquid nitrogen) were irradiated with a 200 MeV passive-scatter proton beam and the discrete prompt gamma energy spectra was detected by a high resolution 2′ × 2′ LaBr. detector. In order to reduce the high level of radiation produced by the beam line elements, the detector was surrounded by 10 cm of lead to attenuate the scattered gamma-rays entering the detector with an extra 5 cm thick layer of lead added along the beam direction. A 10 cm thick collimator with a 5 cm × 10 cm rectangular opening was also used. Results: The prompt gamma peaks at 6.13 MeV and 4.44 MeV were clearly identified as a Result of the inelastic nuclear reaction between the protons and the 16O atoms found in the water target. The 6.13 MeV peak was 5% higher than the peak at 4.44 MeV for the water target. The 4.44 MeV peak was the only identified emission in the prompt gamma energy spectra from the graphite target ({sup 12}C). The expected 2.313 MeV peak form the{sup 14}N (liquid nitrogen target) was identified, but the other expected {sup 14}N peaks could not be resolved. Conclusion: Prompt gamma measurements with a passive-scatter proton beam are possible, but the presence of a high amount of background radiation from the patient final collimator presents a challenge at the treatment isocenter. The prominent prompt gamma peaks at 6.13 MeV and 4.44 MeV were identified from the water, Perspex and graphite targets. The prompt gammas from the liquid nitrogen target were difficult to see, but may not be significant in the in-vivo verification process.

60 APPLIED LIFE SCIENCES↗

EMD-57033 Augments the Contractility in Porcine Myocardium by Promoting the Activation of Myosin in Thick Filaments

Sufficient cardiac contractility is necessary to ensure the sufficient cardiac output to provide an adequate end-organ perfusion. Inadequate cardiac output and the diminished perfusion of vital organs from depressed myocardium contractility is a hallmark end-stage of heart failure. There are no available therapeutics that directly target contractile proteins to improve the myocardium contractility and reduce mortality. The purpose of this study is to present a proof of concept to aid in the development of muscle activators (myotropes) for augmenting the contractility in clinical heart failure. Here we use a combination of cardiomyocyte mechanics, the biochemical quantification of the ATP turnover, and small angle X-ray diffraction on a permeabilized porcine myocardium to study the mechanisms of EMD-57033 (EMD) for activating myosin. We show that EMD increases the contractility in a porcine myocardium at submaximal and systolic calcium concentrations. Biochemical assays show that EMD decreases the proportion of myosin heads in the energy sparing super-relaxed (SRX) state under relaxing conditions, which are less likely to interact with actin during contraction. Structural assays show that EMD moves the myosin heads in relaxed muscles from a structurally ordered state close to the thick filament backbone, to a disordered state closer to the actin filament, while simultaneously inducing structural changes in the troponin complex on the actin filament. The dual effects of EMD on activating myosin heads and the troponin complex provides a proof of concept for the use of small molecule muscle activators for augmenting the contractility in heart failure.

59 BASIC BIOLOGICAL SCIENCES↗