Search NASA⌕ Search

SEARCH · Search NASA

Results for “array detector”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,423 records · Page 79

SU-F-T-180: Evaluation of a Scintillating Screen Detector for Proton Beam QA and Acceptance Testing

Purpose: To test the performance of a commercial scintillating screen detector for acceptance testing and Quality Assurance of a proton pencil beam scanning system. Method: The detector (Lexitek DRD 400) has 40cm × 40cm field, uses a thin scintillator imaged onto a 16-bit scientific CCD with ∼0.5mm resolution. A grid target and LED illuminators are provided for spatial calibration and relative gain correction. The detector mounts to the nozzle with micron precision. Tools are provided for image processing and analysis of single or multiple Gaussian spots. Results: The bias and gain of the detector were studied to measure repeatability and accuracy. Gain measurements were taken with the LED illuminators to measure repeatability and variation of the lens-CCD pair as a function with f-stop. Overall system gain was measured with a passive scattering (broad) beam whose shape is calibrated with EDR film placed in front of the scintillator. To create a large uniform field, overlapping small fields were recorded with the detector translated laterally and stitched together to cover the full field. Due to the long exposures required to obtain multiple spills of the synchrotron and very high detector sensitivity, borated polyethylene shielding was added to reduce direct radiation events hitting the CCD. Measurements with a micro ion chamber were compared to the detector’s spot profile. Software was developed to process arrays of Gaussian spots and to correct for radiation events. Conclusion: The detector background has a fixed bias, a small component linear in time, and is easily corrected. The gain correction method was validated with 2% accuracy. The detector spot profile matches the micro ion chamber data over 4 orders of magnitude. The multiple spot analyses can be easily used with plan data for measuring pencil beam uniformity and for regular QA comparison.

60 APPLIED LIFE SCIENCES↗

The ultrafast pixel array camera system and its applications in high energy density physics

Diagnostics in high energy density physics, shock physics, and related fields are primarily driven by a need to record rapidly time-evolving signals in single-shot events. These measurements are often limited by channel count and signal degradation issues on cable links between the detector and digitizer. Here we present the Ultrafast Pixel Array Camera (UPAC), a compact and flexible detector readout system with 32 waveform-recording channels at up to 10 Gsample/s and 1.8 GHz analog bandwidth. The compact footprint allows the UPAC to be directly embedded in the detector environment. A key enabling technology is the PSEC4A chip, an eight-channel switch-capacitor array sampling device with up to 1056 samples/channel. The UPAC system includes a high-density input connector that can plug directly into an application-specific detector board, programmable control, and serial readout, with less than 5 W of power consumption in full operation. We present the UPAC design and characterization, including a measured timing resolution of ~20 ps or better on acquisitions of sub-nanosecond pulses with minimal system calibrations. Example applications of the UPAC are also shown to demonstrate operation of a solid-state streak camera, an ultrafast imaging array, and a neutron time-of-flight spectrometer.

47 OTHER INSTRUMENTATION↗

Results from the CUORE experiment

The Cryogenic Underground Observatory for Rare Events (CUORE) is the first bolometric experiment operated at about 10 mK reaching the ton-scale. CUORE main goal is the search for neutrinoless double beta decay in 130Te, while it is suitable also for other kinds of rare event searches, such as dark matter and axions. The detector is situated at Laboratori Nazionali del Gran Sasso (LNGS), Italy, and consists in an array of 988 TeO2 crystals, being both the detector and the source of the decay. Since the beginning of 2017, CUORE operations had both phases for physics data taking and campaigns of detector optimization to obtain the maximum from its potential. Here we briefly discuss one of the procedures for the optimization of the detector regarding noise reduction and report the achievements of CUORE concerning energy resolution and background in the region of interest after the first few months of data taking. Finally we conclude by examining the results from our first neutrinoless double beta decay analysis published at the beginning of 2018, which with a total TeO2 exposure of 86.3 kg·y allowed to place a lower limit on the decay half-life of T1/20ν(130Te) > 1.3 ×1025 yr (90% C.L.) .

Marini, L↗

Performance characterization of microtomography with complementary metal-oxide-semiconductor detectors for computer-aided defect inspection

We developed a computer-aided defect inspection system based on computed tomography (CT). The system consists of a homemade small cone-beam CT (CBCT) system and a graphical toolbox, which is used to extract a computer-aided design (CAD) model from the CT data. In the small CBCT system, the x-ray imaging detector is based on a complementary metal-oxide-semiconductor photodiode array in conjunction with a scintillator. Imaging performance of the detector was evaluated in terms of modulation-transfer function, noise-power spectrum, and detective quantum efficiency. The tomographic imaging performance of the small CBCT system was evaluated in terms of signal-to-noise ratio and contrast-to-noise ratio. The graphical toolbox to support defect inspection incorporates various functional tools such as volume rendering, segmentation, triangular-mesh data generation, and data reduction. All the tools have been integrated in a graphical-user interface form. The developed system can provide rapid visual inspection as well as quantitative evaluation of defects by comparing the extracted CAD file with the original file, if available, of an object. The performance of the developed system is demonstrated with experimental CT volume data.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Design of a Moderated Multidetector Neutron Spectrometer for Optimal Specificity

Neutron spectrometry can play an important role in the detection and identification of neutron-emitting sources in various security applications. In the present work, a portable filtered array neutron spectrometer, consisting of twelve 6LiF-based thermal neutron detectors embedded within a single heterogeneous volume was designed and its expected performance compared to that of a commercially available 12-sphere Bonner spheres spectrometer. Each detector within the volume was designed to optimally respond to a unique portion of the neutron spectrum by varying the type and thickness of materials used to filter the spectrum as well as the thickness of the moderator in front of the detector. The available design space was permuted and performance metrics developed to identify the optimal geometries. The top performing detector geometries were then combinatorially explored to identify the best array of geometries that yielded the most information about a neutron spectrum. The best performing filtered array was found to provide as much spectral information as, or more than, the commercially available 12-sphere Bonner spheres spectrometer to which it was compared.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Development of a low-power, low-cost front end electronics module for large scale distributed neutrino detectors

A number of concepts have been presented for distributed neutrino detectors formed of large numbers of autonomous detectors. Examples include the Antarctic Ross Ice Shelf Antenna Neutrino Array (ARIANNA) [Barwick 2006], as well as proposed radio extensions to the IceCube detector at South Pole Station such as AURA and IceRay. [Besson 2008]. We have focused on key enabling technical developments required by this class of experiments. The radio Cherenkov signal, generated by the Askaryan mechanism [Askaryan 1962, 1965], is impulsive and coherent up to above 1 GHz. In the frequency domain, the impulsive character of the emission results in simultaneous increase of the power detected in multiple frequency bands. This multiband triggering approach has proven fruitful, especially as anthropogenic interference often results from narrowband communications signals. A typical distributed experiment of this type consists of a station responsible for the readout of a cluster of antennas either near the surface of the ice or deployed in boreholes. Each antenna is instrumented with a broadband low-noise amplifier, followed by an array of filters to facilitate multi-band coincidence trigger schemes at the antenna level. The power in each band is detected at the output of each band filter, using either square-law diode detectors or log-power detectors developed for the cellular telephone market. The use of multiple antennas per station allows a local coincidence among antennas to be used as the next stage of the trigger. Station triggers can then be combined into an array trigger by comparing timestamps of triggers among stations and identifying space-time clusters of station triggers. Data from each station is buffered and can be requested from the individual stations when a multi-station coincidence occurs. This approach has been successfully used in distributed experiments such as the Pierre Auger Observatory. [Abraham et al. 2004] We identified the filters as being especially critical. The frequency range of interest, {approx}200 MHz to {approx}1.2 GHz, is a transitional region where the lumped circuit element approach taken at low frequencies begins to reach limitations due to component tolerances, component losses, and parasitic effects. Active circuits can help to mitigate against these effects at the cost of added power consumption that becomes prohibitive for distributed experiments across the band of interest. At higher frequency microstrip, stripline, and other microwave techniques come to the fore. We have developed designs and design tools for passive filters extending the high frequency techniques to the frequency range of interest. Microstrip and stripline techniques are not usually attractive here because of the large physical dimensions of the resulting circuits, but in this application the tradeoff of size against power consumption favors this choice. These techniques are also intrinsically low-cost, as the filter is built into the circuit boards and the cost of components and their assembly onto the board is avoided. The basic element of the filter tree is an impedance matched wideband diplexer. This consists of a pair of low pass and high pass filters with a shared cutoff frequency and complementary frequency responses. These are designing the lowpass filter as a high order LC filter, which can be implemented as a series of transmission line segments of varying width. This can be transformed in to a CL high pass filter with a complementary frequency response. When the two filters are coupled to a common input, the input impedances of the networks add in parallel to give a constant input impedance as a function of frequency, with power flowing into one leg or the other of the filter pair. These filters can be cascaded to divide the band into the frequency ranges of interest; the broadband impedance matching at the inputs makes coupling of successive stages straightforward. These circuits can be produced in quantity at low cost using standard PCB fabrication techniques. We have determined that to achieve best performance the circuits should be built on a low loss-tangent RF substrate. We are working in cooperation with our colleagues in condensed matter who also have a need for this capability to purchase the equipment for in-house fabrication of prototype quantities of these circuits. We plan to continue the work on these filtersusing internal funds, and produce and characterize the performance of prototypes. We also participated in deployment of a prototype detector station near McMurdo Station, Antarctica in collaboration with colleagues at UCLA and UC-Irvine. The prototype station includes a single-board computer, GPS receiver, ADC board, and Iridium satellite modem powered by an omnidirectional solar array. We operated this station in the austral summer of 2006-2007, and used the Iridium SMS mode to transmit the status of the station until the end of the daylight season.

47 OTHER INSTRUMENTATION↗

Neutron Transfer Reactions on Neutron-Rich N = 50 and N = 82 Nuclei Near the r-Process Path

Neutron transfer (d,p) reaction studies on the N = 50 isotones, {sup 82}Ge and {sup 84}Se, and A{approx_equal}130 nuclei, {sup 130,132}Sn and {sup 134}Te, have been measured. Direct neutron capture cross sections for {sup 82}Ge and {sup 84}Se (n,{gamma}) have been calculated and are combined with Hauser-Feshbach expectations to estimate total (n,{gamma}) cross sections. The A{approx_equal}130 studies used an early implementation of the ORRUBA array of position-sensitive silicon strip detectors for reaction proton measurements. Preliminary excitation energy and angular distribution results from the A{approx_equal}130 measurements are reported.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Evaluation, Refurbishment, and Characterization of Fast Neutron Scintillators for the TREAT Fuel Motion Monitoring System

This paper details work being performed at the Idaho National Laboratory (INL) to evaluate, refurbish, and characterize proton-recoil scintillation (PRS) detectors utilized in a 360 channel array for the measurement of fast neutrons in a standalone system historically called a hodoscope located in the Transient Reactor Test Facility (TREAT). The TREAT hodoscope serves as the primary Fuel Motion Monitoring System for documenting real time fuel displacement during transient experiments. The detectors in the hodoscope have stood dormant for over 20 years and significant degradation must be addressed before the system can be brought back to operational status. The refurbishment process begins by decoupling the PRS from their matched photo multiplier tubes (PMTs) and treating the PRS with ethanol. This process cleans the surfaces, removing paint and legacy labels/ markings. During this procedure many physical variations can be observed. After cleaning, the PRS are physically measured using a digital caliper and the dimensions documented. Following this, a well-controlled 280nm LED light source is used to stimulate the PRS to produce an emission spectrum inside an integration sphere. This emission spectrum is then measured using a UV enhanced optical spectrometer. Spectral measurements are recorded from 185 nm to 580 nm in 0.4 nm steps. The PRS are then lightly sanded on the non-PMT mating surfaces and painted with commercially available reflective paint. A final emission spectrum is recorded for each PRS after painting.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Polarimetric performance of a Laue lens gamma-ray CdZnTe focal plane prototype

A gamma-ray telescope mission concept [gamma ray imager (GRI)] based on Laue focusing techniques has been proposed in reply to the European Space Agency call for mission ideas within the framework of the next decade planning (Cosmic Vision 2015-2025). In order to optimize the design of a focal plane for this satellite mission, a CdZnTe detector prototype has been tested at the European Synchrotron Radiation Facility under an {approx}100% polarized gamma-ray beam. The spectroscopic, imaging, and timing performances were studied and in particular its potential as a polarimeter was evaluated. Polarization has been recognized as being a very important observational parameter in high energy astrophysics (>100 keV) and therefore this capability has been specifically included as part of the GRI mission proposal. The prototype detector tested was a 5 mm thick CdZnTe array with an 11x11 active pixel matrix (pixel area of 2.5x2.5 mm{sup 2}). The detector was irradiated by a monochromatic linearly polarized beam with a spot diameter of about 0.5 mm over the energy range between 150 and 750 keV. Polarimetric Q factors of 0.35 and double event relative detection efficiency of 20% were obtained. Further measurements were performed with a copper Laue monochromator crystal placed between the beam and the detector prototype. In this configuration we have demonstrated that a polarized beam does not change its polarization level and direction after undergoing a small angle (<1 deg.) Laue diffraction inside a crystal.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Cosmic ray spectrum from 250 TeV to 10 PeV using IceTop

We report here an extension of the measurement of the all-particle cosmic-ray spectrum with IceTop to lower energy. The new measurement gives full coverage of the knee region of the spectrum and reduces the gap in energy between previous IceTop and direct measurements. With a new trigger that selects events in closely spaced detectors in the center of the array, the IceTop energy threshold is lowered by almost an order of magnitude below its previous threshold of 2 PeV. In this paper, we explain how the new trigger is implemented, and we describe the new machine-learning method developed to deal with events with very few detectors hit. Here, we compare the results with previous measurements by IceTop and others that overlap at higher energy and with HAWC and Tibet in the 100 TeV range.

79 ASTRONOMY AND ASTROPHYSICS↗

SU-F-T-559: High-Resolution Scintillating Fiber Array for In-Vivo Real-Time SRS and SBRT Patient QA

Purpose: A high-resolution scintillating fiber detector was built for in-vivo real-time patient specific quality assurance (QA). The detector is designed for stereotactic body radiotherapy (SBRT) and stereotactic radiosurgery (SRS) to monitor treatment delivery and detect real-time deviations from planned dose to increase patient safety and treatment accuracy. Methods: The detector consists of two high-density scintillating fiber arrays layered to form an X-Y grid which can be attached to the accessory tray of a medical linac for SBRT and cone SRS treatment QA. Fiber arrays consist of 128 scintillating fibers embedded within a precision-machined, high-transmission polymer substrate with 0.8mm pitch. The fibers are coupled on both ends to high-sensitivity photodetectors and the output is recorded through a high-speed analog-to-digital converter to capture the linac pulse sequence as treatment delivery progresses. The detector has a software controlled 360 degree rotational system to capture angular beam projections for high-resolution beam profile reconstruction. Results: The detector was validated using SRS cone sizes from 6mm to 34mm and MLC defined field sizes from 5×5mm2 to 100×100mm2. The detector output response is linear with dose and is dose rate independent. Each field can be reconstructed accurately with a spatial resolution of 0.8mm and the current beam output is displayed every 50msec. Dosimetric errors of 1% with respect to the treatment plan can be identified and clinically significant deviations from the expected treatment can be displayed in real-time to alert the therapists. Conclusion: The high resolution detector is capable of reconstructing beam profiles in real-time with submillimeter resolution and 1% dose resolution. This system has the ability to project in-vivo both spatial and dosimetric errors during SBRT and SRS treatments when only a non-clinically significant fraction of the intended dose was delivered. The device has the potential to establish new standards for in-vivo patient specific QA.

60 APPLIED LIFE SCIENCES↗

Scintillation Properties of a Cs2LiLa(Br6)90%(Cl6)10%:Ce (CLLBC) Crystal

In investigations of Ce3+-doped Cs2LiLa(Br6)90%(Cl6)10% (CLLBC) elpasolite crystals, the crystals show an excellent neutron and gamma (n/g) radiation response. The results of our studies on the scintillation properties of CLLBC viz. radioluminescence, energy resolution, light yield, decay times, and nonproportionality are discussed. The CLLBC detector can provide energy resolution as good as 4.1% at 662 keV (FWHM), which is better than that of NaI:Tl. Because the crystal contains 6Li, CLLBC can also detect thermal neutrons. In the energy spectra, the full energy thermal neutron peak appears near or above 3 MeV gamma equivalent energy. This high-energy signature for the thermal neutron peak means that very effective pulse height discrimination is possible. Unfortunately, because the core-to-valence luminescence observed in other elpasolites that can be exploited for effective pulse shape discrimination (PSD) is not observed in the CLLBC, other strategies for obtaining the PSD of CLLBC are needed. The n/g discrimination capability of CLLBC detectors may be optimized by tuning the cerium doping content for maximum effect on n/g pulse shape differences. The value of adding a chlorine component to the nominal CLLB crystal is discussed. Because the crystal contains chlorine, its sensitivity to fast neutrons is better than that of Cs2LiLaBr6 (CLLB). Further, an array of three of these CLLBC detectors may be able to perform directional detection in both the neutron and gamma channels simultaneously.

36 MATERIALS SCIENCE↗

In-flight performance of the XRISM/Resolve detector system

The Resolve instrument was launched on board the XRISM observatory in early September 2023. The Resolve spectrometer is based on a high-sensitivity X-ray calorimeter detector system (DS) that has been successfully deployed in many ground and sub-orbital spectrometers. However, the Resolve instrument is the first long-term implementation in space. The instrument will provide essential diagnostics for nearly every class of X-ray emitting objects, from galactic supernova remnants to the outskirts of galaxy clusters, without degradation for spatially extended objects. The Resolve DS consists of a 36-pixel microcalorimeter array operated at a heat sink temperature of 50 mK. In pre-flight testing, the DS demonstrated a resolving power of better than 1300 at 6 keV with a simultaneous bandpass from below 0.3 keV to above 12 keV and a timing precision better than 100μs. An anti-coincidence detector placed directly behind the microcalorimeter array effectively suppresses background. The detector energy-resolution budget included terms for interference from the Resolve cooling system and the spacecraft. Additional terms for energy-scale stability, on-orbit effects, and use of mid-grade events were also included, predicting an end-of-life, on-orbit performance for high- and mid-resolution grade events that meet the requirement of 7 eV FWHM at 6 keV. Here, we discuss the actual on-orbit performance of the Resolve DS and compare this with the performance in pre-flight testing, on-orbit predictions, and the almost identical Hitomi/SXS instrument. We will also discuss the on-orbit gain stability, an assessment of on-orbit interference, and measurements of the on-orbit background.

Astronomy and AstroPhysics↗

The Cosmic Ray Observatory Project A Statewide Outreach Education Experiment in Nebraska

The Cosmic Ray Observatory Project (CROP) is a statewide education and research experiment involving Nebraska high school students, teachers, and college undergraduates in the study of extended cosmic-ray air showers. A network of high school teams construct, install, and operate school-based detectors in coordination with University of Nebraska physics professors and graduate students. The detector system at each school is an array of scintillation counters recycled from the Chicago Air Shower Array in weather-proof enclosures on the school roof, with a GPS receiver providing a time stamp for cosmic-ray events. The detectors are connected to triggering electronics and a data-acquisition PC inside the building. Students share data via the Internet to search for time coincidences with other sites. Funded by the U.S. National Science Foundation, CROP enlisted its first 11 schools in the summers of 2000 and 2001 with the aim of expanding to the 314 high schools in the state over the next several years. Similar school-based cosmic ray efforts in the U.S. and abroad will also be described.

43 PARTICLE ACCELERATORS↗

Spin Asymmetries on Nucleon Experiment at Jefferson Lab

The Spin Asymmetries of the Nucleon Experiment (SANE) of Jefferson Lab is a comprehensive measurement of double spin asymmetries of the proton for both parallel and almost perpendicular spin configurations of the proton spin and the electron beam polarization directions. The experiment will provide both spin structure functions, g{sub 2} and g{sub 1} and spin observable A{sub 2} and A{sub 1} of the proton over Q{sup 2} region from 2.5 to 6.5 GeV{sup 2}/c{sup 2} and Bjorken x region of 0.3 to 0.8. Using the polarized electron beam of Thomas Jefferson National Accelerator Facility and the polarized frozen NH{sub 3} target, the data were taken early 2009 in Hall C of Jefferson Lab. Scattered electrons from the inclusive reaction were detected by the Big Electron Telescope Array (BETA), a new non-magnetic detector with a large acceptance of 194 msr. The current analysis effort is focused on the proton spin structure functions g{sub 2} and g{sub 1}. Physics motivations with the experimental methods will be presented with an overview of the current status of the data analysis.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

A New Safeguards Technique for Spent Fuel Verification in Dry Storage by Using He-4 Detectors - 18262

It is demanded to find key issues and critical paths for verifying and monitoring a spent nuclear fuel cask or storage with a purpose of non-proliferation of nuclear weapon. However, unfortunately there are no reliable methods to verify the containment in a spent nuclear fuel cask or storage. Therefore, research and development (R and D) has been continuously required to develop new and alternative technologies for searching and verifying undeclared nuclear materials, activities, and facilities. Therefore, the present authors have developed a new safeguards technique of passively scanning a spent fuel cask or storage using pressurized He-4 scintillation neutron detectors. A new approach is to quickly verify content in a spent nuclear fuel cask or presence of all special nuclear materials in unknown packages by comparing experimental and computational results. For that, the present authors have developed a new algorithm and user-interface coupled ORIGEN-ARP and MCNP codes, and the prototype safeguards apparatus employing the array of He-4 fast neutron detectors has been designed, built, and tested. The feasibility test of this new apparatus has been performed with Cf-252 neutron sources and the laboratory scale model cask, minimized by a factor of ten compared to the actual dimension of a KN-21 cask. This technique has several advantages over current methods based on neutron and gamma detection; (1) incident neutron energy information is preserved, (2) disturbance of gamma-ray is excellently rejected (discriminated), and (3) much higher neutron counts and operational cost and space-effectiveness are expected since no moderator is required for fast neutrons. The final goal of this study will (1) conduct a prototype instrument and employ it to monitor a nuclear spent fuel cask or storage at a commercial nuclear power reactor facilities, (2) use spectral-specific measurement data to show proof of concept for measurable data successfully converted to quantifiable signatures, such as diversion/removal of fuel, and maintenance of fuel and cask integrity of fuel, and (3) develop a cask imaging capability. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Identification of Prompt Proton Emission in $N = Z - 1$ 61 Ga: Isospin Symmetry at the Limit of Nuclear Binding

Excited states in the proton drip line nucleus 61 Ga were populated via the fusion-evaporation reaction 24 Mg ⁢( 40 Ca, 𝑝⁢2⁢𝑛)⁢ 61 Ga. The experimental setup at Argonne National Laboratory comprised a novel combination of the Gammasphere array with two CD-shaped double-sided Si-strip detectors inside the Microball CsI(Tl) charged-particle detection array, as well as the Neutron-Shell liquid scintillators and the Fragment Mass Analyzer. Owing to the setup’s unprecedented in-beam proton spectroscopy and tracking capabilities, a coincidence between a 957.6(5)-keV 𝛾 ray and a 1.876(24)-MeV proton line was observed, which identifies the quasibound proton 𝜋⁢𝑔 9/2 single-particle state in 61 Ga at 𝐸 𝑥 = 2150⁢(34) keV. This probes isospin symmetry at the limit of nuclear binding by providing a unique challenge for the shell-model interpretation of mirror nuclei beyond doubly magic 56 Ni .

Hrabar, Yuliia [Lund Univ. (Sweden)] (ORCID:000000↗

CHERENCUBE: Concept definition and implementation challenges of a Cherenkov-based detector block for PET

Purpose: A new concept for a depth-of-interaction (DOI) capable time-of-flight (TOF) PET detector is defined, based only on the detection of Cherenkov photons. The proposed “CHERENCUBE” consists of a cubic Cherenkov radiator with position-sensitive photodetectors covering each crystal face. By means of the spatial distribution of the detected photons and their time of arrival, the point of interaction of the gamma-ray in the crystal can be determined. This study analyzes through theoretical calculations and Monte Carlo simulations the potential advantages of the concept toward reaching a Cherenkov-only detector for TOF-PET with DOI capability. Furthermore, an algorithm for the DOI estimation is presented and the requirements for a practical implementation of the proposed concept are defined. Methods: The Monte Carlo simulations consisted of a cubic crystal with one photodetector coupled to each one of the faces of the cube. The sensitive area of the detector matched exactly the crystal size, which was varied in 1 mm steps between 1 × 1 × 1 mm{sup 3} and 10 × 10 × 10 mm{sup 3}. For each size, five independent simulations of ten thousand 511 keV gamma-rays were triggered at a fixed distance of 10 mm. The crystal chosen was PbWO{sub 4}. Its scintillation properties were simulated, but only Cherenkov photons were analyzed. Photodetectors were simulated having perfect photodetection efficiency and infinite time resolution. For every generated particle, the analysis considered its creation process, parent and daughter particles, energy, origin coordinates, trajectory, and time and position of detection. The DOI determination is based on the distribution of the emission time of all photons per event. These values are calculated as a function of the coordinates of detection and origin for every photon. The common origin is estimated by finding the distribution with the most similar emission time-points. Results: Detection efficiency increases with crystal size from 8.2% (1 × 1 × 1 mm{sup 3}) to 58.6% (10 × 10 × 10 mm{sup 3}) and decreases applying a photon detection threshold of 5/10/20 photons to 6.3%/4.3%/0.7% and 49.3%/30.4%/2.8%, respectively. The detection rate in the six photodetectors is uniform due to the nearly isotropic cone emission. Most cones originated after a photoelectric effect interaction, with two dominating peaks for the kinetic energy of the electron at 422.99 and 441.47 keV. The detection distance between same-event photons defines the spatial resolution of the detector required for individual photon recognition, with 20% of the detected photons having their closest neighbor within a distance of 5% of the length of the cube. Same-event photons are detected within a time window whose width is determined by the crystal size, with values of 30 and 150 ps for a 1 × 1 × 1 mm{sup 3} and a 10 × 10 × 10 mm{sup 3} cube, respectively. The DOI reconstruction has an accuracy of approximately 23% of the length of the cube, with an average value of 2.2 mm for a 10 × 10 × 10 mm{sup 3} CHERENCUBE. Conclusions: The proposed concept requires a detector with high photodetection efficiency. The structure of the sensitive surface of the detector should be a two dimensional array of microcells, able to provide individual detection coordinates and time stamps. The microcell size determines the ability to recognize individual photons, influencing detection efficiency. The 3D DOI recognition relies on the accuracy of the time stamps and detection coordinates, without the need for a recognition of the projected patterns of photons. The refractive index of the material defines a detector intrinsic energy-based rejection of scattered PET events at the cost of reduced sensitivity.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗