Life test of 50 AH NiH2 battery
Life cycle testing on a battery is reported. The cells were built in 1975, put into battery in 1976, and flown in 1977 in low Earth orbit.
SEARCH · Search NASA
Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.
Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.
Life cycle testing on a battery is reported. The cells were built in 1975, put into battery in 1976, and flown in 1977 in low Earth orbit.
This report focuses on second-order digital phase-locked loops (DPLLs) with uniformly sampled input, an amplitude-insenstive phase extractor and a conventional loop filter.
January 26, 1987 marks the ninth inflight aniversary of the IUE spacecraft, launched into an eccentric synchronous orbit. The orbital path has subjected the spacecraft to 18 solar eclipse seasons since launch. Nine years of inflight operations culminate a major milestone for battery support to a spacecraft, which is well in excess of the initial 3 year design life. A brief outline of events, power system characteristics, and papers presented a previous battery workshops are provided. The IUE battery cell performance is excellent with the exception of the third electrode anomaly and temperature delta between batteries. Data indicates that battery depth-of-discharge (DOD) may be more critical to extend battery life than small operational temperature deltas between batteries. It is predicted that several additional years of battery life may be obtained by a reduction in operational battery DOD.
This paper summarizes the Hubble Space Telescope (HST) nickel-hydrogen (NiH2) battery performance from launch to the present time. Over the life of HST vehicle configuration, charge system degradation and failures together with thermal design limitations have had a significant effect on the capacity of the HST batteries. Changes made to the charge system configuration in order to protect against power system failures and to maintain battery thermal stability resulted in undercharging of the batteries. This undercharging resulted in decreased usable battery capacity as well as battery cell voltage/capacity divergence. This cell divergence was made evident during on-orbit battery capacity measurements by a relatively shallow slope of the discharge curve following the discharge knee. Early efforts to improve the battery performance have been successful. On-orbit capacity measurement data indicates increases in the usable battery capacity of all six batteries as well as improvements in the battery cell voltage/capacity divergence. Additional measures have been implemented to improve battery performance, however, failures within the HST Power Control Unit (PCU) have prevented verification of battery status. As this PCU fault prevents the execution of on-orbit capacity testing, the HST Project has based the battery capacity on trends, which utilizes previous on-orbit battery capacity test data, for science mission and servicing mission planning. The Servicing Mission 38 (SM-3B) in March 2002 replaced the faulty PCU. Following the servicing mission, on-orbit capacity test resumed. A summary of battery performance is reviewed since launch in this paper.
Three-day battery capable of operation at temperature of 425 degrees C for use on lunar and planetary probes
Several aspects of lithium primary cell technology are discussed with respect to aerospace application. Particular attention is given to the statistical analysis of battery data and accelerated testing.
The NASA Lewis Research Center has contracted with Electro Energy, Inc., to develop a bipolar nickel-metal hydride battery design for energy storage on low-Earth-orbit satellites. The objective of the bipolar nickel-metal hydride battery development program is to approach advanced battery development from a systems level while incorporating technology advances from the lightweight nickel electrode field, hydride development, and design developments from nickel-hydrogen systems. This will result in a low-volume, simplified, less-expensive battery system that is ideal for small spacecraft applications. The goals of the program are to develop a 1-kilowatt, 28-volt (V), bipolar nickel-metal hydride battery with a specific energy of 100 watt-hours per kilogram (W-hr/kg), an energy density of 250 W-hr/liter and a 5-year life in low Earth orbit at 40-percent depth-of-discharge.
Features of the first operational nickel hydrogen battery are described as well as experiences encountered during its testing and installation. Battery performance since launching of the NTS-2 satellite is discussed.
During FY 2025, the team at KSC focused on taking the 2024 proof-of-concept demonstration of hypergol production using novel methods and began scaling up production and increasing purity. The team was able to more than triple the production of hydrazine using a novel method with a drastic increase in the purity. The current method, albeit still limited to production rates on the order of mg/hr, provides a cost savings of approximately 14x when compared to market value pricing through the Defense Logistics Agency (DLA) website. The benefit of this technology is the ability to produce some hypergolic fuels using constituents in Earth’s atmosphere, eliminating most chemical commodity logistics. This technology also allows for the return of domestic production of hypergolic propellant.
Develop battery that will meet DS-2 power requirements under specified operational, environmental, and life requirements.
In 2013, the Boeing Company model 787-8 Dreamliner commercial aircraft experienced three catastrophic lithium (Li) battery failures. The cause of each failure resulted in a single-cell thermal runaway (TR) condition, which propagated to adjacent battery cells. Two of the failures involved rechargeable lithium-ion (Li-Ion) batteries, and the third event involved a nonrechargeable lithium-manganese dioxide (Li-MnO2) battery. In response to these Li battery failures, the NASA Engineering and Safety Center (NESC) approved a technical assessment of the International Space Station Simplified Aid for Extra-Vehicular Activity Rescue (SAFER) Li non-rechargeable battery. This assessment was conducted to evaluate the SAFER Li nonrechargeable battery safety design features against Boeing 787 Dreamliner Li battery failure lessons learned. Specifically, this investigation focused on assessing the severity of a SAFER battery TR hazard conditions.
Low temperature batteries for deep space probes and extending battery usefulness by heating
Filler and matrix composite materials for use in silver-zinc battery separators
The laser altimeter, consisting of a Q switched ruby laser, transmitting optics, counting timer, receiving optics, and a photomultiplier is described. Harmonic analysis of the mission data is also presented.
Protein crystal growth experiments have been performed by this laboratory on 18 Space Shuttle missions since April, 1985. In addition, a number of microgravity experiments also have been performed and reported by other investigators. These Space Shuttle missions have been used to grow crystals of a variety of proteins using vapor diffusion, liquid diffusion, and temperature-induced crystallization techniques. The United States Microgravity Laboratory - 1 mission (USML-1, June 25 - July 9, 1992) was a Spacelab mission dedicated to experiments involved in materials processing. New protein crystal growth hardware was developed to allow in orbit examination of initial crystal growth results, the knowledge from which was used on subsequent days to prepare new crystal growth experiments. In addition, new seeding hardware and techniques were tested as well as techniques that would prepare crystals for analysis by x-ray diffraction, a capability projected for the planned Space Station. Hardware that was specifically developed for the USML-1 mission will be discussed along with the experimental results from this mission.
Inorganic fillers and pressure effects on films for separators for heat sterilizable silver zinc battery
Viewgraphs of a discussion on bipolar rechargeable lithium battery for high power applications are presented. Topics covered include cell chemistry, electrolytes, reaction mechanisms, cycling behavior, cycle life, and cell assembly.
Primary zinc-silver oxide battery - separator material, construction, and prototype cell evaluation