Search NASA⌕ Search

SEARCH · Search NASA

Results for “certification”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,423 records · Page 79

Conceptual Design of a Tension Leg Platform With 22.3 MW Vertical Axis Turbine

Here, this paper presents the conceptual design of a tension leg platform (TLP) for the ARCUS “towerless” vertical-axis wind turbine (VAWT). VAWTs are ideal for floating offshore sites and have several advantages over horizontal-axis wind turbines (HAWT) including reduced top mass, lower center of gravity, increased energy capture, and in turn lower cost. The towerless ARCUS VAWT drives these advantages further through increased structural efficiency and by enabling more optimized TLP designs with simplified installation procedures. For hull sizing, we have studied three turbine sizes with corresponding power ratings of 5.1 MW, 10.4 MW and 22.3 MW. The largest turbine was identified as having the greatest potential to reduce the levelized cost of energy (LCOE) and is the reference size used for the further detailed design process. The conceptual design of the VAWT TLP has been awarded with an ABS Approval in Principle Certificate. This paper contains brief analysis results and design findings for a TLP designed to house a VAWT, including the following topics: • Applicable Design Codes • Metocean Conditions • ARCUS Turbine Loads • Design Load Cases and Requirements - Pre-service TLP Stability - In-place TLP Global Performance • Platform Configurations, Hull Structure Scantling Design, Weight and CG Estimation, and General Arrangement Drawings • Hull Ballast Plan for both Pre-service and In-place Conditions • Pre-service Quayside Integration, Transportation and Wet Tow Stability Analysis • Global Performance Analysis for Motions and Tendon tensions • Summary of cost components and system levelized cost of energy

17 WIND ENERGY↗

Package Impact Models as a Precursor to Cladding Analysis

The evaluation of spent nuclear fuel casks under impact loading is an important safety topic that is reviewed as part of cask certification by the United States Nuclear Regulatory Commission. Explicit dynamic finite element models of full cask systems are increasingly common in industry for determining structural integrity during hypothetical drop accidents. Full cask model results are also used as the loading basis for single fuel pin impact models, which evaluate the response of fuel cladding under drop conditions. In this paper, a simplified cask system is evaluated to illustrate several important structural dynamic phenomena, including the effect of gaps between components, the difference in local response at various points on a cask during impact, and the effect of modeling various simplified representations of the basket and fuel assemblies contained within the cask. This paper focuses on the cask impact analysis, and how loading conditions for a subsequent fuel assembly or fuel cladding analysis can be extracted.

Klymyshyn, Nicholas A.↗

FATIGUE BEHAVIOR OF SPENT NUCLEAR FUEL RODS IN SIMULATED TRANSPORTATION ENVIRONMENT

Nuclear fuel rod is composed of cladding tube and a specified number of fuel pellets contained. In the United States, spent nuclear fuel (SNF) is expected to be transported to at least one storage facility before permanent disposal. The fatigue behavior of spent nuclear fuel (SNF) rods under reversed cyclic bending must be understood in order to evaluate their vibration integrity in a transportation environment. This is especially important for high-burnup SNFs (>45 GWd/MTU). This report presents the experimental results related to Zircaloy (Zry)-4 - based surrogate rods and high-burnup SNFs, based on recent work performed at Oak Ridge National Laboratory (ORNL). The surrogate rod was made of Zry-4 cladding and alumina pellets, and high-burnup fuel rods were discharged from H.B. Robinson pressurized water reactor. The reversed cyclic bending testing was conducted at 5 Hz under loading control. The effect of pre-hydriding and burnup or irradiation on the flexural rigidity and fatigue life of cladding-pellet system were discussed. The fatigue data obtained are extremely useful to the future certification of SNF storage and transportation cask.

Wang, Jy-An John↗

Air kerma standard for calibration of well-type chambers in Brazil using {sup 192}Ir HDR sources and its traceability

In Brazil there are over 100 high dose rate (HDR) brachytherapy facilities using well-type chambers for the determination of the air kerma rate of {sup 192}Ir sources. This paper presents the methodology developed and extensively tested by the Laboratorio de Ciencias Radiologicas (LCR) and presently in use to calibrate those types of chambers. The system was initially used to calibrate six well-type chambers of brachytherapy services, and the maximum deviation of only 1.0% was observed between the calibration coefficients obtained and the ones in the calibration certificate provided by the UWADCL. In addition to its traceability to the Brazilian National Standards, the whole system was taken to University of Wisconsin Accredited Dosimetry Calibration Laboratory (UWADCL) for a direct comparison and the same formalism to calculate the air kerma was used. The comparison results between the two laboratories show an agreement of 0.9% for the calibration coefficients. Three Brazilian well-type chambers were calibrated at the UWADCL, and by LCR, in Brazil, using the developed system and a clinical HDR machine. The results of the calibration of three well chambers have shown an agreement better than 1.0%. Uncertainty analyses involving the measurements made both at the UWADCL and LCR laboratories are discussed.

61 RADIATION PROTECTION AND DOSIMETRY↗

Dependence with air density of the response of the PTW SourceCheck ionization chamber for low energy brachytherapy sources

Purpose: Air-communicating well ionization chambers are commonly used to assess air kerma strength of sources used in brachytherapy. The signal produced is supposed to be proportional to the air density within the chamber and, therefore, a density-independent air kerma strength is obtained when the measurement is corrected to standard atmospheric conditions using the usual temperature and pressure correction factor. Nevertheless, when assessing low energy sources, the ionization chambers may not fulfill that condition and a residual density dependence still remains after correction. In this work, the authors examined the behavior of the PTW 34051 SourceCheck ionization chamber when measuring the air kerma strength of {sup 125}I seeds.Methods: Four different SourceCheck chambers were analyzed. With each one of them, two series of measurements of the air kerma strength for {sup 125}I selectSeed{sup TM} brachytherapy sources were performed inside a pressure chamber and varying the pressure in a range from 747 to 1040 hPa (560 to 780 mm Hg). The temperature and relative humidity were kept basically constant. An analogous experiment was performed by taking measurements at different altitudes above sea level.Results: Contrary to other well-known ionization chambers, like the HDR1000 PLUS, in which the temperature-pressure correction factor overcorrects the measurements, in the SourceCheck ionization chamber they are undercorrected. At a typical atmospheric situation of 933 hPa (700 mm Hg) and 20 °C, this undercorrection turns out to be 1.5%. Corrected measurements show a residual linear dependence on the density and, as a consequence, an additional density dependent correction must be applied. The slope of this residual linear density dependence is different for each SourceCheck chamber investigated. The results obtained by taking measurements at different altitudes are compatible with those obtained with the pressure chamber.Conclusions: Variations of the altitude and changes in the weather conditions may produce significant density corrections, and that effect should be taken into account. This effect is chamber-dependent, indicating that a specific calibration is necessary for each particular chamber. To our knowledge, this correction has not been considered so far for SourceCheck ionization chambers, but its magnitude cannot be neglected in clinical practice. The atmospheric pressure and temperature at which the chamber was calibrated need to be taken into account, and they should be reported in the calibration certificate. In addition, each institution should analyze the particular response of its SourceCheck ionization chamber and compute the adequate correction factors. In the absence of a suitable pressure chamber, a possibility for this assessment is to take measurements at different altitudes, spanning a wide enough air density range.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

WE-D-18C-01: Art of Imaging: Diagnostic Ultrasound Image Artifacts

Assumptions followed during construction of B-mode and color flow images are that the pulse-echo transit time can be converted to reflector depth through uniform tissue models, echoes originate only from locations along the transmit-receive axes of pulse propagation, and first order correction schemes adequately account for acoustic wave attenuation and absorption. The latter allows the display brightness to encode tissue echogenicity. This course will challenge participants to identify imaging artifacts whose origins stem from the more complex and realistic propagating and scattering conditions common in clinical ultrasound. Speckle, a very common artifact but a clinically employed feature, originates from simultaneous echoes from diffuse scatterers and is a result of coherent detection of signals. One of the most bothersome artifacts are those due to reverberations especially that originating from superficial tissue interfaces. Methods to overcome these will be discussed. This presentation also will describe and illustrate speed of sound, refraction, enhancement, shadowing, mirroring, beam width, beam-forming, and slice thickness artifacts. All are useful examples of limitations introduced by acoustic waves propagating through complex tissue paths. New formats for physician board certification exams are demanding the inclusion of image-based examples of ultrasound physics. Instructors' knowledge of, and access to examples of ultrasound artifacts are important in this effort. The presentation will incorporate an audience response system to challenge participants in correct identification of some of these artifacts. Learning Objectives: Review basic mechanisms for producing ultrasound images. Identify the etiology of speckle, reverberation noise, beam width and slice thickness artifacts, and artifacts associated with pulse propagation. Discuss methods that reduce the impact of artifacts OR employ artifacts effectively to facilitate clinical diagnosis.

60 APPLIED LIFE SCIENCES↗

TU-D-201-03: Results of a Survey On the Implementation of the TG-51 Protocol and Associated Addendum On Reference Dosimetry of External Beams

Purpose: The working group on the review and extension of the TG-51 protocol (WGTG51) collected data from American Association of Physicists in Medicine (AAPM) members with respect to their current TG-51 and associated addendum usage in the interest of considering future protocol addenda and guidance on reference dosimetry best practices. This study reports an overview of this survey on dosimetry of external beams. Methods: Fourteen survey questions were developed by WGTG51 and released in November 2015. The questions collected information on reference dosimetry, beam quality specification, and ancillary calibration equipment. Results: Of the 190 submissions completed worldwide (U.S. 70%), 83% were AAPM members. Of the respondents, 33.5% implemented the TG-51 addendum, with the maximum calibration difference for any photon beam, with respect to the original TG-51 protocol, being <1% for 97.4% of responses. One major finding is that 81.8% of respondents used the same cylindrical ionization chamber for photon and electron dosimetry, implying that many clinics are foregoing the use of parallel-plate chambers. Other evidence suggests equivalent dosimetric results can be obtained with both cylindrical and parallel-plate chambers in electron beams. This, combined with users comfort with cylindrical chambers for electrons will likely impact recommendations put forward in an upcoming electron beam addendum to the TG-51 protocol. Data collected on ancillary equipment showed 58.2% (45.0%) of the thermometers (barometers) in use for beam calibration had NIST traceable calibration certificates, but 48.4% (42.7%) were never recalibrated. Conclusion: This survey provides a snapshot of TG-51 external beam reference dosimetry practice in radiotherapy centers. Findings demonstrate the rapid take-up of the TG-51 photon beam addendum and raise issues for the WGTG51 to focus on going forward, including guidelines on ancillary equipment and the choice of chamber for electron beam dosimetry.

61 RADIATION PROTECTION AND DOSIMETRY↗

Bringing Federated Identity to Grid Computing

The Fermi National Accelerator Laboratory (FNAL) is facing the challenge of providing scientific data access and grid submission to scientific collaborations that span the globe but are hosted at FNAL. Users in these collaborations are currently required to register as an FNAL user and obtain FNAL credentials to access grid resources to perform their scientific computations. These requirements burden researchers with managing additional authentication credentials, and put additional load on FNAL for managing user identities. Our design integrates the existing InCommon federated identity infrastructure, CILogon Basic CA, and MyProxy with the FNAL grid submission system to provide secure access for users from diverse experiments and collab orations without requiring each user to have authentication credentials from FNAL. The design automates the handling of certificates so users do not need to manage them manually. Although the initial implementation is for FNAL's grid submission system, the design and the core of the implementation are general and could be applied to other distributed computing systems.

Teheran, Jeny↗

Tensor Network Quantum Virtual Machine for Simulating Quantum Circuits at Exascale

The numerical simulation of quantum circuits is an indispensable tool for development, verification, and validation of hybrid quantum-classical algorithms intended for near-term quantum co-processors. The emergence of exascale high-performance computing (HPC) platforms presents new opportunities for pushing the boundaries of quantum circuit simulation. Here, we present a modernized version of the Tensor Network Quantum Virtual Machine (TNQVM) that serves as the quantum circuit simulation backend in the eXtreme-scale ACCelerator (XACC) framework. The new version is based on the scalable tensor network processing library ExaTN (Exascale Tensor Networks). It provides multiple configurable quantum circuit simulators that perform either an exact quantum circuit simulation via the full tensor network contraction or an approximate simulation via a suitably chosen tensor factorization scheme. Upon necessity, stochastic noise modeling from real quantum processors is incorporated into the simulations by modeling quantum channels with Kraus tensors. By combining the portable XACC quantum programming frontend and the scalable ExaTN numerical processing backend, we introduce an end-to-end virtual quantum development environment that can scale from laptops to future exascale platforms. We report initial benchmarks of our framework, which include a demonstration of the distributed execution, incorporation of quantum decoherence models, and simulation of the random quantum circuits used for the certification of quantum supremacy on Google’s Sycamore superconducting architecture.

Nguyen, Thien↗

Effects of Trigger Method on Fire Propagation during the Thermal Runaway Process in Li-ion Batteries

Lithium-ion batteries are prone to fire hazards due to the possibility of thermal runaway propagation. During battery product development and subsequent safety tests for design validation and safety certification, the thermal runaway onset is triggered by various test methods such as nail penetration, thermal ramp, or external short circuit. This failure initiation method affects the amount of heat contributions and the composition of gas generations. This study compares two such trigger methods, external heating and using a thermally-activated internal short circuit device (ISCD). The effects of the trigger method on total heat generation are experimentally investigated within 18650 cylindrical cells at single cell level as well as at multiple cell configuration level. The severity of failure was observed to be worse for cells with ISCDs at single cell level, whereas quite the opposite results were observed at multiple cell configuration level. A preliminary numerical analysis was performed to better understand the battery safety performance with respect to thermal runaway trigger methods and heat transfer conditions.

25 ENERGY STORAGE↗

PKPass

Password management solutions exist, but few are designed for enterprise systems administrators sharing oncall rotations. Due to the Multi-Factor Level of Assurance 4 effort, DOE is now distributing PIV cards with cryptographically signed certificate and private key pairs to administrators and other security-significant users. We utilize this public key infrastructure (PKI) to encrypt passwords for other recipients in a secure way. This is cross platform (works on OSX and Linux systems), and has already been adopted internally by the NCCS systems administration staff to replace their old password book system.

Adamson, RyanM.↗

ModuleOT

ModuleOT is an open hardware security platform which provides all features necessary for securing remote energy resources. The platform consists of a physical bump in-the wire device which runs a custom-built application built with Go and Python and leverages AES-NI Instruction set available on modern hardware for cryptographic acceleration. By combining these features, ModuleOT acts as an all-in-one low-cost solution to enable cryptographically secured communications to any critical remote servers or devices. Because the software application has been built using Golang, this source can be easily compiled for different hardware platforms. The module is designed to provide the following core features: (1) encrypted communications across an untrusted network, (2) certificate-based authentication with secure storage, (3) hardware cryptographic acceleration, (4) IP-based whitelisting, (5) local firewall management, and (6) legacy (RS485) device support.

Hasandka, Adarsh↗

SSH Proxy (sshproxy) v1.0

SSHProxy is a service that generates and manages ssh keys. This service can be used to allow a user to create an sshkey and then use that for a period of time defined by a configuration file. The service also supports custom "scopes" that can be used to allow longer lived keys under certain conditions. The service also supports using SSH certificates for signing the keys.

Canon, RichardShane↗

System Validation Platform Working Directories

A suite of software tools used to interface with power electronic equipment for laboratory testing and device certification. They are typically used as equipment drivers with using the System Validation Platform (SVP) graphical user interface (GUI). Sandia National Laboratories is a multimission laboratory managed and operated by National Technology & Engineering Solutions of Sandia, LLC, a wholly owned subsidiary of Honeywell International Inc., for the U.S. Department of Energy’s National Nuclear Security Administration under contract DE-NA0003525. SAND2021-1185 O

Johnson, JayT↗

certified

The missing certificate infrastructure for web APIs.

Rogers, DavidM [Oak Ridge National Laboratory (ORN↗

DER Translate

SAND2024-13723O This software translates and maps any .xlsx-based distributed energy resource (DER) device from the SunSpec certification registry (https://sunspec.org/certified-registry/) to a JSON-based DER models map. It is then read by DER monitoring tools for applications such as network intrusion detection and system health monitoring. Sandia National Laboratories is a multimission laboratory managed and operated by National Technology & Engineering Solutions of Sandia, LLC, a wholly owned subsidiary of Honeywell International Inc., for the U.S. Department of Energy’s National Nuclear Security Administration under contract DE-NA0003525.

Fragkos, Georgios↗

MasQiTT

SAND2025-03471O MasQiTT software is a proof-of-concept code that implements the Secure MQTT protocol. It demonstrates a publish/subscribe model of message passing within a network where the publishers can encrypt messages according to a topic and the subscribers can decrypt those messages. The example code shows an example of deployment of an end-to-end system that includes certificate authority and key management in addition to basic implementation of the protocol. Sandia National Laboratories is a multimission laboratory managed and operated by National Technology & Engineering Solutions of Sandia, LLC, a wholly owned subsidiary of Honeywell International Inc., for the U.S. Department of Energy’s National Nuclear Security Administration under contract DE-NA0003525.

Fisher, Andrew [Sandia National Lab. (SNL-CA), Liv↗

Impact of Tropical and Extratropical Cyclones on Future U.S. Offshore Wind Energy

Over 60 participants, including government officials, regulators, certification bodies, national laboratory researchers, academia, and industry representatives, gathered in person twice for a comprehensive discussion on the impacts of extreme weather on large-scale deployment of offshore wind energy for the U.S. The dialogue focused on addressing modeling challenges, the need for detailed observational data, refining risk assessment methodologies, and understanding the implications of climate change.

14 SOLAR ENERGY↗