Search NASA⌕ Search

SEARCH · Search NASA

Results for “image based modeling”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,423 records · Page 79

Improved time-delay lens modelling and H 0 inference with transient sources

ABSTRACT Strongly lensed explosive transients such as supernovae, gamma-ray bursts, fast radio bursts, and gravitational waves are very promising tools to determine the Hubble constant (H0) in the near future in addition to strongly lensed quasars. In this work, we show that the transient nature of the point source provides an advantage over quasars: The lensed host galaxy can be observed before or after the transient’s appearance. Therefore, the lens model can be derived from images free of contamination from bright point sources. We quantify this advantage by comparing the precision of a lens model obtained from the same lenses with and without point sources. Based on Hubble Space Telescope (HST) Wide Field Camera 3 (WFC3) observations with the same sets of lensing parameters, we simulate realistic mock data sets of 48 quasar lensing systems (i.e. adding AGN in the galaxy centre) and 48 galaxy–galaxy lensing systems (assuming the transient source is not visible but the time delay and image positions have been or will be measured). We then model the images and compare the inferences of the lens model parameters and H0. We find that the precision of the lens models (in terms of the deflector mass slope) is better by a factor of 4.1 for the sample without lensed point sources, resulting in an increase of H0 precision by a factor of 2.9. The opportunity to observe the lens systems without the transient point sources provides an additional advantage for time-delay cosmography over lensed quasars. It facilitates the determination of higher signal-to-noise stellar kinematics of the main deflector, and thus its mass density profile, which, in turn plays a key role in breaking the mass-sheet degeneracy and constraining H0.

Ding, Xuheng↗

RELICS: Strong Lens Models for Five Galaxy Clusters from the Reionization Lensing Cluster Survey

Strong gravitational lensing by galaxy clusters magnifies background galaxies, enhancing our ability to discover statistically significant samples of galaxies at ${\boldsymbol{z}}\gt 6$, in order to constrain the high-redshift galaxy luminosity functions. In this study, we present the first five lens models out of the Reionization Lensing Cluster Survey (RELICS) Hubble Treasury Program, based on new HST WFC3/IR and ACS imaging of the clusters RXC J0142.9+4438, Abell 2537, Abell 2163, RXC J2211.7–0349, and ACT-CLJ0102–49151. The derived lensing magnification is essential for estimating the intrinsic properties of high-redshift galaxy candidates, and properly accounting for the survey volume. We report on new spectroscopic redshifts of multiply imaged lensed galaxies behind these clusters, which are used as constraints, and detail our strategy to reduce systematic uncertainties due to lack of spectroscopic information. In addition, we quantify the uncertainty on the lensing magnification due to statistical and systematic errors related to the lens modeling process, and find that in all but one cluster, the magnification is constrained to better than 20% in at least 80% of the field of view, including statistical and systematic uncertainties. The five clusters presented in this paper span the range of masses and redshifts of the clusters in the RELICS program. We find that they exhibit similar strong lensing efficiencies to the clusters targeted by the Hubble Frontier Fields within the WFC3/IR field of view. Outputs of the lens models are made available to the community through the Mikulski Archive for Space Telescopes.

79 ASTRONOMY AND ASTROPHYSICS↗

WE-G-BRA-07: Analyzing the Safety Implications of a Brachytherapy Process Improvement Project Utilizing a Novel System-Theory-Based Hazard-Analysis Technique

Purpose: To investigate the hazards in cervical-cancer HDR brachytherapy using a novel hazard-analysis technique, System Theoretic Process Analysis (STPA). The applicability and benefit of STPA to the field of radiation oncology is demonstrated. Methods: We analyzed the tandem and ring HDR procedure through observations, discussions with physicists and physicians, and the use of a previously developed process map. Controllers and their respective control actions were identified and arranged into a hierarchical control model of the system, modeling the workflow from applicator insertion through initiating treatment delivery. We then used the STPA process to identify potentially unsafe control actions. Scenarios were then generated from the identified unsafe control actions and used to develop recommendations for system safety constraints. Results: 10 controllers were identified and included in the final model. From these controllers 32 potentially unsafe control actions were identified, leading to more than 120 potential accident scenarios, including both clinical errors (e.g., using outdated imaging studies for planning), and managerial-based incidents (e.g., unsafe equipment, budget, or staffing decisions). Constraints identified from those scenarios include common themes, such as the need for appropriate feedback to give the controllers an adequate mental model to maintain safe boundaries of operations. As an example, one finding was that the likelihood of the potential accident scenario of the applicator breaking during insertion might be reduced by establishing a feedback loop of equipment-usage metrics and equipment-failure reports to the management controller. Conclusion: The utility of STPA in analyzing system hazards in a clinical brachytherapy system was demonstrated. This technique, rooted in system theory, identified scenarios both technical/clinical and managerial in nature. These results suggest that STPA can be successfully used to analyze safety in brachytherapy and may prove to be an alternative to other hazard analysis techniques.

60 APPLIED LIFE SCIENCES↗

A framework to measure myocardial extracellular volume fraction using dual-phase low dose CT images

Purpose: Myocardial extracellular volume fraction (ECVF) is a surrogate imaging biomarker of diffuse myocardial fibrosis, a hallmark of pathologic ventricular remodeling. Low dose cardiac CT is emerging as a promising modality to detect diffuse interstitial myocardial fibrosis due to its fast acquisition and low radiation; however, the insufficient contrast in the low dose CT images poses great challenge to measure ECVF from the image. Methods: To deal with this difficulty, the authors present a complete ECVF measurement framework including a point-guided myocardial modeling, a deformable model-based myocardium segmentation, nonrigid registration of pre- and post-CT, and ECVF calculation. Results: The proposed method was evaluated on 20 patients by two observers. Compared to the manually delineated reference segmentations, the accuracy of our segmentation in terms of true positive volume fraction (TPVF), false positive volume fraction (FPVF), and average surface distance (ASD), were 92.18% ± 3.52%, 0.31% ± 0.10%, 0.69 ± 0.14 mm, respectively. The interobserver variability measured by concordance correlation coefficient regarding TPVF, FPVF, and ASD were 0.95, 0.90, 0.94, respectively, demonstrating excellent agreement. Bland-Altman method showed 95% limits of agreement between ECVF at CT and ECVF at MR. Conclusions: The proposed framework demonstrates its efficiency, accuracy, and noninvasiveness in ECVF measurement and dramatically advances the ECVF at cardiac CT toward its clinical use.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

X-ray observation of individual Ti-6Al-4V spherical powder particle impact in an in-situ operando laser directed energy deposition system

Understanding the particle capture mechanism in the laser directed energy deposition additive manufacturing process provides a foundation for improving productivity and reducing material loss. Capturing this phenomenon is challenging due to its highly transient time interval. To analyze the impact behavior of spherical Ti-6Al-4V powder, a custom laser directed energy deposition system was designed to control the deposition of individual particles. Synchrotron X-ray imaging at 24 kHz monitored the impact dynamics of individual powder particles. A multi-physics model based on the Smoothed-Particle Hydrodynamics scheme supported the analysis by providing the temperature and velocity fields of the molten pool. Results revealed that in laser directed energy deposition, surface tension forces dominated the powder–molten pool interaction. Hydrophobic Ti-6Al-4V powder particles had an equilibrium contact angle of 121 degrees with their molten state. Furthermore, Ti-6Al-4V powder particles required a high impact velocity (6 to 12 m/s) to transition from oscillation to submergence behavior. Lastly, oscillating powder particles that impacted near the location of the laser beam exhibited faster melting, highlighting the contribution of the laser beam to the melting mechanism. This work lays the foundation for investigations of powder particle impact in laser directed deposition and supports the validation of numerical models of powder–molten pool interactions.

36 MATERIALS SCIENCE↗

MAGNETIC FIELD TOPOLOGY AND THE THERMAL STRUCTURE OF THE CORONA OVER SOLAR ACTIVE REGIONS

Solar extreme ultraviolet (EUV) images of quiescent active-region coronae are characterized by ensembles of bright 1-2 MK loops that fan out from select locations. We investigate the conditions associated with the formation of these persistent, relatively cool, loop fans within and surrounding the otherwise 3-5 MK coronal environment by combining EUV observations of active regions made with TRACE with global source-surface potential-field models based on the full-sphere photospheric field from the assimilation of magnetograms that are obtained by the Michelson Doppler Imager (MDI) on SOHO. We find that in the selected active regions with largely potential-field configurations these fans are associated with (quasi-)separatrix layers (QSLs) within the strong-field regions of magnetic plage. Based on the empirical evidence, we argue that persistent active-region cool-loop fans are primarily related to the pronounced change in connectivity across a QSL to widely separated clusters of magnetic flux, and confirm earlier work that suggested that neither a change in loop length nor in base field strengths across such topological features are of prime importance to the formation of the cool-loop fans. We discuss the hypothesis that a change in the distribution of coronal heating with height may be involved in the phenomenon of relatively cool coronal loop fans in quiescent active regions.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Tumor-Volume Simulation During Radiotherapy for Head-and-Neck Cancer Using a Four-Level Cell Population Model

Purpose: To develop a fast computational radiobiologic model for quantitative analysis of tumor volume during fractionated radiotherapy. The tumor-volume model can be useful for optimizing image-guidance protocols and four-dimensional treatment simulations in proton therapy that is highly sensitive to physiologic changes. Methods: The analysis is performed using two approximations: (1) tumor volume is a linear function of total cell number and (2) tumor-cell population is separated into four subpopulations: oxygenated viable cells, oxygenated lethally damaged cells, hypoxic viable cells, and hypoxic lethally damaged cells. An exponential decay model is used for disintegration and removal of oxygenated lethally damaged cells from the tumor. Results: We tested our model on daily volumetric imaging data available for 14 head-and-neck cancer patients treated with an integrated computed tomography/linear accelerator system. A simulation based on the averaged values of radiobiologic parameters was able to describe eight cases during the entire treatment and four cases partially (50% of treatment time) with a maximum 20% error. The largest discrepancies between the model and clinical data were obtained for small tumors, which may be explained by larger errors in the manual tumor volume delineation procedure. Conclusions: Our results indicate that the change in gross tumor volume for head-and-neck cancer can be adequately described by a relatively simple radiobiologic model. In future research, we propose to study the variation of model parameters by fitting to clinical data for a cohort of patients with head-and-neck cancer and other tumors. The potential impact of other processes, like concurrent chemotherapy, on tumor volume should be evaluated.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Version 8 of the SMAP Level-4 Soil Moisture Data Assimilation Product

The NASA Soil Moisture Active Passive (SMAP) mission Level-4 Soil Moisture (L4_SM) product provides global, 9-km resolution, 3-hourly surface (0-5 cm) and root-zone (0-100 cm) soil moisture from April 2015 to present with a mean latency of 2.5 days from the time of observation. The product is based on the assimilation of SMAP L-band (1.4 GHz) brightness temperature (Tb) observations into the NASA Catchment land surface model as the model is driven with observations-based precipitation forcing. This presentation discusses the improvements in the forthcoming Version 8 of L4_SM, including updates in the precipitation forcing, the Catchment model parameters, and the L-band microwave radiative transfer model (mwRTM). The precipitation observations used in L4_SM Version 8 outside of North America and the high latitudes are from the latest (Version 7) NASA Integrated Multi-satellitE Retrievals for the Global Precipitation Measurement mission (IMERG) products. Moreover, occasionally excessive precipitation rates in earlier versions of L4_SM along certain longitudes in North America were eliminated by a bug fix in the precipitation corrections algorithm. The Catchment model in L4_SM Version 8 uses climatological snow albedo values based on observations from the Moderate Resolution Imaging Spectroradiometer, replacing the look-up table parameterization of earlier versions. Additionally, corrected soil parameters were implemented for a small region in Argentina that had erroneously been classified as peat because of an error in the ancillary soil data. Finally, the mwRTM in L4_SM Version 8 uses the Mironov soil mixing approach and updated values of the L-band scattering albedo, soil roughness, and vegetation opacity climatology obtained from the latest (Release 19) SMAP Level-2 dual-channel soil moisture retrieval product. During the development of L4_SM Version 8, the change in the mwRTM parameterization resulted in a reduced unbiased RMSE of surface soil moisture when verified against in situ measurements. It also reduced the standard deviation of the Tb observation-minus-forecast residuals by ~0.15 K, highlighting the importance of the mwRTM for successful data assimilation. The bug fixes in the precipitation corrections algorithm and the Catchment model soil parameters in the Argentina region result in locally large improvements of the simulated land surface states. In summary, the ongoing refinements of the L4_SM product continue to improve its science quality and performance for global soil moisture monitoring

Rolf Reichle↗

Coupling of Coastal Zone Color Scanner data to a physical-biological model of the southeastern U.S. continental shelf ecosystem. I - CZCS data description and Lagrangian particle tracing experiments. II - An Eulerian model. III - Nutrient and phytoplankton fluxes and CZCS data assimilation

Surface phytoplankton biomass of the southeastern U.S. continental shelf area is discussed based on coastal zone color scanner (CZCS) images obtained in April 1980. Data of chlorophyll distributions are analyzed in conjunction with concurrent flow and temperature fields. Lagrangian particle tracing experiments show that the particles move consistently with the evolution of the chlorophyll patterns. A four-component physical-biological model for a horizontal plane at a nominal depth of 17 m is presented. Model simulations using various physical-biological dynamics and boundary conditions show that the variability of chlorophyll distributions is controlled by horizontal advection. Phytoplankton and nutrient fluxes, calculated using the model, show considerable variability with time. The chlorophyll distributions obtained from the CZCS images are assimilated into the model to improve the phytoplankton flux estimates.

Ishizaka, Joji↗

On effective dose for radiotherapy based on doses to nontarget organs and tissues

Purpose: The National Council for Radiation Protection and Measurement (NCRP) published estimates for the collective population dose and the mean effective dose to the population of the United States from medical imaging procedures for 1980/1982 and for 2006. The earlier report ignored the effective dose from radiotherapy and the latter gave a cursory discussion of the topic but again did not include it in the population exposure for various reasons. This paper explains the methodology used to calculate the effective dose in due to radiotherapy procedures in the latter NCRP report and revises the values based on more detailed modeling. Methods: This study calculated the dose to nontarget organs from radiotherapy for reference populations using CT images and published peripheral dose data. Results: Using International Commission on Radiological Protection (ICRP) 60 weighting factors, the total effective dose to nontarget organs in radiotherapy patients is estimated as 298 ± 194 mSv per patient, while the U.S. population effective dose is 0.939 ± 0.610 mSv per person, with a collective dose of 283 000 ± 184 000 person Sv per year. Using ICRP 103 weighting factors, the effective dose is 281 ± 183 mSv per patient, 0.887 ± 0.577 mSv per person in the U.S., and 268 000 ± 174 000 person Sv per year. The uncertainty in the calculations is largely governed by variations in patient size, which was accounted for by considering a range of patient sizes and taking the average treatment site to nontarget organ distance. Conclusions: The methods used to estimate the effective doses from radiotherapy used in NCRP Report No. 160 have been explained and the values updated.

60 APPLIED LIFE SCIENCES↗

WE-E-18A-09: Application of a Channelized Hotelling Observer Model to Evaluate Angiographic Imaging Equipment

Purpose: To develop and apply an observer model to objectively evaluate and compare the performance of different angiographic imaging equipment and acquisition variables. Methods: Image Acquisition— Iodine-based phantoms were created with target diameters: 0.5, 1, 2, and 4 mm. The phantoms were imaged using both planes of a bi-plane angiography system with detector pixel dimensions 0.1542 mm{sup 2} and 0.1842 mm{sup 2}, respectively. All four phantoms were imaged with magnification factors 1.5, 1.25 and 1 and with the large and small focal spots. Phantom position and the dose per frame (0.12– 0.24 μ Gy/frame) were varied for a single phantom size, magnification and focal spot. Observer Model— For each experimental condition, 1200 signal-present and signal-absent images were acquired and a detectability index (d') was calculated with a Gabor-channelized Hotelling observer (CHO) model. Detectability indices were evaluated as a function of dose, phantom size, and magnification. The model was then applied to compare d' of the two imaging planes and focal spots. Uncertainty in d' was estimated by bootstrapping the data and by examining the shift-variance of systems. Results: Detectability indices varied linearly with magnification and the square root of dose. For the 2 and 4 mm phantoms, d' varied linearly with diameter. For the 0.5 and 1 mm phantoms, d' expectedly deviated from this linear relationship due to substantial detector and focal spot blurring of the phantoms. The small focal spot yielded up to 50% greater d' values than the large focal spot. For the two detectors, differences in d' did not exceed the estimated ∼7% error. Conclusions: The detectability indices predictably scaled with dose, diameter, magnification, and focal spot size and serve to validate the model. Results demonstrate statistically similar target detectability for both investigated detectors, despite differences in pixel dimensions. This CHO model provides a framework to evaluate angiographic system performance.

60 APPLIED LIFE SCIENCES↗

Deep Learning and Structural Imaging of Materials

Deep learning has had a transformative effect on numerous domains and is actively utilized by many scientists in data-intensive fields such as high-energy physics and cosmology. Materials science, and in particular, the structural imaging of materials with electrons and X-rays are projected to enter the age of scientific data torrents, positioning them as new application spaces for modern artificial intelligence. In this contribution, we provide a synopsis on the foundations and latest progress in deep learning and present an in-depth application of utilizing modern deep artificial neural networks in scanning transmission electron microscopy to extract structural material properties. We use this case study to expose the strengths of deep learning-based models and discuss their current limitations, in the process highlighting their potential use in other data-intensive structural imaging modalities.

Laanait, Nouamane↗

Mapping and monitoring changes in vegetation communities of Jasper Ridge, CA, using spectral fractions derived from AVIRIS images

An important application of remote sensing is to map and monitor changes over large areas of the land surface. This is particularly significant with the current interest in monitoring vegetation communities. Most of traditional methods for mapping different types of plant communities are based upon statistical classification techniques (i.e., parallel piped, nearest-neighbor, etc.) applied to uncalibrated multispectral data. Classes from these techniques are typically difficult to interpret (particularly to a field ecologist/botanist). Also, classes derived for one image can be very different from those derived from another image of the same area, making interpretation of observed temporal changes nearly impossible. More recently, neural networks have been applied to classification. Neural network classification, based upon spectral matching, is weak in dealing with spectral mixtures (a condition prevalent in images of natural surfaces). Another approach to mapping vegetation communities is based on spectral mixture analysis, which can provide a consistent framework for image interpretation. Roberts et al. (1990) mapped vegetation using the band residuals from a simple mixing model (the same spectral endmembers applied to all image pixels). Sabol et al. (1992b) and Roberts et al. (1992) used different methods to apply the most appropriate spectral endmembers to each image pixel, thereby allowing mapping of vegetation based upon the the different endmember spectra. In this paper, we describe a new approach to classification of vegetation communities based upon the spectra fractions derived from spectral mixture analysis. This approach was applied to three 1992 AVIRIS images of Jasper Ridge, California to observe seasonal changes in surface composition.

Sabol, Donald E., Jr.↗

The Development of a New Model of Solar EUV Irradiance Variability

The goal of this research project is the development of a new model of solar EUV (Extreme Ultraviolet) irradiance variability. The model is based on combining differential emission measure distributions derived from spatially and spectrally resolved observations of active regions, coronal holes, and the quiet Sun with full-disk solar images. An initial version of this model was developed with earlier funding from NASA. The new version of the model developed with this research grant will incorporate observations from SoHO as well as updated compilations of atomic data. These improvements will make the model calculations much more accurate.

Warren, Harry↗

Ephemerides of the major Neptunian satellites determined from earth-based astrometric and Voyager imaging observations

The Voyager project used Neptunian satellite ephemerides to support both navigation and acquisition of scientific data. The development of postencounter ephemerides for the satellites Triton, Nereid, and 1989N1 is discussed. Primary results are the final set of model parameters which generate orbits that best fit both the earth-based satellite observations and data acquired by Voyager. The ephemerides are compared with those generated preencounter, and the accuracy of the final ephemerides is assessed. Mean orbital elements are also provided as a geometrical representation for the satellite orbits.

Jacobson, R. A.↗

WE-E-17A-07: Patient-Specific Mathematical Neuro-Oncology: Biologically-Informed Radiation Therapy and Imaging Physics

Purpose: To demonstrate a method of generating patient-specific, biologically-guided radiation therapy (RT) plans and to quantify and predict response to RT in glioblastoma. We investigate the biological correlates and imaging physics driving T2-MRI based response to radiation therapy using an MRI simulator. Methods: We have integrated a patient-specific biomathematical model of glioblastoma proliferation, invasion and radiotherapy with a multiobjective evolutionary algorithm for intensity-modulated RT optimization to construct individualized, biologically-guided plans. Patient-individualized simulations of the standard-of-care and optimized plans are compared in terms of several biological metrics quantified on MRI. An extension of the PI model is used to investigate the role of angiogenesis and its correlates in glioma response to therapy with the Proliferation-Invasion-Hypoxia- Necrosis-Angiogenesis model (PIHNA). The PIHNA model is used with a brain tissue phantom to predict tumor-induced vasogenic edema, tumor and tissue density that is used in a multi-compartmental MRI signal equation for generation of simulated T2- weighted MRIs. Results: Applying a novel metric of treatment response (Days Gained) to the patient-individualized simulation results predicted that the optimized RT plans would have a significant impact on delaying tumor progression, with Days Gained increases from 21% to 105%. For the T2- MRI simulations, initial validation tests compared average simulated T2 values for white matter, tumor, and peripheral edema to values cited in the literature. Simulated results closely match the characteristic T2 value for each tissue. Conclusion: Patient-individualized simulations using the combination of a biomathematical model with an optimization algorithm for RT generated biologically-guided doses that decreased normal tissue dose and increased therapeutic ratio with the potential to improve survival outcomes for treatment of glioblastoma. Simulated T2-MRI is shown to be consistent with known physics of MRI and can be used to further investigate biological drivers of imaging-based response to RT.

60 APPLIED LIFE SCIENCES↗

Explainable artificial intelligence relates perovskite luminescence images to current-voltage metrics

As the demand for low-cost, high-efficiency solar energy technologies grows, metal halide perovskite (MHP) solar cells have emerged as a promising candidate for next-generation photovoltaics due to their high power conversion efficiencies. However, their poor durability and issues with manufacturing consistency remain significant barriers to commercialization. In this work, we develop deep learning models to support materials characterization and provide insight into features and processes influencing performance. The models are trained using transfer learning of a pretrained model to predict relevant current-voltage (IV) metrics based on different combinations of input electroluminescence (EL) and photoluminescence (PL) images of MHP devices. We examine which image types are most informative in accurately predicting different IV metrics. Additionally, we use explainable artificial intelligence (XAI) techniques to provide insights into specific spatial features in the devices that drive differences in performance. We find that stabilized luminescence images (e.g. those collected after biasing the devices for at least 1 min) are better for predicting metrics of open-circuit voltage (by PL) and short-circuit current (by PL with EL), but that predicting fill factor and overall power output may use the time-evolution of EL images. Based on attribution masks generated by integrated gradients for each device performance metric, we further suggest different loss mechanisms associated with categories of large and small spatial defects. Overall, this case study highlights the potential applicability of XAI methodology for streamlining MHP device analysis and accelerating detailed understanding of the relationships between spatial defects and impacts on performance.

14 SOLAR ENERGY↗

Temperature elevation by HIFU in ex vivo porcine muscle: MRI measurement and simulation study

Purpose: High-intensity focused ultrasound is a rapidly developing medical technology with a large number of potential clinical applications. Computational model can play a pivotal role in the planning and optimization of the treatment based on the patient's image. Nonlinear propagation effects can significantly affect the temperature elevation and should be taken into account. In order to investigate the importance of nonlinear propagation effects, nonlinear Westervelt equation was solved. Weak nonlinear propagation effects were studied. The purpose of this study was to investigate the correlation between the predicted and measured temperature elevations and lesion in a porcine muscle. Methods: The investigated single-element transducer has a focal length of 12 cm, an aperture of 8 cm, and frequency of 1.08 MHz. Porcine muscle was heated for 30 s by focused ultrasound transducer with an acoustic power in the range of 24–56 W. The theoretical model consists of nonlinear Westervelt equation with relaxation effects being taken into account and Pennes bioheat equation. Results: Excellent agreement between the measured and simulated temperature rises was found. For peak temperatures above 85–90 °C “preboiling” or cavitation activity appears and lesion distortion starts, causing small discrepancy between the measured and simulated temperature rises. From the measurements and simulations, it was shown that distortion of the lesion was caused by the “preboiling” activity. Conclusions: The present study demonstrated that for peak temperatures below 85–90 °C numerical simulation results are in excellent agreement with the experimental data in three dimensions. Both temperature rise and lesion size can be well predicted. Due to nonlinear effect the temperature in the focal region can be increased compared with the linear case. The current magnetic resonance imaging (MRI) resolution is not sufficient. Due to the inevitable averaging the measured temperature can be 10–30 °C lower than the peak temperature. Computational fluid dynamics can provide additional important information that is lost using a state of the art MRI device.

62 RADIOLOGY AND NUCLEAR MEDICINE↗