Search NASA⌕ Search

SEARCH · Search NASA

Results for “internal validity”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,423 records · Page 79

Sensitivity analysis of high resolution gamma-ray detection for safeguards monitoring at natural uranium conversion facilities

Under the policies proposed by recent International Atomic Energy Agency (IAEA) circulars and policy papers, implementation of safeguards exists when any purified aqueous uranium solution or uranium oxides suitable for isotopic enrichment or fuel fabrication exists. Under IAEA Policy Paper 18, the starting point for nuclear material under safeguards was reinterpreted, suggesting that purified uranium compounds should be subject to safeguards procedures no later than the first point in the conversion process. In response to this technical need, a combination of simulation models and experimental measurements were employed in previous work to develop and validate gamma-ray nondestructive assay monitoring systems in a natural uranium conversion plant (NUCP). In particular, uranyl nitrate (UO 2 (NO 3 ) 2 ) solution exiting solvent extraction was identified as a key measurement point (KMP). Passive nondestructive assay techniques using high resolution gamma-ray spectroscopy were evaluated to determine their viability as a technical means for drawing safeguards conclusions at NUCPs, and if the IAEA detection requirements of 1 significant quantity (SQ) can be met in a timely manner. Building upon the aforementioned previous validation work on detector sensitivity to varying concentrations of uranyl nitrate via a series of dilution measurements, this work investigates detector response parameter sensitivities to gamma-ray signatures of uranyl nitrate. The full energy peak efficiency of a detection system is dependent upon the sample, geometry, absorption, and intrinsic efficiency parameters. Perturbation of these parameters translates into corresponding variations of the 185.7 keV peak area of the 235 U in uranyl nitrate. Such perturbations in the assayed signature impact the quality or versatility of the safeguards conclusions drawn. Given the potentially high throughput of uranyl nitrate in NUCPs, the ability to assay 1 SQ of material requires uncertainty «1%. Accounting for material self-shielding properties, pipe thickness, and source-detector orientation is instrumental in determining the robustness of gamma-ray detection in the process monitoring of uranyl nitrate in NUCPs. Monte Carlo models and ray-tracing models were employed to determine the sensitivity of the detected 185.7 keV photon to self-shielding properties, pipe thickness, and source-detector geometry. Considering the implementation of the detection of 1 SQ, diversion of 1 SQ becomes essentially undetectable given the systematic uncertainty, in addition to considerations such as propagating uncertainties due to pipe offset/position, as well as minor variations in pipe thickness. Consequently, pipe thickness was the most sensitive variable in affecting full energy efficiency of the 185.7 keV signature peak with up to 8% variation in efficiency for ±0.5 mm changes in Schedule 40 304L stainless steel piping. Furthermore, computation of the attenuation correction factor of the uranyl nitrate solution [CF(AT) (i.e. εsample)] using Parker's method using with the approximation for the geometrical factor κ≈π/4 was validated through experimental, Monte Carlo and ray-tracing calculations for a uranyl nitrate filled transfer pipe segment. Furthermore, quantifying sensitivity in detector position, as well as voiding effects due to bubbly flow or laminar flow with an air gap in the uranyl nitrate becomes increasingly important as considerations from (static) design-scale measurements translate into (dynamic) field operations tests.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Establishing radiation therapy advanced practice in New Zealand

Introduction: Advanced practice (AP) is of increasing interest to many radiation therapists (RTs) both nationally and internationally. In New Zealand, initial research (2005–2008) showed strong support for the development of an AP role for medical radiation technologists (MRTs). Here, we report on a nationwide survey in which RTs validated and prioritised nine AP profiles for future development. Methods: All registered RTs in New Zealand (n = 260) were invited to take part in a survey in December 2011; 73 of whom returned a complete response. Results: RTs supported the implementation of AP roles in New Zealand and the requirement of a Master's degree qualification to underpin clinical knowledge. Most RTs endorsed the criteria attributed to each of the nine proposed AP profiles. The study identified that activities may qualify as either advanced practice or standard practice depending on the department. All participants agreed that an advanced practitioner should be a leader in the field, able to initiate and facilitate future developments within as well as outside this specific role. Acceptance of the AP roles by RTs and other health professionals as well as the availability of resources for successful implementation, were concerns expressed by some RTs. Conclusion: The authors recommend (1) the development of one scope of practice titled ‘advanced practitioner’ with generic and specialist criteria for each profile as the future career pathway, (2) promotion and support for the AP pathway by the New Zealand Institute of Medical Radiation Technology and the New Zealand Medical Radiation Technologists Board.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Three-dimensional nonlocal anisotropic elasticity: a generalized continuum theory of Ångström-mechanics

In this paper, based on Eringen’s theory of nonlocal anisotropic elasticity, the three-dimensional nonlocal anisotropic elasticity of generalized Helmholtz type is developed. The derivation of a new three-dimensional nonlocal anisotropic kernel, which is the Green function of the three-dimensional anisotropic Helmholtz equation, enables to capture anisotropic length scale effects by means of a length scale tensor, which is a symmetric tensor of rank two. The derived nonlocal kernel function possesses up to six internal characteristic lengths on the Ångström-scale. The presented theory of nonlocal elasticity possesses the appropriate property to be a generalized continuum theory of Ångström-mechanics, since the range of its validity and applicability is up to the Ångström-scale. The connection between the theory of nonlocal anisotropic elasticity and lattice theory is established. The tensor function of nonlocal elastic moduli as well as the nonlocal kernel function is given in terms of the Hessian matrix in the lattice approach. In the framework of the considered theory, the modeling of dislocations in anisotropic materials taking into consideration anisotropic dislocation core effects is presented. Important dislocation key formulas, namely the anisotropic Peach–Koehler stress formula, the Peach–Koehler force and the anisotropic Blin’s formula, are derived. A major tool used in deriving the expression of anisotropic Blin’s formula is Kirchner’s so-called FF-tensor, which is here generalized toward nonlocal anisotropic elasticity. The main feature and advantage of the derived fields, compared with the corresponding ones in classical anisotropic elasticity, is that they are free of singularities. Numerical applications to straight dislocations in bcc Fe are given, revealing the ability and advantage of the considered theory to describe adequately nonsingular anisotropic stress and self-energy fields capturing the effects of anisotropy on the Ångström-scale.

42 ENGINEERING↗

Interlaboratory Reproducibility of Contour Method Data in a High Strength Aluminum Alloy

The contour method for residual stress measurement has seen significant development, but an experimental reproducibility study utilizing physical samples has not been published. A double-blind reproducibly study is reported, having scope beginning with EDM cutting and ending with residual stress calculation. A reinforced I-beam sample geometry is identified for its unique residual stress profile when extracted from residual stress bearing quenched aluminum bar (7050-T74). Contour measurements are prescribed on a midplane of symmetry with dimensions 24.0 mm by 50.0 mm. Fourteen identically prepared samples are fabricated from a single long bar with well characterized and uniform residual stress. Five samples throughout the bar are identified for planning measurements to validate sample uniformity and overall suitability of the residual stress field. The planning measurements employ a range of techniques: contour method, neutron diffraction, and hole-drilling. Eight samples are distributed to an international group of participants to execute their standard measurement practice. A double-blind process is followed to provide anonymity. Results are provided by eight participants: six being self-similar and two being quite different, the latter set aside as outliers. An average residual stress field is established from non-outlying results and the spatial distribution of reproducibility standard deviation is determined. The average stress field ranges from -60 to 70 MPa and the reproducibility standard deviation averages 8.1 MPa on the measurement plane. The average reproducibility standard deviation is about 3 × larger for points within 1.0 mm of plane boundaries (17.6 MPa) than for the remaining points (6.1 MPa). Reproducibility standard deviation (among different labs) for contour method residual stress measurement is found to be very similar to repeatability standard deviation (in a single lab) reported in prior work. The reproducibility observed here, for the entire measurement process, is also similar to that found in a prior reproducibility study limited to contour method data analysis.

36 MATERIALS SCIENCE↗

Leveraging Structures in Fault Diagnosis for Lithium-Ion Battery Packs

Lithium-ion battery systems consist of a varying number of single cells, designed to meet specific application requirements for output voltage and capacity. Effective fault diagnosis in these battery systems is an essential prerequisite for ensuring their safe and reliable operation. To address this need, we introduce a novel model-based fault diagnosis approach that distinguishes itself by leveraging informative structures inherent in battery systems such as architecture, uniformity among the constituent cells, and sparsity of fault occurrences to enhance its fault diagnosis capabilities. The proposed approach formulates a moving horizon estimation (MHE) problem, incorporating such structural information to estimate different fault signals—specifically, internal short circuits, external short circuits, and voltage and current sensors faults. We conduct various simulations to evaluate the performance of the proposed approach under different fault types and magnitudes. The obtained results validate the proposed approach and promise effective fault diagnosis for battery systems.

Farakhor, Amir↗

Tractable Learning in Underexcited Power Grids

Estimating the structure of physical flow networks, such as power grids, is critical to secure delivery of energy. This article discusses statistical structure estimation in power grids in the “underexcited” regime, where a subset of internal nodes has zero injection fluctuations. Prior estimation algorithms based on nodal voltages fail for such grids as the voltage covariance matrix is not invertible. Here, we propose a novel topology learning algorithm for learning underexcited general networks. Our algorithm uses physics-informed conservation laws to first identify the zero-injection buses and their neighbors, and then estimates the remaining edges in the grid. We prove the asymptotic correctness of our algorithm for grids with nonadjacent internal zero-injection nodes. More important, we theoretically analyze our algorithm’s efficacy under noisy measurements, and determine bounds on maximum noise under which asymptotically correct recovery is guaranteed. Our approach is validated through simulations with voltage samples generated on test distribution grids with real injection data and nonlinear power flow models.

24 POWER TRANSMISSION AND DISTRIBUTION↗

A dual-Kinect approach to determine torso surface motion for respiratory motion correction in PET

Purpose: Respiratory gating is commonly used to reduce blurring effects and attenuation correction artifacts in positron emission tomography (PET). Established clinically available methods that employ body-attached hardware for acquiring respiration signals rely on the assumption that external surface motion and internal organ motion are well correlated. In this paper, the authors present a markerless method comprising two Microsoft Kinects for determining the motion on the whole torso surface and aim to demonstrate its validity and usefulness—including the potential to study the external/internal correlation and to provide useful information for more advanced correction approaches. Methods: The data of two Kinects are used to calculate 3D representations of a patient’s torso surface with high spatial coverage. Motion signals can be obtained for any position by tracking the mean distance to a virtual camera with a view perpendicular to the surrounding surface. The authors have conducted validation experiments including volunteers and a moving high-precision platform to verify the method’s suitability for providing meaningful data. In addition, the authors employed it during clinical {sup 18}F-FDG-PET scans and exemplarily analyzed the acquired data of ten cancer patients. External signals of abdominal and thoracic regions as well as data-driven signals were used for gating and compared with respect to detected displacement of present lesions. Additionally, the authors quantified signal similarities and time shifts by analyzing cross-correlation sequences. Results: The authors’ results suggest a Kinect depth resolution of approximately 1 mm at 75 cm distance. Accordingly, valid signals could be obtained for surface movements with small amplitudes in the range of only few millimeters. In this small sample of ten patients, the abdominal signals were better suited for gating the PET data than the thoracic signals and the correlation of data-driven signals was found to be stronger with abdominal signals than with thoracic signals (average Pearson correlation coefficients of 0.74 ± 0.17 and 0.45 ± 0.23, respectively). In all cases, except one, the abdominal respiratory motion preceded the thoracic motion—a maximum delay of approximately 600 ms was detected. Conclusions: The method provides motion information with sufficiently high spatial and temporal resolution. Thus, it enables meaningful analysis in the form of comparisons between amplitudes and phase shifts of signals from different regions. In combination with a large field-of-view, as given by combining the data of two Kinect cameras, it yields surface representations that might be useful in the context of motion correction and motion modeling.

60 APPLIED LIFE SCIENCES↗

SU-G-JeP2-08: Image-Guided Radiation Therapy Using Synthetic CTs in Brain Cancer

Purpose: Synthetic-CTs(synCTs) are essential for MR-only treatment planning. However, the performance of synCT for IGRT must be carefully assessed. This work evaluated the accuracy of synCT and synCT-generated DRRs and determined their performance for IGRT in brain cancer radiation therapy. Methods: MR-SIM and CT-SIM images were acquired of a novel anthropomorphic phantom and a cohort of 12 patients. SynCTs were generated by combining an ultra-short echo time (UTE) sequence with other MRI datasets using voxel-based weighted summation. For the phantom, DRRs from synCT and CT were compared via bounding box and landmark analysis. Planar (MV/KV) and volumetric (CBCT) IGRT performance were evaluated across several platforms. In patients, retrospective analysis was conducted to register CBCTs (n=34) to synCTs and CTs using automated rigid registration in the treatment planning system using whole brain and local registration techniques. A semi-automatic registration program was developed and validated to rigidly register planar MV/KV images (n=37) to synCT and CT DRRs. Registration reproducibility was assessed and margin differences were characterized using the van Herk formalism. Results: Bounding box and landmark analysis of phantom synCT DRRs were within 1mm of CT DRRs. Absolute 2D/2D registration shift differences ranged from 0.0–0.7mm for phantom DRRs on all treatment platforms and 0.0–0.4mm for volumetric registrations. For patient planar registrations, mean shift differences were 0.4±0.5mm (range: −0.6–1.6mm), 0.0±0.5mm, (range: −0.9–1.2mm), and 0.1±0.3mm (range: −0.7–0.6mm) for the superior-inferior(S-I), left-right(L–R), and anterior-posterior(A-P) axes, respectively. Mean shift differences in volumetric registrations were 0.6±0.4mm (range: −0.2–1.6mm), 0.2±0.4mm (range: −0.3–1.2mm), and 0.2±0.3mm (range: −0.2–1.2mm) for S-I, L–R, and A–P axes, respectively. CT-SIM and synCT derived margins were within 0.3mm. Conclusion: DRRs generated via synCT agreed well with CT-SIM. Planar and volumetric registrations to synCT-derived targets were comparable to CT. This validation is the next step toward clinical implementation of MR-only planning for the brain. The submitting institution has research agreements with Philips Healthcare. Research sponsored by a Henry Ford Health System Internal Mentored Grant.

60 APPLIED LIFE SCIENCES↗

GNS Castor V/21 Headspace Gas Sampling 2014

Prior to performing an internal visual inspection, samples of the headspace gas of the GNS Castor V/21 cask were taken on June 12, 2014. These samples were taken in support of the CREIPI/Japanese nuclear industry effort to validate fuel integrity without visual inspection by measuring the 85 Kr content of the cask headspace

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Multi-group Examination of Nickel-Reflected HEU System [Slides]

Researchers noted an unusually large bias for 8-in. nickel reflected HEU sphere in HMF-003 between the 252- group library and the CE library in SCALE 6.2.4. The bias was investigated by reviewing reactions that $k_{eff}$ is sensitive to using TSUNAMI and collecting reaction rate data using tools within SCALE. For this system, bias is primarily due to the elastic scattering in nickel. Researchers compared new multigroup structures in SCALE 6.3. For this system, reduction in CE-to-MG bias seen in the 302-group and further improved in the 1597-group structure. When researchers compared ENDF/B-VIII.0 in SCALE 6.3, library showed improved results with new nickel evaluation. However, the MG-to-CE bias can still be large as large biases can occur in any system. This example highlights the importance of validating results with measured systems.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Effects of Chlorine Capture and a Proposed Density Law on the Reactivity of Plutonium Solution Systems

During fissionable material processing, all normal and credible abnormal conditions must remain safely subcritical. Nuclear Criticality Safety (NCS) uses a number of methods to determine subcriticality, one of which is the use of neutron transport codes such as MCNP6. In order to create models for use with MCNP6, both the geometry and materials in fissionable material processes must be known, or assumptions must be made and quantified for the impact to bias. One of the systems with a significant amount of bias due to material modeling assumptions is in the area of aqueous plutonium processing. These solutions are typically plutonium nitrate solutions or plutonium chloride solutions, which are modeled as fictitious plutonium metal-water mixtures because little is known about the actual density of the solution and there is no current predictive capability approved for use at Los Alamos National Laboratory (LANL) for modeling them. This research is currently underway to fill the gap and develop an algorithm for use with MCNP6 to model the density of plutonium chloride solutions. The method is to be validated with experimental data for density, and also validated with critical experiments using MCNP6. Note that the Chlorine Worth Study (CWS) was performed in December 2021 to help bridge the gap in chlorine data for critical experiments, and is currently awaiting International Criticality Safety Benchmark Evaluation Project (ICSBEP) review. This study was performed by LANL at the National Criticality Experiments Research Center (NCERC) at the Nevada National Security Site (NNSS). Additional information regarding this experiment may currently be found in LA-UR- 22-29180. Additionally, the Chemistry-Actinide Analytical Chemistry (C-AAC) at LANL has performed a number of solution density measurements for PuCl 3 -HC 1 -H 2 O, allowing for such data be used to create a semi-empirical density via the Pitzer method. The published dataset for the measurements is documented in LA-UR-22-25454. This method has already been tested successfully for aqueous plutonium nitrate solutions in SCALE. Current solution density measurements exist of plutonium concentrations of 0-~142g/L, all at 2M HC1, at temperatures 20-40°C. Additional data was taken for HC1-corrected density values, which essentially mimics the data for a pure PuCl x -water solution. The calculations in this report aim to support the current research by demonstrating the difference in system reactivity for the current modeling method when compared to the new proposed modeling with a density law implementation, which is being written as a Python tool to be used with MCNP6.

38 RADIATION CHEMISTRY, RADIOCHEMISTRY, AND NUCLEA↗

MODIS Information, Data, and Control System (MIDACS) system specifications and conceptual design

The MODIS Information, Data, and Control System (MIDACS) Specifications and Conceptual Design Document discusses system level requirements, the overall operating environment in which requirements must be met, and a breakdown of MIDACS into component subsystems, which include the Instrument Support Terminal, the Instrument Control Center, the Team Member Computing Facility, the Central Data Handling Facility, and the Data Archive and Distribution System. The specifications include sizing estimates for the processing and storage capacities of each data system element, as well as traffic analyses of data flows between the elements internally, and also externally across the data system interfaces. The specifications for the data system, as well as for the individual planning and scheduling, control and monitoring, data acquisition and processing, calibration and validation, and data archive and distribution components, do not yet fully specify the data system in the complete manner needed to achieve the scientific objectives of the MODIS instruments and science teams. The teams have not yet been formed; however, it was possible to develop the specifications and conceptual design based on the present concept of EosDIS, the Level-1 and Level-2 Functional Requirements Documents, the Operations Concept, and through interviews and meetings with key members of the scientific community.

Han, D.↗

The extent of the unstable Monin-Obukhov layer for temperature and humidity above complex hilly grassland

An analysis is given of radiosonde measurements of the potential temperature, specific humidity, and wind profiles under unstable windy conditions during the First International Satellite Land Surface Climatology Project Field Experiment in Kansas. It is found that about 86 percent of the profiles have a height range over which the Monin-Obukhov (1954) similarity is valid. It is shown that the Businger-Dyer version of the similarity functions (Businger, 1988) is satisfactory for analyzing radiosonde profiles.

Brutsaert, Wilfried↗

Structural Design and Analysis of a Light-Weight Laminated Composite Heat Sink for Spaceflight PWBs

In order to reduce the overall weight in spaceborne electronic systems, a conventional metallic heat sink typically used for double-sided printed wiring boards was suggested to be replaced by light-weight and high-strength laminated composite materials. Through technology validation assurance (TVA) approach, it has been successfully demonstrated that using laminated composite heat sink can not only reduce the weight of the heat sink by nearly 50%, but also significantly lower the internal thermally-induced stresses that are largely responsible for potential delamination under cyclic temperature variations. With composite heat sink, both thermal and dynamic performance of the double-sided printed wiring board (PWB) exceeds that of its counterpart with metallic heat sink. Also included in this work is the original contribution to the understanding of creep behavior of the worst-case leadless chip carrier (LCC) surface mount solder joint. This was identified as the interconnection most susceptible to thermal fatigue damage in the PWB assembly.

Fan, Mark S.↗

Improved Hypersonic Inlet Performance Using Validated Strut Compression Designs

Aerojet is currently executing two Strutjet propulsion contracts: one a Rocket Based Combined Cycle (RBCC) engine for a NASA-Marshall Space Flight Center (MSFC) Advanced Reusable Transportation Technology (ARTT) program, the second a Dual Mode Ram/Scramjet engine for a USAF Wright Laboratories Storable Fuel Scramjet Flow Path Concepts program. The engines employed in both programs operate at supersonic and low hypersonic speeds and use inlets employing forebody external and sidewall compression. Aerojet has developed and validated a successful design methodology applicable to these inlet types. Design features include an integrated vehicle forebody, external side compression struts, strut sidewall and throat bleed, a throat shock trap, and variable geometry internal contraction. Computation Fluid Dynamic (CFD) predictions and test data show these inlets allow substantially increased flow turning angles over other designs. These increased flow turning angles allow shorter and lighter engines than current designs, which in turn enables higher performing vehicles with broad operating characteristics. This paper describes the designs of two different inlets evaluated by the NASA-MSFC and USAF programs, discusses the results of wind tunnel tests performed by NASA-Lewis Research Center, and provides correlations of test data with CFD predictions. Parameters of interest include low Mach number starting capability, start sensitivity as a function of back pressure at various contraction ratios, flow turning angles, strut and throat bleed effects, and pressure recovery at various Mach numbers.

Bulman, M. J.↗

Constructing Synoptic Maps of Stratospheric Column Ozone from HALOE, SAGE and Balloonsonde Data Using Potential Vorticity Isentropic Coordinate Transformations

In this study we utilize potential vorticity - isentropic (PVI) coordinate transformations as a means of combining ozone data from different sources to construct daily, synthetic three-dimensional ozone fields. This methodology has been used successfully to reconstruct ozone maps in particular regions from aircraft data over the period of the aircraft campaign. We expand this method to create high-resolution daily global maps of profile ozone data, particularly in the lower stratosphere, where high-resolution ozone data are sparse. Ozone climatologies in PVI-space are constructed from satellite-based SAGE II and UARS/HALOE data, both of which-use solar occultation techniques to make high vertical resolution ozone profile measurements, but with low spatial resolution. A climatology from ground-based balloonsonde data is also created. The climatologies are used to establish the relationship between ozone and dynamical variability, which is defined by the potential vorticity (in the form of equivalent latitude) and potential temperature fields. Once a PVI climatology has been created from data taken by one or more instruments, high-resolution daily profile ozone field estimates are constructed based solely on the PVI fields, which are available on a daily basis from NCEP analysis. These profile ozone maps could be used for a variety of applications, including use in conjunction with total ozone maps to create a daily tropospheric ozone product, as input to forecast models, or as a tool for validating independent ozone measurements when correlative data are not available. This technique is limited to regions where the ozone is a long-term tracer and the flow is adiabatic. We evaluate the internal consistency of the technique by transforming the ozone back to physical space and comparing to the original profiles. Biases in the long-term average of the differences are used to identify regions where the technique is consistently introducing errors. Initial results show the technique is useful in the lower stratosphere at most latitudes throughout the year,and in the winter hemisphere in the middle stratosphere. The results are problematic in the summer hemisphere middle stratosphere due to increased ozone photochemistry and weak PV gradients. Alternate techniques in these regions will be discussed. An additional limitation is the quality and resolution of the meteorological data.

Hollandsworth, Stacey M.↗

Effects of Command and Control Vehicle (C2V) operational environment on soldier health and performance

The purpose of this project was to use NASA technology to assist the US Army in the assessment of motion sickness incidences and effects on soldier performance and mood states within the Command and Control Vehicle (C2V). Specific objectives were (1) to determine if there was a significant difference between three internal configurations of the C2V and/or between seats within these vehicles; (2) to determine if there was a significant difference between the park, move, or short-halt field conditions; and (3) to validate a method of converging indicators developed by NASA to assess environmental impact of long duration spaceflight on crewmembers, using a large sample of subjects under ground-based operational conditions.

NASA Center ARC↗

Integration Testing of Space Flight Systems

This paper discusses the benefits of conducting multi-system integration testing of space flight elements in lieu of merely shipping and shooting to the launch site and launching. "Ship and shoot" is a philosophy that proposes to transport flight elements directly from the factory to the launch site and begin the mission without further testing. Integration testing, relevant to validation testing in this context, is a risk mitigation effort that builds upon the individual element and system levels of qualification and acceptance tests, greatly improving the confidence of operations in space. The International Space Station Program (ISSP) experience is the focus of most discussions from a historical perspective, while proposed integration testing of the Constellation Program is also discussed. The latter will include Multi-Element Integration Testing (MElT) and Flight Element Integration Testing (FElT).

Sowards, Stephanie↗