Search NASA⌕ Search

SEARCH · Search NASA

Results for “patterned beam”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,423 records · Page 79

Laser-induced graphene gas sensors for environmental monitoring

Artemesia tridentatais a foundational plant taxon in western North America and an important medicinal plant threatened by climate change. Low-cost fabrication of sensors is critical for developing large-area sensor networks for understanding and monitoring a range of environmental conditions. However, the availability of materials and manufacturing processes is still in the early stages, limiting the capacity to develop cost-effective sensors at a large scale. In this study, we demonstrate the fabrication of low-cost flexible sensors using laser-induced graphene (LIG); a graphitic material synthesized using a 450-nm wavelength bench top laser patterned onto polyimide substrates. We demonstrate the effect of the intensity and focus of the incident beam on the morphology and electrical properties of the synthesized material. Raman analyses of the synthesized LIG show a defect-rich graphene with a crystallite size in the tens of nanometers. This shows that the high level of disorder within the LIG structure, along with the porous nature of the material provide a good surface for gas adsorption. The initial characterization of the material has shown an analyte response represented by a change in resistance of up to 5% in the presence of volatile organic compounds (VOCs) that are emitted and detected byArtemisiaspecies. Bend testing up to 100 cycles provides evidence that these sensors will remain resilient when deployed across the landscapes to assess VOC signaling in plant communities. The versatile low-cost laser writing technique highlights the promise of low-cost and scalable fabrication of LIG sensors for gas sensor monitoring.

Chemistry↗

On-sky performance analysis of the vector apodizing phase plate coronagraph on MagAO/Clio2

We report on the performance of a vector apodizing phase plate coronagraph that operates over a wavelength range of 2–5 μm and is installed in MagAO/Clio2 at the 6.5 m Magellan Clay telescope at Las Campanas Observatory, Chile. The coronagraph manipulates the phase in the pupil to produce three beams yielding two coronagraphic point-spread functions (PSFs) and one faint leakage PSF. The phase pattern is imposed through the inherently achromatic geometric phase, enabled by liquid crystal technology and polarization techniques. The coronagraphic optic is manufactured using a direct-write technique for precise control of the liquid crystal pattern and multitwist retarders for achromatization. By integrating a linear phase ramp to the coronagraphic phase pattern, two separated coronagraphic PSFs are created with a single pupil-plane optic, which makes it robust and easy to install in existing telescopes. The two coronagraphic PSFs contain a 180° dark hole on each side of a star, and these complementary copies of the star are used to correct the seeing halo close to the star. To characterize the coronagraph, we collected a data set of a bright (m{sub L} = 0–1) nearby star with ∼1.5 hr of observing time. By rotating and optimally scaling one PSF and subtracting it from the other PSF, we see a contrast improvement by 1.46 magnitudes at 3.5 λ/D. With regular angular differential imaging at 3.9 μm, the MagAO vector apodizing phase plate coronagraph delivers a 5σ Δmag contrast of 8.3 (=10{sup −3.3}) at 2 λ/D and 12.2 (=10{sup −4.8}) at 3.5 λ/D.

79 ASTRONOMY AND ASTROPHYSICS↗

Optical retroreflector

Planar target material reflects incident optical energy back to source, such that retroreflected light intensity is function of angle of incidence only. Retroreflective pattern can be tailored to suit specific requirements such as alignment of distant surface normal to beam of laser light.

Weindling, F.↗

Optically-Tuned Far-Infrared Device

Spacing of visible interference pattern determines frequency of infrared radiation. Variable photoconductivity grating formed by interference of two visible laser beams intersecting on surface of proposed AlGaAs device substituted for fixed metal grating. Proposed device provides higher output-power density and greater tunability.

Katz, Joseph↗

Large Field-of-View KD*P Modulator for Solar Polarization Measurements

This paper will describe the evolution of the Marshall Space Flight Center electro-optical polarimeter with emphasis on the field of view characteristics of the its KD*P modulator. Understanding the field of view characteristics was essential to the success of the MSFC vector magnetograph. The paper will show how the field of view errors of KD*P look similar to the polarization patterns seen in simple sunspots and why the placement of the KD*P in a collimated beam was essential in separating the instrumental polarization from the solar signal. Finally, this paper will describe a modulator design which minimizes those field-of-view errors.

West, E. A.↗

Large Field-of-view KD*P Modulator for Solar Polarization Measurements

This paper will describe the evolution of the Marshall Space Flight Center electro-optical polarimeter with emphasis on the field of view characteristics of the its KD*P modulator. Understanding the field of view characteristics was essential to the success of the MSFC vector magnetograph. The paper will show how the field of view errors of KD*P look similar to the polarization patterns seen in simple sunspots and why the placement of the KD*P in a collimated beam was essential in separating the instrumental polarization from the solar signal. Finally, this paper will describe a modulator design which minimizes those field-of-view errors and will used in the new magnetograph development program at the University of Alabama, Huntsville.

West, Edward A.↗

NASA Tech Briefs, May 2008

Topics covered inclde: Deployable Wireless Camera Penetrators; Hand-Held Units for Short-Range Wireless Biotelemetry; Wearable Wireless Telemetry System for Implantable BioMEMS Sensors; Electronic Escape Trails for Firefighters; Architecture for a High-to-Medium-Voltage Power Converter; 24-Way Radial Power Combiner/Divider for 31 to 36 GHz; Three-Stage InP Submillimeter-Wave MMIC Amplifier; Fast Electromechanical Switches Based on Carbon Nanotubes; Solid-State High-Temperature Power Cells; Fast Offset Laser Phase-Locking System; Fabricating High-Resolution X-Ray Collimators; Embossed Teflon AF Laminate Membrane Microfluidic Diaphragm Valves; Flipperons for Improved Aerodynamic Performance; System Estimates Radius of Curvature of a Segmented Mirror; Refractory Ceramic Foams for Novel Applications; Self-Deploying Trusses Containing Shape-Memory Polymers; Fuel-Cell Electrolytes Based on Organosilica Hybrid Proton Conductors; Molecules for Fluorescence Detection of Specific Chemicals; Cell-Detection Technique for Automated Patch Clamping; Redesigned Human Metabolic Simulator; Compact, Highly Stable Ion Atomic Clock; LiGa(OTf)(sub 4) as an Electrolyte Salt for Li-Ion Cells; Compact Dielectric-Rod White-Light Delay Lines; Single-Mode WGM Resonators Fabricated by Diamond Turning; Mitigating Photon Jitter in Optical PPM Communication; MACOS Version 3.31; Fiber-Optic Determination of N2, O2, and Fuel Vapor in the Ullage of Liquid-Fuel Tanks; Spiking Neurons for Analysis of Patterns; Symmetric Phase-Only Filtering in Particle-Image Velocimetry; Efficient Coupler for a Bessel Beam Dispersive Element; and Attitude and Translation Control of a Solar Sail Vehicle.

Source record↗

The JWST/NIRCam Coronagraph: Mask Design and Fabrication

The NIRCam instrument on the James Webb Space Telescope will provide coronagraphic imaging from lambda =1-5 microns of high contrast sources such as extrasolar planets and circumstellar disks. A Lyot coronagraph with a variety of circular and wedge-shaped occulting masks and matching Lyot pupil stops will be implemented. The occulters approximate grayscale transmission profiles using halftone binary patterns comprising wavelength-sized metal dots on anti-reflection coated sapphire substrates. The mask patterns are being created in the Micro Devices Laboratory at the Jet Propulsion Laboratory using electron beam lithography. Samples of these occulters have been successfully evaluated in a coronagraphic testbed. In a separate process, the complex apertures that form the Lyot stops will be deposited onto optical wedges. The NIRCam coronagraph flight components are expected to be completed this year.

Coronagraph↗

The JWST/NIRCam Coronagraph Flight Occulters

The NIRCam instrument on the James Webb Space Telescope will have a Lyot coronagraph for high contrast imaging of extrasolar planets and circumstellar disks at lambda = 2 - 5 micrometers. Half-tone patterns are used to create graded-transmission image plane masks. These are generated using electron beam lithography and reactive ion etching of a metal layer on an antireflection coated sapphire substrate. We report here on the manufacture and evaluation of the flight occulters.

extrasolar planets↗

Methods and apparatus for transparent display using up-converting nanoparticles

Disclosed herein are transparent color displays with nanoparticles made with nonlinear materials and/or designed to exhibit optical resonances. These nanoparticles are embedded in or hosted on a transparent substrate, such as a flexible piece of clear plastic or acrylic. Illuminating the nanoparticles with invisible light (e.g., infrared or ultraviolet light) causes them to emit visible light. For example, a rare-earth doped nanoparticle may emit visible light when illuminated simultaneoulsy with a first infrared beam at a first wavelength .lamda..sub.1 and a second infrared beam at a second wavelength .lamda..sub.2. And a frequency-doubling nanoparticle may emit visible light when illuminated with a single infrared beam at the nanoparticle's resonant frequency. Selectively addressing these nanoparticles with appropiately selected pump beams yields visible light emitted from the nanoparticles hosted by the transparent substrate in a desired pattern.

36 MATERIALS SCIENCE↗

CORROSION RESISTANCE OF LASER-INTERFERENCE STRUCTURED ALUMINUM ALLOY 2024 COATED WITH MIL-PRF-85582 PRIMER

The use of aluminum alloys in aerospace industry requires more effective and reliable joining techniques. The lubricant contaminants from prior rolling operations affect surface energies and the quality of coating adhe-sion and adhesive bonded joints. In this study, a new laser-based technique is investigated as a surface treatment for coating applications. The laser interference power profile was created by splitting the beam and guiding both beams towards the specimen and overlapping them on the specimen surface, creating a line-interference pattern on the specimen surface. The laser-interference structuring (LIS) was used without any chemical treatments, such as those in chemical conversion coating (CCC) and sulfuric acid anodizing (SAA), which is a much simpler process than those chemical-based. To assess the effect of LIS on corrosion re-sistance of coating, Al 2024 panels prepared by LIS, CCC and SAA were coated with MIL-PRF-85582, Type I, Class N primer and exposed to salt spray environment according to ASTM B117. The exposure is currently in progress and the corrosion attack on the coated panels will be evaluated by the degree of blister formation and rust creepage.

Sabau, Adrian↗

Ka-Band Multibeam Aperture Phased Array Being Developed

Phased-array antenna systems offer many advantages to low-Earth-orbiting satellite systems. Their large scan angles and multibeam capabilities allow for vibration-free, rapid beam scanning and graceful degradation operation for high rate downlink of data to users on the ground. Technology advancements continue to reduce the power, weight, and cost of these systems to make phased arrays a competitive alternative in comparison to the gimbled reflector system commonly used in science missions. One effort to reduce the cost of phased arrays is the development of a Ka-band multibeam aperture (MBA) phased array by Boeing Corporation under a contract jointly by the NASA Glenn Research Center and the Office of Naval Research. The objective is to develop and demonstrate a space-qualifiable dual-beam Ka-band (26.5-GHz) phased-array antenna. The goals are to advance the state of the art in Ka-band active phased-array antennas and to develop and demonstrate multibeam transmission technology compatible with spacecraft in low Earth orbit to reduce the cost of future missions by retiring certain development risks. The frequency chosen is suitable for space-to-space and space-to-ground communication links. The phased-array antenna has a radiation pattern designed by combining a set of individual radiating elements, optimized with the type of radiating elements used, their positions in space, and the amplitude and phase of the currents feeding the elements. This arrangement produces a directional radiation pattern that is proportional to the number of individual radiating elements. The arrays of interest here can scan the main beam electronically with a computerized algorithm. The antenna is constructed using electronic components with no mechanical parts, and the steering is performed electronically, without any resulting vibration. The speed of the scanning is limited primarily by the control electronics. The radiation performance degrades gracefully if a portion of the elements fail. The arrays can be constructed to conform to a mounting surface, and multibeam capability is integral to the design. However, there are challenges for mission designers using monolithic-microwave-integrated-circuit- (MMIC-) based arrays because of reduced power efficiency, higher costs, and certain system effects that result in link degradations. The multibeam aperture phased-array antenna development is attempting to address some of these issues, particularly manufacturing, costs, and system performance.

Reinhart, Richard C.↗

High-resolution diffraction microscopy using the plane-wave field of a nearly diffraction limited focused x-ray beam

X-ray waves in the center of the beam waist of nearly diffraction limited focused x-ray beams can be considered to have amplitude and phase that are both almost uniform, i.e., they are x-ray plane waves. Here we report the results of an experimental demonstration of high-resolution diffraction microscopy using the x-ray plane wave of the synchrotron x-ray beam focused using Kirkpatrik-Baez mirrors. A silver nanocube with an edge length of {approx}100 nm is illuminated with the x-ray beam focused to a {approx}1 {mu}m spot at 12 keV. A high-contrast symmetric diffraction pattern of the nanocube is observed in the forward far field. An image of the nanocube is successfully reconstructed by an iterative phasing method and its half-period resolution is 3.0 nm. This method does not only dramatically improve the spatial resolution of x-ray microscopy but also is a key technology for realizing single-pulse diffractive imaging using x-ray free-electron lasers.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Cobalt-60 tomotherapy: Clinical treatment planning and phantom dose delivery studies

Purpose: Investigations have shown that a Cobalt-60 (Co-60) radioactive source has the potential to play a role in intensity modulated radiation therapy (IMRT). In this paper, Co-60 tomotherapy's conformal dose delivery potential is evaluated by delivering conformal dose plans on a cylindrical homogeneous phantom containing clinical structures similar to those found in a typical head and neck (H and N) cancer. Also, the clinical potential of Co-60 tomotherapy is investigated by generating 2D clinical treatment plans for H and N and prostate anatomical regions. These plans are compared with the 6 MV based treatment plans for modalities such as linear accelerator-based tomotherapy and broad beam IMRT, and 15 MV based 3D conformal radiation therapy (3DCRT).Methods: For experimental validation studies, clinical and nonclinical conformal dose patterns were delivered on circular, homogeneous phantoms containing GafChromic film. For clinical planning study, dose calculations were performed with the EGSnrc Monte Carlo program, where a Theratronics 780C Co-60 unit and a 6 MV linear accelerator were modeled with a MIMiC binary multileaf collimator. An inhouse inverse treatment planning system was used to optimize tomotherapy plans using the same optimization parameters for both Co-60 and 6 MV beams. The IMRT and 3DCRT plans for the clinical cases were generated entirely in the Eclipse treatment planning system based on inhouse IMRT and 3DCRT site specific protocols.Results: The doses delivered to the homogeneous phantoms agreed with the calculations, indicating that it is possible to deliver highly conformal doses with the Co-60 unit. The dose distributions for Co-60 tomotherapy clinical plans for both clinical cases were similar to those obtained with 6 MV based tomotherapy and IMRT, and much more conformal compared to 3DCRT plans. The dose area histograms showed that the Co-60 plans achieve the dose objectives for the targets and organs at risk.Conclusions: These results confirm that Co-60 tomotherapy is capable of providing state-of-the-art conformal dose delivery and could be used for the treatment of targets in both small and larger separation anatomical regions.

61 RADIATION PROTECTION AND DOSIMETRY↗

Integrated Strategies for Overcoming Resolution Limits in Electron Beam Lithography of Chemically Amplified Resists

Electron beam lithography (EBL) of chemically amplified resists (CARs) faces fundamental challenges, including stochastic electron scattering and acid diffusion, that limit resolution and reproducibility. Using SU-8 as a model CAR, this study systematically investigated complementary strategies to address these challenges, combining multipass exposure, proximity effect correction (PEC) with midrange correction factors, base quencher incorporation, and post-exposure bake (PEB) suppression. Monte Carlo simulations and calibrated PEC modeling revealed that extending the point spread function to include a midrange scattering component significantly improved critical dimension (CD) control across varying pattern densities, correcting deviations that conventional two-term PEC failed to capture. Multipass exposure, particularly 4-pass writing with a 25% offset, redistributed the dose to average stochastic beam and scattering fluctuations, reducing line-width roughness by more than 50% and yielding more uniform nanoscale features. Photoacid confinement was investigated by adding urea as a base quencher, which successfully reduced acid diffusion but introduced substantial sensitivity penalties without improving ultimate resolution or Z-factor performance, underscoring the trade-offs of chemical versus physical confinement. Suppressing PEB most directly minimized acid diffusion, resulting in improved Z-factors and reproducible 30 nm half-pitch dense line/space patterns. Overall, these results demonstrated that PEC with midrange correction, multipass strategies, quencher additives, and PEB-free processing addresses different aspects of the EBL process window and that their integration provides a comprehensive framework for managing stochastic scattering, diffusion, and chemical amplification effects. This framework advances dense nanoscale patterning in CARs and establishes guiding principles for optimizing resist design and process strategies in high-resolution EBL and potentially other advanced lithographies, such as extreme ultraviolet (EUV) lithography.

36 MATERIALS SCIENCE↗

Optimisation of the Search for CP-symmetry Violation at the Deep Underground Neutrino Experiment

The Deep Underground Neutrino Experiment (DUNE) is a next-generation long baseline experiment, which will be situated in South Dakota. Its detectors will utilise liquid-argon time projection chamber technology, which is able to capture neutrino interactions with an incredible spatial and calorimetric resolution. With what will become the world’s most intense neutrino beam, a highly capable near detector, and four (10kt fducial mass) far detector modules, DUNE will be able to achieve an ambitious physics programme. Most notably, DUNE will determine whether charge-parity symmetry is broken in neutrino oscillations - a finding that would have significant implications for the understanding of the matter-antimatter asymmetry in our Universe.This thesis presents the optimisation of a CP-violation analysis at DUNE using thePandora pattern-recognition software. The analysis assumes a 3.5 year exposure (1.36 × 1023 protons on target) to a neutrino and an antineutrino beam (7 year total). Only the predicted data of the far detector modules is used; near detector samples are not included. The initial sensitivity to CP-violation is found to be 3.8σ+0.9σ−1.1σ in an estimate that includes oscillation parameter uncertainties, systematic uncertainties and statistical fluctuations, and assumes a normal-ordering of the neutrino mass hierarchy. The performance of the Pandora event reconstruction is linked to that of the analysis, which is found to be limited by the reconstruction of the initial track-like region of electrons and photons. The ShowerRefinement algorithm is developed in response to this and its implementation into the analysis workflow results in an improved sensitivity to CP-violation of 4.6σ+0.9σ−1.0σ. With a perfected neutrino interaction vertex placement, this is further increased to 5.1σ+1.0σ−1.1σ.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

SU-F-T-181: Proton Therapy Tissue-Equivalence of 3D Printed Materials

Purpose: This work investigated the proton tissue-equivalence of various 3D printed materials. Methods: Three 3D printers were used to create 5 cm cubic phantoms made of different plastics with varying percentages of infill. White resin, polylactic acid (PLA), and NinjaFlex plastics were used. The infills ranged from 15% to 100%. Each phantom was scanned with a CT scanner to obtain the HU value. The relative linear stopping power (RLSP) was then determined using a multi-layer ion chamber in a 200 MeV proton beam. The RLSP was measured both parallel and perpendicular to the print direction for each material. Results: The HU values of the materials ranged from lung-equivalent (−820 HU σ160) when using a low infill, to soft-tissue-equivalent 159 (σ12). The RLSP of the materials depended on the orientation of the beam relative to the print direction. When the proton beam was parallel to the print direction, the RLSP was generally higher than the RLSP in the perpendicular orientation, by up to 45%. This difference was smaller (less than 6%) for the materials with 100% infill. For low infill cubes irradiated parallel to the print direction, the SOBP curve showed extreme degradation of the beam in the distal region. The materials with 15–25% infill had wide-ranging agreement with a clinical HU-RLSP conversion curve, with some measurements falling within 1% of the curve and others deviating up to 45%. The materials with 100% infill all fell within 7% of the curve. Conclusion: While some materials tested fall within 1% of a clinical HU-RLSP curve, caution should be taken when using 3D printed materials with proton therapy, as the orientation of the beam relative to the print direction can result in a large change in RLSP. Further investigation is needed to measure how the infill pattern affects the material RLSP. This work was supported by PHS grant CA180803.

60 APPLIED LIFE SCIENCES↗

SU-E-T-376: 3-D Commissioning for An Image-Guided Small Animal Micro- Irradiation Platform

Purpose: A 3-D radiochromic plastic dosimeter has been used to cross-test the isocentricity of a high resolution image-guided small animal microirradiation platform. In this platform, the mouse stage rotating for cone beam CT imaging is perpendicular to the gantry rotation for sub-millimeter radiation delivery. A 3-D dosimeter can be used to verify both imaging and irradiation coordinates. Methods: A 3-D dosimeter and optical CT scanner were used in this study. In the platform, both mouse stage and gantry can rotate 360° with rotation axis perpendicular to each other. Isocentricity and coincidence of mouse stage and gantry rotations were evaluated using star patterns. A 3-D dosimeter was placed on mouse stage with center at platform isocenter approximately. For CBCT isocentricity, with gantry moved to 90°, the mouse stage rotated horizontally while the x-ray was delivered to the dosimeter at certain angles. For irradiation isocentricity, the gantry rotated 360° to deliver beams to the dosimeter at certain angles for star patterns. The uncertainties and agreement of both CBCT and irradiation isocenters can be determined from the star patterns. Both procedures were repeated 3 times using 3 dosimeters to determine short-term reproducibility. Finally, dosimeters were scanned using optical CT scanner to obtain the results. Results: The gantry isocentricity is 0.9 ± 0.1 mm and mouse stage rotation isocentricity is about 0.91 ± 0.11 mm. Agreement between the measured isocenters of irradiation and imaging coordinates was determined. The short-term reproducibility test yielded 0.5 ± 0.1 mm between the imaging isocenter and the irradiation isocenter, with a maximum displacement of 0.7 ± 0.1 mm. Conclusion: The 3-D dosimeter can be very useful in precise verification of targeting for a small animal irradiation research. In addition, a single 3-D dosimeter can provide information in both geometric and dosimetric uncertainty, which is crucial for translational studies.

60 APPLIED LIFE SCIENCES↗