Search NASA⌕ Search

SEARCH · Search NASA

Results for “sampling methods”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,423 records · Page 79

Astrometry in local reference frames for deep space navigation

Future deep space missions will benefit from submilliarcsecond angular navigation accuracy (less than 25 km projected distance at Neptune). Conventional Very Long Baseline Interferometry (VLBI) measurement strategies entail observations of a radio source (RS) and spacecraft pair. To increase the 3-5 milliarcsecond accuracies currently attainable, instrumental improvements could be coupled with either of two methods: (1) use improved calibration measurements with the single RS as the spacecraft reference, or (2) use a reference frame established by a local network of RSs near the spacecraft to reduce the contribution of sky-dependent error sources. The demanding baseline vector (earth orientation) and tropospheric calibrations needed to realize submilliarcsecond accuracy with the single-source strategy would not be necessary with the multisource strategy. The two strategies are compared via a sample covariance analysis. In this analysis, the single-source method yields 1.5 milliarcseconds for the navigation accuracy, while the multisource method yields 0.5 milliarcseconds.

Treuhaft, R. N.↗

Soft-Bake Purification of SWCNTs Produced by Pulsed Laser Vaporization

The "soft-bake" method is a simple and reliable initial purification step first proposed by researchers at Rice University for single-walled carbon nanotubes (SWCNT) produced by high-pressure carbon mon oxide disproportionation (HiPco). Soft-baking consists of annealing as-produced (raw) SWCNT, at low temperatures in humid air, in order to degrade the heavy graphitic shells that surround metal particle impurities. Once these shells are cracked open by the expansion and slow oxidation of the metal particles, the metal impurities can be digested through treatment with hydrochloric acid. The soft-baking of SWCNT produced by pulsed-laser vaporization (PLV) is not straightforward, because the larger average SWCNT diameters (.1.4 nm) and heavier graphitic shells surrounding metal particles call for increased temperatures during soft-bake. A part of the technology development focused on optimizing the temperature so that effective cracking of the graphitic shells is balanced with maintaining a reasonable yield, which was a critical aspect of this study. Once the ideal temperature was determined, a number of samples of raw SWCNT were purified using the soft-bake method. An important benefit to this process is the reduced time and effort required for soft-bake versus the standard purification route for SWCNT. The total time spent purifying samples by soft-bake is one week per batch, which equates to a factor of three reduction in the time required for purification as compared to the standard acid purification method. Reduction of the number of steps also appears to be an important factor in improving reproducibility of yield and purity of SWCNT, as small deviations are likely to get amplified over the course of a complicated multi-step purification process.

Yowell, Leonard↗

Evidence for pigmentary hematite on Mars based on optical, magnetic, and Moessbauer studies of superparamagnetic (nanocrystalline) hematite

Samples containing variable amounts of superparamagnetic hematite (sp-Hm) were prepared by a method in which the sp-Hm particles were dispersed throughout larger particles of silica gel, and the optical and magnetic properties of these samples were compared with those of larger-diameter hematite (bulk-Hm). It is shown that the optical properties of sp-Hm are different from those of bulk-Hm. Implications of the results for mineralogical interpretations of spectral data for the Martian surface and its terrestrial analogues are discussed. It is concluded that features resulting from ferric iron in the Martian spectral data and the results of the Viking magnetic properties experiment are both consistent with hematite present as both sp-Hm and bulk-Hm; the hematite particles most likely occur in pigmentary form, i.e., as particles dispersed throughout the volume of a spectrally neutral material.

Morris, Richard V.↗

Application of Statistical Methods of Rain Rate Estimation to Data From The TRMM Precipitation Radar

The TRMM Precipitation Radar is well suited to statistical methods in that the measurements over any given region are sparsely sampled in time. Moreover, the instantaneous rain rate estimates are often of limited accuracy at high rain rates because of attenuation effects and at light rain rates because of receiver sensitivity. For the estimation of the time-averaged rain characteristics over an area both errors are relevant. By enlarging the space-time region over which the data are collected, the sampling error can be reduced. However. the bias and distortion of the estimated rain distribution generally will remain if estimates at the high and low rain rates are not corrected. In this paper we use the TRMM PR data to investigate the behavior of 2 statistical methods the purpose of which is to estimate the rain rate over large space-time domains. Examination of large-scale rain characteristics provides a useful starting point. The high correlation between the mean and standard deviation of rain rate implies that the conditional distribution of this quantity can be approximated by a one-parameter distribution. This property is used to explore the behavior of the area-time-integral (ATI) methods where fractional area above a threshold is related to the mean rain rate. In the usual application of the ATI method a correlation is established between these quantities. However, if a particular form of the rain rate distribution is assumed and if the ratio of the mean to standard deviation is known, then not only the mean but the full distribution can be extracted from a measurement of fractional area above a threshold. The second method is an extension of this idea where the distribution is estimated from data over a range of rain rates chosen in an intermediate range where the effects of attenuation and poor sensitivity can be neglected. The advantage of estimating the distribution itself rather than the mean value is that it yields the fraction of rain contributed by the light and heavy rain rates. This is useful in estimating the fraction of rainfall contributed by the rain rates that go undetected by the radar. The results at high rain rates provide a cross-check on the usual attenuation correction methods that are applied at the highest resolution of the instrument.

Meneghini, R.↗

Strategic Map for Exploring the Ocean-World Enceladus

Among the many "ocean worlds" of our solar system, Enceladus appears unique in its combination of astrobiologically relevant, exploration-worthy attributes: extensive liquid-water ocean with high-temperature hydrothermal activity, containing salts and organics expressed predictably into space. The Enceladus south polar plume allows direct access to telltale molecules, ions, isotopes, and potential cytofragments in space. Plume mass spectroscopy and sample return, in situ investigation of surface fallback deposits, direct vent exploration, and eventually oceanographic exploration can all be envisioned. However, building consensus to fund such ambitious exploration hinges on acquiring key new data. A roadmap is essential. It could start with cost-capped onramps: 1) flythrough analysis of the plume, following up on Cassini measurements with modern instruments; 2) sample return of plume material for analysis on Earth. A methodical mission sequence in which each step depends on emergent results from prior missions would push in situ oceanographic exploration into the second half of this century. Even for this scenario, prioritization by the next planetary Decadal Survey would be pivotal.

Cassini↗

Bulk Cutting of Carbon Nanotubes Using Electron Beam Irradiation

According to some embodiments, the present invention provides a method for attaining short carbon nanotubes utilizing electron beam irradiation, for example, of a carbon nanotube sample. The sample may be pretreated, for example by oxonation. The pretreatment may introduce defects to the sidewalls of the nanotubes. The method is shown to produces nanotubes with a distribution of lengths, with the majority of lengths shorter than 100 tun. Further, the median length of the nanotubes is between about 20 nm and about 100 nm.

Ziegler, Kirk J.↗

Detecting Faults By Use Of Hidden Markov Models

Frequency of false alarms reduced. Faults in complicated dynamic system (e.g., antenna-aiming system, telecommunication network, or human heart) detected automatically by method of automated, continuous monitoring. Obtains time-series data by sampling multiple sensor outputs at discrete intervals of t and processes data via algorithm determining whether system in normal or faulty state. Algorithm implements, among other things, hidden first-order temporal Markov model of states of system. Mathematical model of dynamics of system not needed. Present method is "prior" method mentioned in "Improved Hidden-Markov-Model Method of Detecting Faults" (NPO-18982).

Smyth, Padhraic J.↗

Contamination of Critical Surfaces from NVR Glove Residues Via Dry Handling and Solvent Cleaning

Gloves are often used to prevent the contamination of critical surfaces during handling. The type of glove chosen for use should be the glove that produces the least amount of non-volatile residue (NVR). This paper covers the analysis of polyethylene, nitrile, latex, vinyl, and polyurethane gloves using the contact transfer and gravimetric determination methods covered in the NASA GSFC work instruction Gravimetric Determination and Contact Transfer of Non-volatile Residue (NVR) in Cleanroom Glove Samples, 541-WI-5330.1.21 and in the ASTM Standard E-1731M-95, Standard Test Method for Gravimetric Determination of Non-Volatile Residue from Cleanroom Gloves. The tests performed focus on contamination of critical surfaces at the molecular level. The study found that for the most part, all of the gloves performed equally well in the contact transfer testing. However, the polyethylene gloves performed the best in the gravimetric determination testing, and therefore should be used whenever solvent contact is a possibility. The nitrile gloves may be used as a substitute for latex gloves when latex sensitivity is an issue. The use of vinyl gloves should be avoided, especially if solvent contact is a possibility. A glove database will be established by Goddard Space Flight Center (GSFC) Code 541 to compile the results from future testing of new gloves and different glove lots.

Sovinski, Marjorie F.↗

New free-wake analysis of rotorcraft hover performance using influence coefficients

Free-wake analyses of helicopter rotor wakes in hover using time stepping have been shown to encounter instabilities which preclude convergence to valid free-vortex solutions for rotor-wake geometries. Previous work has demonstrated that these convergence difficulties can be overcome by implementing a new free-wake analysis method based on the use of influence coefficients. The present paper reviews this approach and documents its incorporation into a hover performance analysis called Evaluation of Hover Performance using Influence Coefficients (EHPIC). The technical principles underlying the EHPIC code are described with emphasis on steps taken to develop the single-filament wake models used in previous work into a multifilament wake valid for realistic hover performance predictions. The coupling of the wake model to a lifting surface loads analysis is described, and sample problems are solved that illustrate the robustness of the method. Performance calculations are also undertaken for hover to illustrate the utility of EHPIC in the analysis of rotorcraft performance.

Quackenbush, Todd R.↗

Control of Convection in Containerless Processing

Many different containerless processing techniques are employed in materials research, with the common goals of eliminating chemical reactions with the crucible and reducing heterogeneous nucleation sites. Each containerless method has different driving forces for flow in a liquid sample, and each has different relations between the flow variables and the process parameters. Often more than one technique is required to achieve the objectives of an experimental program. For example, one project requires solidification experiments over a range of almost two orders of magnitude in flow velocity, in both laminar and turbulent flow, while another requires a particular combination of shear rate and cooling rate, leading to a different processing strategy. The results of a modeling effort to determine the best combination of methods to meet the requirements of these two different experimental programs are presented.

Hyers, R. W.↗

Comparison of Classical and Charge Storage Methods for Determining Conductivity of Thin Film Insulators

Conductivity of insulating materials is a key parameter to determine how accumulated charge will distribute across the spacecraft and how rapidly charge imbalance will dissipate. Classical ASTM and IEC methods to measure thin film insulator conductivity apply a constant voltage to two electrodes around the sample and measure the resulting current for tens of minutes. However, conductivity is more appropriately measured for spacecraft charging applications as the "decay" of charge deposited on the surface of an insulator. Charge decay methods expose one side of the insulator in vacuum to sequences of charged particles, light, and plasma, with a metal electrode attached to the other side of the insulator. Data are obtained by capacitive coupling to measure both the resulting voltage on the open surface and emission of electrons from the exposed surface, as well monitoring currents to the electrode. Instrumentation for both classical and charge storage decay methods has been developed and tested at Jet Propulsion Laboratory (JPL) and at Utah State University (USU). Details of the apparatus, test methods and data analysis are given here. The JPL charge storage decay chamber is a first-generation instrument, designed to make detailed measurements on only three to five samples at a time. Because samples must typically be tested for over a month, a second-generation high sample throughput charge storage decay chamber was developed at USU with the capability of testing up to 32 samples simultaneously. Details are provided about the instrumentation to measure surface charge and current; for charge deposition apparatus and control; the sample holders to properly isolate the mounted samples; the sample carousel to rotate samples into place; the control of the sample environment including sample vacuum, ambient gas, and sample temperature; and the computer control and data acquisition systems. Measurements are compared here for a number of thin film insulators using both methods at both facilities. We have found that conductivity determined from charge storage decay methods is 102 to 104 larger than values obtained from classical methods. Another Spacecraft Charging Conference presentation describes more extensive measurements made with these apparatus. This work is supported through funding from the NASA Space Environments and Effects Program and the USU Space Dynamics Laboratory Enabling Technologies Program.

Swaminathan, Prasanna↗

Correlation of the deply technique with the ultrasonic imaging of impact damage in graphite/epoxy composites

A quantitative ultrasonic technique for the nondestructive assessment of impact damage is described. The method, which involves digitizing the entire backscattered ultrasonic wave from a sample, was applied to two test panels removed from a 16-ply graphite/epoxy laminate and impacted with an aluminum ball fired at a velocity of 150 ft/sec. The results of the ultrasonic NDE were compared with the results obtained using the destructive deply technique of Freeman (1984). The NDE method provides through-the-thickness information on damage and only requires access to a single side of the material, while the deply technique gives exact information on the actual damage. Good quantitative agreement between the two techniques was obtained.

Smith, B. T.↗

Measuring Sulfur Isotope Ratios from Solid Samples with the Sample Analysis at Mars Instrument and the Effects of Dead Time Corrections

The Sample Analysis at Mars (SAM) instrument suite comprises the largest science payload on the Mars Science Laboratory (MSL) "Curiosity" rover. SAM will perform chemical and isotopic analysis of volatile compounds from atmospheric and solid samples to address questions pertaining to habitability and geochemical processes on Mars. Sulfur is a key element of interest in this regard, as sulfur compounds have been detected on the Martian surface by both in situ and remote sensing techniques. Their chemical and isotopic composition can belp constrain environmental conditions and mechanisms at the time of formation. A previous study examined the capability of the SAM quadrupole mass spectrometer (QMS) to determine sulfur isotope ratios of SO2 gas from a statistical perspective. Here we discuss the development of a method for determining sulfur isotope ratios with the QMS by sampling SO2 generated from heating of solid sulfate samples in SAM's pyrolysis oven. This analysis, which was performed with the SAM breadboard system, also required development of a novel treatment of the QMS dead time to accommodate the characteristics of an aging detector.

Franz, H. B.↗

Deep gamma ray penetration in thick shields

Appropriate importance function and sampling scheme facilitates the application of the Monte Carlo method to problems involving the deep penetration of radiation.

Armstrong, T. W.↗

Saturation magnetization of polycrystalline iron

The magnetic moment per gram, sigma (H sub I, T), where H sub I is the internal field and T is the temperature, was measured for a polycrystalline iron sphere with the vibrating-sample magnetometer. The instrument was calibrated by using a method utilizing the high permeability of an iron sphere. The spontaneous moment, sigma(0, T),was obtained from plots of sigma(H sub I, T) as a function of H sub I for temperatures from 4.2 K to room temperature. The value of the spontaneous moment, sigma(0, T), at 298.9 K was 217.5 + or -0.4 emu/g. The extrapolated moment, sigma(0, 0),at absolute zero from a plot of sigma(0, T) as a function of T to 3/2 power was 221.7 + or - 0.4 emu/g.

Behrendt, D. R.↗

Riding and handling qualities of light aircraft: A review and analysis

Design procedures and supporting data necessary for configuring light aircraft to obtain desired responses to pilot commands and gusts are presented. The procedures employ specializations of modern military and jet transport practice where these provide an improvement over earlier practice. General criteria for riding and handling qualities are discussed in terms of the airframe dynamics. Methods available in the literature for calculating the coefficients required for a linearized analysis of the airframe dynamics are reviewed in detail. The review also treats the relation of spin and stall to airframe geometry. Root locus analysis is used to indicate the sensitivity of airframe dynamics to variations in individual stability derivatives and to variations in geometric parameters. Computer programs are given for finding the frequencies, damping ratios, and time constants of all rigid body modes and for generating time histories of aircraft motions in response to control inputs. Appendices are included presenting the derivation of the linearized equations of motion; the stability derivatives; the transfer functions; approximate solutions for the frequency, damping ratio, and time constants; an indication of methods to be used when linear analysis is inadequate; sample calculations; and an explanation of the use of root locus diagrams and Bode plots.

Smetana, F. O.↗

Reliability testing and demonstration - Aerospace problems.

Several aerospace problems are solved using various reliability methods. The problems considered are associated with distribution functions, sampling, accelerated life testing, and accept/reject decisions with sequential testing. In addition, two reliability case histories are described in detail. They include the second space Electric Rocket Test (SERT II), and the Microthruster Power Conditioner (MTPC) life test, both conducted by the Lewis Research Center.

Lalli, V. R.↗

Design and testing a high fuel volume fraction, externally finned, thermionic emitter.

A prototypical, high fuel volume fraction, thermionic emitter body was designed and tested. The emitter body is all tungsten, with a 1.40-cm ID, a 3.23-cm OD, and eight full-length axial fins. The emitter thickness is 0.15 cm while the fins and outer clad are 0.075 cm thick. Different methods of fabrication were used in making the test samples. Stress analysis was performed with a three-dimensional elastic code. Thermal testing of the samples, duplicating calculated radial temperature gradients, heatup and cooldown rates, and emitter body temperatures in operation, was performed with no structural failures noted (six heatup and cooldown cycles per sample). Further emitter analysis and testing is planned.

Peelgren, M. L.↗