Search NASA⌕ Search

SEARCH · Search NASA

Results for “spatial performance”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,423 records · Page 79

Experimental observation of the plasma potential with the screening temperature

An experimental investigation of the Boltzmann relation in the plasma bulk region and the presheath region was performed at low pressure inductively coupled plasma with bi-Maxwellian distribution. The spatial profiles of the electron energy distribution function (EEDF) were measured from the discharge center to the plasma boundary with an ion mean free path scale. The screening temperature was derived from the Einstein relation and the bi-Maxwellian EEDFs, and it has the same expression as the electron temperature in the ion directed velocity to the sheath edge in plasmas with the bi-Maxwellian EEDFs. Radial variations of the ambipolar potential and the presheath potential were calculated with the screening temperature and compared with the obtained value from the spatially measured EEDFs. It was shown that the ambipolar potential and the presheath potential are governed by the screening temperature.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Potential description of the charmonium from lattice QCD

We present spin-independent and spin-spin interquark potentials for charmonium states, that are calculated using a relativistic heavy quark action for charm quarks on the PACS-CS gauge configurations generated with the Iwasaki gauge action and 2+1 flavors of Wilson clover quark. The interquark potential with finite quark masses is defined through the equal-time Bethe-Salpeter amplitude. The light and strange quark masses are close to the physical point where the pion mass corresponds to M{sub π} ≈ 156(7) MeV, and charm quark mass is tuned to reproduce the experimental values of η{sub c} and J/ψ states. Our simulations are performed with a lattice cutoff of a{sup −1} ≈ 2.2 GeV and a spatial volume of (3 fm){sup 3}. We solve the nonrelativistic Schrödinger equation with resulting charmonium potentials as theoretical inputs. The resultant charmonium spectrum below the open charm threshold shows a fairly good agreement with experimental data of well-established charmonium states.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Response of alpha particles in hexagonal boron nitride neutron detectors

Here, thermal neutron detectors were fabricated from 10 B enriched h-BN epilayers of different thicknesses. The charge carrier generation and energy loss mechanisms as well as the range of alpha daughter particles generated by the nuclear reaction between thermal neutrons and 10 B atoms in hexagonal boron nitride (h-BN) thermal neutron detectors have been investigated via their responses to alpha particles from a 210 Po source. The ranges of alpha particles in h-BN were found to be anisotropic, which increase with the angle (θ) between the trajectory of the alpha particles and c-axis of the h-BN epilayer following (cos θ) -1 and are 4.6 and 5.6 μm, respectively, for the alpha particles with energies of 1.47 MeV and 1.78 MeV at θ = 0. However, the energy loss of an alpha particle inside h-BN is determined by the number of layers it passes through with a constant energy loss rate of 107 eV per layer due to the layered structure of h-BN. Roughly 5 electron-hole pairs are generated when an alpha particle passes through each layer. It was also shown that the durability of h-BN thermal neutron detectors is excellent based on the calculation of boron vacancies generated (or 10 B atoms consumed) by neutron absorption. Finally, the results obtained here provide useful insights into the mechanisms of energy loss and charge carrier generation inside h-BN detectors and possible approaches to further improve the overall performance of h-BN thermal neutron detectors, as well as the ultimate spatial resolution of future neutron imaging devices or cameras based on h-BN epilayers.

47 OTHER INSTRUMENTATION↗

Photoinduced non-adiabatic energy transfer pathways in dendrimer building blocks

The efficiency of the intramolecular energy transfer in light harvesting dendrimers is determined by their well-defined architecture with high degree of order. After photoexcitation, through-space and through-bond energy transfer mechanisms can take place, involving vectorial exciton migration among different chromophores within dendrimer highly branched structures. Their inherent intramolecular energy gradient depends on how the multiple chromophoric units have been assembled, subject to their inter-connects, spatial distances, and orientations. Herein, we compare the photoinduced nonadiabatic molecular dynamics simulations performed on a set of different combinations of a chain of linked dendrimer building blocks composed of two-, three-, and four-ring linear polyphenylene chromophoric units. The calculations are performed with the recently developed ab initio multiple cloning-time dependent diabatic basis implementation of the Multiconfigurational Ehrenfest (MCE) approach. Despite differences in short time relaxation pathways and different initial exciton localization, at longer time scales, electronic relaxation rates and exciton final redistributions are very similar for all combinations. Unlike the systems composed of two building blocks, considered previously, for the larger 3 block systems here we observe that bifurcation of the wave function accounted by cloning is important. In all the systems considered in this work, at the time scale of few hundreds of femtoseconds, cloning enhances the electronic energy relaxation by ~13% compared to that of the MCE method without cloning. Thus, accurate description of quantum effects is essential for understanding of the energy exchange in dendrimers both at short and long time scales.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Absolute calibration of GafChromic film for very high flux laser driven ion beams

We report on the calibration of GafChromic HD-v2 radiochromic film in the extremely high dose regime up to 100 kGy together with very high dose rates up to 7 × 10 11 Gy/s. The absolute calibration was done with nanosecond ion bunches at the Neutralized Drift Compression Experiment II particle accelerator at Lawrence Berkeley National Laboratory (LBNL) and covers a broad dose dynamic range over three orders of magnitude. We then applied the resulting calibration curve to calibrate a laser driven ion experiment performed on the BELLA petawatt laser facility at LBNL. Here, we reconstructed the spatial and energy resolved distributions of the laser-accelerated proton beams. The resulting proton distribution is in fair agreement with the spectrum that was measured with a Thomson spectrometer in combination with a microchannel plate detector.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

The National Solar Radiation Database (NSRDB) for CSP Applications

This study examines the differences in direct normal irradiance (DNI) in two versions of the National Solar Radiation Database (NSRDB) produced by the National Renewable Energy Laboratory (NREL). NSRDB V3 of the NSRDB includes significant changes to various parts of the radiative transfer model and inputs to the model compared to NSRDB V2. The changes in NSRDB V3 resulted in lower uncertainty than NSRDB V2. The study quantified the uncertainty and the spatial and temporal variability under clear-sky conditions. The uncertainty estimation was performed using a standardized method, The Guide to the Expression of Uncertainty in Measurement (GUM). The evaluation of the accuracy of the NSRDB was conducted using high-quality ground-measurements for seven National Oceanic and Atmospheric Administration Surface Radiation Budget Network (SURFRAD) stations for 1998-2015.

14 SOLAR ENERGY↗

Synchrotron radiography of Richtmyer–Meshkov instability driven by exploding wire arrays

We present a new technique for the investigation of shock-driven hydrodynamic phenomena in gases, liquids, and solids in arbitrary geometries. The technique consists of a pulsed power-driven resistive wire array explosion in combination with multi-MHz synchrotron radiography. Compared to commonly used techniques, it offers multiple advantages: (1) the shockwave geometry can be shaped to the requirements of the experiment, (2) the pressure (P > 300 MPa) generated by the exploding wires enables the use of liquid and solid hydrodynamic targets with well-characterized initial conditions (ICs), (3) the multi-MHz radiography enables data acquisition to occur within a single experiment, eliminating uncertainties regarding repeatability of the ICs and subsequent dynamics, and (4) the radiographic measurements enable estimation of compression ratios from the x-ray attenuation. In addition, the use of a synchrotron x-ray source allows the hydrodynamic samples to be volumetrically characterized at a high spatial resolution with synchrotron-based microtomography. This experimental technique is demonstrated by performing a planar Richtmyer–Meshkov instability (RMI) experiment on an aerogel–water interface characterized by Atwood number A0∼−0.8 and Mach number M∼1.5. The qualitative and quantitative features of the experiment are discussed, including the energy deposition into the exploding wires, shockwave generation, compression of the interface, startup phase of the instability, and asymptotic growth consistent with Richtmyer's impulsive theory. Additional effects unique to liquids and solids—such as cavitation bubbles caused by rarefaction flows or initial jetting due to small perturbations—are observed. It is also demonstrated that the technique is not shape dependent by driving a cylindrically convergent RMI experiment.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

A Multilevel in Space and Energy Solver for 3-D Multigroup Diffusion and Coarse-Mesh Finite Difference Eigenvalue Problems

The Multilevel in Space and Energy Diffusion (MSED) method accelerates the iterative convergence of multigroup diffusion eigenvalue problems by performing work on lower-order equations with only one group and/or coarser spatial grids. It consists of two primary components: (1) a grey (one-group) diffusion eigenvalue problem that is solved via Wielandt-shifted power iteration (PI) and (2) a multigrid-in-space linear solver. In previous work, the efficiency of MSED was verified using Fourier analysis and numerical results from a one-dimensional multigroup diffusion code. Since that work, MSED has been implemented as a solver for the coarse-mesh finite difference (CMFD) system in the three-dimensional Michigan Parallel Characteristics Transport (MPACT) code. In this paper, the results from the implementation of MSED in MPACT are introduced, and the changes needed to make MSED more suitable for MPACT are described. For problems without feedback, the conclusions in this paper show that MSED can reduce the CMFD run time by an order of magnitude and the overall run time by a factor of 2 to 3 compared to the default CMFD solver in MPACT [PI with the generalized minimal residual (GMRES) method]. For problems with feedback, the convergence of the outer Picard iteration scheme is worsened by the well-converged CMFD solutions produced by the standard MSED method. To overcome this unintuitive deficiency, MSED may be run with looser convergence criteria (a modified version of the MSED method called MSED-L) to circumvent the issue until the multiphysics iteration in MPACT is improved. Results show that MSED-L can reduce the CMFD run time in MPACT by an order of magnitude, without negatively impacting the outer Picard iteration scheme.

3-D↗

THE MECHANISMS FOR THE ONSET AND EXPLOSIVE ERUPTION OF CORONAL MASS EJECTIONS AND ERUPTIVE FLARES

We have investigated the onset and acceleration of coronal mass ejections (CMEs) and eruptive flares. To isolate the eruption physics, our study uses the breakout model, which is insensitive to the energy buildup process leading to the eruption. We performed 2.5D simulations with adaptive mesh refinement that achieved the highest overall spatial resolution to date in a CME/eruptive flare simulation. The ultra-high resolution allows us to separate clearly the timing of the various phases of the eruption. Using new computational tools, we have determined the number and evolution of all X- and O-type nulls in the system, thereby tracking both the progress and the products of reconnection throughout the computational domain. Our results show definitively that CME onset is due to the start of fast reconnection at the breakout current sheet. Once this reconnection begins, eruption is inevitable; if this is the only reconnection in the system, however, the eruption will be slow. The explosive CME acceleration is triggered by fast reconnection at the flare current sheet. Our results indicate that the explosive eruption is caused by a resistive instability, not an ideal process. Moreover, both breakout and flare reconnections begin first as a form of weak tearing characterized by slowly evolving plasmoids, but eventually transition to a fast form with well-defined Alfvenic reconnection jets and rapid flux transfer. This transition to fast reconnection is required for both CME onset and explosive acceleration. We discuss the key implications of our results for CME/flare observations and for theories of magnetic reconnection.

79 ASTRONOMY AND ASTROPHYSICS↗

Anisotropic Lyman-alpha emission

As a result of resonant scatterings off hydrogen atoms, Lyα emission from star-forming galaxies provides a probe of the (hardly isotropic) neutral gas environment around them. We study the effect of the environmental anisotropy on the observed Lyα emission by performing radiative transfer calculations for models of neutral hydrogen clouds with prescriptions of spatial and kinematic anisotropies. The environmental anisotropy leads to corresponding anisotropy in the Lyα flux and spectral properties and induces correlations among them. The Lyα flux (or observed luminosity) depends on the viewing angle and shows an approximate correlation with the initial Lyα optical depth in the viewing direction relative to those in all other directions. The distribution of Lyα flux from a set of randomly oriented clouds is skewed to high values, providing a natural contribution to the Lyα equivalent width (EW) distribution seen in observation. A narrower EW distribution is found at a larger peak offset of the Lyα line, similar to the trend suggested in observation. The peak offset appears to correlate with the line shape (full width at half-maximum and asymmetry), pointing to a possibility of using Lyα line features alone to determine the systemic redshifts of galaxies. The study suggests that anisotropies in the spatial and kinematic distributions of neutral hydrogen can be an important ingredient in shaping the observed properties of Lyα emission from star-forming galaxies. We discuss the implications of using Lyα emission to probe the circumgalactic and intergalactic environments of galaxies.

79 ASTRONOMY AND ASTROPHYSICS↗

Strong violations of Bell-type inequalities for path-entangled number states

We show that nonlocal correlation experiments on the two spatially separated modes of a maximally path-entangled number state may be performed. They lead to a violation of a Clauser-Horne Bell inequality for any finite photon number N. We also present an analytical expression for the two-mode Wigner function of a maximally path-entangled number state and investigate a Clauser-Horne-Shimony-Holt Bell inequality for such a state. We test other Bell-type inequalities. Some are violated by a constant amount for any N.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Separating expansion from contraction in spherically symmetric models with a perfect fluid: Generalization of the Tolman-Oppenheimer-Volkoff condition and application to models with a cosmological constant

We investigate spherically symmetric perfect-fluid spacetimes and discuss the existence and stability of a dividing shell separating expanding and collapsing regions. We perform a 3+1 splitting and obtain gauge invariant conditions relating the intrinsic spatial curvature of the shells to the Misner-Sharp mass and to a function of the pressure that we introduce and that generalizes the Tolman-Oppenheimer-Volkoff equilibrium condition. We find that surfaces fulfilling those two conditions fit, locally, the requirements of a dividing shell, and we argue that cosmological initial conditions should allow its global validity. We analyze the particular cases of the Lemaitre-Tolman-Bondi dust models with a cosmological constant as an example of a cold dark matter model with a cosmological constant ({Lambda}-CDM model) and its generalization to contain a central perfect-fluid core. These models provide simple but physically interesting illustrations of our results.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Charmonium-nucleon potential from lattice QCD

We present results for the charmonium-nucleon potential V{sub cc-N}(r) from quenched lattice QCD, which is calculated from the equal-time Bethe-Salpeter amplitude through the effective Schroedinger equation. Detailed information of the low-energy interaction between the nucleon and charmonia ({eta}{sub c} and J/{psi}) is indispensable for exploring the formation of charmonium bound to nuclei. Our simulations are performed at a lattice cutoff of 1/a{approx_equal}2.1 GeV in a spatial volume of (3 fm){sup 3} with the nonperturbatively O(a) improved Wilson action for the light quarks and a relativistic heavy quark action for the charm quark. We have found that the potential V{sub cc-N}(r) for either the {eta}{sub c} or J/{psi} states is weakly attractive at short distances and exponentially screened at large distances. The spin averaged J/{psi}-N potential is slightly more attractive than that of the {eta}{sub c}-N case.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

High resolution DEPFET active pixel sensors for the Belle II experiment

The new Belle II experiment at the SuperKEKB collider at KEK was launched in 2009 as a general upgrade of the previous successful Belle experiment. Important improvements in the Belle II detector are additional two pixel layers forming the innermost part of the vertex detector. This paper gives a short overview of the expected impact of the two inner pixel layers on the performance of Belle II based on simulations and current experimental knowledge of the DEPFET pixel detectors. The focus is on the expected performance of the thinned DEPFET pixel sensors in Belle II in terms of spatial resolution. The measurements and simulations of the current generation of DEPFET sensors in beam tests indicate that the design resolution requirements can be met. The dependence of the spatial resolution on the deposited energy was observed in beam tests and we simulated the effect for the Belle II detector type to estimate its magnitude. A short description of the readout and data acquisition chain of the Belle II pixel vertex detector is given. (authors)

43 PARTICLE ACCELERATORS↗

ADDS-EVS: An agent-based deployment decision-support system for electric vehicle services

Rapid and sustainable development of the electric vehicle (EV) industry places the requirement for the plan of EV deployment. For public EV, existing models mainly focus on the charging facility design and fail to capture the multi-modal scenarios. In this work, we develop an agent-based decision-support system for multi-modal electric transits to locate the optimal combinations of key parameters, including the fleet size, the transit schedule, the charging facility design, and the routing strategy. We demonstrate the utilities of our system by simulating public EV services deployed to serve travel needs related to a transportation hub in New York City. To support the decision of the fleet size, we summarize system-level performances including the total satisfied demand, passengers' waiting time, vehicle idling time. The spatial and temporal patterns are extracted to serve a deeper understanding of system dynamics and service quality. Finally, we investigate the interaction between the fleet size design and the routing strategy. The results suggest a necessity of integrating the operation strategies into the planning phase.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Scalable measurements of tow architecture variability in braided ceramic composite tubes

Abstract The performance of braided ceramic matrix composites has been shown to depend on the spatial arrangement of tows; therefore, a new class of tools is required to measure irregularities in the composite architecture for components with intricate geometries. We report a scalable and robust reconstruction technique built upon stereoscopic digital image correlation that is able to efficiently measure the position of tows in arbitrarily shaped composites. This method was applied to triaxially braided ceramic matrix composite tubes intended for use as nuclear fuel cladding, which revealed both long‐range “systematic” tow packing defects associated with the manufacturing process and short‐range “intrinsic” defects due to the braid architecture. These findings suggested that the character of tow spacing variation in braided composite tubes was substantially more complex than in planar woven composites. These measurements are expected to lead to improved processing of braided composites and to facilitate the design of statistically representative virtual specimens for finite element modeling.

Heim, Frederick M.↗

Systematic calibration of an integrated x-ray and optical tomography system for preclinical radiation research

Purpose: The cone beam computed tomography (CBCT) guided small animal radiation research platform (SARRP) has been developed for focal tumor irradiation, allowing laboratory researchers to test basic biological hypotheses that can modify radiotherapy outcomes in ways that were not feasible previously. CBCT provides excellent bone to soft tissue contrast, but is incapable of differentiating tumors from surrounding soft tissue. Bioluminescence tomography (BLT), in contrast, allows direct visualization of even subpalpable tumors and quantitative evaluation of tumor response. Integration of BLT with CBCT offers complementary image information, with CBCT delineating anatomic structures and BLT differentiating luminescent tumors. This study is to develop a systematic method to calibrate an integrated CBCT and BLT imaging system which can be adopted onboard the SARRP to guide focal tumor irradiation. Methods: The integrated imaging system consists of CBCT, diffuse optical tomography (DOT), and BLT. The anatomy acquired from CBCT and optical properties acquired from DOT serve as a priori information for the subsequent BLT reconstruction. Phantoms were designed and procedures were developed to calibrate the CBCT, DOT/BLT, and the entire integrated system. Geometrical calibration was performed to calibrate the CBCT system. Flat field correction was performed to correct the nonuniform response of the optical imaging system. Absolute emittance calibration was performed to convert the camera readout to the emittance at the phantom or animal surface, which enabled the direct reconstruction of the bioluminescence source strength. Phantom and mouse imaging were performed to validate the calibration. Results: All calibration procedures were successfully performed. Both CBCT of a thin wire and a euthanized mouse revealed no spatial artifact, validating the accuracy of the CBCT calibration. The absolute emittance calibration was validated with a 650 nm laser source, resulting in a 3.0% difference between simulated and measured signal. The calibration of the entire system was confirmed through the CBCT and BLT reconstruction of a bioluminescence source placed inside a tissue-simulating optical phantom. Using a spatial region constraint, the source position was reconstructed with less than 1 mm error and the source strength reconstructed with less than 24% error. Conclusions: A practical and systematic method has been developed to calibrate an integrated x-ray and optical tomography imaging system, including the respective CBCT and optical tomography system calibration and the geometrical calibration of the entire system. The method can be modified and adopted to calibrate CBCT and optical tomography systems that are operated independently or hybrid x-ray and optical tomography imaging systems.

60 APPLIED LIFE SCIENCES↗

SU-D-BRC-01: An Automatic Beam Model Commissioning Method for Monte Carlo Simulations in Pencil-Beam Scanning Proton Therapy

Purpose: Monte Carlo (MC) simulation is typically regarded as the most accurate dose calculation method for proton therapy. Yet for real clinical cases, the overall accuracy also depends on that of the MC beam model. Commissioning a beam model to faithfully represent a real beam requires finely tuning a set of model parameters, which could be tedious given the large number of pencil beams to commmission. This abstract reports an automatic beam-model commissioning method for pencil-beam scanning proton therapy via an optimization approach. Methods: We modeled a real pencil beam with energy and spatial spread following Gaussian distributions. Mean energy, and energy and spatial spread are model parameters. To commission against a real beam, we first performed MC simulations to calculate dose distributions of a set of ideal (monoenergetic, zero-size) pencil beams. Dose distribution for a real pencil beam is hence linear superposition of doses for those ideal pencil beams with weights in the Gaussian form. We formulated the commissioning task as an optimization problem, such that the calculated central axis depth dose and lateral profiles at several depths match corresponding measurements. An iterative algorithm combining conjugate gradient method and parameter fitting was employed to solve the optimization problem. We validated our method in simulation studies. Results: We calculated dose distributions for three real pencil beams with nominal energies 83, 147 and 199 MeV using realistic beam parameters. These data were regarded as measurements and used for commission. After commissioning, average difference in energy and beam spread between determined values and ground truth were 4.6% and 0.2%. With the commissioned model, we recomputed dose. Mean dose differences from measurements were 0.64%, 0.20% and 0.25%. Conclusion: The developed automatic MC beam-model commissioning method for pencil-beam scanning proton therapy can determine beam model parameters with satisfactory accuracy.

60 APPLIED LIFE SCIENCES↗