Search NASA⌕ Search

SEARCH · Search NASA

Results for “study protocol”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,423 records · Page 79

Influence of electrical field on the susceptibility of gallium nitride transistors to proton irradiation

Radiation susceptibility of electronic devices is commonly studied as a function of radiation energetics and device physics. Often overlooked is the presence or magnitude of the electrical field, which we hypothesize to play an influential role in low energy radiation. Accordingly, we present a comprehensive study of low-energy proton irradiation on gallium nitride high electron mobility transistors (HEMTs), turning the transistor ON or OFF during irradiation. Commercially available GaN HEMTs were exposed to 300 keV proton irradiation at fluences varying from 3.76 × 10 12 to 3.76 × 10 14 cm 2 , and the electrical performance was evaluated in terms of forward saturation current, transconductance, and threshold voltage. The results demonstrate that the presence of an electrical field makes it more susceptible to proton irradiation. The decrease of 12.4% in forward saturation and 19% in transconductance at the lowest fluence in ON mode suggests that both carrier density and mobility are reduced after irradiation. Additionally, a positive shift in threshold voltage (0.32 V and 0.09 V in ON and OFF mode, respectively) indicates the generation of acceptor-like traps due to proton bombardment. high-resolution transmission electron microscopy and energy dispersive x-ray spectroscopy analysis reveal significant defects introduction and atom intermixing near AlGaN/GaN interfaces and within the GaN layer after the highest irradiation dose employed in this study. According to in-situ Raman spectroscopy, defects caused by irradiation can lead to a rise in self-heating and a considerable increase in (∼750 times) thermoelastic stress in the GaN layer during device operation. The findings indicate device engineering or electrical biasing protocol must be employed to compensate for radiation-induced defects formed during proton irradiation to improve device durability and reliability.

gallium nitride↗

Characterizing Rat PNS Electrophysiological Response to Electrical Stimulation Using in vitro Chip-Based Human Investigational Platform (iCHIP)

Ex vivo systems and organ-on-a-chip technology offer an unprecedented approach to modeling the inner workings of the human body. The ultimate goal of LLNL’s in vitro Chip-based Human Investigational Platform (iCHIP) is to integrate multiple organ tissue cultures using microfluidic channels, multi-electrode arrays (MEA), and other biosensors in order to effectively simulate and study the responses and interactions of the major organs to chemical and physical stimulation. In this study, we focused on the peripheral nervous system (PNS) component of the iCHIP system. Specifically we sought to expound on prior research investigating the electrophysiological response of rat dorsal root ganglion cells (rDRGs) to chemical exposures, such as capsaicin. Our aim was to establish a protocol for electrical stimulation using the iCHIP device that would reliably elicit a characteristic response in rDRGs. By varying the parameters for both the stimulation properties – amplitude, phase width, phase shape, and stimulation/ return configuration – and the culture conditions – day in vitro and neural cell types - we were able to make several key observations and uncover a potential convention with a minimal number of devices tested. Future work will seek to establish a standard protocol for human DRGs in the iCHIP which will afford a portable, rapid method for determining the effects of toxins and novel therapeutics on the PNS.

42 ENGINEERING↗

Editorial: Towards the rapid and systematic assessment of vaccine technologies

The COVID-19 pandemic highlighted both the extraordinary potential of modern vaccinology and persistent challenges in how vaccine technologies are assessed. While vaccines can be developed and deployed at unprecedented speed, our ability to predict efficacy in a population is constrained by methodological difficulties, underreporting of negative results, and limited comparability across studies. This editorial introduces a Research Topic that brings together an interdisciplinary collection of experimental, computational, and theoretical contributions spanning multiple pathogens and vaccine platforms. Across these contributions, emerging themes emphasize the need for standardized immunogenicity metrics, transparent reporting including negative findings, and harmonized experimental protocols to support meaningful comparisons. This editorial highlights community practices and shared commitments – supported by researchers, funders, and journals – that could strengthen reproducibility, transparency, and cumulative learning in vaccine research.

59 BASIC BIOLOGICAL SCIENCES↗

SU-E-J-142: Performance Study of Automatic Image-Segmentation Algorithms in Motion Tracking Via MR-IGRT

Purpose: Evaluate commonly used segmentation algorithms on a commercially available real-time MR image guided radiotherapy (MR-IGRT) system (ViewRay), compare the strengths and weaknesses of each method, with the purpose of improving motion tracking for more accurate radiotherapy. Methods: MR motion images of bladder, kidney, duodenum, and liver tumor were acquired for three patients using a commercial on-board MR imaging system and an imaging protocol used during MR-IGRT. A series of 40 frames were selected for each case to cover at least 3 respiratory cycles. Thresholding, Canny edge detection, fuzzy k-means (FKM), k-harmonic means (KHM), and reaction-diffusion level set evolution (RD-LSE), along with the ViewRay treatment planning and delivery system (TPDS) were included in the comparisons. To evaluate the segmentation results, an expert manual contouring of the organs or tumor from a physician was used as a ground-truth. Metrics value of sensitivity, specificity, Jaccard similarity, and Dice coefficient were computed for comparison. Results: In the segmentation of single image frame, all methods successfully segmented the bladder and kidney, but only FKM, KHM and TPDS were able to segment the liver tumor and the duodenum. For segmenting motion image series, the TPDS method had the highest sensitivity, Jarccard, and Dice coefficients in segmenting bladder and kidney, while FKM and KHM had a slightly higher specificity. A similar pattern was observed when segmenting the liver tumor and the duodenum. The Canny method is not suitable for consistently segmenting motion frames in an automated process, while thresholding and RD-LSE cannot consistently segment a liver tumor and the duodenum. Conclusion: The study compared six different segmentation methods and showed the effectiveness of the ViewRay TPDS algorithm in segmenting motion images during MR-IGRT. Future studies include a selection of conformal segmentation methods based on image/organ-specific information, different filtering methods and their influences on the segmentation results. Parag Parikh receives research grant from ViewRay. Sasa Mutic has consulting and research agreements with ViewRay. Yanle Hu receives travel reimbursement from ViewRay. Iwan Kawrakow and James Dempsey are ViewRay employees.

60 APPLIED LIFE SCIENCES↗

Stereotactic Body Radiotherapy for Medically Inoperable Lung Cancer: Prospective, Single-Center Study of 108 Consecutive Patients

Purpose: To present the results of stereotactic body radiotherapy (SBRT) for medically inoperable patients with Stage I non-small-cell lung cancer (NSCLC) and contrast outcomes in patients with and without a pathologic diagnosis. Methods and Materials: Between December 2004 and October 2008, 108 patients (114 tumors) underwent treatment according to the prospective research ethics board-approved SBRT protocols at our cancer center. Of the 108 patients, 88 (81.5%) had undergone pretreatment whole-body [18F]-fluorodeoxyglucose positron emission tomography/computed tomography. A pathologic diagnosis was unavailable for 33 (28.9%) of the 114 lesions. The SBRT schedules included 48 Gy in 4 fractions or 54-60 Gy in 3 fractions for peripheral lesions and 50-60 Gy in 8-10 fractions for central lesions. Toxicity and radiologic response were assessed at the 3-6-month follow-up visits using conventional criteria. Results: The mean tumor diameter was 2.4-cm (range, 0.9-5.7). The median follow-up was 19.1 months (range, 1-55.7). The estimated local control rate at 1 and 4 years was 92% (95% confidence interval [CI], 86-97%) and 89% (95% CI, 81-96%). The cause-specific survival rate at 1 and 4 years was 92% (95% CI, 87-98%) and 77% (95% CI, 64-89%), respectively. No statistically significant difference was found in the local, regional, and distant control between patients with and without pathologically confirmed NSCLC. The most common acute toxicity was Grade 1 or 2 fatigue (53 of 108 patients). No toxicities of Grade 4 or greater were identified. Conclusions: Lung SBRT for early-stage NSCLC resulted in excellent local control and cause-specific survival with minimal toxicity. The disease-specific outcomes were comparable for patients with and without a pathologic diagnosis. SBRT can be considered an option for selected patients with proven or presumed early-stage NSCLC.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

SU-F-R-27: Use Local Shape Descriptor Based On Geodesic Distance to Predict Survival in Non-Small Cell Lung Cancer After Radiotherapy

Purpose: The shape of the Positron Emission Tomography (PET) image represents the heterogeneity of tumor growth in various directions, and thus could be associated with tumor malignancy. We have proposed a median geodesic distance (MGD) to represent the local complexity of the shape and use a normalized MGD (NMGD) to quantify the shape, and found a potential correlation of NMGD to survival in a 20-patient pilot study. This study was to verify the finding in a larger patient cohort. Methods: Geodesic distance of two vertices on a surface is defined as the shortest path on the surface connecting the two vertices. The MGD was calculated for each vertex on the surface to display the local complexity of the shape. The NMGD was determined as: NMGD = 100*standard deviation(MGDs)/mean(MGDs). We applied the NMGD to 40 NSCLC patients who were enrolled in prospective PET image protocols and received radiotherapy. Each patient had a pre-treatment PET scan with the resolution of 4mm*4mm*5mm. Tumors were contoured by a professional radiation oncologist and triangulation meshes were built up based on the contours. Results: The mean and standard deviation of NMGD was 6.4±3.0. The OS was 33.1±16.9 months for low NMGD group, and 15.4±15.6 months for the high NMGD group. The low NMGD group had significant better OS than the high NMGD group (p=0.0013). Conclusion: NMGD could be used as a shape biomarker to predict survival and the MGD could be combined with image texture in future to increase prediction accuracy. This study was supported by Award Number 1R01CA166948 from the NIH and National Cancer Institute.

60 APPLIED LIFE SCIENCES↗

Cytosolic expression, solution structures, and molecular dynamics simulation of genetically encodable disulfide‐rich de novo designed peptides

Abstract Disulfide‐rich peptides represent an important protein family with broad pharmacological potential. Recent advances in computational methods have made it possible to design new peptides which adopt a stable conformation de novo. Here, we describe a system to produce disulfide‐rich de novo peptides using Escherichia coli as the expression host. The advantage of this system is that it enables production of uniformly 13 C‐ and 15 N‐labeled peptides for solution nuclear magnetic resonance (NMR) studies. This expression system was used to isotopically label two previously reported de novo designed peptides, and to determine their solution structures using NMR. The ensemble of NMR structures calculated for both peptides agreed well with the design models, further confirming the accuracy of the design protocol. Collection of NMR data on the peptides under reducing conditions revealed a dependency on disulfide bonds to maintain stability. Furthermore, we performed long‐time molecular dynamics (MD) simulations with tempering to assess the stability of two families of de novo designed peptides. Initial designs which exhibited a stable structure during simulations were more likely to adopt a stable structure in vitro , but attempts to utilize this method to redesign unstable peptides to fold into a stable state were unsuccessful. Further work is therefore needed to assess the utility of MD simulation techniques for de novo protein design.

Buchko, Garry W.↗

Enhanced Quantum Synchronization via Quantum Machine Learning

Abstract The quantum synchronization between a pair of two‐level systems inside two coupled cavities is studied. By using a digital–analog decomposition of the master equation that rules the system dynamics, it is shown that this approach leads to quantum synchronization between both two‐level systems. Moreover, in this digital–analog block decomposition, the fundamental elements of a quantum machine learning protocol can be identified, in which the agent and the environment (learning units) interact through a mediating system, namely, the register. If the algorithm can be additionally equipped with a classical feedback mechanism, which consists of projective measurements in the register, reinitialization of the register state, and local conditional operations on the agent and environment subspace, a powerful and flexible quantum machine learning protocol emerges. Indeed, numerical simulations show that this protocol enhances the synchronization process, even when every subsystem experiences different loss/decoherence mechanisms, and gives the flexibility to choose the synchronization state. Finally, an implementation is proposed, based on current technologies in superconducting circuits.

Cárdenas‐López, Francisco A.↗

Gravitational waves from global cosmic strings and cosmic archaeology

Global cosmic strings are predicted in many motivated extensions to the Standard Model of particle physics, with close connections to axion dark matter physics. Recent studies suggest that, although subdominant relative to Goldstone emission, gravitational wave (GW) signals from global strings can be detectable with current and planned GW detectors such as LIGO, LISA, DECIGO/BBO, ET/CE and AEDGE/AION, as well as pulsar timing arrays such as PPTA, NANOGrav and SKA. This work is an extensive, updated study on GWs from a global cosmic string network, taking into account of the most recent developments related to the subject. The main analysis is based on the analytical Velocity-dependent One-Scale (VOS) model calibrated with recent simulation results, which provides a generic protocol for such calculations with details given. We also demonstrate how the GW signal can be influenced with variations to the baseline model: this includes considering the uncertainties of model parameters and the potential deviation from the conventional VOS model prediction (i.e. the scaling behavior) as suggested by some of the recent simulation results. Furthermore, we investigated in detail the effect of a non-standard cosmology (e.g. early matter domination or kination) or new particle species on the GW signals from global strings. We demonstrate that the frequency spectrum of GW background from global cosmic strings can be used to probe the cosmic history prior to the Big Bang nucleosynthesis (BBN) (i.e. the primordial dark age) up to a temperature of T ~ 10 8 GeV.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Purified discord and multipartite entanglement

We study bipartite quantum discord as a manifestation of a multipartite entanglement structure in the tripartite purified system. In particular, we find that bipartite quantum discord requires the presence of both bipartite and tripartite entanglement in the purification. This allows one to understand the asymmetry of quantum discord, D(A,B)≠D(B,A) in terms of entanglement monogamy. As instructive special cases, we study discord for qubits and Gaussian states in detail. As a result of this we shed new light on a counterintuitive property of Gaussian states: the presence of classical correlations necessarily requires the presence of quantum correlations. Finally, our results also shed new light on a protocol for remote activation of entanglement by a third party. -- Highlights: •Bipartite quantum discord as a manifestation of multipartite entanglement. •Relevance of quantum discord as a utilizable resource for quantum info. tasks. •Quantum discord manifests itself in entanglement in the purified state. •Relation between asymmetry of discord and entanglement monogamy. •Protocol for remote activation of entanglement by a third party.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Dosimetric impact of translational and rotational setup errors for spine stereotactic body radiotherapy: A phantom study

This study aimed to investigate experimentally the effect of translational and rotational setup errors on 3-dimensional dose distributions by using the gamma index and dose volumetric indices for spine stereotactic body radiotherapy. Treatment plans were designed in accordance with the Radiation Therapy Oncology Group (RTOG) 0631 protocol. Measurements were taken using a Delta4 phantom (ScandiDos, Uppsala, Sweden). Setup errors were generated using the HexaMotion 6D moving platform (ScandiDos). Dose distributions in the presence of setup errors were evaluated, according to the γ passing rate with the 3% and 2 mm criteria (γ{sub 3%/2 mm}) and dose volumetric indices (D{sub 90} for the target volume and D{sub 2} for the spinal cord), using the Delta4 device (ScandiDos). The sensitivity coefficient, which represented the correlation between the γ{sub 3%/2 mm} passing rate and dose volumetric indices, was determined to assess robustness against setup errors. Rotational setup errors of 2° were equivalent to translational setup errors of 2 mm for the γ{sub 3%/2 mm} passing rate, D{sub 90} for the target, and D{sub 2} for the spinal cord. D{sub 90} for the target had low robustness against a translational setup error in the vertical direction and a rotational setup error in the pitch direction. D{sub 2} for the spinal cord was sensitive to a translational setup error in the lateral direction and a rotational setup error in the roll direction. The positioning accuracy of the rotational setup error, corresponding to the tolerance level of image-guided radiotherapy in the RTOG 0631 protocol, was required to be ≤ 2°.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Longitudinal analysis of risk factors for dementia based on Mild Cognitive Impairment Screen results and questionnaire responses from healthy Japanese individuals registered in an online database

Abstract Introduction Despite an urgent need for developing remedial measures against dementia, no disease‐modifying drugs have been developed. Efficient protocols for participant recruitment need to be established for conducting clinical trials. To meet this need, a large‐scale online registry system, the Integrated Registry of Orange Plan (IROOP ® ), was created for healthy individuals. Although the risk factors for dementia have been discussed in our previous studies for a short interval of 6 months, some factors remain controversial. The present study aimed to explore factors affecting longitudinal changes in cognitive function for a longer interval of 18 months using the IROOP ® data. Methods This study assessed the longitudinal changes in the collated data for predicting the risk of dementia and included 473 individuals (175 men and 298 women; mean age 59.6 ± 10.1 years) registered in the IROOP ® between July 5, 2016 and January 15, 2018 who completed the initial questionnaire and brief assessment of cognitive function (Mild Cognitive Impairment Screen) at baseline and the regular questionnaire and the Mild Cognitive Impairment Screen at least once after baseline. Statistical analyses were performed using IBM SPSS, version 23.0, for Windows for demographic data and the MIXED procedure in SAS, version 9.4, for the linear mixed‐effect model. In each analysis, the statistical significance level was set at P < .05. Results Mood, sleep, quality of life, and medical histories including cognition were found to influence longitudinal changes in cognitive function. Discussion Given the multifactorial etiology of dementia, preventive measures targeting multiple domains are required for maintaining cognitive function, instead of focusing on one lifestyle factor.

Ogawa, Masayo↗

SU-E-T-309: Dosimetric Comparison of Simultaneous Integrated Boost Treatment Plan Between Intensity Modulated Radiotherapies (IMRTs), Dual Arc Volumetric Modulated Arc Therapy (DA-VMAT) and Single Arc Volumetric Modulated Arc Therapy (SA-VMAT) for Nasopharyngeal Carcinoma (NPC)

Purpose: To compare the plan quality and performance of Simultaneous Integrated Boost (SIB) Treatment plan between Seven field (7F) and Nine field(9F) Intensity Modulated Radiotherapies and Single Arc (SA) and Dual Arc (DA) Volumetric Modulated Arc Therapy( VMAT). Methods: Retrospective planning study of 16 patients treated in Elekta Synergy Platform (mlci2) by 9F-IMRT were replanned with 7F-IMRT, Single Arc VMAT and Dual Arc VMAT using CMS, Monaco Treatment Planning System (TPS) with Monte Carlo simulation. Target delineation done as per Radiation Therapy Oncology Protocols (RTOG 0225&0615). Dose Prescribed as 70Gy to Planning Target Volumes (PTV70) and 61Gy to PTV61 in 33 fraction as a SIB technique. Conformity Index(CI), Homogeneity Index(HI) were used as analysis parameter for Target Volumes as well as Mean dose and Max dose for Organ at Risk(OAR,s).Treatment Delivery Time(min), Monitor unit per fraction (MU/fraction), Patient specific quality assurance were also analysed. Results: A Poor dose coverage and Conformity index (CI) was observed in PTV70 by 7F-IMRT among other techniques. SA-VMAT achieved poor dose coverage in PTV61. No statistical significance difference observed in OAR,s except Spinal cord (P= 0.03) and Right optic nerve (P=0.03). DA-VMAT achieved superior target coverage, higher CI (P =0.02) and Better HI (P=0.03) for PTV70 other techniques (7F-IMRT/9F-IMRT/SA-VMAT). A better dose spare for Parotid glands and spinal cord were seen in DA-VMAT. The average treatment delivery time were 5.82mins, 6.72mins, 3.24mins, 4.3mins for 7F-IMRT, 9F-IMRT, SA-VMAT and DA-VMAT respectively. Significance difference Observed in MU/fr (P <0.001) and Patient quality assurance pass rate were >95% (Gamma analysis (Γ3mm, 3%). Conclusion: DA-VAMT showed better target dose coverage and achieved better or equal performance in sparing OARs among other techniques. SA-VMAT offered least Treatment Time than other techniques but achieved poor target coverage. DA-VMAT offered shorter delivery time than 7F-IMRT and 9F-IMRT without compromising the plan quality.

60 APPLIED LIFE SCIENCES↗

SU-E-T-407: Evaluation of the Stopping Power and Imaging Visibility for Iodine Based Contrast in Proton Therapy

Purpose: The purpose of this study was to investigate the difference between calculated and measured relative linear stopping power (RLSP) for contrast medium in proton therapy. Furthermore, the visibility for different concentrations in prostate phantom on orthogonal X-ray system was evaluated Methods and Materials: In prostate cancer patient, rectal balloon along with the contrast media was used to visualize the balloon position, thus facilitating the patient setup during each fraction of the uniform scanning proton treatment. There were no fiducial markers implanted in the prostate for this patient. A blue wax phantom with outer dimensions 10cm(H) x 14.5cm(L) x 10cm(W) was made in house. To hold iodine based contrast solution, a rectangular shaped hole with dimensions 7cm(H) x 8cm(L) x 4cm(W) was made inside the phantom. Organically bound 8.5% iodine based Cystografin Dilute contrast agent with molecular formula C11H9I3N2O4.C7H17NO5 was used in this study. Six solutions were prepared; each mixture of water and iodine based contrast agent at different concentrations as 0%, 5%, 10%, 20%, 30% and 50%. During computed tomographic(CT) simulation, solutions were placed together at the isocenter of CT and scanned at 120kVp using the same protocol as for prostate cancer patients. The treatment planning was done in CMS-XiO system. Multi-layer-ion-chamber (MLIC) was used to measure residual proton range. Results: The 50% concentration contrast solution was used during treatment for better visualization on orthogonal X-ray image. The measured RLSP for 5%, 10%, 20%, 30% & 50% solutions were 1.005, 1.010, 1.018, 1.023 & 1.033; and similarly calculated RLSP from XiO were 1.090, 1.135, 1.222, 1.299 & 1.448 respectively. Conclusion: The treatment planning system could overestimates the relative stopping power of contrast solution with high concentrations. It is recommended to override the contrast with measured RLSP for high atomic number based contrast solution in treatment planning for proton therapy.

60 APPLIED LIFE SCIENCES↗

SU-G-IeP3-04: Effective Dose Measurements in Fast Kvp Switch Dual Energy Computed Tomography

Purpose: The objective of this study was two-fold: (a) to test a new approach to approximating organ dose by using the effective energy of the combined 80kV/140kV beam in dual-energy (DE) computed tomography (CT), and (b) to derive the effective dose (ED) in the abdomen-pelvis protocol in DECT. Methods: A commercial dual energy CT scanner was employed using a fast-kV switch abdomen/pelvis protocol alternating between 80 kV and 140 kV. MOSFET detectors were used for organ dose measurements. First, an experimental validation of the dose equivalency between MOSFET and ion chamber (as a gold standard) was performed using a CTDI phantom. Second, the ED of DECT scans was measured using MOSFET detectors and an anthropomorphic phantom. For ED calculations, an abdomen/pelvis scan was used using ICRP 103 tissue weighting factors; ED was also computed using the AAPM Dose Length Product (DLP) method and compared to the MOSFET value. Results: The effective energy was determined as 42.9 kV under the combined beam from half-value layer (HVL) measurement. ED for the dual-energy scan was calculated as 16.49 ± 0.04 mSv by the MOSFET method and 14.62 mSv by the DLP method. Conclusion: Tissue dose in the center of the CTDI body phantom was 1.71 ± 0.01 cGy (ion chamber) and 1.71 ± 0.06 (MOSFET) respectively; this validated the use of effective energy method for organ dose estimation. ED from the abdomen-pelvis scan was calculated as 16.49 ± 0.04 mSv by MOSFET and 14.62 mSv by the DLP method; this suggests that the DLP method provides a reasonable approximation to the ED.

60 APPLIED LIFE SCIENCES↗

Optimization of Diode Laser System to Treat Benign Prostate Hyperplasia Final Report CRADA No. TSB-1154-95

Benign prostate hyperplasia (BPH) is a pervasive condition of enlargement of the male prostate gland which leads to several urinary difficulties ranging from hesitancy to incontinence to kidney dysfunction in severe cases. Currently the most common therapy is transurethral resection of the prostate (TURP) utilizing an electrosurgical device. Although TURP is largely successful, new BPH therapy methods are desired to reduce the cost and recovery time, improve the success rate, and reduce side effects. Recently, lasers have been introduced for this purpose. Indigo Medical Inc. is currently engaged in the development, testing, and preparation for sales of a new diode laser based BPH therapy system. The development is based on laboratory experiments, animal studies, and a limited FDA-approved clinical trial in the US and in other countries. The addition of sophisticated numerical modeling, of the sort that has been highly developed at Lawrence Livermore National Laboratory, can greatly aid in the design of the system and treatment protocol. The benefits to DOE include the maintenance and advancement of numerical modeling expertise in radiation-matter interactions of the sort essential for the stockpile stewardship, inertial confinement fusion, and advanced manufacturing, and the push on advanced scientific computational methods, ultimately in areas such as 3-D transport.

42 ENGINEERING↗

SIMS Analysis of d18O and d13C of Carbonate Cements in Shale & Mudstone. Final report

This project has had two primary goals: 1) improving new technology for in situ microanalysis of stable isotope ratios by SIMS (secondary ion mass spectrometry) and 2) evaluating the importance of in situ analysis for studies of carbonate cements within shales of the Bakken Petroleum System. The systematic relations of stable isotope ratios provide an important tool to help resolve critical questions in geology. Stable isotope analysis of carbonate cements in shale constrain many topics of interest to DOE including: CO2 sequestration, climate change, and the genesis and quality of rock reservoirs for petroleum, natural gas, and water. However, this evidence is often preserved as fine-scale zonation, which is homogenized by conventional bulk analysis of powders. Recently, analysis of ultra-small spots in polished samples at the University of Wisconsin WiscSIMS Lab. has documented stable isotope zoning in carbonates and other diagenetic cements at smaller scales than previously possible. We have made detailed studies of oxygen and carbon isotope ratios in diagenetic cements from shales of the Bakken Formation from the Williston basin and elsewhere. The Bakken contains both reservoir and source rocks for petroleum. Hydrofracturing has greatly enhanced production of oil in these tight reservoirs. The sediments contain zoned carbonate cements with growth textures that record multiple events. The growth of carbonate (dolomite) cements has been proposed to control reservoir quality, but previous stable isotope studies of homogenized powders could not resolve individual generations of cement and this proposal remains untested. Our better characterization of the multiple growth zones in these carbonates will aid in understanding the genesis of these tight reservoirs and the production of unconventional oil and gas. This study has also developed SIMS standards for analysis of all compositions of Ca-Mg-Fe carbonate and selected Mn-carbonates and hydromagnesite. We have refined techniques for improved accuracy of SIMS stable isotope analysis, and for sub-1-micron spot sizes. We have established protocols for mapping and correlating sample analyses at micron-scale using QGIS software.

04 OIL SHALES AND TAR SANDS↗

Moving the needle: Employing deep reinforcement learning to push the boundaries of coarse-grained vaccine models

Highly mutable infectious disease pathogens (hm-IDPs) such as HIV and influenza evolve faster than the human immune system can contain them, allowing them to circumvent traditional vaccination approaches and causing over one million deaths annually. Agent-based models can be used to simulate the complex interactions that occur between immune cells and hm-IDP-like proteins (antigens) during affinity maturation—the process by which antibodies evolve. Compared to existing experimental approaches, agent-based models offer a safe, low-cost, and rapid route to study the immune response to vaccines spanning a wide range of design variables. However, the highly stochastic nature of affinity maturation and vast sequence space of hm-IDPs render brute force searches intractable for exploring all pertinent vaccine design variables and the subset of immunization protocols encompassed therein. To address this challenge, we employed deep reinforcement learning to drive a recently developed agent-based model of affinity maturation to focus sampling on immunization protocols with greater potential to improve the chosen metrics of protection, namely the broadly neutralizing antibody (bnAb) titers or fraction of bnAbs produced. Using this approach, we were able to coarse-grain a wide range of vaccine design variables and explore the relevant design space. Our work offers new testable insights into how vaccines should be formulated to maximize protective immune responses to hm-IDPs and how they can be minimally tailored to account for major sources of heterogeneity in human immune responses and various socioeconomic factors. Our results indicate that the first 3 to 5 immunizations, depending on the metric of protection, should be specially tailored to achieve a robust protective immune response, but that beyond this point further immunizations require only subtle changes in formulation to sustain a durable bnAb response.

60 APPLIED LIFE SCIENCES↗