Two-Column Aerosol Project (TCAP): Ground-Based Radiation and Aerosol Validation Using the NOAA Mobile SURFRAD Station Field Campaign Report

The National Oceanic and Atmospheric Administration (NOAA) is preparing for the launch of the Geostationary Operational Environmental Satellite R-Series (GOES-R) satellite in 2015. This satellite will feature higher time (5-minute versus 30-minute sampling) and spatial resolution (0.5 km vs 1 km in the visible channel) than current GOES instruments provide. NOAA’s National Environmental Satellite Data and Information Service has funded the Global Monitoring Division at the Earth System Research Laboratory to provide ground-based validation data for many of the new and old products the new GOES instruments will retrieve specifically related to radiation at the surface and aerosol and its extensive and intensive properties in the column. The Two-Column Aerosol Project (TCAP) had an emphasis on aerosol; therefore, we asked to be involved in this campaign to de-bug our new instrumentation and to provide a new capability that the U.S. Department of Energy (DOE) Atmospheric Radiation Measurement (ARM) Climate Research Facility’s Mobile Facilities (AMF) did not possess, namely surface albedo measurement out to 1625 nm. This gave us a chance to test remote operation of our new multi-filter rotating shadowband radiometer/multi-filter radiometer (MFRSR/MFR) combination. We did not deploy standard broadband shortwave and longwave radiation instrumentation because ARM does this as part of every AMF deployment. As it turned out, the ARM standard MFRSR had issues, and we were able to provide the aerosol column data for the first 2 months of the campaign covering the summer flight phase of the deployment. Using these data, we were able to work with personnel at Pacific Northwest National Laboratory (PNNL) to retrieve not only aerosol optical depth (AOD), but single scattering albedo and asymmetry parameter, as well.

54 ENVIRONMENTAL SCIENCES↗

Constraining a spatially dependent rotation of the cosmic microwave background polarization

Following Kamionkowski (2008), a quadratic estimator of the rotation of the plane of polarization of the cosmic microwave background (CMB) is constructed. This statistic can estimate a spatially varying rotation angle {alpha}(n). We use this estimator to quantify the prospects of detecting such a rotation field with forthcoming experiments. For PLANCK and CMBPol experiments, we find that the estimator containing the product of the E and B components of the polarization field is the most sensitive. The variance of this EB estimator N(L) is roughly independent of the multipole L and is only weakly dependent on the instrumental beam. For FWHM of the beam size {theta}{sub fwhm}{approx}5{sup '}-50{sup '} and instrument noise {delta}{sub p}{approx}5-50 {mu}K-arcmin, the scaling of variance N(L) can be fitted by a power law N(L)=3.3x10{sup -7}{delta}{sub p}{sup 2}{theta}{sub fwhm}{sup 1.3} deg{sup 2}. For small instrumental noise {delta}{sub p}{<=}5 {mu}K-arcmin, the lensing B modes become important, saturating the variance to {approx}10{sup -6} deg{sup 2} even for an ideal experiment. Upcoming experiments like PLANCK will be able to detect a power spectrum of the rotation angle, C{sup {alpha}}{sup {alpha}}(L), as small as 0.01 deg{sup 2}, while futuristic experiments like CMBPol will be able to detect rotation angle power spectrum as small as 2.5x10{sup -5} deg{sup 2}. We discuss the implications of such constraints, both for the various physical effects that can rotate the polarization as photons travel from the last scattering surface as well as for constraints on instrumental systematics that can also lead to a spurious rotation signal. Rotation of the CMB polarization generates B modes which will act as contamination for the primordial B-mode detection. We discuss an application of our estimator to derotate the CMB to increase the sensitivity for the primordial B modes.

79 ASTRONOMY AND ASTROPHYSICS↗

THE THOMSON SURFACE. I. REALITY AND MYTH

The solar corona and heliosphere are visible via sunlight that is Thomson-scattered off free electrons and detected by coronagraphs and heliospheric imagers. It is well known that these instruments are most responsive to material at the 'Thomson surface', the sphere with a diameter passing through both the observer and the Sun. It is less well known that in fact the Thomson scattering efficiency is minimized on the Thomson surface. Unpolarized heliospheric imagers such as STEREO/HI are thus approximately equally responsive to material over more than a 90 Degree-Sign range of solar exit angles at each given position in the image plane. We call this range of angles the 'Thomson plateau'. We observe that heliospheric imagers are actually more sensitive to material far from the Thomson surface than close to it, at a fixed radius from the Sun. We review the theory of Thomson scattering as applied to heliospheric imaging, feature detection in the presence of background noise, geometry inference, and feature mass measurement. We show that feature detection is primarily limited by observing geometry and field of view, that the highest sensitivity for detection of density features is to objects close to the observer, that electron surface density inference is independent of geometry across the Thomson plateau, and that mass inference varies with observer distance in all geometries. We demonstrate the sensitivity results with a few examples of features detected by STEREO, far from the Thomson surface.

79 ASTRONOMY AND ASTROPHYSICS↗

A Mars orbital laser altimeter for rover trafficability: Instrument concept and science potential

Limited information on the types of geologic hazards (boulders, troughs, craters etc.) that will affect rover trafficability on Mars are available for the two Viking Lander sites, and there are no prospects for increasing this knowledge base in the near future. None of the instrument payloads on the upcoming Mars Observer or Soviet PHOBOS missions can directly measure surface obstacles on the scales of concern for rover safety (a few meters). Candidate instruments for the Soviet Mars 92 orbiter/balloon/rover mission such as balloon-borne stereo imaging, rover panoramic imaging, and orbital synthetic aperature imaging (SAR) are under discussion, but data from this mission may not be available for target areas of interest for the U.S. Mars Rover Sample Return (MRSR) mission. In an effort to determine how to directly measure the topography of surface obstacles that could affect rover trafficability on Mars, we are studying how to design a laser altimeter with extremely high spatial and vertical resolution that would be suitable for a future Mars Orbiter spacecraft (MRSR precursor or MRSR orbiter). This report discusses some of the design issues associated with such an instrument, gives examples of laser altimeter data collected for Mars analog terrains on Earth, and outlines the scientific potential of data that could be obtained with the system.

Garvin, J. B.↗

Self-Nulling Eddy Current Probe for Surface and Subsurface Flaw Detection

An eddy current probe which provides a null-signal in the presence of unflawed material without the need for any balancing circuitry has been developed at NASA Langley Research Center. Such a unique capability of the probe reduces set-up time, eliminates tester configuration errors, and decreases instrumentation requirements. The probe is highly sensitive to surface breaking fatigue cracks, and shows excellent resolution for the measurement of material thickness, including material loss due to corrosion damage. The presence of flaws in the material under test causes an increase in the extremely stable and reproducible output voltage of the probe. The design of the probe and some examples illustrating its flaw detection capabilities are presented.

Wincheski, B.↗

High Resolution Surface Science at Mars

The proposed mission would place a 2.4 m telescope in orbit around Mars with two focal plane instruments to obtain the highest resolution images and spectral maps of the surface to date (3-10x better than current). This investigation would make major contributions to all of the Mars Program Goals: life, climate, geology and preparation for human presence.

imaging↗

Water vapor profile retrievals from the HIRS/MSU sounder

The present physically based water vapor profile retrieval system for the HIRS/MSU sounding instrument is capable of producing accurate atmospheric and surface temperature retrievals, as well as accurate measurements of cloud fields on the basis of radiance values. In order to establish the extent of useful water vapor information in channels 8, 10, 11 and 12 of the HIRS instrument, studies have been conducted in which simultaneous temperature/humidity retrievals were performed on the basis of radiances simulated for clear and cloudy conditions.

Reuter, D.↗

Development of Pseudorandom Binary Arrays for Calibration of Surface Profile Metrology Tools

Optical metrology tools, especially for short wavelengths (extreme ultraviolet and x-ray), must cover a wide range of spatial frequencies from the very low, which affects figure, to the important mid-spatial frequencies and the high spatial frequency range, which produces undesirable scattering. A major difficulty in using surface profilometers arises due to the unknown point-spread function (PSF) of the instruments [G. D. Boreman, Modulation Transfer Function in Optical and Electro-Optical Systems (SPIE, Bellingham, WA, 2001)] that is responsible for distortion of the measured surface profile. Generally, the distortion due to the PSF is difficult to account for because the PSF is a complex function that comes to the measurement via the convolution operation, while the measured profile is described with a real function. Accounting for instrumental PSF becomes significantly simpler if the result of measurement of a profile is presented in the spatial frequency domain as a power spectral density (PSD) distribution [J. W. Goodman, Introduction to Fourier Optics, 3rd ed. (Roberts and Company, Englewood, CO, 2005)]. For example, measured PSD distributions provide a closed set of data necessary for three-dimensional calculations of scattering of light by the optical surfaces [E. L. Church et al., Opt. Eng. (Bellingham) 18, 125 (1979); J. C. Stover, Optical Scattering, 2nd ed. (SPIE Optical Engineering Press, Bellingham, WA, 1995)]. The distortion of the surface PSD distribution due to the PSF can be modeled with the modulation transfer function (MTF), which is defined over the spatial frequency bandwidth of the instrument. The measured PSD distribution can be presented as a product of the squared MTF and the ideal PSD distribution inherent for the system under test. Therefore, the instrumental MTF can be evaluated by comparing a measured PSD distribution of a known test surface with the corresponding ideal numerically simulated PSD. The square root of the ratio of the measured and simulated PSD distributions gives the MTF of the instrument. The applicability of the MTF concept to phase map measurements with optical interferometric microscopes needs to be experimentally verified as the optical tool and algorithms may introduce nonlinear artifacts into the process. In previous work [V. V. Yashchuk et al., Proc. SPIE 6704, 670408 (2007); Valeriy V. Yashchuk et al., Opt. Eng. (Bellingham) 47, 073602 (2008)] the instrumental MTF of a surface profiler was precisely measured using reference test surfaces based on binary pseudorandom (BPR) gratings. Here, the authors present results of fabricating and using two-dimensional (2D) BPR arrays that allow for a direct 2D calibration of the instrumental MTF. BPR sequences are widely used in engineering and communication applications such as global position systems and wireless communication protocols. The ideal BPR pattern has a flat 'white noise' response over the entire range of spatial frequencies of interest. The BPR array used here is based on the uniformly redundant array (URA) prescription [E. E. Fenimore and T. M. Cannon, Appl. Opt. 17, 337 (1978)] initially used for x-ray and gamma ray astronomy applications. The URA's superior imaging capability originates from the fact that its cyclical autocorrelation function very closely approximates a delta function, which produces a flat PSD. Three different size BPR array patterns were fabricated by electron beam lithography and induction coupled plasma etching of silicon. The basic size units were 200, 400, and 600 nm. Two different etch processes were used, CF{sub 4}/Ar and HBr, which resulted in undercut and vertical sidewall profiles, respectively. The 2D BPR arrays were used as standard test surfaces for MTF calibration of the MicroMap{trademark}-570 interferometric microscope using all available objectives. The MicroMap{trademark}-570 interferometric microscope uses incoherent illumination from a tungsten filament source and common path modulated phase shifting interference to produce a set of interferograms detected on a change coupled device. Mathematical algorithms applied to the datasets yield the surface phase map. The HBr etched two-dimensional BPR arrays have proven to be a very effective calibration standard making possible direct calibration corrections without the need of additional calculation considerations, while departures from the ideal vertical sidewall require an additional correction term for the CF{sub 4}/Ar etched samples [Samuel K. Barber et al., Abstract to Optics and Photonics 2009: Optical Engineering and Applications Symposium, San Diego, CA, 2-6 August 2009]. Initial surface roughness of low cost 'prime' wafers limits low magnification calibration but should not be a limitation if better polished samples are used.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Final Technical Report for DE-SC0008502

This work led to the development of an algorithm to retrieve cloud microphysical properties (optical depth and effective particle size) form shortwave spectral radiometric irradiance measured at the earth surface in the wavelength interval 1000-1600 nm. Recent instruments such as the ARM Program’s Shortwave Array Spectrometer (SAS) can record irradiance spectra in cadences as short as one minute, providing valuable information about time evolution of cloud properties involved with formation, precipitation and dissipation. A primary advantage of shortwave spectral measurements over the middle-infrared is that cloud properties can be retrieved over a much larger range in liquid water path (LWP), as the instrument is measuring irradiance transmitted through cloud. In the middle infrared, a cloud behaves as a blackbody for optical depths larger than approximately five, and for larger LWP surface longwave spectral measurements are insensitive to cloud microphysics. Research supported by this award has demonstrated the viability of the retrieval technique and the utility of high time resolution spectral measurements (Lubin et al. 2018a; Wilson et al. 2018).

47 OTHER INSTRUMENTATION↗

Design and Execution of the Hypersonic Inflatable Aerodynamic Decelerator Large-Article Wind Tunnel Experiment

The testing of 3- and 6-meter diameter Hypersonic Inflatable Aerodynamic Decelerator (HIAD) test articles was completed in the National Full-Scale Aerodynamics Complex 40 ft x 80 ft Wind Tunnel test section. Both models were stacked tori, constructed as 60 degree half-angle sphere cones. The 3-meter HIAD was tested in two configurations. The first 3-meter configuration utilized an instrumented flexible aerodynamic skin covering the inflatable aeroshell surface, while the second configuration employed a flight-like flexible thermal protection system. The 6-meter HIAD was tested in two structural configurations (with and without an aft-mounted stiffening torus near the shoulder), both utilizing an instrumented aerodynamic skin.

Cassell, Alan M.↗

1-Watt Radioisotope Power System for Small Spacecraft

A variety of mission concepts have been studied by NASA and the U. S. Department of Energy that would utilize low power Radioisotope Power Systems (RPS) for small probes, landers, rovers, and communication repeaters. These missions would contain science measuring instruments that could be distributed across planetary surfaces for operation in temporarily or permanently shadowed regions. High efficiency dynamic RPS could be mission enabling for science measurements on the moon, such as collecting real-time, event-based, or cumulative space radiation measurements including primary galactic cosmic rays (GCR), solar particle events (SPE), and secondary particles liberated during atmospheric and/or surface reactions. Small RPS would use fractional versions of the General Purpose Heat Source (GPHS) or Light Weight Radioisotope Heater Units (LWRHU), to heat the power conversion technologies. Capable of three to four times higher conversion efficiency than static technologies, dynamic RPS would provide an equal amount of power using less fuel or more power using an equal amount of fuel. Providing spacecraft with more power could decrease duty cycling of basic functions and increase the quality and abundance of science data. Low power Stirling convertors are being developed at NASA Glenn Research Center (GRC) to provide future micro spacecraft with electrical power by converting heat from one or more LWRHUs. An initial concept would convert eight Watts of heat to one Watt of electrical power output for science instruments and communication. The initial design, called Small Stirling Technology Exploration Power (smallSTEP), is 11 cm diameter X 32 cm long, weighs around 3 kg, and could be used to charge batteries or capacitors for higher power burst usage. Development of the 1-watt RPS includes maturation of a Stirling engine and linear alternator, an electronics controller, and an evacuated metal foil insulation package. Test hardware and facilities are being prepared for initial demonstration of the subassemblies in a laboratory environment.

Wilson, Scott↗

Systems and methods for analyzing liquids under vacuum

Systems and methods for supporting a liquid against a vacuum pressure in a chamber can enable analysis of the liquid surface using vacuum-based chemical analysis instruments. No electrical or fluid connections are required to pass through the chamber walls. The systems can include a reservoir, a pump, and a liquid flow path. The reservoir contains a liquid-phase sample. The pump drives flow of the sample from the reservoir, through the liquid flow path, and back to the reservoir. The flow of the sample is not substantially driven by a differential between pressures inside and outside of the liquid flow path. An aperture in the liquid flow path exposes a stable portion of the liquid-phase sample to the vacuum pressure within the chamber. The radius, or size, of the aperture is less than or equal to a critical value required to support a meniscus of the liquid-phase sample by surface tension.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Remote sensing of Earth's atmosphere and surface using a digital array scanned interferometer: A new type of imaging spectrometer

The capabilities of the digital array scanned interferometer (DASI) class of instruments for measuring terrestrial radiation fields over the visible to mid-infrared are evaluated. DASI's are capable of high throughput, sensitivity and spectral resolution and have the potential for field-of-view spatial discrimination (an imaging spectrometer). The simplicity of design and operation of DASI's make them particularly suitable for field and airborne platform based remote sensing. The long term objective is to produce a versatile field instrument which may be applied toward a variety of atmospheric and surface studies. The operation of DASI and its advantages over other spectrometers are discussed.

Hammer, Philip D.↗

Vertical Profiles of Aerosol Optical Properties Over Central Illinois and Comparison with Surface and Satellite Measurements

Between June 2006 and September 2009, an instrumented light aircraft measured over 400 vertical profiles of aerosol and trace gas properties over eastern and central Illinois. The primary objectives of this program were to (1) measure the in situ aerosol properties and determine their vertical and temporal variability and (2) relate these aircraft measurements to concurrent surface and satellite measurements. Underflights of the CALIPSO satellite show reasonable agreement in a majority of retrieved profiles between aircraft-measured extinction at 532 nm (adjusted to ambient relative humidity) and CALIPSO-retrieved extinction, and suggest that routine aircraft profiling programs can be used to better understand and validate satellite retrieval algorithms. CALIPSO tended to overestimate the aerosol extinction at this location in some boundary layer flight segments when scattered or broken clouds were present, which could be related to problems with CALIPSO cloud screening methods. The in situ aircraft-collected aerosol data suggest extinction thresholds for the likelihood of aerosol layers being detected by the CALIOP lidar. These statistical data offer guidance as to the likelihood of CALIPSO's ability to retrieve aerosol extinction at various locations around the globe.

Sheridan P. J.↗

Effect of the surface on the secondary structure of soft landed peptide ions

Ion soft landing (SL) enables highly selective modification of substrates for applications in materials science, nanotechnology and biology. Our previous study showed that SL can be used for preparation of conformation-selected peptide arrays. Here we present a first study of the effect of the surface on the secondary structures of peptides soft-landed onto self-assembled monolayer surfaces (SAMs). Conformations of soft-landed peptide ions were examined using the newly constructed instrument that enables in situ infrared reflection absorption spectroscopy (IRRAS) characterization of surfaces during and after ion deposition. Polyalanine peptides, Ac-AnK and Ac-KAn (n=7, 15), that have been extensively studied both in solution and in the gas phase were used as model systems in this study. We demonstrate that physical and chemical properties of SAM surfaces have a strong effect on the conformations of soft-landed peptides ions. For example, deposition of the α-helical [Ac-A15K+H]+ ion on the CH3-terminated (HSAM) surface results in immobilization of both the α- and 310-helical conformations. In contrast, a significant fraction of Ac-A15K molecules are present in the β-sheet conformation on the CF3- (FSAM) and COOH-terminated (COOH-SAM) surfaces. We show that the kinetic energy of the polyalanine ion, the charge, and the initial conformation have only a minor effect on the conformation of deposited species suggesting that the interaction between the molecule and the surface plays a major role in determining the secondary structures of immobilized polyalanines. This study demonstrates that SL of mass-selected ions can be utilized for obtaining fundamental understanding of the intrinsic properties of biomolecules and surfaces responsible for conformational changes upon adsorption.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Exploring the Martian Highlands using a Rover-Deployed Ground Penetrating Radar

The Martian highlands record a long and often complex history of geologic activity that has shaped the planet over time. Results of geologic mapping and new data from the Mars Global Surveyor spacecraft reveal layered surfaces created by multiple processes that are often mantled by eolian deposits. Knowledge of the near-surface stratigraphy as it relates to evolution of surface morphology will provide critical context for interpreting rover/lander remote sensing data and for defining the geologic setting of a highland lander. Rover-deployed ground penetrating radar (GPR) can directly measure the range and character of in situ radar properties, thereby helping to constrain near-surface geology and structure. As is the case for most remote sensing instruments, a GPR may not detect water unambiguously on Mars. Nevertheless, any local, near-surface occurrence of liquid water will lead to large, easily detected dielectric contrasts. Moreover, definition of stratigraphy and setting will help in evaluating the history of aqueous activity and where any water might occur and be accessible. GPR data can also be used to infer the degree of any post-depositional pedogenic alteration or weathering, thereby enabling assessment of pristine versus secondary morphology. Most importantly perhaps, GPR can provide critical context for other rover and orbital instruments/data sets. Hence, rover-deployment of a GPR deployment should enable 3-D mapping of local stratigraphy and could guide subsurface sampling.

Grant, J. A.↗

Sub-pixel Spatial Resolution Micro-roughness Measurements with Interlaced Stitching

In this paper we describe a method to increase the spatial resolution of surface micro-roughness measurements. As the surface specifications for precision optics become more demanding, the metrology instruments must cover a broad spatial frequency range. Generally, multiple instruments are used to cover the full range of the specifications. For example, a Fizeau interferometer would be used to test low spatial frequency surface errors, a white light interferometer would be used for mid spatial frequency errors, and an AFM would be used for high spatial frequency errors. For some precision optics, three instruments would be necessary. However, in many applications, an increase in the spatial resolution of a metrology instrument could negate the need for multiple instruments. A solution to increase the spatial resolution of micro-roughness measurements obtained using white light interferometry with "interlaced stitching" will be presented. In "interlaced stitching", multiple interferometric measurements are made as the optic under test (or the CCD array) is laterally shifted at sub-pixel increments. The measurements are then combined to construct a measurement with higher spatial resolution. Initial results obtained while implementing a similar process used to increase the spatial resolution of measurements made with a commercially available Fizeau interferometer will be presented.

Mooney, James T.↗

TPSAS-NF1676L-33873-DND

NOAA's National Air Quality Forecasting Capability (NAQFC) model provides 48-hour forecast of surface ozone and other atmospheric constituents serving as the nation's key tool actively used by regulatory professionals in assessing air quality events and the issuance of public air quality alerts. NAQFC incorporates input meteorology from North American Mesoscale Model (NAM) at 12 km horizontal resolution that is coupled to the Community Multi-scale Air Quality Model (CMAQ) to predict emissions, tropospheric gas and aerosol chemistry, and related deposition and removal processes. The NAQFC forecast simulations contain 35 steps in altitude, with about one third of these in a typical afternoon daytime boundary layer (0-1.5 km). While several studies have been conducted comparing NAQFC predictions to surface observations, investigations comparing the vertical distribution to observations remain limited. Vertical comparisons are needed in order to fully assess forecast model behavior and atmospheric mixing conditions leading to the formation of ozone at the surface. The Tropospheric Ozone Lidar Network (TOLNet) instruments provide a unique observational capability in this regard, as ozone vertical measurements can be directly compared to models, such as NAQFC, and provide additional insight into atmospheric processes and enhance forecast capabilities. In this study, we utilize multiple TOLNet lidar observations obtained during the Ozone Water Land Environmental Transition Studies (OWLETS-2017 & OWLETS-2018) and the Long Island Sound Tropospheric Ozone Study (LISTOS-2018) to compare with NAQFC vertical predictions of ozone. These campaigns took place at different coastal locations along the US East coast with each campaign having multiple TOLNet lidars present, providing a unique opportunity to examine vertical structure of ozone in regions with complex water-land boundaries. Preliminary comparison results will be presented on ozone temporal and vertical differences between NAQFC and the TOLNet lidars along with example case studies to illustrate insights into boundary layer and surface processes of trace gases.