Search NASA⌕ Search

SEARCH · Search NASA

Results for “surface instruments”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,423 records · Page 79

Nuclear fusion powered Titan aircraft

This paper discusses a system for Titan exploration enabled by nuclear fusion power. Titan is one of the most interesting locations in the solar system with a thick atmosphere, surface oceans, under-ice oceans and complex terrain. This paper provides a conceptual design of a fusion-powered system to explore many parts of Titan and enable the use of high-power instruments. The design includes a fusion-powered orbital transfer vehicle and an electric Titan science aircraft. A Direct Fusion Drive (DFD) propulsive engine could bring a sizable spacecraft to Titan orbit in less than two years. A second fusion reactor, configured as a closed-loop power generator, would be used for an electric Titan science aircraft. Both reactors are based on the Princeton Field-Reversed Configuration (PFRC) concept which combines an FRC with a magnetic mirror. PFRC uses a novel radio-frequency plasma heating system and deuterium-helium-3 fuel. A lower temperature plasma flows around the closed-field FRC region removing the fusion products. In the DFD propulsive configuration, this secondary flow permits direct and variable thrust and exhaust velocity. The science aircraft would do a powered entry to Titan and then have the capability to fly anywhere on the moon at subsonic speeds. The DFD-powered transfer vehicle would allow the in-orbit transfer stage to change inclination as needed to cover different areas of the surface.

33 ADVANCED PROPULSION SYSTEMS↗

Point source polarimetry with the Gemini Planet Imager: Sensitivity characterization with T5.5 dwarf companion HD 19467 B

Detecting polarized light from self-luminous exoplanets has the potential to provide key information about rotation, surface gravity, cloud grain size, and cloud coverage. While field brown dwarfs with detected polarized emission are common, no exoplanet or substellar companion has yet been detected in polarized light. With the advent of high contrast imaging spectro-polarimeters such as GPI and SPHERE, such a detection may now be possible with careful treatment of instrumental polarization. In this paper, we present 28 minutes of H-band GPI polarimetric observations of the benchmark T5.5 companion HD 19467 B. We detect no polarization signal from the target, and place an upper limit on the degree of linear polarization of p{sub CL99.73%}⩽2.4%. We discuss our results in the context of T dwarf cloud models and photometric variability.

79 ASTRONOMY AND ASTROPHYSICS↗

Preliminary design of laser-induced breakdown spectroscopy for proto-Material Plasma Exposure eXperiment

Laser-induced breakdown spectroscopy (LIBS) is a technique for measuring surface matter composition. LIBS is performed by focusing laser radiation onto a target surface, ablating the surface, forming a plasma, and analyzing the light produced. LIBS surface analysis is a possible diagnostic for characterizing plasma-facing materials in ITER. Oak Ridge National Laboratory has enabled the initial installation of a laser-induced breakdown spectroscopy diagnostic on the prototype Material-Plasma Exposure eXperiment (Proto-MPEX), which strives to mimic the conditions found at the surface of the ITER divertor. This paper will discuss the LIBS implementation on Proto-MPEX, preliminary design of the fiber optic LIBS collection probe, and the expected results.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Overview of Observed and Measured Physical and Geophysical Effects of Historic Underground Nuclear Tests at the Nevada National Security Site

As detailed in a variety of sources (e.g., Allen et al. [1997]; Grasso [2001]), underground explosions can leave visible evidence of their occurrence in the geologic medium. The appearance and extent of the effects visible at the surface depend on a variety of factors, including scaled depth of burial (SDOB; actual depth of burial divided by the cube root of the yield of the explosion) and geologic medium characteristics. Surface effects were routinely documented for most of the underground nuclear explosions (UNEs) conducted at the former Nevada Test Site (now Nevada National Nuclear Site) and spatial data for them are available to the public (Grasso, 2001). Other effects, including collapse chimneys, glass-lined surfaces indicative of the initial explosion cavity, and shock damage to the medium, have also been characterized in various ways. These studies were done for a variety of purposes such as determining how closely UNEs could safely be positioned to conserve testing “real estate,” as input for containment design, to obtain survivability data for various types of equipment and instrumentation, and to understand device performance. Here we present examples of various mapped and measured explosion effects for the two main types of historical UNEs conducted at the NNSS, those in vertical shafts and those in horizontal tunnels. We do not include here cratering tests, which were shots conducted at shallow SDOBs for the purpose of creating a surface excavation.

explosion effects, Nevada National Security Site↗

Oceanic ambient noise as a background to acoustic neutrino detection

Ambient noise measured in the deep ocean is studied in the context of a search for signals from ultrahigh-energy cosmic ray neutrinos. The spectral shape of the noise at the relevant high frequencies is found to be very stable for an extensive data set collected over several months from 49 hydrophones mounted near the bottom of the ocean at {approx}1600 m depth. The slopes of the ambient noise spectra above 15 kHz are found to roll off faster than the -6 dB/octave seen in Knudsen spectra. A model attributing the source to a uniform distribution of surface noise that includes frequency-dependent absorption at large depth is found to fit the data well up to 25 kHz. This depth-dependent model should therefore be used in analysis methods of acoustic neutrino pulse detection that require the expected noise spectra.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Nanoscale Perspectives of Metal Degradation via In Situ Atom Probe Tomography

Abstract We report a unique in situ instrument development effort dedicated to studying gas/solid interactions relevant to heterogeneous catalysis and early stages of oxidation of materials via atom probe tomography and microscopy (APM). An in situ reactor cell, similar in concept to other reports, has been developed to expose nanoscale volumes of material to reactive gas environments, in which temperature, pressure, and gas chemistry are well controlled. We demonstrate that the combination of this reactor cell with APM techniques can aid in building a better mechanistic understanding of resultant composition and surface and subsurface structure changes accompanying gas/surface reactions in metal and metal alloy systems through a series of case studies: O 2 /Rh, O 2 /Co, and O 2 /Zircaloy-4. In addition, the basis of a novel operando mode of analysis within an atom probe instrument is also reported. The work presented here supports the implementation of APM techniques dedicated to atomic to near-atomically resolved gas/surface interaction studies of materials broadly relevant to heterogeneous catalysis and oxidation.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Note: Dynamic strain field mapping with synchrotron X-ray digital image correlation

We present a dynamic strain field mapping method based on synchrotron X-ray digital image correlation (XDIC). Synchrotron X-ray sources are advantageous for imaging with exceptional spatial and temporal resolutions, and X-ray speckles can be produced either from surface roughness or internal inhomogeneities. Combining speckled X-ray imaging with DIC allows one to map strain fields with high resolutions. Based on experiments on void growth in Al and deformation of a granular material during Kolsky bar/gas gun loading at the Advanced Photon Source beamline 32ID, we demonstrate the feasibility of dynamic XDIC. XDIC is particularly useful for dynamic, in-volume, measurements on opaque materials under high strain-rate, large, deformation.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Position-sensitive detection of ultracold neutrons with an imaging camera and its implications to spectroscopy

Position-sensitive detection of ultracold neutrons (UCNs) is demonstrated using an imaging charge-coupled device (CCD) camera. A spatial resolution less than 15μm has been achieved, which is equivalent to a UCN energy resolution below 2 pico-electron-volts through the relation δE=m 0 gδx. Here, the symbols δE, δx, m 0 and g are the energy resolution, the spatial resolution, the neutron rest mass and the gravitational acceleration, respectively. A multilayer surface convertor described previously is used to capture UCNs and then emits visible light for CCD imaging. Particle identification and noise rejection are discussed through the use of light intensity profile analysis. As a result, this method allows different types of UCN spectroscopy and other applications.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Modern methods for investigating functional surfaces of advanced materials by mechanical contact testing

Modern methods for determining the hardness, Young's modulus, elastic recovery, adhesive/cohesive strength, friction coefficient, and wear resistance of thin films, coatings, multilayer materials, and bulk materials are considered. The experimental data obtained in instrumented indentation, instrumented scratching, and tribological tests of nanostructured and quasicrystalline coatings and composite materials are analyzed. It is noted that the elastic recovery of a number of advanced materials is higher than the elastic recovery of metal alloys by a factor of 2-3. The coefficients of sliding friction of sintered samples and thin films containing Al-Cu-Fe quasicrystals are found to be relatively low. An increase in the fraction of quasicrystalline particles to 30% in composites with an aluminum matrix leads to an increase in the wear resistance.

36 MATERIALS SCIENCE↗

Light scattering by a rough surface of human skin. 1. The luminance factor of reflected light

Based on the analytical solution of Maxwell's equations, we have studied the angular structure of the luminance factor of light reflected by the rough skin surface with large-scale relief elements, illuminated by a directed radiation beam incident at an arbitrary angle inside or outside the medium. The parameters of the surface inhomogeneities are typical of human skin. The calculated angular dependences are interpreted from the point of view of the angular distribution function of micro areas. The results obtained can be used for solving direct and inverse problems in biomedical optics, in particular for determining the depth of light penetration into a biological tissue, for studying the light action spectra on tissue chromophores under the in vivo conditions, for developing diagnostic methods of structural and biophysical parameters of a medium, and for optimising the mechanisms of interaction of light with biological tissues under their noninvasive irradiation through skin. (biomedical optics)

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Final LDRD report : development of sample preparation methods for ChIPMA-based imaging mass spectrometry of tissue samples.

The objective of this short-term LDRD project was to acquire the tools needed to use our chemical imaging precision mass analyzer (ChIPMA) instrument to analyze tissue samples. This effort was an outgrowth of discussions with oncologists on the need to find the cellular origin of signals in mass spectra of serum samples, which provide biomarkers for ovarian cancer. The ultimate goal would be to collect chemical images of biopsy samples allowing the chemical images of diseased and nondiseased sections of a sample to be compared. The equipment needed to prepare tissue samples have been acquired and built. This equipment includes an cyro-ultramicrotome for preparing thin sections of samples and a coating unit. The coating unit uses an electrospray system to deposit small droplets of a UV-photo absorbing compound on the surface of the tissue samples. Both units are operational. The tissue sample must be coated with the organic compound to enable matrix assisted laser desorption/ionization (MALDI) and matrix enhanced secondary ion mass spectrometry (ME-SIMS) measurements with the ChIPMA instrument Initial plans to test the sample preparation using human tissue samples required development of administrative procedures beyond the scope of this LDRD. Hence, it was decided to make two types of measurements: (1) Testing the spatial resolution of ME-SIMS by preparing a substrate coated with a mixture of an organic matrix and a bio standard and etching a defined pattern in the coating using a liquid metal ion beam, and (2) preparing and imaging C. elegans worms. Difficulties arose in sectioning the C. elegans for analysis and funds and time to overcome these difficulties were not available in this project. The facilities are now available for preparing biological samples for analysis with the ChIPMA instrument. Some further investment of time and resources in sample preparation should make this a useful tool for chemical imaging applications.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

X-ray photoemission analysis of chemically treated GaTe semiconductor surfaces for radiation detector applications

The surface of the layered III-VI chalcogenide semiconductor GaTe was subjected to various chemical treatments commonly used in device fabrication to determine the effect of the resulting microscopic surface composition on transport properties. Various mixtures of H{sub 3}PO{sub 4}:H{sub 2}O{sub 2}:H{sub 2}O were accessed and the treated surfaces were allowed to oxidize in air at ambient temperature. High-resolution core-level photoemission measurements were used to evaluate the subsequent chemistry of the chemically treated surfaces. Metal electrodes were created on laminar (cleaved) and nonlaminar (cut and polished) GaTe surfaces followed by chemical surface treatment and the current versus voltage characteristics were measured. The measurements were correlated to understand the effect of surface chemistry on the electronic structure at these surfaces with the goal of minimizing the surface leakage currents for radiation detector devices.

36 MATERIALS SCIENCE↗

Multi-channeled NbN superconducting single photon detectors (SSPDs) system with NbN meander nanowires

A superconducting single photon detector (SSPD) is promising candidate of the detector in a quantum key distribution (QKD) system, because of its low dark count and high speed repetition rate. We have developed the SSPD system cooled by a GM cryocooler. In this system, and the work surface can be cooled 2.95 K and up to 6 SSPDs can be installed. The active areas of SSPDs are 10x10 {mu}m{sup 2} or 20x20 {mu}m{sup 2}, and the system detection efficiency at dark count rate of 100 Hz reached 2.6% at a wavelength of 1550 nm.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Cu-doped AlN: A possible spinaligner at room-temperature grown by molecular beam epitaxy?

Cu-doped AlN was prepared by plasma assisted molecular beam epitaxy on C-plane sapphire substrates. The growth conditions were investigated for different Cu to Al flux ratios from 1.0% to 4.0%. The formation of Cu-Al alloys on the surface was observed for all doping level. In contrast to Cu-doped GaN, all samples showed diamagnetic behavior determined by SQUID measurements.

36 MATERIALS SCIENCE↗

Experimental investigation on the electrical contact behavior of rolling contact connector

Rolling contact connector (RCC) is a new technology utilized in high performance electric power transfer systems with one or more rotating interfaces, such as radars, satellites, wind generators, and medical computed tomography machines. Rolling contact components are used in the RCC instead of traditional sliding contacts to transfer electrical power and/or signal. Since the requirement of the power transmission is increasing in these years, the rolling electrical contact characteristics become more and more important for the long-life design of RCC. In this paper, a typical form of RCC is presented. A series of experimental work are carried out to investigate the rolling electrical contact characteristics during its lifetime. The influence of a variety of factors on the electrical contact degradation behavior of RCC is analyzed under both vacuum and air environment. Based on the surface morphology and elemental composition changes in the contact zone, which are assessed by field emission scanning electron microscope and confocal laser scanning microscope, the mechanism of rolling electrical contact degradation is discussed.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Holistic Interactions of Shallow Clouds, Aerosols, and Land-Ecosystems (HI-SCALE) Science Plan

Cumulus convection is an important component in the atmospheric radiation budget and hydrologic cycle over the Southern Great Plains and over many regions of the world, particularly during the summertime growing season when intense turbulence induced by surface radiation couples the land surface to clouds. Current convective cloud parameterizations contain uncertainties resulting in part from insufficient coincident data that couples cloud macrophysical and microphysical properties to inhomogeneities in boundary layer and aerosol properties. The Holistic Interactions of Shallow Clouds, Aerosols, and Land-Ecosystems (HI-SCALE) campaign is designed to provide a detailed set of measurements that are needed to obtain a more complete understanding of the life cycle of shallow clouds by coupling cloud macrophysical and microphysical properties to land surface properties, ecosystems, and aerosols. HI-SCALE consists of 2, 4-week intensive observational periods, one in the spring and the other in the late summer, to take advantage of different stages and distribution of “greenness” for various types of vegetation in the vicinity of the Atmospheric Radiation and Measurement (ARM) Climate Research Facility’s Southern Great Plains (SGP) site as well as aerosol properties that vary during the growing season. Most of the proposed instrumentation will be deployed on the ARM Aerial Facility (AAF) Gulfstream 1 (G-1) aircraft, including those that measure atmospheric turbulence, cloud water content and drop size distributions, aerosol precursor gases, aerosol chemical composition and size distributions, and cloud condensation nuclei concentrations. Routine ARM aerosol measurements made at the surface will be supplemented with aerosol microphysical properties measurements. The G-1 aircraft will complete transects over the SGP Central Facility at multiple altitudes within the boundary layer, within clouds, and above clouds.

Fast, JD↗

Mechanical Properties of Laser Heat Treated 6 mm Thick UHSS-Steel

In this work abrasion resistant (AR) steel with a sheet thickness of 6 mm was heat treated by a 4 kW Nd:YAG and a 4 kW Yb:Yag-laser, followed by self-quenching. In the delivered condition, test material blank (B27S) is water quenched from 920 deg. C. In this condition, fully martensitic microstructure provides excellent hardness of over 500 HB. The test material is referred to AR500 from now onwards. Laser heat treatment was carried out only on top surface of the AR500 sheet: the achieved maximum temperature in the cross-section varies as a function of the depth. Consequently, the microstructure and mechanical properties differ between the surfaces and the centre of the cross-section (layered microstructure). For better understanding, all layers were tested in tensile tests. For a wide heat treatment track, the laser beam was moved by scanning. Temperatures were measured using thermographic camera and thermocouples. Laser heat treated AR500 samples were tested in hardness tests and by air bending using a press brake machine. Microstructures were studied using a light microscope and FE-SEM/SEM-EBSD. At least three kind of microstructure layers were observed: 1) Dual-Phase ferritic/martensitic (T = A{sub C1}-A{sub C3}), 2) ferritic (T{approx}A{sub C3}) and 3) bainitic/martensitic (T>A{sub C3}).

36 MATERIALS SCIENCE↗