DCATT Dispersed Fringe Sensor (DFS) -- Modeling and Experiment with Transmissive Phase Plates
The alignment and phasing control of NGST's segment primary mirrors use images from the science camera instead of dedicated instruments.
SEARCH · Search NASA
Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.
Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.
The alignment and phasing control of NGST's segment primary mirrors use images from the science camera instead of dedicated instruments.
This article [Opt. Eng. 51, 011002 (2012)] was originally published on 8 February 2012 with an error in Eq. (13). The corrected equation appears below. The manuscript was corrected online on 15 February 2012. The article appears correctly in print.
No abstract available
As a requisite and key step in some gradient-based measurement techniques, the reconstruction of the shape, more generally the scalar potential, from the measured gradient data has been studied for many years. Here, in this work, three types of two-dimensional integration methods are compared under various conditions. The merits and drawbacks of each integration method are consequently revealed to provide suggestions in selection of a proper integration method for a particular application.
As a low cost, full-field three-dimensional shape measurement technique with high dynamic range, Phase Measuring Deflectometry (PMD) has been studied and improved to be a simple and effective manner to inspect specular reflecting surfaces. In this review, the fundamental principle and the basic concepts of PMD technique are introduced and followed by a brief overview of its key developments since it was first proposed. In addition, the similarities and differences compared with other related techniques are discussed to highlight the distinguishing features of the PMD technique. In conclusion, we will address the major challenges, the existing solutions and the remaining limitations in this technique to provide some suggestions for potential future investigations.
Not Available
Significant efforts are currently ongoing in X-ray imaging to provide multimodal imaging systems, targeting better sensitivity and specificity for both biomedical or non-destructive testing applications. Knowing the elemental composition of specific structures, such as breast microcalcifications in mammography, would help to differentiate malign and benign tumours. Standard X-ray Phase Contrast Imaging techniques provide only qualitative information on elements with similar absorption properties. However, their chemical composition can be determined from the measurement of the phase as it is directly related to the optical index of elemental materials. We will show new experimental results obtained with an X-ray phase imaging system based on a Hartmann mask. Early data treatment succeeded in retrieving both the real and imaginary parts of the refractive index. The system demonstrates the capability to discriminate materials based on elemental composition.
Numerical simulations of the current and future pulse intensity distributions at selected locations along the Far Experimental Hall, the hard X-ray section of the Linac Coherent Light Source (LCLS), are provided. Estimates are given for the pulse fluence, energy and size in and out of focus, taking into account effects due to the experimentally measured divergence of the X-ray beam, and measured figure errors of all X-ray optics in the beam path. Out-of-focus results are validated by comparison with experimental data. Previous work is expanded on, providing quantitatively correct predictions of the pulse intensity distribution. Numerical estimates in focus are particularly important given that the latter cannot be measured with direct imaging techniques due to detector damage. Finally, novel numerical estimates of improvements to the pulse intensity distribution expected as part of the on-going upgrade of the LCLS X-ray transport system are provided. As a result, we suggest how the new generation of X-ray optics to be installed would outperform the old one, satisfying the tight requirements imposed by X-ray free-electron laser facilities.
This paper presents a novel cantilevered liquid-nitrogen-cooled silicon mirror design for the first optic in a new soft X-ray beamline that is being developed as part of the Advanced Light Source Upgrade (ALS-U) (Lawrence Berkeley National Laboratory, USA). The beamline is optimized for photon energies between 400 and 1400 eV with full polarization control. Calculations indicate that, without correction, this design will achieve a Strehl ratio greater than 0.85 for the entire energy and polarization ranges of the beamline. With a correction achieved by moving the focus 7.5 mm upstream, the minimum Strehl ratio is 0.99. This design is currently the baseline plan for all new ALS-U insertion device beamlines.
The advent of X-ray multi-contrast imaging methods, providing absorption, phase, and dark-field images, holds tremendous promise for complementary and non-destructive visualization of inner structures within materials and bio-samples. However, the low efficiency in measuring and analyzing X-ray modulated patterns has hindered their application in high-resolution in situ imaging. In this work, the Enhanced Scanning Pattern-based Imaging Neural Network (ESPINNet) is introduced as a powerful tool for achieving high-speed, high-resolution quantitative imaging. ESPINNet is faster than correlation-based speckle tracking methods such as XSVT and UMPA, and provides a balanced performance in terms of resolution and speed for data collection by using fewer scanning images. In comparison with our previously developed neural network, ESPINNet introduces the capability to generate dark-field images, further enhancing its versatility. By leveraging scanning patterns, ESPINNet significantly improves resolution and measurement precision. Furthermore, its adaptability to various modulation patterns, including those produced by sandpaper, coded masks, or gratings, ensures broad applicability. These features enable real-time 2D and 3D multi-contrast imaging, positioning ESPINNet as a transformative solution for applications in materials science and biomedical research, particularly for high-speed and in situ measurements.
Coherent ptychographic imaging experiments often discard the majority of the flux from a light source to define the coherence of the illumination. Even when the coherent flux is sufficient, the stability required during an exposure is another important limiting factor. Partial coherence analysis can considerably reduce these limitations. A partially coherent illumination can often be written as the superposition of a single coherent illumination convolved with a separable translational kernel. This article proposes the gradient decomposition of the probe (GDP), a model that exploits translational kernel separability, coupling the variances of the kernel with the transverse coherence. An efficient first-order splitting algorithm ( GDP-ADMM ) for solving the proposed nonlinear optimization problem is described. Numerical experiments demonstrate the effectiveness of the proposed method with Gaussian and binary kernel functions in fly-scan measurements. Remarkably, GDP-ADMM using nanoprobes produces satisfactory results even when the ratio between the kernel width and the beam size is more than one, or when the distance between successive acquisitions is twice as large as the beam width.
Direct-drive fusion implosion experiments using the 60-beam OMEGA Laser System require ~1% rms uniformity on target. Measurements from laser diagnostics indicate that beam-to-beam power variation has been sufficiently reduced such that the uniformity nearly meets this requirement; however, experimental results suggest otherwise. To better understand this discrepancy, a full-beam-in-tank diagnostic has been developed to characterize the on-shot, full-energy focal spot of a single beam inside the target chamber using a small sample of the beam from the final optic assembly. In this paper, we describe the diagnostic and present the results of commissioning experiments.
Abstract We develop an automatic and objective method to measure and correct residual aberrations in atomic-resolution HRTEM complex exit waves for crystalline samples aligned along a low-index zone axis. Our method uses the approximate rotational point symmetry of a column of atoms or single atom to iteratively calculate a best-fit numerical phase plate for this symmetry condition, and does not require information about the sample thickness or precise structure. We apply our method to two experimental focal series reconstructions, imaging a β-Si 3 N 4 wedge with O and N doping, and a single-layer graphene grain boundary. We use peak and lattice fitting to evaluate the precision of the corrected exit waves. We also apply our method to the exit wave of a Si wedge retrieved by off-axis electron holography. In all cases, the software correction of the residual aberration function improves the accuracy of the measured exit waves.
Not Available
Explore the source record for details and available documents.
Explore the source record for details and available documents.
NASA Mirror Technology Days Huntsville, Alabama, USA.
Dispersed Fringe Sensing (DFS) is an efficient and robust method for coarse phasing of segmented primary mirrors (from a quarter of a wavelength up to the depth of focus of a single segment, typically several tens of microns). Unlike phasing techniques currently used for ground-based segmented telescopes; this makes it particularly well-suited to the phasing of space-borne segmented telescopes, such as the James Webb Space Telescopes (JWST). In this work we validate DFS by using it to measure the pistons of the segments of one of the Keck telescopes; the results agree with those of the Shack-Hartmann based phasing scheme currently in use at Keck to within 2% over a range of initial piston errors of +/-16 microns.