Search NASA⌕ Search

SEARCH · Search NASA

Results for “2D SCANS”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 145 records · Page 8

SU-E-J-90: MRI-Based Treatment Simulation and Patient Setup for Radiation Therapy of Brain Cancer

Purpose: Traditional radiation therapy of cancer is heavily dependent on CT. CT provides excellent depiction of the bones but lacks good soft tissue contrast, which makes contouring difficult. Often, MRIs are fused with CT to take advantage of its superior soft tissue contrast. Such an approach has drawbacks. It is desirable to perform treatment simulation entirely based on MRI. To achieve MR-based simulation for radiation therapy, bone imaging is an important challenge because of the low MR signal intensity from bone due to its ultra-short T2 and T1, which presents difficulty for both dose calculation and patient setup in terms of digitally reconstructed radiograph (DRR) generation. Current solutions will either require manual bone contouring or multiple MR scans. We present a technique to generate DRR using MRI with an Ultra Short Echo Time (UTE) sequence which is applicable to both OBI and ExacTrac 2D patient setup. Methods: Seven brain cancer patients were scanned at 1.5 Tesla using a radial UTE sequence. The sequence acquires two images at two different echo times. The two images were processed using in-house software. The resultant bone images were subsequently loaded into commercial systems to generate DRRs. Simulation and patient clinical on-board images were used to evaluate 2D patient setup with MRI-DRRs. Results: The majority bones are well visualized in all patients. The fused image of patient CT with the MR bone image demonstrates the accuracy of automatic bone identification using our technique. The generated DRR is of good quality. Accuracy of 2D patient setup by using MRI-DRR is comparable to CT-based 2D patient setup. Conclusion: This study shows the potential of DRR generation with single MR sequence. Further work will be needed on MR sequence development and post-processing procedure to achieve robust MR bone imaging for other human sites in addition to brain.

60 APPLIED LIFE SCIENCES↗

Probing the Role of Interlayer Coupling and Coulomb Interactions on Electronic Structure in Few-Layer MoSe 2 Nanostructures

Despite the weak nature of interlayer forces in transition metal dichalcogenide (TMD) materials, their properties are highly dependent on the number of layers in the few-layer two-dimensional (2D) limit. Here, we present a combined scanning tunneling microscopy/spectroscopy and GW theoretical study of the electronic structure of high quality single- and few-layer MoSe2 grown on bilayer graphene. We find that the electronic (quasiparticle) bandgap, a fundamental parameter for transport and optical phenomena, decreases by nearly one electronvolt when going from one layer to three due to interlayer coupling and screening effects. Our results paint a clear picture of the evolution of the electronic wave function hybridization in the valleys of both the valence and conduction bands as the number of layers is changed. This demonstrates the importance of layer number and electron-electron interactions on van der Waals heterostructures and helps to clarify how their electronic properties might be tuned in future 2D nanodevices.

77 NANOSCIENCE AND NANOTECHNOLOGY↗

System and method for identifying objects of interest in images based on likelihood map decluttering

An automatic threat recognition system and method is disclosed for scanning the x-ray CT image of an article to identify the objects of interest (OOIs) contained within the article, which are otherwise not always quickly apparent or discernable to an individual. The system uses a computer to receive information from two-dimensional (2D) image slices from a reconstructed computed tomography (CT) scan image and to produce a plurality of voxels for each slice of the 2D image. The computer analyzes the voxels to create a likelihood map (LM) representing likelihoods that voxels making up the CT image are associated with a material of interest (MOI). The computer further analyzes the LM to construct neighborhoods of voxels within the LM, and classifies each voxel neighborhood based on its features, thereby decluttering the LM to facilitate the process of connecting voxels of a like MOI together to form segments. The computer classifies each candidate segment based on its features, thereby identifying those segments that correspond to objects of interest.

Paglieroni, David W.↗

Template-based CTA to x-ray angio rigid registration of coronary arteries in frequency domain with automatic x-ray segmentation

Purpose: A key challenge for image guided coronary interventions is accurate and absolutely robust image registration bringing together preinterventional information extracted from a three-dimensional (3D) patient scan and live interventional image information. In this paper, the authors present a novel scheme for 3D to two-dimensional (2D) rigid registration of coronary arteries extracted from preoperative image scan (3D) and a single segmented intraoperative x-ray angio frame in frequency and spatial domains for real-time angiography interventions by C-arm fluoroscopy.Methods: Most existing rigid registration approaches require a close initialization due to the abundance of local minima and high complexity of search algorithms. The authors' method eliminates this requirement by transforming the projections into translation-invariant Fourier domain for estimating the 3D pose. For 3D rotation recovery, template Digitally Reconstructed Radiographs (DRR) as candidate poses of 3D vessels of segmented computed tomography angiography are produced by rotating the camera (image intensifier) around the DICOM angle values with a specific range as in C-arm setup. The authors have compared the 3D poses of template DRRs with the segmented x-ray after equalizing the scales in three domains, namely, Fourier magnitude, Fourier phase, and Fourier polar. The best rotation pose candidate was chosen by one of the highest similarity measures returned by the methods in these domains. It has been noted in literature that frequency domain methods are robust against noise and occlusion which was also validated by the authors' results. 3D translation of the volume was then recovered by distance-map based BFGS optimization well suited to convex structure of the authors' objective function without local minima due to distance maps. A novel automatic x-ray vessel segmentation was also performed in this study.Results: Final results were evaluated in 2D projection space for patient data; and with ground truth values and landmark distances for the images acquired with a solid phantom vessel. Results validate that rotation recovery in frequency domain is robust against differences in segmentations in two modalities. Distance-map translation is successful in aligning coronary trees with highest possible overlap.Conclusions: Numerical and qualitative results show that single view rigid alignment in projection space is successful. This work can be extended with multiple views to resolve depth ambiguity and with deformable registration to account for nonrigid motion in patient data.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Reshaping, Intermixing, and Coarsening for Metallic Nanocrystals: Nonequilibrium Statistical Mechanical and Coarse-Grained Modeling

Self-assembly of supported 2D or 3D nanocrystals (NCs) by vacuum deposition and of 3D NCs by solution-phase synthesis (with possible subsequent transfer to a support) produces intrinsically nonequilibrium systems. Individual NCs can have far-from-equilibrium shapes and composition profiles. The free energy of NC ensembles is lowered by coarsening which can involve Ostwald ripening or Smoluchowski ripening (NC diffusion and coalescence). Preservation of individual NC structure and inhibition of coarsening are key, e.g., for avoiding catalyst degradation. This review focuses on postsynthesis evolution of metallic NCs. Atomistic-level modeling typically utilizes stochastic lattice-gas models to access appropriate time and length scales. However, predictive modeling requires incorporation of realistic rates for relaxation mechanisms, e.g., periphery diffusion and intermixing, in numerous local environments (rather than the use of generic prescriptions). Alternative coarse-grained modeling must also incorporate appropriate mechanisms and kinetics. At the level of individual NCs, we present analyses of reshaping, including sintering and pinch-off, and of compositional evolution in a vacuum environment. Here, we also discuss modeling of coarsening including diffusion and decay of individual NCs and unconventional coarsening processes. We describe high-level modeling integrated with scanning tunneling microscopy (STM) studies for supported 2D epitaxial nanoclusters and developments in modeling for 3D NCs motivated by in situ transmission electron microscopy (TEM) studies.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

MO-FG-202-03: Efficient Data Collection of Continuous 2D and Discrete Relative Dosimetric Data for Annual LINAC QA Using TrueBeam Developer Mode and a 1D Scanning Tank

Purpose: To develop a method to exploit real-time dynamic machine and couch parameter control during linear accelerator (LINAC) beam delivery to facilitate efficient performance of TG-142 suggested, Annual LINAC QA tests. Methods: Varian’s TrueBeam Developer Mode (Varian Medical Systems, Palo Alto, CA) facilitates control of Varian’s TrueBeam LINAC via instructions provided in Extensible Markup Language (XML) files. This allows machine and couch parameters to be varied dynamically, in real-time, during beam delivery. Custom XML files were created to allow for the collection of (1) continuous Tissue Maximum Ratios (TMRs), (2) beam profiles, and (3) continuous output factors using a 1D-scanning tank. TMRs were acquired by orienting an ionization chamber (IC) at isocenter (depth=25cm) and synchronizing a depth scan towards the water surface while lowering the couch at 1mm/s. For beam profiles, the couch was driven laterally and longitudinally while logging IC electrometer readings. Output factors (OFs) where collected by continually varying field sizes (4×4 to 30×30-cm{sup 2}) at a constant speed of 6.66 mm/s. To validate measurements, comparisons were made to data collected using traditional methods (e.g. 1D or 3D tank). Results: All data collecting using the proposed methods agreed with traditionally collected data (TMRs within 1%, OFs within 0.5% and beam profile agreement within 1% / 1mm) while taking less time to collect (factor of approximately 1/10) and with a finer sample resolution. Conclusion: TrueBeam developer mode facilitates collection of continuous data with the same accuracy as traditionally collected data with a finer resolution in less time. Results demonstrate an order of magnitude increase in sampled resolution and an order of magnitude reduction in collection time compared to traditional acquisition methods (e.g. 3D scanning tank). We are currently extending this approach to perform other TG-142 tasks.

61 RADIATION PROTECTION AND DOSIMETRY↗

Designing Targets for Elective Nodal Irradiation in Lung Cancer Radiotherapy: A Planning Study

Purpose: To assess doses received by mediastinal and hilar lymph node stations (LNS) delineated according to published recommendations when 'standard' two-dimensional (2D) elective fields are applied and to assess doses to critical structures when fields are designed using 2D and three-dimensional (3D) treatment planning for elective irradiation. Methods and Materials: LNS were delineated on axial CT scans according to existing recommendations. For each case and tumor location, 2D anteroposterior-posteroanterior (AP-PA) elective fields were applied using the AP-PA CT topograms. From the 2D portal fields, 3D dose distributions were then calculated to particular LNS. Next, 3D plans were prepared for elective nodal irradiation for tumors of different lobes. Doses for critical structures were compared for 2D and 3D plans. Results: LNS 1/2R, 1/2L, 3A, 3P, 5, 6, and 8 were not adequately covered in a substantial part of plans by standard 2D portals when guidelines for delineation were strictly followed. The magnitude of the lack of coverage increased with margin application. There was a trend for a higher yet probably still safe dose delivered to lung for 3D plans compared with 2D plans with a prescription dose of 45 Gy. Conclusions: 2D fields did not entirely cover LNS delineated according to the recommendations for 3D techniques. A strict adherence to these guidelines may lead to larger portals than traditionally constructed using 2D methods. Some modifications for clinical implementation are discussed.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Directing Matter: Toward Atomic-Scale 3D Nanofabrication

Here we report that enabling memristive, neuromorphic, and quantum based computing as well as efficient mainstream energy storage and conversion technologies requires next generation of materials customized at the atomic scale. This requires full control of atomic arrangement and bonding in three dimensions. The last two decades witnessed substantial industrial, academic, and government research efforts directed towards this goal through various lithographies and scanning probe based methods. These technologies emphasize 2D surface structures, with some limited 3D capability. Recently, a range of focused electron and ion based methods have demonstrated compelling alternative pathways to achieving atomically precise manufacturing of 3D structures in solids, liquids, and at interfaces. Electron and ion microscopies offer a platform that can simultaneously observe dynamic and static structures at the nano and atomic scales, and also induce structural rearrangements and chemical transformation. The addition of predictive modeling or rapid image analytics and feedback enables guiding these in a controlled manner. Here, we review the recent results that used focused electron and ion beams to create free-standing nanoscale 3D structures, radiolysis and the fabrication potential with liquid precursors, epitaxial crystallization of amorphous oxides with atomic layer precision, as well as visualization and control of individual dopant motion within a 3D crystal lattice. These works lay the foundation for new approaches to directing nanoscale level architectures and offer a potential roadmap to full 3D atomic control in materials. Lastly, in this perspective we lay out the gaps that currently constrain the processing range of these platforms, reflect on indirect requirements, such as the integration of large scale data analysis with theory, and discuss future prospects of these technologies.

36 MATERIALS SCIENCE↗

A detailed examination of laser-ion acceleration mechanisms in the relativistic transparency regime using tracers

Here we present a particle-in-cell study of linearly polarized laser-ion acceleration systems, in which we use both two-dimensional (2D) and three-dimensional (3D) simulations to characterize the ion acceleration mechanisms in targets which become transparent to the laser pulse during irradiation. First, we perform a target length scan to optimize the peak ion energies in both 2D and 3D, and the predictive capabilities of 2D simulations are discussed. Tracer analysis allows us to isolate the acceleration into stages of target normal sheath acceleration (TNSA), hole boring (HB), and break-out afterburner (BOA) acceleration, which vary in effectiveness based on the simulation parameters. The thinnest targets reveal that enhanced TNSA is responsible for accelerating the most energetic ions, whereas the thickest targets have ions undergoing successive phases of HB and TNSA (in 2D) or BOA and TNSA (in 3D); HB is not observed to be a dominant acceleration mechanism in the 3D simulations. It is in the intermediate optimal regime, both when the laser breaks through the target with appreciable amplitude and when there is enough plasma to form a sustained high density flow, that BOA is most effective and is responsible for the most energetic ions. Eliminating the transverse laser spot size effects by performing a plane wave simulation, we can isolate with greater confidence the underlying physics behind the ion dynamics we observe. Specifically, supplemented by wavelet and FFT analyses, we match the post-transparency BOA acceleration with a wave-particle resonance with a high-amplitude low-frequency electrostatic wave of increasing phase velocity, consistent with that predicted by the Buneman instability.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Long carrier diffusion length in two-dimensional lead halide perovskite single crystals

Ruddlesden-Popper (RP) perovskites are two-dimensional semiconductors for high-performance optoelectronic devices. In this work, we report a long in-plane carrier diffusion length in 2D RP perovskite single crystals probed by scanning photocurrent microscopy. Carrier diffusion lengths of 7–14μm are observed when the number of PbI 6 –2 octahedra between organic spacers increases from 1 to 3. Using detailed light intensity and electric-field-dependent photocurrent measurements, we attribute the observed long diffusion length to the dominating dissociated free carrier transport. This is further validated by time-resolved photoluminescence measurements, where the decay lifetime increases in the presence of an electric field. From our experiments, we conclude that the in-plane transport in RP perovskites is efficient because of the partial free carrier generation, which overcomes strong excitonic effects. In conclusion, our results suggest that semiconducting devices fabricated from RP perovskite single crystals can be as efficient as their 3D counterparts.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Design and evaluation of a device for fast multispectral time-resolved fluorescence spectroscopy and imaging

The application of time-resolved fluorescence spectroscopy (TRFS) to in vivo tissue diagnosis requires a method for fast acquisition of fluorescence decay profiles in multiple spectral bands. This study focusses on development of a clinically compatible fiber-optic based multispectral TRFS (ms-TRFS) system together with validation of its accuracy and precision for fluorescence lifetime measurements. It also presents the expansion of this technique into an imaging spectroscopy method. A tandem array of dichroic beamsplitters and filters was used to record TRFS decay profiles at four distinct spectral bands where biological tissue typically presents fluorescence emission maxima, namely, 390, 452, 542, and 629 nm. Each emission channel was temporally separated by using transmission delays through 200 μm diameter multimode optical fibers of 1, 10, 19, and 28 m lengths. A Laguerre-expansion deconvolution algorithm was used to compensate for modal dispersion inherent to large diameter optical fibers and the finite bandwidth of detectors and digitizers. The system was found to be highly efficient and fast requiring a few nano-Joule of laser pulse energy and <1 ms per point measurement, respectively, for the detection of tissue autofluorescent components. Organic and biological chromophores with lifetimes that spanned a 0.8–7 ns range were used for system validation, and the measured lifetimes from the organic fluorophores deviated by less than 10% from values reported in the literature. Multi-spectral lifetime images of organic dye solutions contained in glass capillary tubes were recorded by raster scanning the single fiber probe in a 2D plane to validate the system as an imaging tool. The lifetime measurement variability was measured indicating that the system provides reproducible results with a standard deviation smaller than 50 ps. The ms-TRFS is a compact apparatus that makes possible the fast, accurate, and precise multispectral time-resolved fluorescence lifetime measurements of low quantum efficiency sub-nanosecond fluorophores.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

MoWSSe HAADF Image Dataset

High angle annular dark field scanning transmission electron microscopy images of MoWSSe (2D quaternary alloy system), by Jordan Hachtel (Center for Nanophase Materials Sciences, Oak Ridge National Laboratory). Comes with an ipython notebook for analysis purposes.

2D materials↗

Wavelength domain spatial frequency modulation imaging: enabling fiber optic delivery and detection

Spatial frequency modulation imaging (SPIFI) provides a simple architecture for modulating an extended illumination source that is compatible with single pixel imaging. We demonstrate wavelength domain SPIFI (WD-SPIFI) by encoding time-varying spatial frequencies in the spectral domain that can produce enhanced resolution images, like its spatial domain counterpart, spatial domain (SD) SPIFI. However, contrary to SD-SPIFI, WD-SPIFI enables remote delivery by single mode fiber, which can be attractive for applications where free-space imaging is not practical. Finally, we demonstrate a cascaded system incorporating WD-SPIFI in-line with SD-SPIFI enabling single pixel 2D imaging without any beam or sample scanning.

47 OTHER INSTRUMENTATION↗

ARM X-SAPR Velocity Azimuth Display

This dataset contains Velocity Azimuth Displays from the XSAPR radars in SGP. Velocity Azimith Displays provide estimates of the 2D wind direction with height from radar scans. For more information on how these Velocity Azimuth Displays are derived, see Michelson and Seaman (2000). Michelson, S.A. and N.L. Seaman, 2000: Assimilation of NEXRAD-VAD Winds in Summertime Meteorological Simulations over the Northeastern United States. J. Appl. Meteor., 39, 367–383, https://doi.org/10.1175/1520-0450(2000)039<0367:AONVWI>2.0.CO;2

54 ENVIRONMENTAL SCIENCES↗

Experimental Characterization and Simulation of Slip Transfer at Grain Boundaries and Microstructurally-Sensitive Crack Propagation

A systematic study of crack tip interaction with grain boundaries is critical for improvement of multiscale modeling of microstructurally-sensitive fatigue crack propagation and for the computationally-assisted design of more durable materials. In this study, single, bi- and large-grain multi-crystal specimens of an aluminum-copper alloy are fabricated, characterized using electron backscattered diffraction (EBSD), and deformed under tensile loading and nano-indentation. 2D image correlation (IC) in an environmental scanning electron microscope (ESEM) is used to measure displacements near crack tips, grain boundaries and within grain interiors. The role of grain boundaries on slip transfer is examined using nano-indentation in combination with high-resolution EBSD. The use of detailed IC and EBSD-based experiments are discussed as they relate to crystal-plasticity finite element (CPFE) model calibration and validation.

Gupta, Vipul↗

Validation of Rain Rate Retrievals for the Airborne Hurricane Imaging Radiometer (HIRAD)

On board of the NASA's Global Hawk (AV1) aircraft there are two microwave, namely: the passive microwave Hurricane Imaging Radiometer (HIRAD), and the active microwave High-altitude Imaging Wind and Rain Airborne Profiler (HIWRAP). This paper presents results from an unplanned rain rate measurement validation opportunity that occurred in 2013, when the Global Hawk aircraft flew over an intense tropical squall-line that was simultaneously observed, by the Tampa NEXRAD meteorological radar. During this experiment, Global Hawk flying at an altitude of 18 km made 3 passes over the rapidly propagating thunderstorm, while the TAMPA NEXRAD perform volume scans on a 5-minute interval. NEXRAD 2D images of rain rate (mm/hr) were obtained at two altitudes (3 km & 6 km), which serve as surface truth for the HIRAD rain rate retrievals. In this paper, results are presented of the three-way inter-comparison of HIRAD Tb, HIWRAP dbZ and NEXRAD rain rate imagery.

HIRAD↗

Programmable matched filter and Hadamard transform hyperspectral imagers based on micro-mirror arrays

Hyperspectral imaging (HSI), in which each pixel contains a high-resolution spectrum, is a powerful technique that can remotely detect, identify, and quantify a multitude of materials and chemicals. The advent of addressable micro-mirror arrays (MMAs) makes possible a new class of programmable hyperspectral imagers that can perform key spectral processing functions directly in the optical hardware, thus alleviating some of HSI's high computational overhead, as well as offering improved signal-to-noise in certain important regimes (e.g. when using uncooled infrared detectors). We have built and demonstrated a prototype UV-Visible micro-mirror hyperspectral imager that is capable not only of matched-filter imaging, but also of full hyperspectral imagery via the Hadamard transform technique. With this instrument, one can upload a chemical-specific spectral matched filter directly to the MMA, producing an image showing the location of that chemical without further processing. Target chemicals are changeable nearly instantaneously simply by uploading new matched-filter patterns to the MMA. Alternatively, the MMA can implement Hadamard mask functions, yielding a full-spectrum hyperspectral image upon inverting the transform. In either case, the instrument can produce the 2D spatial image either by an internal scan, using the MMA itself, or with a traditional external push-broom scan. The various modes of operation are selectable simply by varying the software driving the MMA. Here the design and performance of the prototype is discussed, along with experimental results confirming the signal-to-noise improvement produced by the Hadamard technique in the noisy-detector regime.

47 OTHER INSTRUMENTATION↗

Localization in the SCAN meta-generalized gradient approximation functional leading to broken symmetry ground states for graphene and benzene

Density functional theory calculations play a central role in understanding chemical and solid-state systems. Progress depends on density functionals that accurately reproduce both energies, for thermochemistry, and properly describe ground states and other properties that are of interest. The Cr dimer, benzene and graphene are especially important benchmark systems for quantum chemistry and condensed matter physics. The Strongly Constrained and Appropriately Normed (SCAN) functional, which is an advanced meta-generalized gradient approximation functional that significantly improves molecular energies is shown to perform poorly for the Cr dimer. This is connected with its poor performance for itinerant solid-state magnets and is a consequence of over localization of electrons, thus illustrating an analogy between the Cr dimer and itinerant magnets. The Cr dimer is a notoriously difficult system for density functionals. However, we additionally find that SCAN predicts an incorrect symmetry broken ground state for 2D graphene and for the benzene molecule, which is surprising considering that ground states of these are known to be well described even by the simplest local density approximation. We show that SCAN overly favors localized spin polarized states, which is a serious deficiency of this approach. Thus, the challenge of finding density functionals that accurately treat both localized and delocalized electronic systems remains.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗