Advancing Elemental and Isotopic Analysis of Uranium Mineral Inclusions: Rapid Screening via Laser-Induced Breakdown Spectroscopy and High-Resolution Laser Ablation-ICP-MS Mapping

The work presented herein employs two laser-based analytical techniques (laser-induced breakdown spectroscopy (LIBS) and laser ablation – inductively coupled plasma – mass spectrometry (LA-ICP-MS)) to spatially determine the elemental and isotopic composition of uranium bearing minerals. Uniquely, this work leverages the high-speed applicability of LIBS to “screen” the sample(s) for their elemental constituents. After determining the location of the uranium inclusions (via LIBS), high-resolution LA-ICP-MS was employed to further characterize the inclusions. The high-resolution (sub-µm) capabilities of LA-ICP-MS were able to extract important information from the uranium minerals including discerning its chemical form (e.g., finchite from carnotite, Sr- and K-bearing uranyl vanadates, respectively) as well as their 235 U/ 238 U isotopic composition. This approach, LIBS followed by LA-ICP-MS, significantly reduces the analysis time (~95 %) in comparison to employing a LA-ICP-MS only approach. Furthermore, this work presented a novel approach to analyzing inclusions via a particle/inclusion analysis tool which is commercially available within the iolite 4 software. This tool allowed for a more accurate characterization of the isotopic distribution of the inclusions, as well as allowing for rapid sizing of the inclusions. Finally, this analytical approach could readily be applied to other sample types in which the target species (e.g., µm-sized inclusions) are embedded in complex matrices (e.g., cm-sized samples).

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

The use of a digital micromirror array as a temporal gate and spatial-filtering device for laser-induced breakdown spectroscopy and laser ablation molecular isotopic spectrometry

A digital micromirror array (DMMA) is used in a simple and inexpensive approach for spatially resolved temporal gating of atomic emission detection in laser-induced breakdown spectroscopy (LIBS). Selected mirrors in the array are actuated at a time delayed from the primary laser pulse, permitting optical gating with a response time of 160 ns while using a conventional CCD detector. Detector gating is shown to decrease noise from short-lived spectroscopic background (both continuum and N II from air), improving signal-to-background ratios by 22-times for selected samples and emission lines. The utility of rapid temporal gating is also demonstrated for the optical detection of isotopes using the laser-ablation molecular isotope spectrometry (LAMIS) experiment. Additionally, optical temporal gating and spatial filtering are used to isolate regions of the laser-induced plasma, enhancing signal from molecular emission. The potential of the simple technique for use in field-portable LIBS and LAMIS experiments is explored.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

U-Pu and Ba-Cs isotopic measurements on Trinitite by laser ablation sampling on the Neoma MC-ICP-MS

In this study we present the results of combined U-Pu and Ba-Cs isotope measurements obtained by laser ablation (LA) sampling of two glassy debris fragments (‘Trinitite’) from the world's first atomic bomb detonation conducted in New Mexico on July 16, 1945. Our primary goal in conducting these measurements was to understand whether examination of the U-Pu and Ba-Cs systematics by direct sampling (e.g. without any chemical separation or purification prior to isotope ratio measurement) could yield meaningful information that would differentiate the Trinitite fragments from glassy material lacking a nuclear fission signature. These measurements were conducted on a ThermoFisher Scientific Neoma multi collector – inductively coupled plasma – mass spectrometer (MC-ICP-MS), which is a relatively new MC-ICP-MS platform, so we also examine the behavior of these isotope systems in standards sampled in solution and via LA. Unsurprisingly, the measurements made on purified solutions of the U, Pu, and Ba isotopic standards produce high precision isotope ratios. Furthermore, this extends to the U-Pu measurements made by LA sampling, with the expected degradation in precision and accuracy related to matrix effects and signal intensity fluctuation. However, the Ba-Cs data acquired by LA is of low precision across all of the matrices examined and bears evidence of complex mass fractionation that will require further investigation to resolve. In total, our results indicate that the observed U-Pu isotope data are of sufficient quality to accurately constrain the U and Pu isotopic composition of glass containing sub-ppm levels of these elements which in turn could be used to differentiate glass containing anthropogenic fission products from natural glass whereas the Ba-Cs LA data cannot be used for this purpose until further methodological refinement is performed.

Ba-Cs↗

Surface Nanostructure Control and Thermodynamic Stability Analysis of Femtosecond Laser-Ablated CuCoMn 1.75 NiFe 0.25 Nanoparticles

Surface nanostructure control is the key to functionalizing nanomaterials. This paper presents a characterization with thermodynamic stability analysis of CuCoMn 1.75 NiFe 0.25 high-entropy alloy (HEA) nanoparticles synthesized by femtosecond laser ablation in ethanol and liquid nitrogen (LN2). Using multimodal electron microscopy and spectroscopy, we examine phase, particle size, defect structure, chemical distribution, and surface composition and relate them to HEA stability. Elemental distributions are uniform in both media, but LN2 produces smaller particles with a narrower size distribution and mainly single- or few-domain interiors, whereas ethanol yields larger particles built from 2–4 nm crystallites with domain aggregation. Edge defects appear in both but energy-dispersive X-ray spectroscopy (EDS) is broadly uniform with local fluctuations in ethanol. X-ray photoelectron spectroscopy (XPS), supported by an attenuation model, indicates an ∼1 nm oxide overlayer that suppresses Mn 2p intensity; correcting for it returns Mn toward the bulk value. UV–NIR and photoluminescent spectra independently support a thin oxide shell. Composition-based thermodynamic descriptors place LN2 closer to bulk mixing parameters, while ethanol raises ΔH_mix and lowers Ω. Cooling simulations are consistent (LN2 ∼ 0.1 μs quench, ethanol ∼1 μs). In conclusion, these results connect solvent-controlled kinetics and thermodynamics to crystalline state and surface chemistry, informing surface control of HEA nanoparticles.

Femtosecond Laser Ablation↗

Adaptively controlled fast production of defect-free beryllium ion crystals using pulsed laser ablation

Trapped atomic ions find wide applications ranging from precision measurement to quantum information science and quantum computing. Beryllium ions are widely used due to the light mass and convenient atomic structure of beryllium; however, conventional ion loading from thermal ovens exerts undesirable gas loads for a prolonged duration. Here, we demonstrate a method to rapidly produce pure linear chains of beryllium ions with pulsed laser ablation, serving as a starting point for large-scale quantum information processing. Our method is fast compared to thermal ovens, reduces the gas load to only 10 -12 Torr (10 -10 Pa) level, yields a short recovery time of a few seconds, and also eliminates the need for a deep ultraviolet laser for photoionization. We also study the loading dynamics, which show non-Poissonian statistics in the presence of sympathetic cooling. In addition, we apply feedback control to obtain defect-free ion chains with desirable lengths.

47 OTHER INSTRUMENTATION↗

A diagnostic to measure time-resolved atom column density and Doppler temperature in atomic vapors produced by laser ablation

We report on the development of a diagnostic to measure the time-resolved column density and Doppler temperature of atomic vapors produced by laser ablation. The diagnostic is based on the strong frequency dependence of the atomic susceptibility near an electronic transition in the interrogated atomic species. Interference on the face of a fast photodetector between the several frequency components present in a sinusoidally phase-modulated probe beam will produce a time signature uniquely determined by the column density of atoms in the probed atomic state and the Doppler temperature of the atomic vapor. With the extensive, high precision atomic spectroscopy data available in the literature, it is possible to model the vapor and extract the desired parameters through comparison of the model result with the experimental data.

47 OTHER INSTRUMENTATION↗

Effect of the magnetic field on the size of nanoparticles obtained by ablation of a cobalt – copper target in a liquid

Co – Cu nanoparticles were obtained by pulsed laser ablation in a liquid medium in a constant magnetic field. The organic solvent, hexane, served as a liquid medium. The influence of the magnetic field on the formation of nanoparticles was studied. It is shown that the magnetic field leads to a decrease in the size distribution width of the resulting nanoparticles. (paper)

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Printed Targets with Micron-Scale Feature Patterns for the Study of Ablator Defects on OMEGA

As per present models, laser imprint and implosion symmetry are insufficient to account for observed performance degradation of direct-drive cryogenic fusion implosions. More and better data are needed on ablator defects as a source of hydrodynamic instability and mix. To investigate this, a series of OMEGA experimental campaigns is underway to study isolated target defects. Key requirements are systematic variation of the laser intensity and pulse shape at shot, with highly controlled defect type, geometry, and location. Here, given the need for sub-micron resolution and precise registration of multiple features, two-photon polymerization (TPP) printing was identified as an ideal method to fabricate these targets. TPP printing has enabled controlled formation of designed domes, divots, and vacuoles for studying the combined effect of size and proximity of these features on the hydro performance.

Two-photon polymerization printing↗

Laser Ablation Plasmas and Spectroscopy for Nuclear Applications

The development of measurement methodologies to detect and monitor nuclear-relevant materials remains a consistent and significant interest across the nuclear energy, nonproliferation, safeguards, and forensics communities. Optical spectroscopy of laser-produced plasmas is becoming an increasingly popular diagnostic technique to measure radiological and nuclear materials in the field without sample preparation, where current capabilities encompass the standoff, isotopically resolved and phase-identifiable (e.g., UO and UO[Formula: see text]) detection of elements across the periodic table. These methods rely on the process of laser ablation (LA), where a high-powered pulsed laser is used to excite a sample (solid, liquid, or gas) into a luminous microplasma that rapidly undergoes de-excitation through the emission of electromagnetic radiation, which serves as a spectroscopic fingerprint for that sample. This review focuses on LA plasmas and spectroscopy for nuclear applications, covering topics from the wide-area environmental sampling and atmospheric sensing of radionuclides to recent implementations of multivariate machine learning methods that work to enable the real-time analysis of spectrochemical measurements with an emphasis on fundamental research and development activities over the past two decades. Background on the physical breakdown mechanisms and interactions of matter with nanosecond and ultrafast laser pulses that lead to the generation of laser-produced microplasmas is provided, followed by a description of the transient spatiotemporal plasma conditions that control the behavior of spectroscopic signatures recorded by analytical methods in atomic and molecular spectroscopy. High-temperature chemical and thermodynamic processes governing reactive LA plasmas are also examined alongside investigations into the condensation pathways of the plasma, which are believed to serve as chemical surrogates for fallout particles formed in nuclear fireballs. Laser-supported absorption waves and laser-induced shockwaves that accompany LA plasmas are also discussed, which could provide insights into atmospheric ionization phenomena from strong shocks following nuclear detonations. Furthermore, the standoff detection of trace radioactive aerosols and fission gases is reviewed in the context of monitoring atmospheric radiation plumes and off-gas streams of molten salt reactors. Finally, concluding remarks will present future outlooks on the role of LA plasma spectroscopy in the nuclear community.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Formation of Nano- and Micro-Scale Surface Features Induced by Long-Range Femtosecond Filament Laser Ablation

In this work, we study the characteristics of femtosecond-filament-laser–matter interactions and laser-induced periodic surface structures (LIPSS) at a beam-propagation distance up to 55 m. The quantification of the periodicity of filament-induced self-organized surface structures was accomplished by SEM and AFM measurements combined with the use of discrete two-dimensional fast Fourier transform (2D-FFT) analysis, at different filament propagation distances. The results show that the size of the nano-scale surface features increased with ongoing laser filament processing and, further, periodic ripples started to form in the ablation-spot center after irradiation with five spatially overlapping pulses. The effective number of irradiating filament pulses per spot area affected the developing surface texture, with the period of the low spatial frequency LIPSS reducing notably at a high pulse number. The high regularity of the filament-induced ripples was verified by the demonstration of the angle-of-incidence-dependent diffraction of sunlight. This work underlines the potential of long-range femtosecond filamentation for energy delivery at remote distances, with suppressed diffraction and long depth focus, which can be used in biomimetic laser surface engineering and remote-sensing applications.

36 MATERIALS SCIENCE↗

Excellent antioxidizing, thermally insulating and flame resistance silica‐polybenzoxazine aerogels for aircraft ablative materials

Abstract High‐performance thermal protective composites with lightweight, micro‐ ablation and high‐efficient thermal insulation are urgently required for thermal protection systems in advanced hypersonic speed vehicles. However, the practical applications of thermal protective composites have long been hampered by the main issues such as low mass residual rate and poor long‐term antioxidation of the matrix in high‐temperature aerobic environments. Here, we report a novel silica‐polybenz oxazine (SiO 2 ‐PBO) aerogels with interpenetrated networks, possessing the ability to antioxidation, thermal insulation, and flame‐retardant properties. The resulting SiO 2 ‐PBO aerogels exhibit low density (0.25 g/cm 3 ), low thermal conductivity (0.035 W/(m·K)), and superior peak heat release rate value (15.3 W/g). Moreover, the mass residual rate is up to 70.46 wt% in the N 2 atmosphere and remains 57.83 wt% despite existing in the air atmosphere and experiencing the highest temperature of 800°C. Briefly, SiO 2 ‐PBO aerogels as‐prepared could be a potential matrix for a new gene ration of high‐performance thermal protective composites in the future.

Xiao, Yunyun↗

A preliminary investigation into the feasibility of laser ablation U–Pb isotope ratio measurement via all‐faraday cup detection with 10 11 ‐ and 10 13 ‐Ω amplifiers on the Neoma multicollector‐inductively coupled plasma‐mass spectrometer

Rationale Signal detection for uranium–lead (U–Pb) dating of zircon is typically performed via ion counters. Here, we develop a preliminary understanding of the strengths and limitations of faraday‐cup‐based detection. Methods A suite of zircon reference materials and the NIST‐610 glass were sampled using laser ablation followed by U–Pb isotope ratio measurement on a Neoma multicollector‐inductively coupled plasma‐mass spectrometer. Results We were able to produce geologically accurate 207 Pb/ 206 Pb, 206 Pb/ 238 U, and 207 Pb/ 235 U ratios for the NIST‐610 glass and the zircon standards, with ages ranging from ~2.5 Ga to ~337 Ma (TanBrown A, Oracle, 91550, Mud Tank, Temora, and Plešovice). Two of the younger zircon standards examined (94‐35, ~55.6 Ma, and Fish Canyon, 28.6 Ma) yielded accurate 206 Pb/ 238 U but not 207 Pb/ 235 U or 207 Pb/ 206 Pb ratios, whereas the youngest zircon standard (Penglai, ~4.4 Ma) failed for all three ratios of interest. The accuracy and precision of the all‐faraday method are directly tied to signal intensity, with reliable data capable of being produced even when both isotopes in a ratio have signals below ~0.001 V (equivalent to ~62 500 cps on an ion counter). Conclusion The all‐faraday cup multicollection method provides sufficient sensitivity to obtain geologically meaningful U–Pb data, with possible advantages being that laser pit depth‐dependent changes in the observed interelemental fractionation behavior may be easier to correct using a static collector configuration compared to when the ion beam is swept across a single detector while also removing the need for an interdetector‐type calibration. Further work is needed to refine the all‐faraday cup method (e.g., application of background subtraction and common Pb corrections, outlier removal, and interelement as well as down‐hole fractionation corrections), but our initial results demonstrate that the faraday detector method has sufficient sensitivity to warrant further study.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Defect Characterization Using Positron Annihilation Spectroscopy on Laser-Ablated Surfaces

In recent years, short, pulsed laser ablation has been gaining popularity for machining small-scale test geometries from bulk samples and for efficient serial sectioning. These laser-based techniques are being added to the toolbox in material science, which makes it necessary to understand the changes in the material that occur from the laser–material interaction. Positron annihilation spectroscopy is a unique, nondestructive technique to investigate small defects in materials difficult to investigate by other tools. In this work, Doppler broadening and positron lifetime annihilation spectroscopy are utilized to help quantify the damage in materials treated with short, pulsed lasers. Using a femtosecond laser on single crystal silicon, this manuscript shows that clusters of vacancy-like defects and small voids increase systematically with laser power. Lastly, the damage induced by the laser can also reach to micrometer depths.

36 MATERIALS SCIENCE↗

Calcium fluoride as a dominating matrix for quantitative analysis by laser ablation-inductively coupled plasma-mass spectrometry (LA-ICP-MS): A feasibility study

Here, calcium fluoride formed by the reaction between ammonium bifluoride and calcium chloride was investigated as a dominating matrix for quantitative analysis by laser ablation inductively coupled plasma mass spectrometry (LA-ICP-MS). Transformation from a solid sample to the calcium fluoride-based matrix permitted quantitative analysis based on calibration standards made from elemental standards. A low abundance stable calcium isotope, i.e. 44 Ca + , was monitored as the internal standard for quantitative analysis by LA-ICP-MS. Correlation coefficient factors for multiple elements were obtained with values over 0.999. The results for multiple elements in a certified reference material of soil (NIST SRM 2710a) agreed with the certified values in the range of expanded uncertainty, indicating the present method was valid for quantitation of elements in solid samples.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Inkless, dry printing nanographene via in-Situ Coordinated laser ablation and sintering processes

Printing carbon, such as graphene and other carbon structures, for flexible and printed electronics currently relies on either ink-based printing, laser-induced forward transfer (LIFT), or laser-induced graphitization (LIG) to convert carbon-rich precursor materials, such as polymers, to graphene-like carbon structures. Liquid inks contain toxic solvents, surfactants, and stabilizing additives that degrade electrical conductivity and require high-temperature post-processing. On the other hand, LIG is limited by the substrate. Here, this study introduces an additive manufacturing method for dry-printing carbon nanomaterials, ranging from amorphous carbon to crystalline graphene-like structures, on various substrates. The system utilizes laser ablation of a solid graphite target to create pure carbon nanoparticles in situ and on demand. An inert gas carries the nanoparticles onto the substrate, where they can be deposited either as amorphous structures or laser-sintered in real time to form various graphitic structures. The study of laser processing parameters, specifically fluence and pulse repetition frequency, revealed three unique regimes of nanostructure evolution that influence the morphological and electrical properties of these printed structures. Raman spectroscopy confirmed graphitization with a resistivity slightly higher than that of the bulk graphite target. The conductivity/resistivity could be tuned as a function of sintering laser power. Scanning transmission electron microscopy (STEM) revealed that turbostratic nanographene formed with an interlayer spacing of 0.40 nm. Despite ink-based printing methods, such as screen printing, inkjet printing (IJP), and aerosol jet printing (AJP), this eco-friendly and green manufacturing technique could eliminate toxic chemicals, reduce environmental impact, and enable single-step fabrication of carbon-based devices for applications in wearable sensors, energy storage, flexible electronics, and Internet of Things (IoT) devices.

Additive nanomanufacturing↗