Search NASA⌕ Search

SEARCH · Search NASA

Results for “ALIGNMENT”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 145 records · Page 8

Structural Re-Alignment in an Immunogenic Surface Region of Ricin a Chain

We compared structure alignments generated by several protein structure comparison programs to determine whether existing methods would satisfactorily align residues at a highly conserved position within an immunogenic loop in ribosome inactivating proteins (RIPs). Using default settings, structure alignments generated by several programs (CE, DaliLite, FATCAT, LGA, MAMMOTH, MATRAS, SHEBA, SSM) failed to align the respective conserved residues, although LGA reported correct residue-residue (R-R) correspondences when the beta-carbon (Cb) position was used as the point of reference in the alignment calculations. Further tests using variable points of reference indicated that points distal from the beta carbon along a vector connecting the alpha and beta carbons yielded rigid structural alignments in which residues known to be highly conserved in RIPs were reported as corresponding residues in structural comparisons between ricin A chain, abrin-A, and other RIPs. Results suggest that approaches to structure alignment employing alternate point representations corresponding to side chain position may yield structure alignments that are more consistent with observed conservation of functional surface residues than do standard alignment programs, which apply uniform criteria for alignment (i.e. alpha carbon (Ca) as point of reference) along the entirety of the peptide chain. We present the results of tests that suggest the utility of allowing user-specifi ed points of reference in generating alternate structural alignments, and we present a web server for automatically generating such alignments: http://as2ts.llnl.gov/AS2TS/LGA/lga_pdblist_plots.html.

59 BASIC BIOLOGICAL SCIENCES↗

Effectiveness of Using Fewer Implanted Fiducial Markers for Prostate Target Alignment

Purpose: To evaluate the impact of the number and location of intraprostatic fiducial markers on the accuracy and reproducibility of daily prostate target alignment and to evaluate the migration of such markers. Methods and Materials: Three gold fiducial markers were implanted transrectally under ultrasound guidance near the apex, middle, and base of the prostate in 10 prostate cancer patients. The patients had pretreatment in-room computed tomography (CT) scans three times a week, for approximately 25 CT scans per patient during the 8-week treatment course. A total of 1280 alignments were performed using different alignment scenarios: whole-prostate soft tissue alignment (the gold standard), bone alignment, and seven permutations of alignments using one, two, or three fiducial markers. The results of bone alignment and fiducial alignment were compared with the results of whole-prostate alignment. Fiducial migration was also evaluated. Results: Single-fiducial-marker alignment was more accurate and reproducible than bone alignment. However, due to organ deformation, single fiducial markers did not always reliably represent the position of the entire prostate. The use of two-fiducial combinations was more accurate and reproducible than single-fiducial alignment, and use of all three fiducials was the best. Use of an apex fiducial together with a base fiducial rivaled the use of all three fiducials markers together. Fiducial migration was minimal. Conclusions: The number and the location of implanted fiducial markers affect the accuracy and reliability of daily prostate target alignment. The use of two or more fiducial markers is recommended.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

A line-source method for aligning on-board and other pinhole SPECT systems

Purpose: In order to achieve functional and molecular imaging as patients are in position for radiation therapy, a robotic multipinhole SPECT system is being developed. Alignment of the SPECT system—to the linear accelerator (LINAC) coordinate frame and to the coordinate frames of other on-board imaging systems such as cone-beam CT (CBCT)—is essential for target localization and image reconstruction. An alignment method that utilizes line sources and one pinhole projection is proposed and investigated to achieve this goal. Potentially, this method could also be applied to the calibration of the other pinhole SPECT systems.Methods: An alignment model consisting of multiple alignment parameters was developed which maps line sources in three-dimensional (3D) space to their two-dimensional (2D) projections on the SPECT detector. In a computer-simulation study, 3D coordinates of line-sources were defined in a reference room coordinate frame, such as the LINAC coordinate frame. Corresponding 2D line-source projections were generated by computer simulation that included SPECT blurring and noise effects. The Radon transform was utilized to detect angles (α) and offsets (ρ) of the line-source projections. Alignment parameters were then estimated by a nonlinear least squares method, based on the α and ρ values and the alignment model. Alignment performance was evaluated as a function of number of line sources, Radon transform accuracy, finite line-source width, intrinsic camera resolution, Poisson noise, and acquisition geometry. Experimental evaluations were performed using a physical line-source phantom and a pinhole-collimated gamma camera attached to a robot.Results: In computer-simulation studies, when there was no error in determining angles (α) and offsets (ρ) of the measured projections, six alignment parameters (three translational and three rotational) were estimated perfectly using three line sources. When angles (α) and offsets (ρ) were provided by the Radon transform, estimation accuracy was reduced. The estimation error was associated with rounding errors of Radon transform, finite line-source width, Poisson noise, number of line sources, intrinsic camera resolution, and detector acquisition geometry. Statistically, the estimation accuracy was significantly improved by using four line sources rather than three and by thinner line-source projections (obtained by better intrinsic detector resolution). With five line sources, median errors were 0.2 mm for the detector translations, 0.7 mm for the detector radius of rotation, and less than 0.5° for detector rotation, tilt, and twist. In experimental evaluations, average errors relative to a different, independent registration technique were about 1.8 mm for detector translations, 1.1 mm for the detector radius of rotation (ROR), 0.5° and 0.4° for detector rotation and tilt, respectively, and 1.2° for detector twist.Conclusions: Alignment parameters can be estimated using one pinhole projection of line sources. Alignment errors are largely associated with limited accuracy of the Radon transform in determining angles (α) and offsets (ρ) of the line-source projections. This alignment method may be important for multipinhole SPECT, where relative pinhole alignment may vary during rotation. For pinhole and multipinhole SPECT imaging on-board radiation therapy machines, the method could provide alignment of SPECT coordinates with those of CBCT and the LINAC.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Cellular alignment and fusion: Quantifying the effect of macrophages and fibroblasts on myoblast terminal differentiation

Highlights: • We present a method for cellular alignment calculation during routine cell culture. • Application revealed that macrophages promote myoblast alignment, but delay fusion. • Furthermore, fibroblasts regulate myoblast fusion, but not alignment. • Effect of macrophages on alignment is not altered by co-culture with fibroblasts. Successful skeletal muscle wound repair requires the alignment and fusion of myoblasts to generate multinucleated myofibers. In vitro, the accurate quantification of cellular alignment remains a challenge. Here we present the application of ImageJ and ct-FIRE to quantify muscle cell orientation by means of an alignment index (AI). Our optimised method, which does not require programming skills, allows the alignment of myoblasts in vitro to be determined independently of a predefined reference point. Using this method, we demonstrate that co-culture of myoblasts with macrophages, but not fibroblasts, promotes myoblast alignment in a cell density-dependent manner. Interestingly, myoblast fusion was significantly decreased in response to co-culture with macrophages, while the effect of fibroblasts on fusion was density-dependent. At lower numbers, fibroblasts significantly increased myoblast fusion, whereas at higher numbers a significant decrease was observed. Finally, triple co-culture revealed that the effect of macrophages on myoblast alignment and fusion is unaltered by the additional presence of fibroblasts. Application of our optimised method has therefore revealed quantitative differences in the roles of macrophages versus fibroblasts during alignment and fusion: while successful myoblast alignment is promoted by increasing macrophage numbers, regenerative fusion coincides with a decreasing macrophage population and initial rise in fibroblast numbers.

60 APPLIED LIFE SCIENCES↗

INTRINSIC ALIGNMENT OF CLUSTER GALAXIES: THE REDSHIFT EVOLUTION

We present measurements of two types of cluster galaxy alignments based on a volume limited and highly pure ({>=}90%) sample of clusters from the GMBCG catalog derived from Data Release 7 of the Sloan Digital Sky Survey (SDSS DR7). We detect a clear brightest cluster galaxy (BCG) alignment (the alignment of major axis of the BCG toward the distribution of cluster satellite galaxies). We find that the BCG alignment signal becomes stronger as the redshift and BCG absolute magnitude decrease and becomes weaker as BCG stellar mass decreases. No dependence of the BCG alignment on cluster richness is found. We can detect a statistically significant ({>=}3{sigma}) satellite alignment (the alignment of the major axes of the cluster satellite galaxies toward the BCG) only when we use the isophotal fit position angles (P.A.s), and the satellite alignment depends on the apparent magnitudes rather than the absolute magnitudes of the BCGs. This suggests that the detected satellite alignment based on isophotal P.A.s from the SDSS pipeline is possibly due to the contamination from the diffuse light of nearby BCGs. We caution that this should not be simply interpreted as non-existence of the satellite alignment, but rather that we cannot detect them with our current photometric SDSS data. We perform our measurements on both SDSS r-band and i-band data, but do not observe a passband dependence of the alignments.

79 ASTRONOMY AND ASTROPHYSICS↗

Girder Alignment Plan

The girders for the LCLS undulator system contain components which must be aligned with high accuracy relative to each other. The alignment is one of the last steps before the girders go into the tunnel, so the alignment must be done efficiently, on a tight schedule. This note documents the alignment plan which includes efficiency and high accuracy. The motivation for girder alignment involves the following considerations. Using beam based alignment, the girder position will be adjusted until the beam goes through the center of the quadrupole and beam finder wire. For the machine to work properly, the undulator axis must be on this line and the center of the undulator beam pipe must be on this line. The physics reasons for the undulator axis and undulator beam pipe axis to be centered on the beam are different, but the alignment tolerance for both are similar. In addition, the beam position monitor must be centered on the beam to preserve its calibration. Thus, the undulator, undulator beam pipe, quadrupole, beam finder wire, and beam position monitor axes must all be aligned to a common line. All relative alignments are equally important, not just, for example, between quadrupole and undulator. We begin by making the common axis the nominal beam axis in the girder coordinate system. All components will be initially aligned to this axis. A more accurate alignment will then position the components relative to each other, without incorporating the girder itself.

43 PARTICLE ACCELERATORS↗

ALIGNMENTS OF GROUP GALAXIES WITH NEIGHBORING GROUPS

Using a sample of galaxy groups found in the Sloan Digital Sky Survey Data Release 4, we measure the following four types of alignment signals: (1) the alignment between the distributions of the satellites of each group relative to the direction of the nearest neighbor group (NNG); (2) the alignment between the major axis direction of the central galaxy of the host group (HG) and the direction of the NNG; (3) the alignment between the major axes of the central galaxies of the HG and the NNG; and (4) the alignment between the major axes of the satellites of the HG and the direction of the NNG. We find strong signal of alignment between the satellite distribution and the orientation of central galaxy relative to the direction of the NNG, even when the NNG is located beyond 3r {sub vir} of the host group. The major axis of the central galaxy of the HG is aligned with the direction of the NNG. The alignment signals are more prominent for groups that are more massive and with early-type central galaxies. We also find that there is a preference for the two major axes of the central galaxies of the HG and NNG to be parallel for the system with both early central galaxies, however, not for the systems with both late-type central galaxies. For the orientation of satellite galaxies, we do not find any significant alignment signals relative to the direction of the NNG. From these four types of alignment measurements, we conclude that the large-scale environment traced by the nearby group affects primarily the shape of the host dark matter halo, and hence also affects the distribution of satellite galaxies and the orientation of central galaxies. In addition, the NNG directly affects the distribution of the satellite galaxies by inducing asymmetric alignment signals, and the NNG at very small separation may also contribute a second-order impact on the orientation of the central galaxy in the HG.

79 ASTRONOMY AND ASTROPHYSICS↗

Intrinsic Alignment of Cluster Galaxies: the Redshift Evolution

We present measurements of two types of cluster galaxy alignments based on a volume limited and highly pure ($\ge$ 90%) sample of clusters from the GMBCG catalog derived from SDSS DR7. We detect a clear BCG alignment (the alignment of major axis of the BCG toward the distribution of cluster satellite galaxies). We find that the BCG alignment signal becomes stronger as the redshift and BCG absolute magnitude decrease, and becomes weaker as BCG stellar mass decreases. No dependence of the BCG alignment on cluster richness is found. We can detect a statistically significant ($\ge$ 3 sigma) satellite alignment (the alignment of the major axes of the cluster satellite galaxies toward the BCG) only when we use the isophotal fit position angles (PAs, hereafter), and the satellite alignment depends on the apparent magnitudes rather than the absolute magnitudes of the BCGs. This suggests the detected satellite alignment based on isophotoal PAs from the SDSS pipeline is possibly due to the contamination from the diffuse light of nearby BCGs. We caution that this should not be simply interpreted as non-existence of the satellite alignment, but rather that we cannot detect them with our current photometric SDSS data. We perform our measurements on both SDSS $r$ band and $i$ band data, but did not observe a passband dependence of the alignments.

79 ASTRONOMY AND ASTROPHYSICS↗

SU-E-T-27: A Dosimetric Evaluation of Boney Anatomy Versus Fiducial Marker Alignment for the Treatment of Prostate Cancer Using Scanned Beam Proton Therapy

Purpose: In prostate proton radiotherapy, three fiducial markers are used for patient daily alignment. However fiducial alignment can change beamline heterogeneity in proton therapy. The purpose of this study is to determine the difference in fiducial and boney anatomy alignment for patient treatment. Methods and materials: Prostate cancer patients who received proton treatment were included in this study. 3 fiducial markers were implanted before the initial CT. All the patients were re-CT’d every 2 weeks to check the fiducial marker position reproducibility as well as dosimetric consistence of target coverage. In geometry study, re-CT were fused to the initial CT base on the boney anatomy and the average fiducial marker displacement was measured the centers of the fiducials. Dosimetrically, the initial plan was recalculated directly to re-CT image set based on the boney alignment and fiducial alignment to determine the difference from daily treatment. Prostate coverage and hotspots were evaluated using the dose to 98% of the CTV (D98) and dose to 2% (D2), respectively. Results: The shift from the initial 6 patient CT image sets resulted in an average change in the fiducial location of 5.70 +/− 3 mm. Dosimetric comparison from a single patient revealed that differences from the planned dose resulted from both boney and fiducial alignment. Planned clinical treatment volume coverage resulted in a D98 of 70.44Gy and D2 of 70.84Gy compared to a D98 of 70.13Gy and D2 70.94Gy for boney alignment and a D98 of 70.08Gy and D2 71.18Gy for fiducial alignment respectively. Conclusion: This study demonstrates that with boney anatomy alignment there is little change to CTV coverage and only slightly worse CTV coverage and hotspot production with fiducial alignment. An increase patient cohort and further investigation is necessary to determine the whether boney alignment can help better control dose heterogeneity.

60 APPLIED LIFE SCIENCES↗

Individual NSLS-II Multipole Magnet Alignment by Laser Trackers

The magnet alignment of the 90 th and final multipole girder assembly was completed January 17 th , 2013. Our procedure of “rough” pre-alignment by laser trackers and final alignment by vibrating wire & “Differential Variable Reluctance Transducers” (DVRT) has been quite successful, achieving magnet to magnet alignment well under the 30 micron specification. The pre-alignment accuracy is verified by the initial scan from the vibrating wire. The alignment residuals can be calculated from the offsets of a best fit line. The results are impressive, especially considering the environment of the Building 902 Annex (which has a large bay door that would open during pre-alignment, without fail), the sloppiness of the magnets’ fiducials, and especially the fact that the girders were pre-aligned to their mechanical centers, but the vibrating wire reports the magnetic centers which may be considerably different. This result hints at the potential feasibility of alignment with laser trackers for replacement magnets of NSLS-II and maybe even all magnets of future accelerators. But, it is difficult to predict the achievable accuracy until the main three error sources (a.k.a. Survey group excuses) are eliminated: measuring environment, bad magnet fiducials, and mechanical/magnetic center differences. The test performed on a large aperture quadrupole on girder assembly C19G4 was designed to answer the following questions with the aforementioned error sources either eliminated or simulated: 1) How accurately can a NSLS-II multipole be realigned after repair or other disturbance given the existing fiducials? 2) How accurately can a replacement NSLS-II multipole be installed in situ if its magnetic center is known relative to good fiducials? 3) If the current NSLS-II spares are never magnetically fiducialized, how well can they be installed using only mechanical data? 4) Could the magnets of a future accelerator (with similar alignment specifications as NSLS-II) be aligned using commercially available metrology instruments? This paper will answer these questions.

36 MATERIALS SCIENCE↗

A Comparison of Soft-Tissue Implanted Markers and Bony Anatomy Alignments for Image-Guided Treatments of Head-and-Neck Cancers

Purpose: To compare the geometric alignments of soft-tissue implanted markers to the traditional bony-based alignments in head-and-neck cancers, on the basis of daily image guidance. Dosimetric impact of the two alignment techniques on target coverage is presented. Methods and Materials: A total of 330 retrospective alignments (5 patients) were performed on daily megavoltage computed tomography (MVCT) image sets using both alignment techniques. Intermarker distances were tracked for all fractions to assess marker interfractional stability. Using a deformable image registration algorithm, target cumulative doses were calculated according to generated shifts on daily MVCT image sets. Target D95 was used as a dosimetric endpoint to evaluate each alignment technique. Results: Intermarker distances overall were stable, with a standard deviation of <1.5 mm for all fractions and no observed temporal trends. Differences in shift magnitudes between both alignment techniques were found to be statistically significant, with a maximum observed difference of 8 mm in a given direction. Evaluation of technique-specific dose coverage based on D95 of target clinical target volume and planning target volume shows small differences (within +-5%) compared with the kilovoltage CT plan. Conclusion: The use of daily MVCT imaging demonstrates that implanted markers in oral tongue and soft-palate cancers are stable localization surrogates. Alignments based on implanted markers generate shifts comparable overall to the traditional bony-based alignment, with no observed systematic difference in magnitude or direction. The cumulative dosimetric impact on target clinical target volume and planning target volume coverage was found to be similar, despite large observed differences in daily alignment shifts between the two techniques.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

PDV Probe Alignment Technique

This alignment technique was developed while performing heterodyne velocimetry measurements at LLNL. There are a few minor items needed, such as a white card with aperture in center, visible alignment laser, IR back reflection meter, and a microscope to view the bridge surface. The work was performed on KCP flyers that were 6 and 8 mils wide. The probes used were Oz Optics manufactured with focal distances of 42mm and 26mm. Both probes provide a spot size of approximately 80?m at 1550nm. The 42mm probes were specified to provide an internal back reflection of -35 to -40dB, and the probe back reflections were measured to be -37dB and -33dB. The 26mm probes were specified as -30dB and both measured -30.5dB. The probe is initially aligned normal to the flyer/bridge surface. This provides a very high return signal, up to -2dB, due to the bridge reflectivity. A white card with a hole in the center as an aperture can be used to check the reflected beam position relative to the probe and launch beam, and the alignment laser spot centered on the bridge, see Figure 1 and Figure 2. The IR back reflection meter is used to measure the dB return from the probe and surface, and a white card or similar object is inserted between the probe and surface to block surface reflection. It may take several iterations between the visible alignment laser and the IR back reflection meter to complete this alignment procedure. Once aligned normal to the surface, the probe should be tilted to position the visible alignment beam as shown in Figure 3, and the flyer should be translated in the X and Y axis to reposition the alignment beam onto the flyer as shown in Figure 4. This tilting of the probe minimizes the amount of light from the bridge reflection into the fiber within the probe while maintaining the alignment as near normal to the flyer surface as possible. When the back reflection is measured after the tilt adjustment, the level should be about -3dB to -6dB higher than the probes specified back reflection. This 3 to 6dB increase in back reflection from the surface relative to the probes specified back reflection is the optimal level for acquiring data from the flyer. Data obtained with the LLNL system is shown in Figure 5.

42 ENGINEERING↗

Alignment of Short Reads: A Crucial Step for Application of Next-Generation Sequencing Data in Precision Medicine

Precision medicine or personalized medicine has been proposed as a modernized and promising medical strategy. Genetic variants of patients are the key information for implementation of precision medicine. Next-generation sequencing (NGS) is an emerging technology for deciphering genetic variants. Alignment of raw reads to a reference genome is one of the key steps in NGS data analysis. Many algorithms have been developed for alignment of short read sequences since 2008. Users have to make a decision on which alignment algorithm to use in their studies. Selection of the right alignment algorithm determines not only the alignment algorithm but also the set of suitable parameters to be used by the algorithm. Understanding these algorithms helps in selecting the appropriate alignment algorithm for different applications in precision medicine. Here, we review current available algorithms and their major strategies such as seed-and-extend and q-gram filter. We also discuss the challenges in current alignment algorithms, including alignment in multiple repeated regions, long reads alignment and alignment facilitated with known genetic variants.

59 BASIC BIOLOGICAL SCIENCES↗

Heavy Higgs boson decays in the alignment limit of the 2HDM

The Standard Model (SM)-like couplings of the observed Higgs boson impose strong constraints on the structure of any extended Higgs sector. We consider the theoretical properties and the phenomenological implications of a generic two Higgs doublet model (2HDM). This model constitutes a simple and attractive extension of the SM that is consistent with the observation of the SM-like Higgs boson and precision electroweak observables, while providing a potential new source of CP-violation. In this paper we focus on the so-called Higgs alignment limit of the generic 2HDM, where the neutral scalar field H 1 , with the tree-level couplings of the SM Higgs boson, is a mass eigenstate that is aligned in field space with the direction of the Higgs vacuum expectation value. Tihe properties of the two other heavier neutral Higgs scalars, H 2 and H 3 , in the alignment limit of the 2HDM are also elucidated. It is shown that the couplings of H 2 and H 3 in the alignment limit are tightly constrained and correlated. For example, in the exact alignment limit at tree level, for bosonic final states BR( H 2,3 → W + W - , ZZ, H 1 Z ) = 0 and BR( H ± → W ± H 1 ) = 0, whereas for fermionic final states Γ( H 2 → ff ¯) / Γ( H 3 → ff ¯) ~ M 2 /M 3 (where M α is the mass of H α ). In some cases, the results of the alignment limit differ depending on whether or not alignment is achieved via the decoupling of heavy scalar states. In particular, in the exact alignment limit without decoupling BR( H 2,3 → H 1 H 1 ) = 0, whereas these branching ratios are nonzero in the decoupling regime. Observables that could be used to test the alignment scenario at the LHC are defined and discussed. The couplings of the Higgs bosons away from their exact alignment values are determined to leading order, and some consequences are elucidated.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Thermoreversible Changes in Aligned and Cross-Linked Block Copolymer Melts Studied by Two Color Depolarized Light Scattering

A procedure for creating samples that can be repeatedly cycled between weakly aligned and strongly aligned states is described. Poly(styrene-b-isoprene) block copolymer samples were first shear-aligned and then cross-linked using a high energy electron beam. Samples with more than 1.0 cross-links per chain on average showed almost complete recovery of their initial alignment state even after 20 cycles of heating above the order–disorder transition temperature of the un-cross-linked block copolymer. Samples with 1.1 cross-links per chain, which showed over 90% loss of alignment on heating and almost 100% recovery of alignment on cooling, provided the best example of a reversible aligned-to-unaligned transition. Samples with lower cross-linking densities exhibited irreversible loss of alignment upon heating, while those with higher cross-linking densities exhibited less than 90% loss of alignment upon heating. Alignment was quantified by a technique that we call two color depolarized light scattering (TCDLS), an extension of the traditional depolarized light scattering experiment used to determine the state of order in block copolymers. Qualitative confirmation of our interpretation of TCDLS data was obtained by small-angle X-ray scattering and transmission electron microscopy.

Wilbur, Jeffrey D.↗

SU-F-J-44: Development of a Room Laser Based Real-Time Alignment Monitoring System Using An Array of Photodiodes

Purpose: To develop a real-time alignment monitoring system (RAMS) to compensate for the limitations of the conventional room laser based alignment system, and to verify the feasibility of the RAMS. Methods: The RAMS was composed of a room laser sensing array (RLSA), an analog-todigital converter, and a control PC. In the RLSA, seven photodiodes (each in 1 mm width) are arranged in a pattern that the RAMS provides alignment in 1 mm resolution. It works based on detecting laser light aligned on one of photodiodes. When misaligned, the laser would match with different photodiode(s) giving signal at unexpected location. Thus, how much displaced can be determined. To verify the reproducibility of the system with respect to time as well as repeated set-ups, temporal reproducibility and repeatability test was conducted. The accuracy of the system was tested by obtaining detection signals with varying laser-match positions. Results: The signal of the RAMS was found to be stable with respect to time. The repeatability test resulted in a maximum coefficient of variance of 1.14%, suggesting that the signal of the RAMS was stable over repeated set-ups. In the accuracy test, signals between when the laser was aligned and notaligned with any of sensors could be distinguished by signal intensity. The signals of not-aligned sensors were always below 75% of the signal of the aligned sensor. It was confirmed that the system could detect 1 mm of movement by monitoring the pattern of signals, and could observe the movement of the system in real-time. Conclusion: We developed a room laser based alignment monitoring system. The feasibility test verified that the system is capable of quantitative alignment monitoring in real time. The system is relatively simple, not expensive, and considered to be easily incorporated into conventional room laser systems for real-time alignment monitoring. This research was supported by the Mid-career Researcher Program through NRF funded by the Ministry of Science, ICT & Future Planning of Korea (NRF-2014R1A2A1A10050270) and by the Radiation Technology R&D program through the National Research Foundation of Korea funded by the Ministry of Science, ICT & Future Planning (No. 2013M2A2A7038291)

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Measuring Global Credibility with Application to Local Sequence Alignment

Computational biology is replete with high-dimensional (high-D) discrete prediction and inference problems, including sequence alignment, RNA structure prediction, phylogenetic inference, motif finding, prediction of pathways, and model selection problems in statistical genetics. Even though prediction and inference in these settings are uncertain, little attention has been focused on the development of global measures of uncertainty. Regardless of the procedure employed to produce a prediction, when a procedure delivers a single answer, that answer is a point estimate selected from the solution ensemble, the set of all possible solutions. For high-D discrete space, these ensembles are immense, and thus there is considerable uncertainty. We recommend the use of Bayesian credibility limits to describe this uncertainty, where a (1–α)%, 0≤α≤1, credibility limit is the minimum Hamming distance radius of a hyper-sphere containing (1–α)% of the posterior distribution. Because sequence alignment is arguably the most extensively used procedure in computational biology, we employ it here to make these general concepts more concrete. The maximum similarity estimator (i.e., the alignment that maximizes the likelihood) and the centroid estimator (i.e., the alignment that minimizes the mean Hamming distance from the posterior weighted ensemble of alignments) are used to demonstrate the application of Bayesian credibility limits to alignment estimators. Application of Bayesian credibility limits to the alignment of 20 human/rodent orthologous sequence pairs and 125 orthologous sequence pairs from six Shewanella species shows that credibility limits of the alignments of promoter sequences of these species vary widely, and that centroid alignments dependably have tighter credibility limits than traditional maximum similarity alignments.

59 BASIC BIOLOGICAL SCIENCES↗

Alignments between Galaxies and the Cosmic Web at z ~ 1–2 in the IllustrisTNG Simulations

Galaxy formation theories predict that galaxy shapes and angular momenta have nonrandom alignments with the cosmic web. This leads to so-called intrinsic alignment between pairs of galaxies, which is important to quantify as a nuisance parameter for weak lensing. We study galaxy–cosmic web alignment in the IllustrisTNG suite of hydrodynamical simulations at redshifts 1 and 2, finding that alignment trends are consistent with previous studies. However, we find that the magnitude of the spin alignment signal is ~2.4× weaker than seen in previous studies of the Horizon-AGN simulation, suggesting that this signal may have a significant dependence on subgrid physics. Based on IllustrisTNG, we then construct mock observational spectroscopic surveys that can probe shape–cosmic web alignment at z ~ 1–2, modeled on the low-z galaxy redshift and IGM tomography surveys on the upcoming Subaru Prime Focus Spectrograph Galaxy Evolution (PFS GE) survey. However, even over box sizes of L = 205 h -1 Mpc, we find that global anisotropies induce a sample variance in the 2D projected alignment signal that depend on the projected direction; this induces significant errors in the observed alignment. We predict a 5.3σ detection of IllustrisTNG's shape alignment signal at z ~ 1 from Subaru PFS GE, although a detection would be challenging at z ~ 2. However, a rough rescaling of the relative alignment signal strengths between the TNG and Horizon-AGN simulations suggests that PFS GE should be able to more easily constrain the latter's stronger signal.

79 ASTRONOMY AND ASTROPHYSICS↗