Search NASA⌕ Search

SEARCH · Search NASA

Results for “ALTERNATIVE COMPLIANCE”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 145 records · Page 8

Advanced Modeling of Contaminant Fate and Transport in Soil and Groundwater from F-Canyon and the Central Laboratory Facility

F-Canyon (221-F) was constructed in the early 1950's and, together with FB Line, began operations in 1954 as the main processing facilities in FArea of SRS. The primary operations conducted in F-Canyon and FB Line included the separation and recovery of Pu-239 and U-238 from irradiated materials and the stabilization of plutonium residues. The F/H Laboratory Complex consists of buildings 772-F, 772-1F, and 772-4F which began operations in 1954, 1987, and 1993, respectively. The primary mission of the F/H Laboratory Complex for the last 45 years has been to support the chemical separations processing activities at Building 221-F and H-Canyon. The objective of this study is to determine the radionuclide and hazardous material holdup in F-Canyon and its support facilities, and to evaluate In-Situ Disposal (ISD) alternatives for deactivation and decommissioning (D and D) of these facilities to ensure groundwater protection and environmental compliance with the South Carolina Department of Health and Environmental Services (SCDHES) and the United States Environmental Protection Agency (USEPA). GoldSim is a dynamic probabilistic simulation software that allows modeling of chemical mass transport through engineered and environmental systems For this study, it will model the potential future release of radiological contamination through the vadose zone, Upper Three Runs (UTR) Aquifer and the Upper Three Runs Creek. Using a GoldSim model developed for building 235-F D and D, contaminant inventories as well as building geometry were updated to create the basis of the new F-Canyon model. The inventories from F-Canyon, FB Line, and the 800 Series Tanks (Tanks 804, 808, and 809) as well as F/H labs (including buildings 772-F, 772-1F, and 772- 4F) were used to make a total of four sources. The concentrations of total uranium and beta-gamma are within compliance for the study, while radium and alpha concentrations exceed their MCL's around 30,000 years and total effective water dose exceeds its MCL around 1,200 years. This suggests that some level of action will be needed to meet SCDHES and USEPA requirements. This evaluation was conducted only for the no-action alternative. Consideration and modeling of other alternatives will be required in the future to determine the best ISD alternative for D and D of F-Canyon and F/H labs with regard to groundwater protection, worker safety, and financial cost.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Exploring Polarization Rotation Phase Instabilities in Super-Tetragonal BiFeO3 Epitaxial Thin Films and Their Technological Implications

Many functional properties of ferroelectrics are underlain by structural instabilities, which render these materials very susceptible to small alternating applied fields (electric, mechanical, etc.) through certain constitutive coupling relations, e.g., elastic compliance and piezoelectric response, and often such instabilities can be shifted by static applied fields thus meaning tunable dynamic properties. Structural instabilities are naturally accommodated on the brink of morphotropic phase boundaries (MPB s) where multiple phases of small energy difference coexist in different crystallographic forms. Canonical MPB is realized through compositional mixture, as is typically exemplified by Pb(Zr1-xTix)O3 solid solutions and relaxor ferroelectrics of (1-x)PbMg1/3Nb2/3O3-xPbTiO3. More recently, a strain-driven MPB has been discovered in BiFeO3 (BFO) thin films epitaxially grown on LaAlO3 (LAO) crystal substrates (which imposes about -4.5% in-plane strains). Such an MPB is in between a rhombohedral (R) phase that bulk BFO exhibits and a so-called super-tetragonal (T) phase, which name hints at its giant lattice axial ratio (c/a ~ 1.23) and accordingly high electric polarization (~1.5 C m-2). The discovery of an MPB in BFO has revealed another facet of this multiferroic system, further adding opportunities to its many exotic functionalities such as domain wall conduction, magnetoelectric and photovoltaic effects As with other MPB s, large electric-field induced strains as well as more underlying lattice softening effects are observed near this MPB promising piezoelectric-based applications. In addition, T-phase BFO itself shows distinct properties, e.g., electronic band gap and optical absorption, from the R-phase and the resultant switching effects between them may also be exploitable. However, unlike conventional ferroelectric oxides where the phases across an MPB usually have subtle difference caused by rotations of an ion off-centering polarization, the BFO system bears multiple structural degrees of freedom, in particular antiferrodistortive modes of oxygen octahedral tilt, and a multitude of structural transition paths are thereby facilitated. Moreover, since the MPB of BFO is driven by epitaxial strain, it is sensitive to the strain relaxation related to film thickness and growth conditions, and above some critical thickness the films appear in the form of a hierarchical mixed-phase microstructure involving several coexistent polymorphs with distinct lattice distortion (monoclinic phases) and tilts. Elastic and electrical heterogeneities are necessary consequences of such complex microstructure, which couple to the intrinsic order parameters and expectedly have profound influence on the structural dynamics and material properties. All these make it a demanding task to obtain a deep understanding of this MPB system on par with its application prospect. The thin-film material form also brings in experimental restrictions to the MPB phase transition studies of BFO since many pertinent techniques fail to operate at the nanoscale or suffer from formidably weak signals. Therefore, static structural characterizations using e.g. X-ray diffraction, electron microscopy and Raman scattering have prevailed thus far. Recently, we adapted band-excitation piezoresponse spectroscopy (BEPS) to probe the bias-induced R/T phase transition dynamics of BFO/SrTiO3 (STO) thin films, and revealed the soft-mode elastic behavior of the transition. The efficacy of our method, along with standard piezoresponse force microscopy (PFM), can be significantly leveraged by integrating a variety of local and/or global excitations, e.g., tip pressure (10 s GPa attainable), heating, photo-irradiation, available to modern scanning probe platforms. This can thus afford unique opportunities to survey the structural dynamics of ferroelectric materials coupled to those field variables, enabling rapid discovery or validation of their functional properties. In this study, we focus on the T-phase BFO/LAO system; we have examined its phase transition behavior not only due to local coaction of tip bias and loading force, but also under device-level global electric fields in a coplanar capacitor. The intrinsic elastic softening phenomena near the structural transitions are comprehensively revealed by BEPS and corroborated by phase-field modeling. Our findings may open a new pathway for technological utilization of the MPB phase instabilities of BFO.

BiFeO3↗

Performance experiments with alternative advanced teleoperator control modes for a simulated solar maximum satellite repair

Experiments are described which were conducted at the JPL Advanced Teleoperator Lab to demonstrate and evaluate the effectiveness of various teleoperator control modes in the performance of a simulated Solar Max Satellite Repair (SMSR) task. THe SMSR was selected as a test because it is very rich in performance capability requirements and it actually has been performed by two EVA astronauts in the Space Shuttle Bay in 1984. The main subtasks are: thermal blanket removal; installation of a hinge attachment for electrical panel opening; opening of electrical panel; removal of electrical connectors; relining of cable bundles; replacement of electrical panel; securing parts and cables; re-mate electrical connectors; closing of electrical panel; and reinstating thermal blanket. The current performance experiments are limited to thermal blanket cutting, electrical panel unbolting and handling electrical bundles and connectors. In one formal experiment even different control modes were applied to the unbolting and reinsertion of electrical panel screws subtasks. The seven control modes are alternative combinations of manual position and rate control with force feedback and remote compliance referenced to force-torque sensor information. Force-torque sensor and end effector position data and task completion times were recorded for analysis and quantification of operator performance.

Das, H.↗

NASA Operational Environment Team (NOET) - NASA's key to environmental technology

NOET is a NASA-wide team which supports the research and development community by sharing information both in person and via a computerized network, assisting in specification and standard revisions, developing cleaner propulsion systems, and exploring environmentally compliant alternatives to current processes. NOET's structure, dissemination of materials, electronic information, EPA compliance, specifications and standards, and environmental research and development are discussed.

Cook, Beth↗

A Modified Edge Crack Torsion Test for Measurement of Mode III Fracture Toughness of Laminated Tape Composites

Modifications to the edge crack torsion (ECT) test are studied to improve the reliability of this test for measuring the mode-III fracture toughness, G (sub IIIc), of laminated tape fiber-reinforced polymeric (FRP) composites. First, the data reduction methods currently used in the ECT test are evaluated and deficiencies in their accuracy are discussed. An alternative data reduction technique, which uses a polynomial form to represent ECT specimen compliance solution, is evaluated and compared to FEA (finite element analysis) results. Second, seven batches of ECT specimens are tested, each batch containing specimens with a preimplanted midplane edge delamination and midplane plies with orientations of plus theta divided by minus theta, with theta ranging from 0 degrees to 90 degrees in 15-degree increments. Tests on these specimens show that intralaminar cracking occurs in specimens from all batches except for which theta = 15 degrees and 30 degrees. Tests on specimens of these two batches are shown to result in mode-III delamination growth at the intended ply interface. The findings from this study are encouraging steps towards the use of the ECT test as a standardized method for measuring G (sub IIIc), although further modification to the data reduction method is required to make it suitable for use as part of a standardized test method.

Czabaj, Michael W.↗

Data Validation Package November 2015 Groundwater and Surface Water Sampling at the Old and New Rifle, Colorado, Processing Sites February 2016

Water samples were collected from 36 locations at New Rifle and Old Rifle, Colorado, Processing Sites. Duplicate samples were collected from New Rifle locations 0659 and 0855, and Old Rifle location 0304. One equipment blank was collected after decontamination of non-dedicated equipment used to collect one surface water sample. Sampling and analyses were conducted as specified in the Sampling and Analysis Plan for U.S. Department of Energy Office of Legacy Management Sites (LMS/PRO/S04351, continually updated). New Rifle Site Samples were collected at the New Rifle site from 16 monitoring wells and 7 surface locations in compliance with the December 2008 Groundwater Compliance Action Plan [GCAP] for the New Rifle, Colorado, Processing Site (LMS/RFN/S01920), with one exception: New Rifle location 0635 could not be sampled because it was inaccessible; a fence installed by the Colorado Department of Transportation prevents access to this location. DOE is currently negotiating access with the Colorado Department of Transportation. Analytes measured at the New Rifle site included contaminants of concern (COCs) (arsenic, molybdenum, nitrate + nitrite as nitrogen, selenium, uranium, and vanadium) ammonia as nitrogen, major cations, and major anions. Field measurements of total alkalinity, oxidation- reduction potential, pH, specific conductance, turbidity, and temperature were made at each location, and the water level was measured at each sampled well. A proposed alternate concentration limit (ACL) for vanadium of 50 milligrams per liter (mg/L), specific to the compliance (POC) wells (RFN-0217, -0659, -0664, and -0669) is included in the New Rifle GCAP. Vanadium concentrations in the POC wells were below the proposed ACL as shown in the time-concentration graphs in the Data Presentation section (Attachment 2). Time-concentration graphs from all other locations sampled are also included in Attachment 2. Sampling location RFN-0195 was misidentified for the June/August 2014 and November 2014 sampling events. (Well RFN-0609 was inadvertently sampled instead of RFN-0195 in 2014.) The results for RFN-0195 have been corrected, and are included in associated time-concentration graphs for this location. Recent results for RFN-0195 are consistent with established trends with the possible exception of vanadium. The most recent result for vanadium showed an increase over recent values. Vanadium concentrations at RFN-0195 and other locations will continue to be evaluated in the future to determine the potential for deviations from established trends. The surface water locations were sampled to monitor the impact of groundwater discharge. COC concentrations at Colorado River surface water locations RFN-0324 and RFN-0326, downgradient of the site, remained low and were consistent with historical results, as shown in the time-concentration graphs. COC concentrations did not indicate there are any impacts related to groundwater discharge to the river. In many cases, elevated COC concentrations at the New Rifle site pond locations were observed, as shown in the time-versus concentration graphs. As noted in the GCAP, this indicates impacts from groundwater discharge to the ponds. Old Rifle Site Samples were collected at the Old Rifle site from eight monitoring wells and five surface locations in compliance with the December 2001 Groundwater Compliance Action Plan for the Old Rifle, Colorado, UMTRA Project Site (GJ0-2000-177-TAR). Analytes measured at the Old Rifle site included COCs (selenium, uranium, and vanadium), major cations, and major anions. Field measurements of total alkalinity, oxidation-reduction potential, pH, specific conductance, turbidity, temperature, were made at each location, and the water level was measured at each sampled well. The monitoring strategy described in the GCAP is designed to determine progress of the natural flushing process in meeting compliance standards for site COCs. Standards for selenium and vanadium are the proposed ACLs of0.05 mg/L and 1.0 mg/L, respectively. For uranium the cleanup goal is the UMTRA standard of 0.044 mg/L or background, whichever is higher. As shown in the time concentration graphs, the uranium concentration exceeds the cleanup goal at groundwater monitoring locations RF0-0304, -0305, -0310, -0655, and -0656. The surface water locations were sampled to monitor the impact of groundwater discharge at Colorado River surface water locations adjacent to (RF0-0396) and downgradient of the site (RF0-0741). COC concentrations remain low and consistent with historical concentrations as shown in the time-concentration graphs (Attachment 2), which indicate no impacts from groundwater discharge to the river.

2015 Old and New Rifle↗

APPLICATION FO FLOW FORMING FOR USE IN RADIOACTIVE MATERIAL PACKAGING DESIGNS

This paper reports on the development and testing performed to demonstrate the use of flow forming as an alternate method of manufacturing containment vessels for use in radioactive material shipping packaging designs. Additionally, ASME Boiler and Pressure Vessel Code, Section III, Subsection NB compliance along with the benefits compared to typical welding of containment vessels will be discussed. SRNL has completed fabrication development and the testing on flow formed containment vessels to demonstrate the use of flow forming as an alternate method of manufacturing a welded 6-inch diameter containment vessel currently used in the 9975 and 9977 radioactive material shipping packaging. Material testing and nondestructive evaluation of the flow formed parts demonstrate compliance to the minimum material requirements specified in applicable parts of ASME Boiler and Pressure Vessel Code, Section II. Destructive burst testing shows comparable results to that of a welded design. The benefits of flow forming as compared to typical welding of containment vessels are significant: dimensional control is improved due to no weld distortion; less final machining; weld fit-up issues associated with pipes and pipe caps are eliminated; post-weld non-destructive testing (i.e., radiography and die penetrant tests) is not necessary; and less fabrication steps are required. Results presented in this paper indicate some of the benefits in adapting flow forming to design of future radioactive material shipping packages containment vessels.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

The Oak Ridge Refrigerant Management Program

For many years, chlorofluorocarbons (CFC's) have been used by the Department of Energy's (DOE) Oak Ridge Y-12 Plant in air conditioning and process refrigeration systems. However, Title 6 of the Clean Air Act Amendments (CAAA) and Executive Order 12843 (Procurement Requirements and Policies for Federal Agencies for Ozone Depleting Substances) signed by President Clinton require, as policy, that all federal agencies maximize their use of safe, alternate refrigerants and minimize, where economically practical, the use of Class 1 refrigerants. Unfortunately, many government facilities and industrial plants have no plan or strategy in place to make this changeover, even though their air conditioning and process refrigeration equipment may not be sustainable after CFC production ends December 31, 1995. The Y-12 Plant in Oak Ridge, Tennessee, has taken an aggressive approach to complying with the CAAA and is working with private industry and other government agencies to solve tough manufacturing and application problems associated with CFC and hydrochlorofluorocarbon (HCFC) alternatives. Y-12 was the first DOE Defense Program (DP) facility to develop a long-range Stratospheric Ozone Protection Plan for refrigerant management for compliance with the CAAA. It was also the first DOE DP facility to complete detailed engineering studies on retrofitting and replacing all air conditioning and process refrigeration equipment to enable operation with alternate refrigerants. The management plan and engineering studies are models for use by other government agencies, manufacturing plants, and private industry. This presentation identifies some of the hidden pitfalls to be encountered in the accelerated phaseout schedule of CFC's and explains how to overcome and prevent these problems. In addition, it outlines the general issues that must be considered when addressing the phase-out of ozone depleting substances and gives some 'lessons learned' by Y-12 from its Refrigerant Management Program. Discussion topics include requirements for developing a refrigerant management plan and establishing priorities for cost-effective compliance with the CAAA, as well as ways in which employees can be empowered to develop a comprehensive refrigerant management plan. The result of this employee empowerment was a cooperative labor-management effort that is beneficial for Y-12, DOE, and the environment.

Kevil, Thomas H.↗

Guidance for Federal Agencies on EPAct 2005 Section 701: Alternative Fuel Use Requirements for Dual-Fueled Vehicles

Section 701 of the Energy Policy Act of 2005 (EPAct 2005) requires Federal agencies to use alternative fuel in dual-fueled vehicles when it is reasonably available and not unreasonably more expensive than gasoline (42 U.S.C. Section 6374(a)(3)(E)). Since 2007, Federal agencies have requested waivers for vehicles from the Section 701 requirements as part of a June data call for the subsequent fiscal year (FY). The U.S. Department of Energy (DOE) Federal Energy Management Program (FEMP) has reviewed those waiver requests and granted or denied them prior to the subsequent FY. At the end of each FY, DOE FEMP has reviewed each Federal agency's covered alternative fuel use and compared it to total fuel use in non-waivered vehicles to determine compliance. This guidance provides two different processes through which DOE will begin evaluating waiver requests for FY 2021 (beginning with the FY 2020 data call): Automated reporting in the Federal Fleet Sustainability Dashboard (FleetDASH), and waiver requests in FAST.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Use of a hybrid technology in a critical security system.

Assigning an acceptable level of power reliability in a security system environment requires a methodical approach to design when considering the alternatives tied to the reliability and life of the system. The downtime for a piece of equipment, be it for failure, routine maintenance, replacement, or refurbishment or connection of new equipment is a major factor in determining the reliability of the overall system. In addition to these factors is the condition where the system is static or dynamic in its growth. Most highly reliable security power source systems are supplied by utility power with uninterruptable power source (UPS) and generator backup. The combination of UPS and generator backup with a reliable utility typically provides full compliance to security requirements. In the energy market and from government agencies, there is growing pressure to utilize alternative sources of energy other than fossil fuel to increase the number of local generating systems to reduce dependence on remote generating stations and cut down on carbon effects to the environment. There are also conditions where a security system may be limited on functionality due to lack of utility power in remote locations. One alternative energy source is a renewable energy hybrid system including a photovoltaic or solar system with battery bank and backup generator set. This is a viable source of energy in the residential and commercial markets where energy management schemes can be incorporated and systems are monitored and maintained regularly. But, the reliability of this source could be considered diminished when considering the security system environment where stringent uptime requirements are required.

14 SOLAR ENERGY↗

Use of a hybrid technology in a critical security system.

Assigning an acceptable level of power reliability in a security system environment requires a methodical approach to design when considering the alternatives tied to the reliability and life of the system. The downtime for a piece of equipment, be it for failure, routine maintenance, replacement, or refurbishment or connection of new equipment is a major factor in determining the reliability of the overall system. In addition to these factors is the condition where the system is static or dynamic in its growth. Most highly reliable security power source systems are supplied by utility power with uninterruptable power source (UPS) and generator backup. The combination of UPS and generator backup with a reliable utility typically provides full compliance to security requirements. In the energy market and from government agencies, there is growing pressure to utilize alternative sources of energy other than fossil fuel to increase the number of local generating systems to reduce dependence on remote generating stations and cut down on carbon effects to the environment. There are also conditions where a security system may be limited on functionality due to lack of utility power in remote locations. One alternative energy source is a renewable energy hybrid system including a photovoltaic or solar system with battery bank and backup generator set. This is a viable source of energy in the residential and commercial markets where energy management schemes can be incorporated and systems are monitored and maintained regularly. But, the reliability of this source could be considered diminished when considering the security system environment where stringent uptime requirements are required.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Life-Cycle Cost Analysis Framework for Water Efficiency Measures

Life-Cycle Cost Analysis Framework for Water Efficiency Measures: Guidance Designed for Federal Agencies (hereafter referred to as “this report”) provides a technical framework for federal agencies to conduct a life-cycle cost analysis (LCCA) for water efficiency projects in accordance with 42 U.S.C. § 8253. This report leverages insights from the 2023 report, PNNL-34006, Water and Wastewater Annual Price Escalation Rates for Selected Cities Across the United States: 2023 Edition (Unger et al. 2023). The primary objective of this report is to provide a framework to assist federal agencies with evaluating the full economic impact of water efficiency projects by assessing both initial investments and long-term operational benefits. An LCCA can provide a comprehensive view of all costs associated with a water efficiency project, including initial investment, ongoing operations and maintenance (O&M), and eventual disposal or replacement, ensuring the most cost-effective solution is selected. The LCCA methodology outlined in this report enables users to compare base case scenarios with potential alternatives using a standardized present value approach. It incorporates key cost components such as energy, water and wastewater, installation, O&M, and equipment replacement. Additionally, the framework introduces relevant evaluation metrics, such as the net savings and the savings-to-investment ratio, to ensure that water efficiency measures are economically justified over the lifespan of the project. To support practical application, this report also describes various water efficiency strategies that may be analyzed using an LCCA, including plumbing retrofits, irrigation upgrades, alternative water use, and cooling system improvements. By applying this framework, federal agencies can ensure compliance with regulatory mandates while maximizing the return on investment and contributing to resilient water management practices. The information provided in this report is aligned with the Federal Energy Management Program (FEMP) life-cycle cost (LCC) methodology, as conveyed in National Institute of Standards and Technology (NIST) Handbook 135 (Kneifel and Webb 2022). This report is intended to provide relatively high-level guidance, acting as a complement to, rather than a substitute for, that resource.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Energy Management Programs at the John F. Kennedy Space Center

The Energy Management internship over the summer of 2011 involved a series of projects related to energy management on the John. F. Kennedy Space Center (KSC). This internship saved KSC $14.3 million through budgetary projections, saved KSC $400,000 through implementation of the recycling program, updated KSC Environmental Management System's (EMS) water and energy-related List of Requirements (LoR) which changed 25.7% of the list, provided a incorporated a 45% design review of the Ordnance Operations Facility (OOF) which noted six errors within the design plans, created a certification system and timeline for implementation regarding compliance to the federal Guiding Principles, and gave off-shore wind as the preferred alternative to on-site renewable energy generation.

Huang, Jeffrey H.↗

Reexamination of the Edge Crack Torsion Test for Determining the Mode III Delamination Toughness of Laminated Composites

The edge crack torsion (ECT) test is reexamined to address two primary concerns with this method. The first of these relates to inconsistencies in the data reduction procedure that was originally proposed and is most commonly used to compute the mode III interlaminar fracture toughness, G(sub IIIc), from the experimental data. The second relates to the observation that plies neighboring the preimplanted insert in the standard ECT layup are unable to contain initiation and growth of intralaminar cracks, and that growth of these cracks contributes to errors in the apparent values of G(sub IIIc). To address these issues, an alternative data reduction technique, which uses a polynomial expression to represent the ECT specimen’s compliance versus crack length relation, is proposed. The accuracy and potential drawbacks of this expression are investigated using FE simulations. Next, seven groups of ECT specimens are fabricated and tested. Each of these groups contains specimens with preimplanted inserts that are bounded by plies at different +q and -q orientations. The seven groups consist of values of q that vary from 0° to 90° in 15° increments. Tests on these specimens show that intralaminar cracking occurs in specimens from all batches except those for which q equals 15° or 30°. However, values of G(sub IIIc) measured using specimens with these two ply orientations were not equal and, for q = 30°, the values of G(sub IIIc) that were obtained were not completely independent of initial starter crack length. Potential issues accounting for these observations and other challenges associated with measuring G(sub IIIc) using the ECT test are discussed.

Polymer matrix composites↗

Laying a Foundation for Performance Assessment (PA) Model Development - 19267

Performance Assessment (PA) models are abstractions of real-world conditions. As abstractions, modelers must make a number of decisions regarding model complexity and which features, events, and processes (FEPs) will be represented. To ensure that such decisions are transparent to stakeholders, modelers should document their approach and how this approach influences conceptual model development. This paper describes one such approach. Examples are used to describe an analysis of the potential FEPs. Through the FEPs analysis, all potentially relevant FEPs can be identified. These potentially relevant FEPs are then used to develop a detailed conceptual model known as the Central Scenario, which includes a description of the assessment context, the key features of the site and the closure system, and the expected processes of the system. From this Central Scenario conceptual model, mathematical models can be developed and implemented within modeling software and used to demonstrate compliance to PA performance objectives. FEPs which are beyond the scope of the Central Scenario are identified and used as the basis for developing alternative conceptual models (ACMs) or sensitivity analyses. Once these models and modeling cases are defined, the necessary inputs can be identified and defined. (author)

97 MATHEMATICS AND COMPUTING↗

Energy Efficiency and Performance Evaluation of Self-Contained, Medium Temperature, Reach-In Refrigerated Display Cases

This project was part of an effort by Commonwealth Edison Company (ComEd) to evaluate the energy and peak demand saving potential of emerging technologies in the Chicago area. This document focuses on the assessment of energy-efficient, medium-temperature, self-contained refrigerated display cases utilizing environmentally friendly refrigerants. The results of this evaluation will be considered by CLEAResult to develop a new energy efficiency rebate measure for ComEd's incentive programs. This rebate measure will become an addition to the Technical Reference Manual (TRM). In 2016, the United Nations passed the Kigali Montreal Protocol Amendment which placed restrictions on certain types of refrigerants. In compliance with this amendment, the US Environmental Protection Agency (EPA) placed a ban on the manufacture of refrigeration systems using hydrofluorocarbons including R134a starting in January 2020. Although the ban has halted manufacture, the EPA continues to allow the use of these refrigerants. Therefore, it is critical to provide incentives for replacing these refrigerants with other environmentally friendly and energy-efficient alternatives. The energy-efficient refrigerator cases evaluated here (referred to as EE Case A and B) contain environmentally-friendly refrigerants in compliance with the EPA hydrofluorocarbon ban. These consist of natural refrigerant propane (R290), and HFC drop-in hydrofluoroolefin R513a, respectively. These cases also contain other energy-efficient components including efficient lighting, more robust evaporator and condenser fans and different-sized heat exchangers. EE Case A is also built with materials that better insulate the case, which improves energy efficiency. To ascertain the energy efficiency contribution of these design components, the consumption of the evaporator and condenser fan motors, compressor, and lighting/controller were evaluated individually. The medium-temperature, self-contained reach-in refrigerated display case was selected due to its widespread use in convenience stores and small supermarkets. Self-contained refrigeration has also seen increased use in restaurants due to curbside pickup during the COVID-19 pandemic. For this study, the refrigerated display cases' performance was evaluated in a controlled environmental chamber at representative indoor dry-bulb and humidity conditions found in supermarkets within ComEd's service territory climate zone. The test method used in this project was foundationally inspired by the ANSI/ASHRAE 72-2018 method of testing. However, modifications to the ANSI/ASHRAE test methodology were implemented to better represent customer operation of the units. In addition to the indoor supermarket conditions, the cases were also evaluated at the "upper target," or environmental conditions used in ANSI/ASHRAE 72-2018. The case total power and case components were metered to obtain their daily power (kW) and energy consumption(kWh). The cases were filled with thermal filler mass to replicate thermal mass of product loading. Additionally, product simulators were used to provide product temperature information. Door actuators were mounted to each of the cases' three doors to replicate regular door openings and effects of shopper traffic.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Why Perovskite Thermal Stress is Unaffected by Thin Contact Layers

Metal halide perovskite photovoltaics have emerged as a high efficiency, low-cost alternative that can potentially rival or enhance conventional silicon technology. Despite exceptional initial power conversion efficiencies, achieving compliance with international standards and widespread adoption requires further enhancements to their operational stability. Notably, addressing mechanical strain and stress in brittle perovskites has emerged as a pivotal approach to mitigate chemical degradation and improve reliability during thermal cycling. Here, in this study, a popularized strain engineering strategy is investigated in which a high coefficient of thermal expansion (CTE) hole transport layer (i.e., PDCBT) is cast onto inorganic perovskite (CsPbI 2 Br) at 100 °C. Contrary to previously published results, the X-ray diffraction (XRD):Sin 2 ψ and substrate curvature measurement techniques show that the hole transport layer has no discernible impact on perovskite strain. The accuracy of the XRD:Sin 2 ψ method for measuring strain is highlighted in contrast to an analysis based on shifts of single XRD peaks which can be influenced by multiple artifacts. The findings in this study are in accordance with mechanics theory: thin layers are unable to induce significant strain changes in perovskite thin films as the force they apply is negligible compared to that applied by a thick and stiff substrate.

14 SOLAR ENERGY↗

Influence of Business Models on PV-Battery Dispatch Decisions and Market Value

PV-battery hybrid projects dominate interconnection queues in some regions in the United States, but few projects have been operational long enough to assess how the hybrid capabilities may be used in practice. We interview plant operators and analyze empirical dispatch data for eleven large-scale PV-battery hybrids in three organized wholesale markets in the United States. We use the dispatch data and wholesale market prices to estimate the market value of our sample hybrids in 2020. The empirical increase in market value of a PV-battery hybrid relative to a standalone PV plant varies by project and ranges from $\$$1 to $\$$48/MWhsolar. The premium is driven by market, location, technical characteristics of the PV and battery asset, and battery dispatch strategies. In contrast to the widespread assumptions in the PV-battery hybrid modeling literature, only three of the eleven project operators optimize battery usage for wholesale market revenue as merchant plants. Instead, the majority of operators in the sample have alternate objectives. For example, load-serving entities target peak load reductions, incentive program participants focus on compliance with program requirements, and large energy consumers prioritize resiliency and utility bill minimization. Understanding prevalent dispatch signals and the degree of alignment with system-wide grid needs can increase the market value of PV-battery hybrids.

14 SOLAR ENERGY↗