Search NASA⌕ Search

SEARCH · Search NASA

Results for “APD”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 145 records · Page 8

Performance for GPU exceptions

Techniques for improving performance of accelerated processing devices (“APDs”) when exceptions occur are provided. In APDs, the very large number of parallel processing execution units, and the complexity of the hardware used to execute a large number of work-items in parallel, means that APDs typically stall when an exception occurs (unlike in central processing units (“CPUs”), which are able to execute speculatively and out-of-order). However, the techniques provided herein allow at least some execution to occur past exceptions. Execution past an exception generating instruction occurs by executing instructions that would not lead to a corruption while skipping those that would lead to a corruption. After the exception has been satisfied, execution occurs in a replay mode in which the potentially exception-generating instruction is executed and in which instructions that did not execute in the exception-wait mode are executed. A mask and counter are used to control execution in replay mode.

Gutierrez, Anthony T.↗

Avalanche photodiode and an optical receiver having the same

Examples described herein relate to an avalanche photodiode (APD) and an optical receiver including the APD. The APD may include a substrate and a photon absorption region disposed on the substrate. The substrate may include a charge carrier acceleration region under the photon absorption region; a charge region adjacent to the charge carrier acceleration region; and a charge carrier multiplication region adjacent to the charge region. The charge carrier acceleration region, the charge region, and the charge carrier multiplication region are laterally formed in the substrate. When a biasing voltage is applied to the optoelectronic device, photon-generated free charge carriers may be generated in the photon absorption region and are diffused into the charge carrier acceleration region. The charge carrier acceleration region is configured to accelerate the photon-generated free charge carriers prior to the photon-generated free charge carriers entering into the charge region and undergoing impact ionization in the charge carrier multiplication region.

Yuan, Yuan↗

Front-end Electronics for the ALICE Calorimeters

The ALICE calorimeters PHOS and EMCal are based on Avalanche Photo-Diode (APD) photosensors with Charge Sensitive Preamplifiers (CSP) for readout of the scintillating elements. The amplified signals are read out via 32-channel shaper/digitizer front-end electronics (FEE) with 14-bit effective dynamic range. The electronics is based on second order shapers with dual gain for each channel, getting digitized by ALTRO chips. Each APD channel is equipped with an individual 10-bit APD gain adjustment and 2 x 2 channel clusters generate a 100 ns shaped analog sums output (Fast OR) for the associated Trigger Region Units (TRU). The Fast OR signals are generated by first order shapers with a dynamic range of 12-bit given by the ADC in the TRU cards. Board controller firmware in the FPGA provides local monitoring and configuration of all parameters via the ALICE DCS system. The signal to noise ratio for MIP at 215 MeV is {approx}7 per channel with a noise level of 30 MeV at room temperature for a dynamic range of 80 GeV for PHOS, and the fast-OR RMS noise level is about 75 MeV for a dynamic range of 250 GeV for EMCal.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Reflectivity of VUV-sensitive silicon photomultipliers in liquid Xenon

Silicon photomultipliers are regarded as a very promising technology for next-generation, cutting-edge detectors for low-background experiments in particle physics. This work presents systematic reflectivity studies of Silicon Photomultipliers (SiPM) and other samples in liquid xenon at vacuum ultraviolet (VUV) wavelengths. A dedicated setup at the University of Münster has been used that allows to acquire angle-resolved reflection measurements of various samples immersed in liquid xenon with 0.45° angular resolution. Four samples are investigated in this work: one Hamamatsu VUV4 SiPM, one FBK VUV-HD SiPM, one FBK wafer sample and one Large-Area Avalanche Photodiode (LA-APD) from EXO-200. Here, the reflectivity is determined to be 25–36 % at an angle of incidence of 20° for the four samples and increases to up to 65 % at 70° for the LA-APD and the FBK samples. The Hamamatsu VUV4 SiPM shows a decline with increasing angle of incidence. The reflectivity results will be incorporated in upcoming light response simulations of the nEXO detector.

(pin diodes, APDs, SiPMs, G-APDs, CCDs, EBCCDs, EM↗

Genetic mapping of sugarcane aphid resistance in sorghum line SC112-14

Sugarcane aphid [Melanaphis sacchari (Zehntner)] is a destructive pest that has had an economic effect on sorghum in North America since 2013. The identification, development, and use of resistant sorghum germplasm is the most feasible strategy to control the pest. Nevertheless, the genetic control of sugarcane aphid (SCA) resistance is unknown for most sorghum resistant lines. To identify the genetic regions that confer SCA resistance in sorghum line SC112-14, 103 recombinant inbred lines (RILs) derived by its cross with the susceptible line PI 609251 were evaluated for their SCA resistance response in Georgia during two consecutive years. The resistance response was determined based on two ratings (2 wk apart) for aphid population size (APS) and aphid-induced plant damage (APD) each year. Segregation for SCA resistance was observed for the first APS and both APD ratings, and the broad-sense heritability estimate ranged from .71 to .76, respectively. A quantitative trait locus analysis using a high-density linkage map of 3,852 single nucleotide polymorphisms (SNPs) detected an 81-kb genomic region on chromosome 6 that explained 50–55% of the phenotypic variation. Comparative mapping analysis found that the resistance locus in SC112-14 is located 8- and 10-cM upstream of the Henong 16 (RMES1) and Tx2783 resistance loci, respectively, and encloses the SNP Sbv3.1_06_2316351 associated in Haitian resistant lines. Therefore, the line SC112-14 is an additional SCA resistance source that can be combined or strategically used with other resistance sources to assure a more robust host plant resistance to the SCA.

60 APPLIED LIFE SCIENCES↗

Enhancement of responsivity and speed in waveguide Ge/Si avalanche photodiode with separate vertical Ge absorption, lateral Si charge and multiplication configuration

Waveguide-coupled Ge/Si separate absorption, charge and multiplication avalanche photodiodes (SACM APDs) have shown significant potential as high-sensitivity, low-noise, and high-speed photo-detection for optical communications. Here we present a nanoscale single-mode waveguide-integrated vertical Ge absorption, lateral Si charge and single multiplication configuration for a waveguide Ge/Si SACM APD. This device can achieve 90% absorption at 1550 nm wavelengths with a 10 μm-long Ge layer. The device exhibits a seven times reduction in device length compared to conventional waveguide structures and a 29% increase compared to multi-mode interference coupling. Meanwhile, a 3-dB bandwidth can achieve 47 GHz, which is five times higher than the conventional vertical Ge absorption, lateral Si charge and multiplication devices.

77 NANOSCIENCE AND NANOTECHNOLOGY↗

The growth of GaSb/Al{sub 0.33}Ga{sub 0.67}Sb MQW on n-Silicon (1 0 0) with Al{sub 0.66}Ga{sub 0.34}Sb/AlSb SPS layers

Highlights: • GaSb/Al{sub 0.33}GaSb MQW layer was grown on Si (1 0 0) by MBE. • The effect of miscut angle of Si substrate was studied. • A lot of twins were removed by Al{sub 0.66}Ga{sub 0.34}Sb/AlSb SPS layers. • Good quality of GaSb/Al{sub 0.33}Ga{sub 0.67}Sb MQW layers were proved by PL spectra. • Optimum growth temperature of the AlSb buffer layer was studied. - Abstract: GaSb/Al{sub 0.33}Ga{sub 0.67}Sb multi-quantum well (MQW) film on n-Si (1 0 0) substrates is grown by molecular beam epitaxy. The effects of a miscut angle of the Si substrate (0°, 5°, and 7°) on the properties of an AlSb layer were also studied. The suppression of the anti-phase domains (APD) was observed at a miscut angle of 5° on Si (1 0 0). It was found that the growth temperature in the range of 510–670 °C affects the quality of AlSb layers on Si. Low root-mean-square surface (RMS) roughness values of 3–5 nm were measured by atomic force microscopy at growth temperatures ranging from 550 °C to 630 °C. In addition, Al{sub 0.66}Ga{sub 0.34}Sb/AlSb short period superlattice (SPS) layers were used to overcome problems associated with a large lattice mismatch. The RMS values of samples with a SPS were partially measured at approximately ∼1 nm, showing a larger APD surface area than samples without a SPS layer. Bright-field cross-sectional transmission electron microscopy images of the GaSb/Al{sub 0.33}Ga{sub 0.67}Sb MQW, the AlSb buffer layer and the Al{sub 0.66}Ga{sub 0.34}Sb/AlSb SPS layers show that numerous twins from the AlSb/Si interface were removed by the AlSb buffer layer and the Al{sub 0.66}Ga{sub 0.34}Sb/AlSb SPS. The GaSb/Al{sub 0.33}Ga{sub 0.67}Sb MQW PL spectra were obtained at 300 K and 10 K with a fixed excitation power of 103 mW. Emission peaks appeared at 1758 nm and 1620 nm, respectively.

36 MATERIALS SCIENCE↗

Characterization of a New Charge Sensitive Preamplifier (CSP) for the Electromagnetic Calorimeters of the ALICE Experiment

The ALICE calorimeters PHOS and EMCal (including its extension DCal) are based on Avalanche Photo-Diode (APD) photosensors with Charge Sensitive Preamplifiers (CSPs) for readout of the scintillating elements. A new CSP has been developed on the basis of the design of the PHOS CSP, but modified to meet the requirements of the EMCal and DCal. Modifications were made specifically for a different APD choice with different characteristics, and also with the goals of less noise, faster rise time, and reduced cost. This paper presents a detailed description of the new CSP features and the test results.

99 GENERAL AND MISCELLANEOUS↗

Bias-dependent displacement damage effects in a silicon avalanche photodiode

Radiation effects studies on a commercial beveled-edge avalanche photodiode (APD) showed that applying reverse bias to the device during irradiation enhanced the severity of apparent damage. Proton microbeam irradiations were made using a proton beam energy of 2 MeV and fluence ranging from 2.0 × 10 10 to 5.1 × 10 12 cm -2 . Charge collection measurements using the ion beam induced charge (IBIC) technique showed that relative losses increased by up to an order of magnitude when the reverse bias applied during irradiation increased from 50 to 1500 V. The presence of reverse bias also led to equivalent losses in charge collection that would only be seen in irradiations with an order of magnitude higher fluence in unbiased APDs. The results demonstrate that bias-enhanced irradiation damage is insufficiently understood and must be accounted for in characterizations of radiation effects.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Alpha B-crystallin prevents the arrhythmogenic effects of particulate matter isolated from ambient air by attenuating oxidative stress

Ca{sup 2+}/calmodulin-dependent protein kinase II (CaMKII) is activated by particulate matter (PM) isolated from ambient air and linked to prolonged repolarization and cardiac arrhythmia. We evaluated whether alpha B-crystallin (CryAB), a heat shock protein, could prevent the arrhythmogenic effects of PM by preventing CaMKII activation. CryAB was delivered into cardiac cells using a TAT-protein transduction domain (TAT-CryAB). ECGs were measured before and after tracheal exposure of diesel exhaust particles (DEP) and each intervention in adult Sprague–Dawley rats. After endotracheal exposure of DEP (200 μg/mL for 30 minutes, n = 11), QT intervals were prolonged from 115 ± 14 ms to 144 ± 20 ms (p = 0.03), and premature ventricular contractions were observed more frequently (0% vs. 44%) than control (n = 5) and TAT-Cry (n = 5). However, DEP-induced arrhythmia was not observed in TAT-CryAB (1 mg/kg) pretreated rats (n = 5). In optical mapping of Langendorff-perfused rat heats, compared with baseline, DEP infusion of 12.5 μg/mL (n = 12) increased apicobasal action potential duration (APD) differences from 2 ± 6 ms to 36 ± 15 ms (p < 0.001), APD restitution slope from 0.26 ± 0.07 to 1.19 ± 0.11 (p < 0.001) and ventricular tachycardia (VT) from 0% to 75% (p < 0.001). DEP infusion easily induced spatially discordant alternans. However, the effects of DEP were prevented by TAT-CryAB (1 mg/kg, n = 9). In rat myocytes, while DEP increased reactive oxygen species (ROS) generation and phosphated CaMKII, TAT-CryAB prevented these effects. In conclusion, CryAB, a small heat shock protein, might prevent the arrhythmogenic effects of PM by attenuating ROS generation and CaMKII activation. -- Highlights: ► Particulate matter (PM) increases arrhythmia. ► PM induced arrhythmias are related with oxidative stress and CaMKII activation. ► Alpha B-crystallin (CryAB) could attenuate the arrhythmogenic effect of PM. ► CryAB decreases oxidative stress and CaMKII activation induced by ambient PM.

60 APPLIED LIFE SCIENCES↗

High level of oxygen treatment causes cardiotoxicity with arrhythmias and redox modulation

Hyperoxia exposure in mice leads to cardiac hypertrophy and voltage-gated potassium (Kv) channel remodeling. Because redox balance of pyridine nucleotides affects Kv function and hyperoxia alters cellular redox potential, we hypothesized that hyperoxia exposure leads to cardiac ion channel disturbances and redox changes resulting in arrhythmias. In the present study, we investigated the electrical changes and redox abnormalities caused by 72 h hyperoxia treatment in mice. Cardiac repolarization changes were assessed by acquiring electrocardiogram (ECG) and cardiac action potentials (AP). Biochemical assays were employed to identify the pyridine nucleotide changes, Kv1.5 expression and myocardial injury. Hyperoxia treatment caused marked bradycardia, arrhythmia and significantly prolonged (ms) the, RR (186.2 ± 10.7 vs. 146.4 ± 6.2), PR (46.8 ± 3.1 vs. 39.3 ± 1.6), QRS (10.8 ± 0.6 vs. 8.5 ± 0.2), QTc (57.1 ± 3.5 vs. 40 ± 1.4) and JT (13.4 ± 2.1 vs. 7.0 ± 0.5) intervals, when compared with normoxia group. Hyperoxia treatment also induced significant increase in cardiac action potential duration (APD) (ex-APD{sub 90}; 73.8 ± 9.5 vs. 50.9 ± 3.1 ms) and elevated levels of serum markers of myocardial injury; cardiac troponin I (TnI) and lactate dehydrogenase (LDH). Hyperoxia exposure altered cardiac levels of mRNA/protein expression of; Kv1.5, Kvβ subunits and SiRT1, and increased ratios of reduced pyridine nucleotides (NADH/NAD and NADPH/NADP). Inhibition of SiRT1 in H9C2 cells using Splitomicin resulted in decreased SiRT1 and Kv1.5 expression, suggesting that SiRT1 may mediate Kv1.5 downregulation. In conclusion, the cardiotoxic effects of hyperoxia exposure involve ion channel disturbances and redox changes resulting in arrhythmias. - Highlights: • Hyperoxia treatment leads to arrhythmia with prolonged QTc and action potential duration. • Hyperoxia treatment alters cardiac pyridine nucleotide [NAD(P)H/NAD(P)] levels. • SiRT1 and Kv1.5 are co-regulated in hyperoxic heart injury. • Hyperoxia may lead to cardiotoxicity.

60 APPLIED LIFE SCIENCES↗

Long‐Term Impacts of Global Solid Biofuel Emissions on Ambient Air Quality and Human Health for 2000–2019

Globally, solid biofuels (SB) have been widely used for household cooking and energy production for decades due to electricity shortages and socio-economic barriers to adopting renewable energy alternatives. This has detrimental effects on air quality, human health, and climate through trace gas and aerosol emissions. Despite numerous studies, the long-term consequences of SB emissions remain poorly understood. Here, we use the Community Earth System Model and the Community Emissions Data System emission inventory to investigate the SB emission impacts on air quality and human health for 2000–2019. Global SB emission increased the ambient PM 2.5 (particulate matter with aerodynamic diameters ≤2.5 μm) and ozone (O 3 ) concentrations up to 23.61 μg/m 3 and 13.69 ppbv, with significant effects found in India, China, and the Rest of Asia (ROA). Our study estimates total annual premature deaths (APDs) associated with global SB-attributable PM 2.5 and O 3 exposure as 1.11 million [95% confidence interval (95% CI): 1.00–1.22 million] in 2000 up to 1.43 million (95% CI: 1.30–1.56 million) in 2019. China's SB emissions and associated APDs have reduced substantially, whereas India and ROA had a major leap in both estimates in 2019 compared to 2000. China's progress in cutting residential SB emissions accounts for its improvements. Our study urges the reduction of SB usage and emissions to potentially improve overall air quality and human health conditions, especially in highly populated, low- and middle-income countries, where the poor air quality and associated health burden attributable to SB emissions are estimated to be higher.

O 3↗

Ultralow noise midwave infrared InAs-GaSb strain layer superlattice avalanche photodiode

Eye-safe midwavelength infrared InAs-GaSb strain layer superlattice p{sup +}-n{sup -}-n homojunction avalanche photodiodes (APDs) grown by solid source molecular beam epitaxy were fabricated and characterized. Maximum multiplication gain of 1800 was measured at -20 V at 77 K. Excess noise factors between 0.8 and 1.2 were measured up to gain of 300. Gain of 200 was measured at 120 K. Exponential nature of the gain as a function of reverse bias along with low excess noise factor at higher gain confirms single carrier electron-only impact ionization in the avalanche regime. Decrease in the multiplication gain at higher temperatures correlates with standard APD characteristics.

36 MATERIALS SCIENCE↗

Avalanche photodiode based detector for beam emission spectroscopy

An avalanche photodiode based (APD) detector for the visible wavelength range was developed for low light level, high frequency beam emission spectroscopy (BES) experiments in fusion plasmas. This solid state detector has higher quantum efficiency than photomultiplier tubes, and unlike normal photodiodes, it has internal gain. This paper describes the developed detector as well as the noise model of the electronic circuit. By understanding the noise sources and the amplification process, the optimal amplifier and APD reverse voltage setting can be determined, where the signal-to-noise ratio is the highest for a given photon flux. The calculations are compared to the absolute calibration results of the implemented circuit. It was found that for a certain photon flux range, relevant for BES measurements ({approx_equal}10{sup 8}-10{sup 10} photons/s), the new detector is superior to both photomultipliers and photodiodes, although it does not require cryogenic cooling of any component. The position of this photon flux window sensitively depends on the parameters of the actual experimental implementation (desired bandwidth, detector size, etc.) Several detector units based on these developments have been built and installed in various tokamaks. Some illustrative results are presented from the 8-channel trial BES system installed at Mega-Ampere Spherical Tokamak (MAST) and the 16-channel BES system installed at the Torus Experiment for Technology Oriented Research (TEXTOR).

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Synchrotron radiation-based Mössbauer spectra of {sup 174}Yb measured with internal conversion electrons

A detection system for synchrotron-radiation (SR)-based Mössbauer spectroscopy was developed to enhance the nuclear resonant scattering counting rate and thus increase the available nuclides. In the system, a windowless avalanche photodiode (APD) detector was combined with a vacuum cryostat to detect the internal conversion (IC) electrons and fluorescent X-rays accompanied by nuclear de-excitation. As a feasibility study, the SR-based Mössbauer spectrum using the 76.5 keV level of {sup 174}Yb was observed without {sup 174}Yb enrichment of the samples. The counting rate was five times higher than that of our previous system, and the spectrum was obtained within 10 h. This result shows that nuclear resonance events can be more efficiently detected by counting IC electrons for nuclides with high IC coefficients. Furthermore, the windowless detection system enables us to place the sample closer to the APD elements and is advantageous for nuclear resonant inelastic scattering measurements. Therefore, this detection system can not only increase the number of nuclides accessible in SR-based Mössbauer spectroscopy but also allows the nuclear resonant inelastic scattering measurements of small single crystals or enzymes with dilute probe nuclides that are difficult to measure with the previous detection system.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Impact ionization in Al{sub x}Ga{sub 1−x}As{sub y}Sb{sub 1−y} avalanche photodiodes

Avalanche photodiodes (APDs) have been fabricated in order to determine the impact ionization coefficients of electrons (α) and holes (β) in Al{sub x}Ga{sub 1−x}As{sub y}Sb{sub 1−y} lattice matched to GaSb for three alloy compositions: (x = 0.40, y = 0.035), (x = 0.55, y = 0.045), and (x = 0. 65, y = 0.054). The impact ionization coefficients were calculated from photomultiplication measurements made on specially designed APDs, which allowed for both pure electron and pure hole injection in the same device. Photo-multiplication measurements were made at temperatures ranging from 77 K to 300 K for all three alloys. A quasi-physical model with an explicit temperature dependence was used to express the impact ionization coefficients as a function of electric-field strength and temperature. For all three alloys, it was found that α < β at any given temperature. In addition, the values of the impact ionization coefficients were found to decrease as the aluminum concentration of the AlGaAsSb alloy was increased. A value between 1.2 and 4.0 was found for β/α, which is dependent on temperature, alloy composition, and electric-field strength.

36 MATERIALS SCIENCE↗

Nuclear resonant scattering measurements on {sup 57}Fe by multichannel scaling with a 64-pixel silicon avalanche photodiode linear-array detector

We developed a silicon avalanche photodiode (Si-APD) linear-array detector for use in nuclear resonant scattering experiments using synchrotron X-rays. The Si-APD linear array consists of 64 pixels (pixel size: 100 × 200 μm{sup 2}) with a pixel pitch of 150 μm and depletion depth of 10 μm. An ultrafast frontend circuit allows the X-ray detector to obtain a high output rate of >10{sup 7} cps per pixel. High-performance integrated circuits achieve multichannel scaling over 1024 continuous time bins with a 1 ns resolution for each pixel without dead time. The multichannel scaling method enabled us to record a time spectrum of the 14.4 keV nuclear radiation at each pixel with a time resolution of 1.4 ns (FWHM). This method was successfully applied to nuclear forward scattering and nuclear small-angle scattering on {sup 57}Fe.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Combined hydrogen and lithium beam emission spectroscopy observation system for Korea Superconducting Tokamak Advanced Research

A novel beam emission spectroscopy observation system was designed, built, and installed onto the Korea Superconducting Tokamak Advanced Research tokamak. The system is designed in a way to be capable of measuring beam emission either from a heating deuterium or from a diagnostic lithium beam. The two beams have somewhat complementary capabilities: edge density profile and turbulence measurement with the lithium beam and two dimensional turbulence measurement with the heating beam. Two detectors can be used in parallel: a CMOS camera provides overview of the scene and lithium beam light intensity distribution at maximum few hundred Hz frame rate, while a 4 × 16 pixel avalanche photo-diode (APD) camera gives 500 kHz bandwidth data from a 4 cm × 16 cm region. The optics use direct imaging through lenses and mirrors from the observation window to the detectors, thus avoid the use of costly and inflexible fiber guides. Remotely controlled mechanisms allow adjustment of the APD camera’s measurement location on a shot-to-shot basis, while temperature stabilized filter holders provide selection of either the Doppler shifted deuterium alpha or lithium resonance line. The capabilities of the system are illustrated by measurements of basic plasma turbulence properties.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗