Search NASA⌕ Search

SEARCH · Search NASA

Results for “ATTENUATION”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 145 records · Page 8

Fibroblast growth factor 21 attenuates hypoxia-induced pulmonary hypertension by upregulating PPARγ expression and suppressing inflammatory cytokine levels

Highlights: • FGF21 Attenuates Hypoxia-induced Pulmonary Hypertension as a Potential drug. • FGF21 may Inhibit Vascular Remodeling Through Suppressing PASMCs Proliferation. • FGF21 Upregulates PPARγ Expression and Inhibits Inflammatory Cytokines. Hypoxia-induced pulmonary hypertension (HPH) is a progressive disease characterized by a sustained, elevated pulmonary arterial pressure and vascular remodeling. The latter pathogenesis mainly involves overproliferation of pulmonary artery smooth muscle cells (PASMCs). Fibroblast growth factor 21 (FGF21) has recently emerged as a novel regulator that prevents cardiac hypertrophic remodeling. However, its possible role in pulmonary remodeling remains unclear. The activation of peroxisome proliferator activated receptor γ (PPARγ) is reported to attenuate HPH by suppressing proliferative signals. Loss of PPARγ in the lung contributes to abnormal proliferation of PASMCs. FGF21 is a key regulator of PPARγ activity in adipocytes, but its role has not been elucidated in PASMCs. Therefore, we hypothesized that FGF21 may confer therapeutic effects in HPH by upregulating the expression of PPARγ. Sprague-Dawley rats were exposed to hypoxia and treated with FGF21 for 4 weeks. In parallel, hypoxic conditions and FGF21 were administered to rat PASMCs for 48 h. FGF21 attenuated the hypoxia-induced elevation in mean pulmonary arterial pressure (mPAP), right ventricular hypertrophy (RVH), medial thickening and overproliferation of PASMCs. Furthermore, FGF21 abrogated the reductions in PPARγ expression and increases in TNF-α, IL-1 and IL-6 levels in PASMC culture media. Collectively, these results demonstrate that FGF21 could potentially attenuate the pathogenic derangements of HPH by targeting PPARγ and inflammatory cytokines.

60 APPLIED LIFE SCIENCES↗

Escherichia coli Attenuation by Fe Electrocoagulation in Synthetic Bengal Groundwater: Effect of pH and Natural Organic Matter

Technologies addressing both arsenic and microbial contamination of Bengal groundwater are needed. Fe electrocoagulation (Fe-EC), a simple process relying on the dissolution of an Fe(0) anode to produce Fe(III) precipitates, has been shown to efficiently remove arsenic from groundwater at low cost. In this work, we investigated Escherichia coli (E. coli) attenuation by Fe-EC in synthetic Bengal groundwater as a function of Fe dosage rate, total Fe dosed, pH, and presence of natural organic matter (NOM). A 2.5 mM Fe dosage simultaneously achieved over 4-log E. coli attenuation and arsenic removal from 450 to below 10 μg/L. E. coli reduction was significantly enhanced at pH 6.6 compared to pH 7.5, which we linked to the decreased rate of Fe(II) oxidation at lower pH. 3 mg/L-C of NOM (Suwanee River fulvic acid) did not significantly affect E. coli attenuation. Live-dead staining and comparisons of Fe-EC with chemical coagulation controls showed that the primary mechanism of E. coli attenuation is physical removal with Fe(III) precipitates, with inactivation likely contributing as well at lower pH. Transmission electron microscopy showed that EC precipitates adhere to and bridge individual E. coli cells, resulting in large bacteria-Fe aggregates that can be removed by gravitational settling. Our results point to the promising ability of Fe-EC to treat arsenic and bacterial contamination simultaneously at low cost.

54 ENVIRONMENTAL SCIENCES↗

Simultaneous attenuation of trace organics and change in organic matter composition in the hyporheic zone of urban streams

Trace organic compounds (TrOCs) enter rivers with discharge of treated wastewater. These effluents can contain high loads of dissolved organic matter (DOM). In a 48 h field study, we investigated changes in molecular composition of seven DOM compound classes (FTICR-MS) and attenuation of 17 polar TrOCs in a small urban stream receiving treated wastewater. Correlations between TrOCs and DOM were used to identify simultaneous changes in surface water and the hyporheic zone. Changes in TrOC concentrations in surface water ranged between a decrease of 29.2% for methylbenzotriazole and an increase of 152.2% for the transformation product gabapentin-lactam. In the hyporheic zone, only decreasing TrOC concentrations were observed, ranging from 4.9% for primidone to 93.8% for venlafaxine . TrOC attenuation coincided with a decline of molecular diversity of easily biodegradable DOM compound classes while molecular diversity of poorly biodegradable DOM compound classes increased. This concurrence indicates similar or linked attenuation pathways for biodegradable DOM and TrOCs. Strong correlations between TrOCs and DOM compound classes as well as high attenuation of TrOCs primarily occurred in the hyporheic zone. This suggests high potential for DOM turnover and TrOC mitigation in rivers if hyporheic exchange is sufficient.

54 ENVIRONMENTAL SCIENCES↗

Incorporating Beam Attenuation Calculations into an Integrated Data Analysis Model for Ion Effective Charge

Here, we have created a forward model for charge-exchange impurity density measurements that incorporates neutral beam attenuation measurements self-consistently for the purpose of determining the ion-effective charge Z eff . The model is constructed within an integrated data analysis framework to include a self-consistent calculation of neutral beam attenuation due to multiple impurity species into the measurement of a single impurity density. The model includes measurements of the beam Doppler-shift spectrum and shine-through particle flux to determine the neutral beam particle density which is attenuated by ion collisions. Synthetic data are generated from the diagnostic forward model using statistical and calibration uncertainties. These “noisy” data are used in the analysis to evaluate how accurately Z eff is determined. Methods of experimental design are employed to calculate the information gained from different diagnostic combinations. The analysis shows that while attenuation measurements alone do not provide a unique impurity density measurement in the case of a multispecies inhomogeneous plasma, they do provide an effective measurement of the Z eff profile and place constraints on the impurity density profiles.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

The MOSDEF Survey: Measurements of Balmer decrements and the dust attenuation curve at Redshifts z ∼ 1.4–2.6

We present results on the dust attenuation curve of z ∼ 2 galaxies using early observations from the MOSFIRE Deep Evolution Field survey. Our sample consists of 224 star-forming galaxies with z{sub spec} = 1.36–2.59 and high signal-to-noise ratio measurements of Hα and Hβ obtained with Keck/MOSFIRE. We construct composite spectral energy distributions (SEDs) of galaxies in bins of Balmer decrement to measure the attenuation curve. We find a curve that is similar to the SMC extinction curve at λ ≳ 2500 Å. At shorter wavelengths, the shape is identical to that of the Calzetti et al. relation, but with a lower normalization. Hence, the new attenuation curve results in star formation rates (SFRs) that are ≈20% lower, and stellar masses that are Δlog(M{sup ∗}/M{sub ⊙})≃0.16 dex lower, than those obtained with the Calzetti relation. We find that the difference in the total attenuation of the ionized gas and stellar continuum correlates strongly with SFR, such that for dust-corrected SFRs ≳ 20 M{sub ⊙} yr{sup −1}, assuming a Chabrier initial mass function, the nebular emission lines suffer an increasing degree of obscuration relative to the continuum. A simple model that can account for these trends is one in which the UV through optical stellar continuum is dominated by a population of less-reddened stars, while the nebular line and bolometric luminosities become increasingly dominated by dustier stellar populations for galaxies with large SFRs, as a result of the increased dust enrichment that accompanies such galaxies. Consequently, UV- and SED-based SFRs may underestimate the total SFR at even modest levels of ≈20 M{sub ⊙} yr{sup −1}.

79 ASTRONOMY AND ASTROPHYSICS↗

The dust attenuation curve versus stellar mass for emission line galaxies at z ∼ 2

We derive the mean wavelength dependence of stellar attenuation in a sample of 239 high redshift (1.90<z<2.35) galaxies selected via Hubble Space Telescope WFC3 IR grism observations of their rest-frame optical emission lines. Our analysis indicates that the average reddening law follows a form similar to that derived by Calzetti et al. for local starburst galaxies. However, over the mass range 7.2≲logM/M{sub ⊙}≲10.2, the slope of the attenuation law in the ultraviolet (UV) is shallower than that seen locally, and the UV slope steepens as the mass increases. These trends are in qualitative agreement with Kriek and Conroy, who found that the wavelength dependence of attenuation varies with galaxy spectral type. However, we find no evidence of an extinction “bump” at 2175 Å in any of the three stellar mass bins, or in the sample as a whole. We quantify the relation between the attenuation curve and stellar mass and discuss its implications.

79 ASTRONOMY AND ASTROPHYSICS↗

Urocortin-2 improves right ventricular function and attenuates pulmonary arterial hypertension

Abstract Aims Pulmonary arterial hypertension (PAH) is a devastating disease and treatment options are limited. Urocortin-2 (Ucn-2) has shown promising therapeutic effects in experimental and clinical left ventricular heart failure (HF). Our aim was to analyse the expression of Ucn-2 in human and experimental PAH, and to investigate the effects of human Ucn-2 (hUcn-2) administration in rats with monocrotaline (MCT)-induced pulmonary hypertension (PH). Methods and results Tissue samples were collected from patients with and without PAH and from rats with MCT-induced PH. hUcn-2 (5 μg/kg, bi-daily, i.p., for 10 days) or vehicle was administered to male wistar rats subjected to MCT injection or to pulmonary artery banding (PAB) to induce right ventricular (RV) overload without PAH. Expression of Ucn-2 and its receptor was increased in the RV of patients and rats with PAH. hUcn-2 treatment reduced PAH in MCT rats, resulting in decreased morbidity, improved exercise capacity and attenuated pulmonary arterial and RV remodelling and dysfunction. Additionally, RV gene expression of hypertrophy and failure signalling pathways were attenuated. hUcn-2 treatment also attenuated PAB-induced RV hypertrophy. Conclusions Ucn-2 levels are altered in human and experimental PAH. hUcn-2 treatment attenuates PAH and RV dysfunction in MCT-induced PH, has direct anti-remodelling effects on the pressure-overloaded RV, and improves pulmonary vascular function.

Adão, Rui↗

A viscoelastic model for seismic attenuation using fractal mechanical networks

SUMMARY Seismic attenuation (quantified by the quality factor Q) has a significant impact on the seismic waveforms, especially in the fluid-saturated rocks. This dissipative process can be phenomenologically represented by viscoelastic models. Previous seismological studies show that the Q value of Earth media exhibits a nearly frequency-independent behaviour (often referred to as constant-Q in literature) in the seismic frequency range. Such attenuation can be described by the mathematical Kjartansson constant-Q model, which lacks of a physical representation in the viscoelastic sense. Inspired by the fractal nature of the pore fluid distribution in patchy-saturated rocks, here we propose two fractal mechanical network (FMN) models, that is, a fractal tree model and a quasi-fractal ladder model, to phenomenologically represent the frequency-independent Q behaviour. As with the classic viscoelastic models, the FMN models are composed of mechanical elements (spring and dashpots) arranged in different hierarchical patterns. A particular parametrization of each model can produce the same complex modulus as in the Kjartansson model, which leads to the constant-Q. Applying the theory to several typical rock samples, we find that the seismic attenuation signature of these rocks can be accurately represented by either one of the FMN models. Besides, we demonstrate that the ladder model in particular exhibits the realistic multiscale fractal structure of the saturated rocks. Therefore, the FMN models as a proxy could provide a new way to estimate the microscopic rock structure property from macroscopic seismic attenuation observation.

Geochemistry & Geophysics↗

Strong increase in ultrasound attenuation below T c in Sr 2 RuO 4 : Possible evidence for domains

Recent experiments suggest that Sr 2 RuO 4 has a two-component superconducting order parameter (OP). A two-component OP has multiple degrees of freedom in the superconducting state that can result in low-energy collective modes or the formation of domain walls—a possibility that would explain a number of experimental observations including the smallness of the signature of time reversal symmetry breaking at T c and telegraph noise in critical current experiments. We use resonant ultrasound spectroscopy to perform ultrasound attenuation measurements across the superconducting T c of Sr 2 RuO 4 . We find that compressional sound attenuation increases by a factor of 7 immediately below T c , in sharp contrast with what is found in both conventional (s-wave) and high-T c (d-wave) superconductors. Our observations are most consistent with the presence of domain walls that separate different configurations of the superconducting OP. Here, the fact that we only observe an increase in sound attenuation for compressional strains, and not for shear strains, suggests an inhomogeneous superconducting state formed of two distinct, accidentally degenerate superconducting OPs that are not related to each other by symmetry. Whatever the mechanism, a factor of 7 increase in sound attenuation is a singular characteristic that must be reconciled with any potential theory of superconductivity in Sr 2 RuO 4 .

36 MATERIALS SCIENCE↗

Filamentation effect in a gas attenuator for high-repetition-rate X-ray FELs

A sustained filamentation or density depression phenomenon in an argon gas attenuator servicing a high-repetition femtosecond X-ray free-electron laser has been studied using a finite-difference method applied to the thermal diffusion equation for an ideal gas. A steady-state solution was obtained by assuming continuous-wave input of an equivalent time-averaged beam power and that the pressure of the entire gas volume has reached equilibrium. Both radial and axial temperature/density gradients were found and describable as filamentation or density depression previously reported for a femtosecond optical laser of similar attributes. The effect exhibits complex dependence on the input power, the desired attenuation, and the geometries of the beam and the attenuator. Time-dependent simulations were carried out to further elucidate the evolution of the temperature/density gradients in between pulses, from which the actual attenuation received by any given pulse can be properly calculated.

Feng, Yiping↗

Attenuation-based size metric for estimating organ dose to patients undergoing tube current modulated CT exams

Purpose: Task Group 204 introduced effective diameter (ED) as the patient size metric used to correlate size-specific-dose-estimates. However, this size metric fails to account for patient attenuation properties and has been suggested to be replaced by an attenuation-based size metric, water equivalent diameter (D{sub W}). The purpose of this study is to investigate different size metrics, effective diameter, and water equivalent diameter, in combination with regional descriptions of scanner output to establish the most appropriate size metric to be used as a predictor for organ dose in tube current modulated CT exams. Methods: 101 thoracic and 82 abdomen/pelvis scans from clinically indicated CT exams were collected retrospectively from a multidetector row CT (Sensation 64, Siemens Healthcare) with Institutional Review Board approval to generate voxelized patient models. Fully irradiated organs (lung and breasts in thoracic scans and liver, kidneys, and spleen in abdominal scans) were segmented and used as tally regions in Monte Carlo simulations for reporting organ dose. Along with image data, raw projection data were collected to obtain tube current information for simulating tube current modulation scans using Monte Carlo methods. Additionally, previously described patient size metrics [ED, D{sub W}, and approximated water equivalent diameter (D{sub Wa})] were calculated for each patient and reported in three different ways: a single value averaged over the entire scan, a single value averaged over the region of interest, and a single value from a location in the middle of the scan volume. Organ doses were normalized by an appropriate mAs weighted CTDI{sub vol} to reflect regional variation of tube current. Linear regression analysis was used to evaluate the correlations between normalized organ doses and each size metric. Results: For the abdominal organs, the correlations between normalized organ dose and size metric were overall slightly higher for all three differently (global, regional, and middle slice) reported D{sub W} and D{sub Wa} than they were for ED, but the differences were not statistically significant. However, for lung dose, computed correlations using water equivalent diameter calculated in the middle of the image data (D{sub W,middle}) and averaged over the low attenuating region of lung (D{sub W,regional}) were statistically significantly higher than correlations of normalized lung dose with ED. Conclusions: To conclude, effective diameter and water equivalent diameter are very similar in abdominal regions; however, their difference becomes noticeable in lungs. Water equivalent diameter, specifically reported as a regional average and middle of scan volume, was shown to be better predictors of lung dose. Therefore, an attenuation-based size metric (water equivalent diameter) is recommended because it is more robust across different anatomic regions. Additionally, it was observed that the regional size metric reported as a single value averaged over a region of interest and the size metric calculated from a single slice/image chosen from the middle of the scan volume are highly correlated for these specific patient models and scan types.

60 APPLIED LIFE SCIENCES↗

Single-shot Z eff dense plasma diagnostic through simultaneous refraction and attenuation measurements with a Talbot–Lau x-ray moiré deflectometer

The Talbot–Lau x-ray moiré deflectometer is a powerful plasma diagnostic capable of delivering simultaneous refraction and attenuation information through the accurate detection of x-ray phase shift and intensity. The diagnostic can provide the index of refraction n = 1 - δ + iβ of an object (dense plasma, for example) placed in the x-ray beam by independently measuring both δ and β, which are directly related to the electron density ne and the attenuation coefficient μ, respectively. Since δ and β depend on the effective atomic number Z eff , a map can be obtained from the ratio between phase and absorption images acquired in a single shot. The Talbot–Lau x-ray moiré deflectometer and its corresponding data acquisition and processing are briefly described to illustrate how the above is achieved; Z eff values of test objects within the 4–12 range were obtained experimentally through simultaneous refraction and attenuation measurements. We show that Z eff mapping of objects does not require previous knowledge of sample length or shape. The determination of Z eff from refraction and attenuation measurements with Moiré deflectometry could be of high interest to various domains of HED research, such as shocked materials and ICF experiments, as well as material science and NDT.

47 OTHER INSTRUMENTATION↗

Contaminant Attenuation and Transport Characterization of 200-UP-1 Operable Unit Sediment Samples

Contaminants disposed of at the land surface migrate through the vadose zone, forming plumes in groundwater. Processes that occur in the groundwater can attenuate contaminant concentrations during transport through the aquifer. For this reason, quantifying contaminant attenuation and contaminant transport processes in the aquifer, in support of the conceptual site model (CSM) and fate and transport modeling, are important for assessing the need for, and type of, remediation in the groundwater, including monitored natural attenuation (MNA). The framework to characterize attenuation and transport processes provided in U.S. Environmental Protection Agency (EPA) guidance documents was used to guide the laboratory effort reported herein.

54 ENVIRONMENTAL SCIENCES↗

An in situ measurement of the radio-frequency attenuation in ice at Summit Station, Greenland

We report an in situ measurement of the electric field attenuation length Lα at radio frequencies for the bulk ice at Summit Station, Greenland, made by broadcasting radio-frequency signals vertically through the ice and measuring the relative power in the return ground bounce signal. We find the depth-averaged field attenuation length to be < L α > = 947$^{+92}_{–85}$ m at 75 MHz. Here, while this measurement has clear radioglaciological applications, the radio clarity of the ice also has implications for the detection of ultra-high energy (UHE) astrophysical particles via their radio emission in dielectric media such as ice. Assuming a reliable extrapolation to higher frequencies, the measured attenuation length at Summit Station is comparable to previously measured radio-frequency attenuation lengths at candidate particle detector sites around the world, and strengthens the case for Summit Station as a promising northern site for UHE neutrino detection.

54 ENVIRONMENTAL SCIENCES↗

Breaking the curve with candels: a Bayesian approach to reveal the non-universality of the dust-attenuation law at high redshift

Dust attenuation affects nearly all observational aspects of galaxy evolution, yet very little is known about the form of the dust-attenuation law in the distant universe. Here, we model the spectral energy distributions of galaxies at z ∼ 1.5–3 from CANDELS with rest-frame UV to near-IR imaging under different assumptions about the dust law, and compare the amount of inferred attenuated light with the observed infrared (IR) luminosities. Some individual galaxies show strong Bayesian evidence in preference of one dust law over another, and this preference agrees with their observed location on the plane of infrared excess (IRX, L{sub TIR}/L{sub UV}) and UV slope (β). We generalize the shape of the dust law with an empirical model, A{sub λ,δ}=E(B−V)k{sub λ}(λ/λ{sub V}){sup δ} where k {sub λ} is the dust law of Calzetti et al., and show that there exists a correlation between the color excess E(B−V) and tilt δ with δ=(0.62±0.05)log(E(B−V))+(0.26±0.02). Galaxies with high color excess have a shallower, starburst-like law, and those with low color excess have a steeper, SMC-like law. Surprisingly, the galaxies in our sample show no correlation between the shape of the dust law and stellar mass, star formation rate, or β. The change in the dust law with color excess is consistent with a model where attenuation is caused by scattering, a mixed star–dust geometry, and/or trends with stellar population age, metallicity, and dust grain size. This rest-frame UV-to-near-IR method shows potential to constrain the dust law at even higher redshifts (z>3).

79 ASTRONOMY AND ASTROPHYSICS↗

Estimating total attenuation using Rayleigh targets at cloud top: applications in multilayer and mixed-phase clouds observed by ground-based multifrequency radars

At millimeter wavelengths, attenuation by hydrometeors, such as liquid droplets or large snowflakes, is generally not negligible. When using multifrequency ground-based radar measurements, it is common practice to use the Rayleigh targets at cloud top as a reference in order to derive attenuation-corrected reflectivities and meaningful dual-frequency ratios (DFRs). By capitalizing on this idea, this study describes a new quality-controlled approach that aims at identifying regions of cloud where particle growth is negligible. The core of the method is the identification of a “Rayleigh plateau”, i.e., a large enough region near cloud top where the vertical gradient of DFR remains small. By analyzing co-located Ka–W band radar and microwave radiometer (MWR) observations taken at two European sites under various meteorological conditions, it is shown how the resulting estimates of differential path-integrated attenuation (ΔPIA) can be used to characterize hydrometeor properties. When the ΔPIA is predominantly produced by cloud liquid droplets, this technique alone can provide accurate estimates of the liquid water path. When combined with MWR observations, this methodology paves the way towards profiling the cloud liquid water, quality-flagging the MWR retrieval for rain and drizzle contamination, and/or estimating the snow differential attenuation.

54 ENVIRONMENTAL SCIENCES↗

Effect of duct shape, Mach number, and lining construction on measured suppressor attenuation and comparison with theory

Noise attenuation was measured for several types of cylindrical suppressors that use a duct lining composed of honeycomb cells covered with a perforated plate. The experimental technique used gave attenuation data that were repeatable and free of noise floors and other sources of error. The suppressor length, the effective acoustic diameter, suppressor shape and flow velocity were varied. The agreement among the attenuation data and two widely used analytical models was generally satisfactory. Changes were also made in the construction of the acoustic lining to measure their effect on attenuation. One of these produced a very broadband muffler.

Olsen, W. A.↗

A rack-mounted precision waveguide-below-cutoff attenuator with an absolute electronic readout

A coaxial precision waveguide-below-cutoff attenuator is described which uses an absolute (unambiguous) electronic digital readout of displacement in inches in addition to the usual gear driven mechanical counter-dial readout in decibels. The attenuator is rack-mountable and has the input and output RF connectors in a fixed position. The attenuation rate for 55, 50, and 30 MHz operation is given along with a discussion of sources of errors. In addition, information is included to aid the user in making adjustments on the attenuator should it be damaged or disassembled for any reason.

Cook, C. C.↗