IMPACT RESEARCH
Faa impact research - aviation medicine, human tolerance, acceleration stress, aircraft accidents
SEARCH · Search NASA
Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.
Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.
Faa impact research - aviation medicine, human tolerance, acceleration stress, aircraft accidents
Acceleration stress effects on animal respiratory and cardiovascular systems
Acute and chronic dehydration effects on human tolerance to acceleration stress
Thermo-mechanical analysis (TMA) is typically employed for measurements of the glass transition temperature (Tg) and coefficients of thermal expansion (CTE) in molding compounds used in plastic encapsulated microcircuits (PEMs). Application of TMA measurements directly to PEMs allows anomalies to be revealed in deformation of packages with temperature, and thus indicates possible reliability concerns related to thermo-mechanical integrity and stability of the devices. In this work, temperature dependencies of package deformation were measured in several types of PEMs that failed environmental stress testing including temperature cycling, highly accelerated stress testing (HAST) in humid environments, and bum-in (BI) testing. Comparison of thermo-mechanical characteristics of packages and molding compounds in the failed parts allowed for explanation of the observed failures. The results indicate that TMA of plastic packages might be used for quality evaluation of PEMs intended for high-reliability applications.
Acceleration stress in monkeys, and breathing rate, electrocardiographic, and skin temperature measurements during centrifugation
Premature failures in electrochemical conversion systems often result when membrane electrode assemblies (MEAs) use ultrathin (≤15 μm-thick) polymer electrolyte membranes, susceptible to mechanical degradation from stress concentrations arising from device-level integration. Herein, relief zones were developed to mitigate mechanical degradation by alleviating excess and nonuniform compression across active areas. Relief zones, created through ablation of carbonaceous diffusion media, enable seamless adaptation across MEA dimensions without need for hardware modifications. Demonstrated using fuel cells as a case study, accelerated stress tests revealed a 6-fold lifetime improvement (∼1500 h) compared to conventional edge-protected MEAs, decoupling device-level engineering effects from material limitations.
As microelectronics is scaled into the deep sub-micron regime, space and aerospace users of advanced technology CMOS are reassessing how scaling effects impact long-term product reliability. The effects of electromigration (EM), time-dependent-dielectric-breakdown (TDDB) and hot carrier degradation (HCI and NBTI) wearout mechanisms on scaled technologies and product reliability are investigated, accelerated stress testing across several technology nodes is performed, and FA is conducted to confirm the failure mechanism(s).
Premature cell failures in electrochemical conversion systems often result when membrane electrode assemblies (MEAs) are prepared with ultra-thin (= 15 micrometer-thick) polymer electrolyte membranes (PEMs). These high-performance PEMs are susceptible to mechanical degradation from stress concentrations arising from component and device-level integration. Herein, a relief zone was developed to mitigate mechanical degradation by alleviating excess and non-uniform compression across the active area. Relief zones, created through the ablation of carbonaceous diffusion material achieves a seamless adaptation across a range of MEA dimensions and electrochemical applications without need for costly hardware modifications. This concept was demonstrated using fuel cells as a case study. Accelerated stress test (AST) validations yielded a 6-fold improvement for MEAs prepared with relief zones (i.e., lifetime approximately 1500 h) compared to those fabricated using conventional edge-protection techniques, showcasing the utility of this technique in decoupling integration and device-level engineering effects from intrinsic material limitations for durable electrochemical devices.
We report electrically conductive tape (ECT) was characterized and used to assemble shingled cell strings at low temperature to achieve high reliability Pb- and Ag-free interconnections. The volume resistivity for two considered ECTs are 0.13 ± 0.06 mΩ·cm and 0.47 ± 0.20 mΩ·cm and specific contact resistances, 6.85± 2.00 mΩ·cm 2 and 6.30 ± 0.37 mΩ·cm 2 using the emerging IEC 62788-8-1 Technical Specification for assessment of electrically conductive adhesives (ECA). Durability and performance of the technology in glass–glass mini modules were evaluated with temperature cycling, damp heat testing, and combined-accelerated stress testing (CAST). Through temperature cycling (-40°C to 85°C) applying five times the mini module short-circuit current in forward bias and in the multi climate CAST protocol, there was negligible degradation of fill factor after replacing connectors at the modules' cable leads; however, CAST resulted in short circuit current loss attributed to degradation in light collection by the cells, not the ECT. The IEC 61215-2 85°C, 85% relative humidity damp heat testing showed susceptibility of the HJT cells to effects of humidity in the electroluminescence intensity around the module perimeter that degraded power performance by 4% (relative). Contrasting the IEC 61215-2 qualification testing-based damp heat testing with CAST, factors such as the optical stress of CAST may precipitate the degradation of the modules whereas the humidity levels and duration of IEC 61215-2 damp heat testing may lead to excessive levels of humidity diffused into the modules, potentially resulting in degradation that is unrepresentative of the field.
Abstract Commercial backsheets based on polyvinylidene fluoride (PVDF) can experience premature field failures in the form of outer layer cracking. This work seeks to provide a better understanding of the changes in material properties that lead to crack formation and find appropriate accelerated tests to replicate them. The PVDF-based backsheet outer layer can have a different structure and composition, and is often blended with a poly(methyl methacrylate) (PMMA) polymer. We observed depletion of PMMA upon aging with sequential (MAST) and combined (C-AST) accelerated stress testing. In field-aged samples from Arizona and India, where PVDF crystallizes in its predominant α-phase, the degree of crystallinity greatly increased. MAST and C-AST protocols were, to some extent, able to replicate the increase in crystallinity seen in PVDF after ~ 7 years in the field, but no single-stress test condition (UV, damp heat, thermal cycling) resulted in significant changes in the material properties. The MAST regimen used here was too extreme to produce realistic degradation, but the test was useful in discovering weaknesses of the particular PVDF-based outer layer structure studied. No excessive β-phase formation was observed after aging with any test condition; however, the presence of β-phase was identified locally by Fourier transform infrared spectroscopy (FTIR). We conclude that both MAST and C-AST are relevant tests for screening outdoor failure mechanisms in PVDF backsheets, as they were successful in producing material degradation that led to cracking.
Electrode cracks in polymer electrolyte membrane fuel cells (PEMFCs) are correlated with early onset failures. Here, in this work we investigate the influence of cracked gas diffusion electrodes (GDEs) on the durability of the membrane electrode assembly (MEA) using a combined chemical-mechanical accelerated stress test (AST). Electrode crack dimensions were systematically tuned using ink formulations and material selection strategies. A parameter to describe the crack width areal density (Φ CW ) was used to quantify the degree of discontinuity in the electrode surfaces. Open circuit voltage (OCV) transient analyses were used to benchmark and characterize the failure mechanisms in the MEAs as a function of the Φ CW . While smaller electrode-level cracks, on the order of microns, yielded a 28 % decrease in operating lifetime, larger cracks that propagated from a discontinuous, microporous layer (MPL) coating, decreased the operating lifetime by 56 %. This work emphasizes the need for material processing strategies that consider defect tolerances to limit membrane failures in PEMFCs.
Carbon-supported platinum nanoparticles (Pt/C) are currently the state-of-the-art catalyst in proton exchange membrane fuel cells (PEMFCs). Unfortunately, the carbon support lacks the ability to stabilize the metal catalyst, as platinum tends to dissolve and agglomerate, significantly compromising the durability. Herein, we synthesized a ceramic material, molybdenum carbide aerogel (MCAG), and utilized it as a Pt support for PEMFCs, as an alternative for conventional carbon supports. N 2 adsorption and XRD analysis showed that the MCAG possesses a combination of high porosity and a well-defined ceramic crystalline structure. The Pt/MCAG system was studied for its electrocatalytic activity toward ORR in a half-cell and demonstrated satisfactory reaction kinetics and electrochemical active surface area, comparable to the commercial Pt/C. For durability examination, an accelerated stress test (AST) in a single cell was conducted with the Pt/MCAG catalyst at the cathode, following the U.S. DOE electrocatalyst AST protocol. Intermediate polarization curves and cyclic voltammograms were recorded over the course of the AST to monitor the aging process. The results indicated that the MCAG support exhibited superior durability in long-term fuel cell operation compared to a carbon support. The Pt/MCAG system demonstrated stable behavior during the progressive stages of the AST, retaining more than 50% of its initial performance by the end of the test, whereas carbon-supported Pt preserved only 30%.
The proton exchange membrane integrity can be compromised during hot-press fabrication of membrane electrode assemblies (MEAs) causing premature cell failures during operation. In this work, infrared (IR) thermography was used as a diagnostic tool to spatially visualize hydrogen (H 2 ) crossover and identify process-induced-membrane irregularities (PIMs). These irregularities were identified as seed locations for MEA failures. Fine tuning of hot-press conditions was used to mitigate premature cell failures informed by accelerated stress testing (AST). The impact of PIMs on the initial performance, high-frequency resistances, open-circuit voltage, and H 2 crossover are reported. Nafion XL and 212 membranes, hot-pressed with a force of 16 kg/cm 2 and temperature of 120°C, were found to be consistently irregularity-free. Irregularity-free MEAs using Nafion 211, 212, and XL membranes demonstrated AST lifetime improvements of 58, 64 and 400%, respectively, compared to those fabricated with non-optimized conditions. In conclusion, this work highlights the importance of fabrication parameters on premature cell failures.
The development of aerospace systems capable of very high levels of positive vertical accelerators stress has created a need for a better understanding of the cardiovascular responses to acceleration. Using a canine model, the heart and cardiovascular system were instrumented to continuously measure coronary blood flow, cardiac output, left ventricular and aortic root pressure, and oxygen saturation in the aorta, coronary sinus, and right ventricle. The animals were exposed to acceleration profiles up to +6 G, 120 s at peak G; a seatback angle of 45 deg was simulated in some experiments. Radiopaque contrast medium was injected to visualize the left ventricular chamber, coronary vasculature, aorta, and branches of the aorta. The results suggest mechanisms responsible for arrhythmias which may occur, and subendocardial hemorrhage which has been reported in other animals.
The influence of different combinations of accelerated stress test (AST) protocols simulating load-cycle and start/stop conditions of a proton exchange membrane fuel cell (PEMFC) vehicle is investigated on a bimodal Pt/C catalyst. The bimodal Pt/C catalyst, prepared by mixing two commercial catalysts, serves as a model system and consists of two distinguishable size populations. The change in mean particle size was investigated by in situ small-angle X-ray scattering (SAXS). The comparison to the reference catalysts, i.e., the two single-size population catalysts, uncovers the presence of electrochemical Ostwald ripening as a degradation mechanism in the bimodal catalyst. Increasing the harshness of the applied AST protocol combinations by faster changing between load-cycle or start/stop conditions, the particle size of the larger population of the bimodal catalyst increases faster than expected. Surprisingly, the change in mean particle size of the smaller size population indicates a smaller increase for harsher AST protocols, which might be explained by a substantial electrochemical Ostwald ripening.
The purpose of this protocol is to use accelerated stress testing to assess the durability of metal halide perovskite (MHP) photovoltaic (PV) modules. The protocol aims to apply field relevant stressors to packaged MHP modules to screen for early failures that may be observed in the field. The current protocol has been designed with a glass/glass-PIB edge seal, no encapsulant package in mind. PACT anticipates adding additional testing sequences to evaluate additional stressors (e.g., PID, reverse bias) in the future.
Accelerated stress corrosion tests for aluminum alloys
The 'Framing' (local discoloration along cell edges) was induced by a simple sequential accelerated stress test (consisting of hygrothermal- and UV-stressors) applied to the PV modules with high OTR (oxygen transmission rate) backsheet, irrespective of the inclusion of UV-absorber in poly(ethylene-co-vinyl acetate) (EVA) encapsulant. UV-fluorescence imaging of the PV modules suggests that the spatially-inhomogeneous degradation of EVA material under UV-irradiating conditions is correlated to this 'Framing' indicating an underlying common mechanism. These findings would contribute to the development of test procedures to broadly mimic the actual failures observed in fielded PV.