Operation of NASA's Airborne Visible/Infrared Imaging Spectrometer (AVIRIS) on a NOAA Twin Otter Aircraft Measuring 4 Meter Spatial Resolution AVIRIS Images
Explore the source record for details and available documents.
SEARCH · Search NASA
Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.
Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.
Explore the source record for details and available documents.
An evaluation of atmospheric correction of AVIRIS data using radiative transfer codes LOWTRAN7 and MODTRAN is presented. The algorithm employed is based on a simple model of radiance L at each wavelength at the sensor that can be written approximately LAV=Lp+Tp, where subscript AV referes to AVIRIS, Lp is the path radiance and Tp is the diffuse + direct transmitted radiance of the atmosphere at AVIRIS.
This paper focuses on determination of the temporal and spatial gas absorption and aerosol scattering properties of the atmosphere itself including the radiative properties of clouds, specifically derivation of estimates of aerosol optical depth, atmospheric water vapor, and oxygen pressure surface altitude form upwelling near-TOA spectral radiance measurements obtained with the AVIRIS.
Imaging spectrometry data must be spectrally, radiometrically and geometrically calibrated. This calibration process is validated for in-flight performance of the sensor using a rigorous ground truth campaign.
The AVIRIS instrument uses an onboard calibration system to provide auxiliary calibration data. The system consists of tungsten halogen cycle lamp imaged onto a fiber bundle through an eight position filter wheel. The fiber bundle illuminates the back side of the foreoptics shutter during a pre-run and post-run calibration sequence. The filter wheel contains 2 neutral density filters, 5 spectral filters and blocked position.
This paper describes recent improvements in the AVIRIS data facility.
To validate AVIRIS in flight, and in-flight calibration experiment was performed for an over-flight on May 9, 1995, at Ivanpah Playa, California, USA. In-situ measurements were used to constrain a radiative transfer code and predict the total upwelling spectral radiance incident at AVIRIS.
The principal problem with application of airborne imaging spectrometers to lakes is the weak upwelling signal, especially when narrow spectral bands with high spatial resolution are sought. Furthermore, atmospheric path radiance dominates the signal received from dark targets such as lakes. Once atmospheric effects have been removed from the radiance received at the sensor, semi-empirical relationships can be developed to extract information about phytoplankton pigment concentrations for different underwater optical conditions. In lakes where concentrations of dissolved organics and suspended detritus may not co-vary with phytoplankton pigments, the many spectral channels of an imaging spectrometer such as AVIRIS are likely to be required to distinguish the various aquasols. The objectives of our study are to: (1) estimate the chlorophyll content of a lake with hundred-fold seasonal ranges in chlorophyll concentration using atmospherically corrected upwelling radiances derived from AVIRIS imagery, and (2) to examine spatial patterns in chlorophyll after reduction of the coherent noise in the imagery by filtering techniques.
New spaceborne and airborne imaging spectrometers are being proposed and developed to derive properties of the Earth's surface from measurements of the upwelling radiance in the solar reflected spectrum.
The Airborne Visible/Infrared Imaging Spectrometer (AVIRIS), flown aboard the NASA ER-2 aircraft in 1987 and 1989, used four linear arrays and four individual spectrometers to collect data simultaneously from the 224 bands in a scanned 614 pixel-wide swath perpendicular to the aircraft direction. The research had two goals. One was to evaluate the AVIRIS data. The other was to look at the subtle lithological variation at the two test sites to develop a better understanding of the regional geology and surficial processes. The geometric characteristics of the data, adequacy of the spatial resolution, and adequacy of the spectral sampling interval are evaluated. Geologic differences at the test sites were mapped. They included lithological variation caused by primary sedimentary layering, facies variation, and weathering; and subtle mineralogical differences caused by hydrothermal alterations of igneous and sedimentary rocks. The investigation used laboratory, field, and aircraft spectral measurements; known properties of geological materials; digital image processing and spectrum processing techniques; and field geologic data to evaluate the selected characteristics of the AVIRIS data.
The status of the Airborne Visible and Infrared Imaging Spectrometer (AVIRIS) is reported at the beginning of the current flight season. Sensor performance based on laboratory measurements and trend data as well as a review of end of 1995 season performance is given as a measure of expected performance during the 1996 season which began in March of 1996. Recent improvements to the sensor's internal calibration source and measurements of instrument parameters are described. The effects of these enhancements on the reported data are also discussed along with and update onflight schedules and plans for 1996 flight operations.
The relationship between the surficial iron mineralogy and economic mineralization is investigated, using data from an airborne imaging spectrometer (the 63-channel Geophysical and Environmental Research Imaging Spectrometer) to map the distribution of iron minerals in the Cripple Creek mining district in Colorado. The airborne image data were coregistered with the field map data for the distribution of iron oxides in the district, in a geographic information computer system, in order to compare their information content. It is shown that the remote imagery was able to uniquely identify the mineral hematite, a mixture of goethite/jarosite, and a mixture of hematite/goethite.
Techniques using Munsell color transformations were developed for reducing 128 channels (or less) of Airborne Imaging Spectrometer (AIS) data to a single color-composite-image suitable for both visual interpretation and digital analysis. Using AIS data acquired in 1984 and 1985, limestone and dolomite roof pendants and sericite-illite and other clay minerals related to alteration were mapped in a quartz monzonite stock in the northern Grapevine Mountains of California and Nevada. Field studies and laboratory spectral measurements verify the mineralogical distributions mapped from the AIS data.
Report reviews history and state of art of terrestrial imaging spectroscopy. Discusses history, design, and performance of Airborne Imaging Spectrometer (AIS), which is pioneering sensor for terrestrial high-resolution remote sensing. Also discusses recent developments described in literature of imaging spectroscopy from three points of view: techniques for handling and analysis of spectral-image data, geological research, and botanical research. This field encompasses use of airborne and spaceborne imaging spectrometers to generate specialized maps for use in agriculture, geology, ecology, and related disciplines.
FIREFLY (Fluorescence Imaging of REd and Far-red Light Yield) is a compact, fine-resolution imaging spectrometer that was designed and assembled by Headwall Photonics (Fitchburg, MA, USA) in collaboration with NASA scientists for airborne measurements of Solar-Induced Fluorescence (SIF). FIREFLY is integrated into the next generation of NASA Goddard’s Lidar, Hyperspectral and Thermal airborne imager (G-LiHT; www.gliht.nasa.gov), providing a complete system for measuring, interpreting and scaling SIF emissions. Characterization of FIREFLY was performed here to evaluate its performance and suitability for retrieving SIF.
The NASA Imaging Spectrometer program has the objective to develop the next generation of earth remote sensing systems. One part of the program is concerned with the production of advanced short-wavelength mercury cadmium telluride (HgCdTe) hybrid focal plane arrays (FPAs). These arrays are needed for several instruments, including the Shuttle Imaging Spectrometer (SIS), which requires a mosaic of six 64 x 64-element arrays with a cutoff wavelength of 2.5 microns. A device description is provided and the test results are considered. The Airborne Imaging Spectrometer (AIS) is discussed, taking into account an instrument description, focal plane requirements, and AIS results.